BLD20070978-2 SFR.pdf City of Edmonds TH 121 5 AVENUE NORTH • EDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221 Website: www.ci.edmonds.wa.us DEVELOPMENT SERVICES DEPARTMENT Planning • Building • Engineering Plan Review Corrections Plan Check : Date: # BLD 2007-0978 January 17, 2008 Project Name/Address: Harvey / SFR and DEMO 1240 Birch St. Contact Person/Address/Fax: Tom Leren/Phone: 425-776-6007/Fax: 425-771-8401/e-mail: tom@lerendesign.com Reviewer: Jaime HawkinsDivision:Engineering During review of the subject submittal, it was found that the following information, corrections, or clarifications would need to be addressed: 11/14/2007 1.- Please show all the existing/proposed utilities in the site plan and in sheet C1 of 1. Water 1/17/2008 meter, water service line (from the meter to the house), side sewer, power, gas, etc. – You failed to include the required information in the Site plan as previously requested. Please revise the Site plan as requested per these corrections. 11/14/2007 2.- Is the existing water meter to remain at its present location or is it to be relocated. Please show existing and proposed location if applicable. This property is serviced by the OVWSD, water only. 1/17/2008 – Not shown in the Site plan. 11/14/2007 3.- With the installation of the new side sewer, a 6-in clean with 12-in cast iron locking lid shall be installed at the property line per E6.2. Please add this call out on both the site plan and sheet C1 1/17/2008 of 1. – Not shown in the Site plan. 11/14/2007 4.- Show the sewer extension and clean out for the drainage of the proposed swimming pool in 1/17/2008 both the site plan and sheet C1 of 1. – Not shown in the Site plan. 11/14/2007 5.- Show the proposed external shower connecting to the side sewer. Both the site plan and 1/17/2008 sheet C1 of 1.– Not shown in the Site plan. 11/14/2007 6.- Construction Sequence #9. Please revise section in parenthesis “…. (Contact the Olympic View Water and Sewer District for sewer inspections….)” The City of Edmonds is responsible for both 1/17/2008 the water and sewer inspections. – Not shown in the Site plan. 11/14/2007 7.- Provide a breakdown of the proposed Impervious Surface in both the site plan and sheet C1 1/17/2008 of 1. – Not shown in the Site plan. 11/14/2007 8.- Show all piping between pool equipment shed and pool on the site plan and sheet C1 of 1. 1/17/2008 – Not shown in the Site plan. DATE FAXED/E-MAILED 1/17/2008 Please submit resubmission to your permit coordinator. You may resubmit by fax: 425-771-0221. Please contact me at 425-771-0220 if you have specific questions regarding these plan corrections. DATE FAXED/E-MAILED 1/17/2008