BLD20070640-5 Valhalla Townhomes Edm Wy RESUB.doc MEMORANDUM Date:November 29, 2007 To:Development Services Lead Marie Harrison From:John Westfall, Fire Marshal (425) 771-0213 Subject:BLD20070640, BLD20070641, BLD20070642, BLD20070643, BLD20070644, BLD20070645 RESUB nd 232 Street Townhomes 23004-23014 Edmonds Wy The Fire Department provides the following comments and corrections in accordance with the 2003 International Fire Code and Edmonds Community Development Code: All permits Sheet A0 1. SEPARATE PERMITS a. Delete reference to FIRE SPRINKLER. Sprinkler is not required except for 5 or more townhomes. Exceptions: i Voluntary NFPA 13R sprinkler allowed with penetrations meeting IRC R317 ii Voluntary NFPA 13D sprinkler allowed for each dwelling with no penetrations. Iii Voluntary sprinkler system requires Fire Connection permit. 2. SITE PLAN a. Draw clear approved turnaround where DRIVE AISLE takes turn so that BLDG A does not exceed 150’ vehicular access for firefighting purposes. b. Show fire lane from north DRIVE AISLE entry to south DRIVE AISLE egress. Fire lane shall be striped with 4” yellow perimeter striping and identified with words “FIRE LANE – NO PARKING”. Letters shall be 12” high with 2” stroke spaced 50 lineal feet on alternating insides of lane. 3. BUILDING CODE a. Clarify IRC construction and delete IBC references. b. Correct OCCUPANCY GROUPS are R3/U. c. Building is not required to be “FULLY SPRINKLERED”. Remove from table and recalculate. i. Voluntary sprinkler systems: Automatic sprinkler system increase may be taken for approved NFPA 13 (903.3.1.1) or NFPA 13R (903.3.1.2) systems. NFPA 13D (903.1.1.3) systems for dwellings do not meet minimum requirements for height or area increases IBC 504.2 4. ZONING CODE City of Edmonds Office of Fire Marshal   a. Correct OCCUPANCIES are R3 / U. All permits Sheet A0.1 5. CONTRACTOR COORDINATION NOTES a. Delete 2.C and 2.D or re-evaluate for voluntary sprinkler system(s). b. Add NOTE: “FIRE PREVENTION PROGRAM SUPERINTENDENT POC IS (add name and telephone # here) AND 24 HOUR TELEPHONE CONTACT FOR EMERGENCY PURPOSES. FP PROGRAM SUPERINTENDENT SHALL HAVE AUTHORITY TO ENFORCE FIRE SAFETY PROVISIONS.” 6. DIAGRAMMATIC a. Correct “R3” vs. “R2” BLD20070640 Building A 23004 7. Sheet A2.1 & A3.1 Garage plan a. Sheet A2.1 Install min. rated 2A:10B:C portable fire extinguisher (FE) between garage entries for units A-2 and A-3. b. Sheet A3.1 Show FE in south elevation 8. Sheet A3.1 Add building address signage on north elevation. 9. Sheets A2.2 & A2.3 Add hardwired, interconnected smoke alarms with battery backup at each dwelling level, inside and outside sleeping rooms. OK BLD20070641 Building B 23006 10. Sheet A2.1-B & A3.1-B Garage plan a. Sheet A2.1 Install min. rated 2A:10B:C portable fire extinguisher (FE) between garage entries for units B-1 and B-2. b. Sheet A3.1 Show FE in south elevation 11. Sheet A3.1 Add building address signage on north elevation. 12. Sheets A2.1-B & A2.2-B Add hardwired, interconnected smoke alarms with battery backup at each dwelling level, inside and outside sleeping rooms. BLD20070641 Building C 23008 13. Sheet A2.1 & A3.1 Garage plan a. Sheet A2.1 Install min. rated 2A:10B:C portable fire extinguisher (FE) between garage entries for units C-2 and C-3. b. Sheet A3.1 Show FE in south elevation 14. Sheet A3.1 Add building address signage on north elevation. 15. Sheets A2.2 & A2.3-C Add hardwired, interconnected smoke alarms with battery backup at each dwelling level, inside and outside sleeping rooms. 2 BLD20070641 Building D 23010 16. Sheet A2.1 & A3.1 Garage plan a. Sheet A2.1 Install min. rated 2A:10B:C portable fire extinguisher (FE) between garage entries for units D-2 and D-3. b. Sheet A3.1 Show FE in south elevation 17. Sheet A3.1 Add building address signage on north elevation. 18. Sheets A2.2 & A2.3 Add hardwired, interconnected smoke alarms with battery backup at each dwelling level, inside and outside sleeping rooms. BLD20070641 Building E 23012 19. Sheet A2.1 & A3.1 Garage plan a. Sheet A2.1 Install min. rated 2A:10B:C portable fire extinguisher (FE) between garage entries for units E-2 and E-3. b. Sheet A3.1 Show FE in north elevation 20. Sheet A3.1 Add building address signage on north elevation. 21. Sheets A2.2 & A2.3 Add hardwired, interconnected smoke alarms with battery backup at each dwelling level, inside and outside sleeping rooms. BLD20070641 Building F 23014 22. Sheet A3.1 Correct cardinal directions to elevations. 23. Sheet A2.1 & A3.1 Garage plan a. Sheet A2.1 Install min. rated 2A:10B:C portable fire extinguisher (FE) between garage entries for units F-1 and F-2. b. Sheet A3.1 Show FE in north elevation 24. Sheet A3.1 Add building address signage on north elevation. 25. Sheets A2.2 & A2.3 Add hardwired, interconnected smoke alarms with battery backup at each dwelling level, inside and outside sleeping rooms. Cc: Mr. Tony Shapiro, A.D. Shapiro Architects tonys@adshapiro.com Mr. James Abbott, SGA Corporation, jabbott@sgacorp.com Engineering Program Technician Jeanie McConnell Assistant Building Official Ann Bullis 3