BLD20071106-17 Townhomes 23828 Edmonds Wy.doc MEMORANDUM Date:December 21, 2007 To:Development Services Lead Marie Harrison From:John Westfall, Fire Marshal 425-771-0213 Subject:BLD20071104 and BLD20071106 to BLD20071117 23800-23824 Edmonds Arbor Court Townhouses The Fire Department provides the following comments and corrections in accordance with the 2006 International Fire Code and Edmonds Community Development Code: CIVILS/SITE 1. Sheet A1.0 & C4.1 Fire hydrant spacing exceeds city requirements for RM zoning. Hydrants along east side of Edmonds Way are considered inaccessible due to large trip counts on SR- 104. ECDC 19.25.055D. Install new public hydrant at property entrance on west side of SR 104. 2. Sheet A1.0 & C4.1 Show location & detail for one new public and one new private hydrant (west of bldg #10). Use DWG NO. E7.1 from http://www.ci.edmonds.wa.us/engr_toc_std_details.stm 3. Show detail for emergency address sign at property entrance. Use DWG NO. E8.3 from http://www.ci.edmonds.wa.us/engr_toc_std_details.stm . 4. Sheet A1.0 & C4.1 Fire lane shall be striped with 4” yellow perimeter striping and identified with words “FIRE LANE – NO PARKING”. Letters shall be 12” high with 2” stroke spaced 50 lineal feet on alternating insides of lane. 5. Provide NO PARKING FIRE LANE signs 18” high x 12” wide with red lettering on a white reflective background and mounted with bottom of sign 48” to 60” above grade facing fire lane at following locations: a. SE exterior of BLDG #1 b. Between BLDGs #2 and #10 c. South side of BLDG #7 d. NE exterior of BLDG #3 e. Between BLDGs #5 and #6 ARCHITECTURAL City of Edmonds Office of Fire Marshal   6. Property covenants that are provisions for the continued maintenance of fire lanes and parking enforcement shall be recorded prior to final inspection for the first unit in the development. Approved wording is currently in draft. 7. Sheet CS-1.0 Please add building addresses to INDIVIDUAL BUILDING DATA. 8. Sheet CS-1.0 DESIGN CRITERIA: Delete R2 occupancy references, replace with R3 townhouse occupancy, and recalculate. 9. Sheet CS-1.0 FIRE PREVENTION NOTES and Sheet A3.0 ELEVATIONS, add note: “EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE OPERABLE EMERGENCY ESCAPE AND RESCUE OPENING PROVIDED AND MAINTAINED THAT SHALL OPEN DIRECTLY INTO A PUBLIC WAY, OR TO A YARD OR COURT THAT OPENS TO A PUBLIC WAY.” 10. Sheets A6.0 through A6.7: Edit NOTE: “ALL SMOKE DETECTORS TO BE HARD-WIRED, INTERCONNECTED, AND WITH TIED INTO WIRING AND HAVE A BATTERY BACKUP-PER IRC SEC R313.” 11. Sheet A3.0 Add note: “BUILDINGS SHALL HAVE APPROVED ADDRESS NUMBERS PLACED IN A POSITION LEGIBLE AND VISIBLE FROM (FIRE APPARATUS) ACCESS ROAD FRONTING THE STRUCTURE. ADDRESS NUMBERS SHALL BE ARABIC NUMERALS, A MINIMUM OF 4 INCHES HIGH WITH MINIMUM STROKE WIDTH OF ½ INCH, AND IN CONTRAST TO THEIR INSTALLED BACKGROUND. “ 12. Property covenants that are provisions for the continued maintenance of fire lanes and parking enforcement shall be recorded prior to final inspection for the first unit in the development. Approved wording is currently in draft. Cc: Jay Finney, Real Property Development Co LLC, jfinney@rpaseattle.com Jean Morgan, Morgan Design Group, jean@morgan-design.net Michael Spano, CG Engineering, mikes@cgengineering.com Roger Eberhart, OVWD rogere@ovwater.com COE Engineering Technician Jeanie McConnell COE Residential Plans Reviewer Jenny Readwin 2