bld20100561-Dean_ENG4.pdf City of Edmonds BLD20100561 TH 121 5 AVENUE NORTH EDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221 Website: www.ci.edmonds.wa.us PUBLIC WORK DEPARTMENT Planning • Building • Engineering Engineering Plan Review Comments Permit Application :Date: # BLD20100561 July 13, 2012 th Project Name/Address: Dean – 8511-218 St SW Contact Person/Address, Fax or E-mail: Shannon Ramey – rampart.sdr@hotmail.com Reviewer: JENNIFER LAMBERT Division: ENGINEERING During review of the subject submittal, it was found that the following information, corrections, or clarifications would need to be addressed. All Handouts referred to in these comments can be accessed at our website: www.ci.edmonds.wa.us under City Government / Development Services Department / Engineering Division then scroll down to Handouts: st 1 Review – 8/24/10 nd 2 Review – 10/14/11 rd 3 Review – 5/3/12 (Comment to Questions) th 4 Review – 7/13/12 7/13/12 – Comment was partially addressed. 1) a.If a vault is to be installed, please submit engineering calculations. b.Please relocate the vault under the asphalt, so that you are not adding more impervious surfaces to the site. c.Or use the standard pipe plan for a category 1 site. d.For any pipe that is under a driveable surface, 2’ of cover is required or ductile iron or N12 can be used with 1’ of cover. e.Please show rim and invert elevations for all catch basins both on private property and within the right-of-way. 10/14/11 - There must be access to the detention system (cleanout is too small). f.Please show a type II catch basin at each end of the detention pipe. g.If the installation of the cacth basins change how the surface water runoff is being collected, please revise the plans to show how all runoff will be collected. DATE E-MAILED 7/13/2012 PAGE(1) City of Edmonds BLD20100561 TH 121 5 AVENUE NORTH EDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221 Website: www.ci.edmonds.wa.us PUBLIC WORK DEPARTMENT Planning • Building • Engineering Engineering Plan Review Comments 7/13/12 – Comment was partially addressed. Plans show a 4” pipe within the right-of-way. 2) a.The pipe within the right-of-way must be 12”. b.There can not be any bends in the pipe that is located in the right-of-way. c.For any pipe that is under a driveable surface within the right-of-way, 2’ of cover is required or ductile iron can be used with 1’ of cover. 10/14/11 Comment - The storm system outfall pipe (from the detention system to the city system) cannot be approved as shown on the plans. d.Any run of the storm pipe within the city ROW shall be 12”. th e.12” storm pipe shall run from a catch basin on the north side of 218 and connect to a catch th basin on the south side of 218. Revise plans to show installation of additional catch basins as needed. th f.Show connection of private storm system outfall to the catch basin on the north side of 218 St SW. 7/13/12 – Comment partially addressed. We must see the water service line from the house to the 3) meter on the drainage plan. 10/14/11 Comment - Please show the existing water service line from the house to the meter. 7/13/12 – Comment partially addressed. We must see the side sewer from the house to the main 4) on the drainage plan. 10/14/11 Comment - Please show the existing side sewer from the house to the main. 7/13/12 – Comment not addressed. 5) 10/14/11 Comment - Please add a note that all disturbed soils will be compost amended (see attached handout E72C). Please resubmit 3 copies of the revised traffic control plans and associated documents with a written response to each item to an Engineering Technician. Please contact me at 425-771-0220 ext 1321 or by e- mail at jennifer.lambert@ci.edmonds.wa.us if you have specific questions regarding these plan corrections. DATE E-MAILED 7/13/2012 PAGE(1)