BLD20100761.pdfOt' EDM
STATUS: ISSUED 11/12/2010
Expiration Date: 11/12/2011
Parcel No: 00580700000202
CITY OF EDMONDS
121 5TH AVENUE NORTH - EDMONDS,WA 98020
PHONE: (425) 771-0220 - FAX: (425) 771-0221
Permit'#c BLD20100701
BUILDING PERM IT
Project "r'ei ssi 7219 243THf"PL SW #BLD'G B 1
z EDMONDS
PRO PE&TY*NN'N Ell -CONTRACTOR
APTS LLC PARK -212 RAM JACK NORTHWEST, LLC RAM JACK NORTHWEST, LLC
219 E GARFIELD ST SUITE 600 1110 SW 142ND ST 1 110 SW 142ND ST
SEATTLE, WA 98102- BURIEN, WA 98166- BURIEN, WA 98166-
(206) 276-5275 Ext. (206) 242-5225 Ext. (206) 242-5225 Ext.
LICENSE #: RAMJAJN943K4 EXP:5/24/2012
FOUNDATION STABILIZATION
VALUATION: $35,000
PERMIT TYPE: Commercial
PERMIT GROUP: 53 - Repair Structural
GRADING: N CYDS: 0
TYPE OF CONSTRUCTION:
RETAINING WALL ROCKERY: N
OCCUPANT GROUP:
OCCUPANT LOAD:
FENCE: N ( 0 X 0 FT.)
CODE: 09
OTFIER: N ------- OTHER DESC:
ZONE: CG
NUMBER OF STORIES: 0
VESTED DATE:
NUMBER OF DWELLING UNITS: 0
LOT #:
BASEMENT: 0 1 ST FLOOR: 0 2ND FLOOR: 0
BASEMENT: 0 1 ST FLOOR: 0 2ND FLOOR: 0
3RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0
PRD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0
REQUIRED: PROPOSED: REQUIRED: PROPOSED: REQUIRED: PROPOSED:
HEIGHT ALLOWED:O PROPOSED:O REQUIRED: PROPOSED:
SETBACK NOTES: PROJECT >400' FROM STEEP SLOPE.
1 AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONST RUCTION AND IN DOING THE WORK AUTHORIZED
THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO
WORKMEN'S COMPENSATION INSURANCE AND RCW 18:27,
THIS -APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PMD.
S!�, --714 U⁣' 7w & Ld'h 0
Signature Print Name Date Released By Date
ATTENTION
ITIS UNLAWFUL TO USE OROCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL ORA CERTIFICATE OF
OCCUPANCY HAS BEEN GRANTED. UBC109/ IBCI 10/ IRCI 10.
= ONLINE = APPLICANT = ASSESSOR (OTHER
a
STATUS: ISSUED
BLD20100761
• Special inspections have been called for on this project and are noted on the approved construction plans and building permit.
It is the owner and/or contractors responsibility to assure that reports are provided to the City on a weekly basis. Be advised—
if special inspection reports are not forthcoming, the Building Official may issue a "Stop Work" and no City inspections will be
provided until such time as the reporting agency has complied and reports are reviewed and approved by the City.
* Welding
* Helical Piers
• Final approval on a project or final occupancy approval must be granted by the Building Official prior to use or occupancy of
the building or structure. Check the job card for all required City inspections including final project approval and final
occupancy inspections.
• Any request for alternate design, modification, variance or other administrative deviation (hereinafter "variance") from
adopted codes, ordinances or policies must be specifically requested in writing and be called out and identified. Processing
fees for such request shall be established by Council and shall be paid upon submittal and are non-refundable.
Approval of any plat or plan containing provisions which do not comply with city code and for which a variance has not been
specifically identified, requested and considered by the appropriate city official in accordance with the appropriate provision
of city code or state law does not approve any items not to code specification.
• Sound/Noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits
of ECC Chapter 5.30 only during the hours of7:00amto 6:00pmon weekdays and 10:00amand 6:00pmon Saturdays, excluding
Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the
noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120.
• Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold
harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of
whatever nature, arising directly or indirectly from the issuance for this permit. Issuance of this permit shall not be deemed to
modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance
provision.
THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE
PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION.
