Loading...
BLD20071162-3 Sound & Oly View Apts 2.doc MEMORANDUM Date:December 27, 2007 To:Development Services Lead Marie Harrison From:John Westfall, Fire Marshal, 425-771-0213 Subject:REPLY for CORRECTIONS rd BLD20071162 Sound View Apts 417 3 Av S BLD20071163 Olympic View Apts 303 Howell Wy The Fire Department provides the following comments and corrections in response to your email PROJECT MEMO dtd 12/21/07: Notes have been added to your plans as follows: IF YOU RESUBMIT WITH OTHER CORRECTIONS, INCORPORATE THE FOLLOWING CORRECTIONS INTO YOUR REVISED SHEETS : 1. Sheet A1.0 General Note added: SMOKE ALARMS IN APARTMENTS OLDER THAN TEN YEARS SHALL BE REPLACED (NFPA 72 11.8.1.4). SMOKE ALARMS SHALL BE HARD-WIRED, INTERCONNECTED, WITH BATTERY BACKUP. 2. Sheet A1.0 Listed permits: REQUIRED PERMITS/SUBMITTALS INCLUDE: a. FIRE CONNECTION PERMIT FIRE CONNECTION PERMIT IS REQUIRED FOR THE INSTALLATION OF THE UNDERGROUND SUPPLY FOR YOUR FIRE PROTECTION SYSTEM. UNDERGROUND DESIGN MUST BE STAMPED BY REGISTERED PE OR A LEVEL III (WA) FIRE SPRINKLER CONTRACTOR AND THE INSTALLER MUST ALSO STAMP THE PLANS. THE INSTALLER MUST BE EITHER LEVEL III OR LEVEL “U” FIRE SPRINKLER CONTRACTOR LICENSED BY THE STATE. PROVIDE THREE COPIES OF PLANS SHOWING ALL VALVES, VAULT LOCATION, POST INDICATING VALVE, FIRE DEPARTMENT CONNECTION AND PIPING TO INCLUDE SIZE AND MATERIAL, HYDRAULIC CALCULATIONS, THRUST BLOCKING WITH CALCULATIONS, PIPE BURY DEPTH AND ANY AND ALL OTHER MATERIALS USED AND THEIR FIRE PROTECTION LISTINGS. RCW 18.160.070 / RCW 18.27.110 b. FIRE SPRINKLER SYSTEM PERMIT c. FIRE ALARM PERMIT City of Edmonds Office of Fire Marshal   3. Sheet A1.0 (Automatic closing assembly smoke and heat control is not opted by owner). Added note: INSTALL “FIRE DOOR KEEP CLOSED” SIGNAGE AT FOLLOWING LOCATIONS: i. Sheets A2.5 (OV) & A2.15 (SV) COMMUNITY ROOM - CORRIDOR ii. Sheets A2.5 (OV) & A2.15 (SV) LOBBY - OFFICE iii. Sheets A2.6 (OV) & A2.17(SV) LAUNDRY iv. Sheet A2.7 (OV) BEAUTY SALON v. Sheets A2.8 (OV) & A2.18 (SV) LIBRARY vi. Sheets A2.6-A2.8 (OV) & A2.16-A2.18 (SV) CORRIDOR - ELEVATOR LOBBY 4. Sheets A2.5 & A2.15 Note added: EXISTING RISERS THAT WILL BE ABANDONED ARE LOCATED IN STAIRWAY #1. NEW RISERS SHALL BE INSTALLED NEXT TO EXISTING WHILE MAINTAINING EGRESS CLEARANCES. 5. Sheets A2.5-A2.8 (OV) & A2.15-A2.18 (SV) Changed GENERAL NOTE #4: (Emergency lighting…) VERIFY LOCATION WITH FIRE MARSHAL. 6. Sheet A3.1 & A3.2 Changed note #21: EXISTING CIGARETTE RECEPTACLE TO BE REMOVED. PATCH AND REPAIR WALL PER SPECIFICATIONS. 7. Sheet A3.1& A3.2 Added note: UPDATE KEYS FOR FIRE DEPARTMENT LOCKBOX. 8. Sheet A3.1 & A3.2 Added note: POST BUILDING ADDRESS IN A POSITION VISIBLE FROM BUILDING. BUILDING NUMBERS SHALL BE A MINIMUM OF 4 INCHES HIGH WITH A MINIMUM STROKE WIDTH OF ½ INCH. THESE NUMBERS SHALL BE ARABIC NUMERALS AND CONTRAST WITH THEIR INSTALLED BACKGROUND. Cc: Mr. Glenn Hydahl,Housing Authority-Snohomish County glenn@hasco.org Mr. Scott Schreffler Dykemman Architects, scotts@dykeman.net Engineering Program Technician Jeanne McConnell Assistant Building Official Ann Bullis 2