BLD20080790 155 3 Av S.doc MEMORANDUM Date:December 8, 2010 To: Marshall Elliot Shaw shawelevator@comcast.net Ashton Wolfe ashtonw@wolfefireprotection.com From:Fire Marshal John J. Westfall 425.771.0213 rd Subject:BLD2008-0790 Mixed Use Building, 155 3 Av S Thanks for meeting with Fire and Building Depts. City of Edmonds wishes success on this project. We suggest a design professional to assist with development of your ideas. Building Department will provide permitting strategy to assist you and this project finally to completion. Current plans require modification, submittal and approvals before new work is performed for any plan changes. 2006 This review conducted in accordance with IFC and ECDC due to renewed permits. Fire Prevention Services provides the following comments: 1. Fire sprinkler underground is complete to the bottom of the sprinkler riser. BLD20061379 was accepted on 5/3/2008. 2. Existing approved fire sprinkler plans under permit BLD2009-0850. Existing approved fire alarm plans under permit BLD2008-0883. 3. Sprinkler and header clearance in garage. “I” beam header at parking garage entry is 6’ 9” and portions of sprinkler piping are 6’ 8½ “ AFF. Use Building - approved protective mechanical shield to wrap beam and spray on fireproofing. Provide horizontal scrape bar across horizontal entry on street side of shield. Post height at 6’ 8” or Building-approved height. Modify and submit plans corrections for approval. 4. Sprinkler Dayton St entry overhang. Horizontal projection exceeds 4’ in width rd and is part of the floor assembly for 3 floor occupancy. “Areas under exterior ceilings where the building is sprinklered should be protected due to the occupancy above” NFPA 13 A.8.15.7.2 5. In entry foyer and throughout, usable/accessible under-stair spaces require sprinkler coverage and mechanical protection installed below 6’ AFF. “Sprinklers shall be installed beneath all stairways of combustible construction”. NFPA 13 8.15.3.1 6. CPVC application in residential/light-hazard areas for IFC 903.3.1.1 NFPA 13 systems approved for use in change-of-use to a different light hazard City of Edmonds Office of Fire Marshal   occupancy, however, sprinkler coverage must be modified. Modify and submit plans corrections for approval. 7. FDC and PIV location on exterior wall at inset area as indicated on project plans (BLD20080790) is approved. FDC and PIV cannot encroach in ROW. FDC shall be 4” quarter-turn type fitting (storz). Cc: Building Official Leonard Yarberry Asst. Building Official Leif Bjorback 2