PERMIT TIME LIMIT: SEE ECDC 19.00.005(A)(6)
BUILDING (425) 771-0220 EXT. 1333 1 >!TIGMMU NG (425) 771-0220 EXT. 1326 1 FIRE (425) 775-7720
PUBLIC WORKS 425) 771-0235 1 PR&TREATMFINT 425 672-5755 1 RECYCLING 425 275-4801
When calling for an inspection please leave the following information: Permit Number, Job Site Address, Type of Inspection being
requested, Contact Name and Phone Number, Date Prefereed, and whether you prefer morning or afternoon.
• B -Framing.
• B -Building Final
• X -Special Inspection
of FDMO
SPECIAL INSPECTION AND TESTING AGREEMENT
Permit #: ' tow- o-ibt Project: -7yat -ztV4 D%- sN: ►�
Est, 1 Seo
Prior to issuance of a permit, this form must be completed in its entirety and returned to the Cityfor
approval The completed form must have signatures of acknowledgment by all parties.
DUTIES AND RESPONSIBILITIES
Special Inspection Firm and Special Inspectors: L
The Special Inspection firm of L l q A S S o e.1G es , Tvi e- • will perform special
inspection for the following types of work (separate forms must be submitted if more than one firm is to be
employed):
❑ Reinforced Concrete
❑ Bolting in Concrete
❑ Prestressed Concrete
❑ Shotcrete
❑ Structural Masonry
XStructural Steel/Welding
❑ High Strength Bolting
❑ Spray applied Fireproofing
❑ Smoke Control,Systems
❑ Lateral Wood
❑ Structural Observation
❑ Grading/soils
V Other AEWNN• P%ZG 5
❑ Other
All individual inspectors to be employed on this project will be WABO certified for the type of work they are to
inspect. If inspection is for work that is not covered by the WABO categories, or the inspector is not WABO
certified, a detailed resume of the inspector and firm must be submitted. The resume must show that the
inspector and the firm are qualified by education and experience to perform the work and testing required by the
project design and specifications.
The work shall be inspected for conformance with the plans and specifications approved by the City. Revisions
and addenda sheets will not be used for inspection, unless they have been approved by the City. Inspection
records shall include:
• A daily record to be maintained on site, itemizing the inspections performed. Any nonconforming work
shall be brought to the immediate attention of the contractor for resolution.
• A weekly report shall be submitted to the City; detailing the inspections a4d testing performed, listing
any nonconforming work and resolution of nonconforming items.
• A final report shall be submitted to the building department prior to the Certificate of Occupancy being
issued. This report will indicate that inspection and testing was completed in conformance with the
approved plans, specifications and approved revisions or addenda. Any unresolved discrepancies must
be detailed in the final report.
Contractor:
The contractor shall provide the special inspector or agency adequate notification of work requiring inspection.
The City approved plan and specifications must be made available, at the jobsite for the use of the special
inspector and the City inspector. The contractor shall maintain all daily inspection reports, on site, for review by
all parties.
The special inspection functions are considered to be in addition to the normal inspections performed by the City
and the contractor is responsible for contacting the City to schedule regular inspections. No concrete shall be
poured or other work covered until approval is given by the City inspector.
Building Department:
The building department shall review any revisions and addenda. The City inspector will monitor the special
inspection functions for compliance with the agreement and the approved plans. The City inspector shall be
responsible for approving various stages of construction to be covered and for work to proceed.
Design Professionals:
The architect and/or engineer will clearly indicate on the plans and specifications the specific types of special
inspection required. and shall include a schedule for inspection and testing. The architect and/or engineer will
coordinate their revision and addenda process in such a way as to insure that all required City approvals are
obtained, prior to work shown on the revisions being performed in the field.
Owner:
The project owner, or the architect or engineer acting as the owners agent, shall employ the special inspector or
agency.
ENFORCEMENT
A failure of the special inspector or firm to perform in keeping with the requirements of the IBC, the approved
plans and this document, may void this agreement and the Building Official's approval of the special inspector.
In such a case a new special inspector and/or firm would need to be proposed for approval. A failure of the
design and/or construction parties to perform in accordance with this agreement may result in a STOP WORK
notice being posted on the project until nonconforming items have been resolved.
