Loading...
BLD20070567 QFC #851 Remodel 22828 100 Av.doc MEMORANDUM Date:June 18, 2007 Development Services Lead Theresa Umbaugh To: From:Fire Marshal John J. Westfall 425.771.0213 th Subject:BLD20070567 QFC #851 Remodel 22828 100 Ave W The following project has been evaluated under the Edmonds Community Development Code, 2003 International Fire Code. Please resubmit with following corrections/clarifications: Building is provided with NFPA 13 automatic fire sprinkler system and fire alarm. 1. Is your intent to remain open during remodel? (Yes:) Assure required exits are maintained clear at all times and fire protection systems, appliances and fire sprinkler systems are un-impaired and accessible. 2. Provide fixture/furnishings plan referenced on your submittal. 3. Sht A0.0 CODE SUMMARY: “FIRE SPRINKLER: FULLY NFPA 13. 4. Sht A0.0 GENERAL INFORMATION, DESIGN-BUILD SUBMITTALS: Add (7) FIRE SUPPRESSION PERMIT(s). 5. Sht A0.0 GENERAL NOTES: Delete Note G. 6. Sht A0.2 KEYNOTES 1 & 6: remove exit signs at existing BEVERAGE (120) and existing FLORAL (133) exits. 7. Sht A2.0/A2.1 Call out Class 2A:10B:C (min.) rated portable fire extinguisher locations. 8. Sht A2.0/A2.1 Call out Class K(s) rated portable fire extinguisher location(s) within 30’ of commercial cooking system(s). 9. Sht A2.0/A2.1 Call out emergency lighting and exit signs. 10. Sht A2.0 KEYNOTES (5). “…Separate mechanical (hood) permit and fire (suppression) permit are required for commercial cooking applications.” City of Edmonds Fire Marshal   11. Sht A2.0 Keep fire sprinkler riser area clear of equipment and storage near matchline F1. 12. Detail handrail and stair to public way at new exit 107X. Cc: Mr. Jim Babine, MulvanneyG2 Architecture, fax 425-463-2029 Ms. Marie Hoffman, Kroger Facility Engineering, fax 206-622-3832 Building Official Jeannine Graf