Loading...
BLD20100129-Ali_3.pdf City of Edmonds BLD2010 0129 TH 121 5 AVENUE NORTH EDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221 Website: www.ci.edmonds.wa.us PUBLIC WORKS DEPARTMENT Planning • Building • Engineering Engineering Plan Review Comments Permit Application :Date: #BLD2010 0129 4/20/10 Project Name/Address: ALI – 709 DRIFTWOOD PL Contact Person/Address, Fax or E-mail: HANSONDESIGN@HOTMAIL.COM Reviewer: JENNIFER LAMBERT Division: ENGINEERING During review of the subject submittal, it was found that the following information, corrections, or clarifications would need to be addressed. All Handouts referred to in these comments can be accessed at our website: www.ci.edmonds.wa.us under City Government / Development Services Department / Engineering Division then scroll down to Handouts: st 1 Review – 3/16/10 nd 2 Review – 4/8/10 rd 3 Review – 4/20/10 SITE PLAN 1)OK 2)OK 3)OK 4)OK 5)OK 6)OK 7)OK 8)OK 9)4/20/10 – Comment was partially addressed. A tightline and catch basin were added to the plans, but it is unclear if the tightline and CB are existing or proposed. a.If the CB is existing, does it exist in the city sewer easement? b.If the CB is existing, is there a pipe that leaves the site? If so, where does it outfall to? DATE E-MAILED 4/8/10 PAGE() 1 City of Edmonds BLD2010 0129 TH 121 5 AVENUE NORTH EDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221 Website: www.ci.edmonds.wa.us PUBLIC WORKS DEPARTMENT Planning • Building • Engineering Engineering Plan Review Comments c.If the CB is existing, but has an open bottom (meaning it is a drywell), please note that on plans. d.If the CB does NOT exist, but is proposed, please move CB outside of the easement line and show where the water from the CB will be released. 4/8/10 Comment was partially addressed. It appears that the roof drains tie to a drywell (see attached). Please locate and show the drywell. e.Please show the dimensions of the existing sytem. f.Please show that the existing system can handling the additional impervious area. The system may need to be increased. 3/16/10 Comment: Please show or note on plans where the existing downspouts currently release, where the driveway surface water runoff leaves your property, and show any storm system installed on your property (i.e. do they release to splash blocks, do the downspouts go into the ground to an existing system, etc.). Please resubmit 3 copies of the revised site drawings and associated documents with a written response to each item to an Engineering Technician. Please contact me at 425-771-0220 ext 1321 or by e-mail at collinsj@ci.edmonds.wa.us if you have specific questions regarding these plan corrections. DATE E-MAILED 4/8/10 PAGE() 2