I have read and agree to comply with the terms and conditions of
er: jAif/ !%044,��llg714% Signature
Contractor: 1-4 --.�5?44, �� 4:. Signature
-;5Lt;v
Arch./Eng: (, I��- SS 0 C t ATC ay-sjgnature
� /1F) i
' •
Special Insp. ilk X3 AW41 tM Signature Date:
ACCEPTED FOR THE CITY OF EDMONDS BUILDING DEPT.
By: Z/ Date: Q
of r.o,yU
° SPECIAL INSPECTION AND TESTING AGREEMENT
Per mit #: Project: -?Ztq-zt-3^� P� sVJ i ►g� S?i
Prior to issuance of a permit, this form must be completed in its entirety and returned to the. City for
alpproval. The completed form. must have signatures of acknowledgmeni by all parties.
DUTIES AND RESPONSIBILITIES
Special Insyection.FYrm and Special Inspectors:
1 L �i
The Special Inspection firm of L A S 5 o c. trk�es 1 C, will perform special
inspection for the following types of tivoric (separate forms must be sub4.�mitter( if more. than one firm is to be
employed):
❑ Reinforced Concrete
❑ Bolting in Concrete
❑ Prestressed Concrete
❑ Shotcrete
❑ Structural Masonry
19 Structural Steel/Welding
❑ I.1igh Strength Bolting
0 Spray applied Fireproofing
❑ Smoke Control Systems
❑ Lateral Wood
❑ Structural Observation
❑ Grading/soils
VOther Ar%-%oo --
❑ Other
All individual inspectors to be employed on this project will be WABO certified for the type of work they are to
inspect. If inspection is for work that is not covered by the WABO categories, or the inspector is not WABO
certified, a detailed resume of the inspector and firm must be submitted. The resume must show that the
inspector and the firm are qualified by education and experience to perform the work and testing required by the
project design and specifications.
The work. shall be inspected for conformance with the plans and specifications approved by the City. Revisions
and addenda sheets will not be used for inspection, unless they have been approved by the City. Inspection
records shall include:
• A daily record to be maintained on site, itemizing the inspections performed. Any nonconforming work
shall be brought to the immediate attention of the contractor for resolution.
• A weekly report shall be submitted .to the City; detailing the inspections aAd testing performed, listing
any nonconforming work and resolution of nonconforming items.
• A final report shall be submitted to the building department prior to the Certificate of Occupancy being
issued. This report will indicate, that inspection and testing was completed in conformance with the
approved plans, specifications and approved revisions or addenda. Any unresolved discrepancies .must
be detailed in the final report.
RECEIVEE)
NOV 0 3 2010
DEVELOPMENT CM COPY CTR.
CITY OF EDMONDS
Contractor:
The contractor shall provide the special inspector or agency adequate notification of work requiring inspection.
The City approved plan and specifications must be made available, at the jobsite for the use of the special
inspector and the City inspector. The contractor shall maintain all daily inspection reports, on site, for review by
all parties.
The special inspection functions are considered to be in addition to the normal inspections performed by the City
and the contractor is responsible for contacting the City to schedule regular inspections. No concrete shall be
poured or other work covered until approval is given by the City inspector.
Building Department:
The building department shall review any revisions and addenda. The City inspector will monitor the special
inspection functions for compliance with the agreement and the approved plans. The City inspector shall be
responsible for approving various stages of construction to be covered and for work to proceed.
Desien Professionals:
The architect and/or engineer will clearly indicate on the plans and specifications the specific types of special
inspection required. and shall include a schedule for inspection and testing. The architect and/or engineer will
coordinate their revision and addenda process in such a way as to insure that all required City approvals are
obtained, prior to work shown on the revisions being performed in the Geld.
Owner
The project owner, or the architect:or engineer acting as the owners agent, shall employ the special inspector or
agency.
ENFORCEMENT
A failure of the special inspector or firm to perform in keeping with the requirements of the II3C, the approved
plans and this document, may void this agreement and the Building Official's approval of the special inspector.
In such a case a new special inspector and/or firm would need to be proposed for approval. A failure of the
design and/or construction parties to perform in accordance with this agreement may result in a STOP WORK
notice being posted on the project until nonconforming items have been resolved.
ACKNO'WLEDGME S
1 have read and agree to comply with the terms and conditions of t s a cxti
d�/ f47�r
, diartj Signature Date 9Ila
r 4
Contractor: -��_&J. Signature Date:
. a. -tu
ignature Date: 8 $ It D
Special Insp. tAO-Z !L5 A74iSignature Date:
ACCEPTED FOR THE CITY OF EDMONDS BUILDING DEPT.
By: Date: AW/0
RECEIVED
NOV 0 3 2010
DEVELOPMENT SERVICES CTR.
CITY OF EDMONDS
LIU & ASSOCIATES, INC.
Geotechnical Engineering Engineering Geology Earth Science
April 7, 2010
Mr. T. J. Waterman
Epic Asset Management
219 East Garfield Street, Suite 600
Seattle, WA 98006
Dear Mr. Waterman:
Subject: Geotechnical Investigation and Foundation Stabilization
Building B — 212'' Place Apartments
7219 - 213th Place SW
Edmonds, Washington
L&A Job No. 10-009
INTRODUCTION
At your request, we have completed a geotechnical investigation of the foundation
distress problem sustained by Building B of the subject apartment complex, located at the
above address in Edmonds, Washington. We understand that the a load bearing wall and
adjacent floor slabs in the southern portion of the subject building has experienced
settlement. The purpose of this investigation is to characterize the subsurface conditions
under this building, evaluate causes of its foundation distress, and provide
recommendations and design for the foundation stabilization of the bearing wall and
slabs. Presented in this report are our findings, conclusions and recommendations.
SCOPE OF SERVICES
To achieve the above purpose, the scope of our services for this investigation specifically
comprises the following:
CITY �Opy OCT 1 5 2010
DEVELOPMENT SERVICES CTR.
19213 Kenlake Place NE - Kenmore, Washington 98028 CITY OF EDMONDS
Phone (425) 483-9134 - Fax (425) 486-2746
April 7, 2010
Foundation Stabilization
Building B — 212'h Place Apartments
L&A Job No. 10-009
Page 2
1. Review geologic and soil conditions at the subject apartments site based on a
published geologic map.
2. Visit the subject building and observe the conditions of the building and its
surrounding area.
3. Explore the subsurface condition under the building with test borings drilled to a
firm bearing soil stratum into which foundations can be installed to support the
settled bearing wall.
4. Perform geotechnical engineering analyses as required and provide geotechnical
recommendations for foundation stabilization design.
5. Prepare a written report to present our findings, conclusions and
recommendations for foundation stabilization of the subject building.
SITE CONDITIONS
SURFACE CONDITIONS
The general location of the subject apartment complex is shown on Plate 1 - Vicinity
Map, attached hereto. The apartment complex site is partially bounded by 212'h Street
SW to the north and 72"d Avenue West to the east, and is adjoined by residential
developments to the south and west. The subject building is situated on gently sloped
ground surrounded by paved parking lots. The parking lot to the south of the building
rises a few feet above the building pad of the subject building with a slope descending
from the northern edge of the parking lot to within a few feet of the building.
GEOLOGIC SETTING
The Geology Man of the Edmonds West and Part of the Edmonds East Quadrangles,
Snohomish and King Counties, Washington, by James P. Minard, published in 1983 by U.
LIU & ASSOCIATES, INC.
April 7, 2010
Foundation Stabilization
Building B — 212'h Place Apartments
L&A Job No. 10-009
Page 3
S. Geological Survey, was referenced for the geologic and soil conditions at the subject
building site. According to this publication, the surficial soil unit at and in the vicinity of
the site is mapped as Vashon Till (Qvt) underlain by Advance Outwash (Qva)•
The geology of the Puget Sound Lowland has been modified by the advance and retreat of
several glaciers in the past and subsequent deposits and erosion. The latest glacier
advanced to the Puget Sound Lowland is referred to as the Vashon Stade of the Fraser
Glaciation, which has occurred during the later stages of the Pleistocene Epoch and
retreated from the region some 14,500 years ago.
The Vashon till soil unit was plowed directly under glacial ice during the most recent
glacial period as the glacier advanced over an eroded, irregular surface of older
formations and sediments. It is composed of a mixture of unsorted clay, silt, sand, gravel,
and scattered cobbles and boulders. The Vashon till soils over the top two to four feet are
normally weathered to a medium -dense state, and is moderately permeable and
compressible. The underlying fresh till soils are very dense, and are commonly referred
to as "hard pan". They are practically impervious to stormwater infiltration. The fresh till
soils possess a shear strength similar to that of low-grade concrete and can stand in steep
natural slopes or man -make cuts for a long period. If remained undisturbed and well -
drained, the fresh till soils can provide excellent foundation support to structures with
little settlement expected.
The advance outwash soil unit is composed of stratified sand and gravel with minor
amounts of silt and clay, deposited by the meltwater of advancing glacial ice. Due to their
LIU & ASSOCIATES, INC.
April 7, 2010
Foundation Stabilization
Building B — 212`h Place Apartments
L&A Job No. 10-009
Page 4
generally granular composition, the advance outwash deposits are of moderately high
permeability and drains fairly well. The advance outwash deposits were glacially
overridden and are generally dense to very dense in its natural, undisturbed state, except
the soils in the top 2 to 4 feet exposed on slopes which may be in a loose to medium -
dense state from erosion and weathering. The advance outwash deposits can stand in
steep cuts or natural slopes for extended period when undisturbed. The advance outwash
deposits in their native, undisturbed state can provide good foundation support with little
settlement expected for light to moderate residential structures.
We understand that the apartment complex site is at least partially built over an old gravel
pit that was subsequently backfilled for the development of the apartment complex. The
previous existing gravel pit is an indication that the Vashon till layer, if any, was
relatively thin over the apartment complex site and that the advance outwash soil unit
must have lied at relatively shallow depth under the site to make the gravel pit operation
feasible.
SOIL CONDITION
Subsurface conditions under the subject building were explored on February 24, 2010,
with two test borings. The test borings were drilled to 21.5 and 20.0 feet deep with a
portable drill rig from inside the building. The approximate locations of the test borings
are shown on Plate 2 — Foundation and Exploration Location Plan.
Soil samples obtained from the test borings were visually classified in general accordance
with United Soil Classification System, a copy of which is presented on Plate 3. An
LIU & ASSOCIATES, INC.
April 7, 2010
Foundation Stabilization
Building B — 212`h Place Apartments
L&A Job No. 10-009
Page 5
engineering geologist from our office was present during the exploration, who examined
the soil samples retrieved from the test borings and the soil and geologic conditions
encountered, and completed logs of test borings. Detailed descriptions of the soils
encountered during site exploration are presented in test boring logs on Plates 4 and 5.
Both test borings encountered a layer of loose to very -loose fill from 17.75 to 19.5 feet
deep underneath the on -grade floor slab of the subject building. The fill contains
occasional wood fragments, chunks of asphalt, plastic wire and organics in gravelly sand,
silty sand and silt matrices. According to the driller, the fill may also contain cobble and
boulder on which the drill rod was deflected laterally off plumbness to some degree
during drilling of the test borings. The fill material appears to have been used to backfill
an old gravel pit under the subject apartment complex site, but was not properly placed
and adequately compacted. Underlying the fill to the depths explored is a medium -dense
to very -dense, sand to gravelly sand deposit which appeared to be an advance outwash
deposit.
GROUNDWATER CONDITION
Groundwater was not encountered by either of the two test borings drilled under the
subject building. The loose fill and the underlying advance outwash sand deposit are of
moderately high to high permeability, and would allow stormwater to seep through easily.
The infiltrating stormwater would perch on an impervious fine-grained soil unit
underlying the advance outwash soil unit. This perched groundwater would be at such
LIU & ASSOCIATES, INC.
April 7, 2010
Foundation Stabilization
Building B — 212`h Place Apartments
L&A Job No. 10-009
Page 6
greater depth that it should have little impact on the foundation stabilization construction
work.
FOUNDATION DISTRESS
The load bearing wall in the southern portion of the subject building has settled about 2 to
3 inches. The concrete floor slabs abutting this load bearing wall have also subsided and
resulted in cracks in the floor slabs.
CAUSES OF FOUNDATION DISTRESS
The fill used to backfill the old gravel pit over which the subject building is at least
partially constructed is composed of very -loose to loose sand and silt soils mixed with
occasional wood fragments, debris, organics, chunks of asphalt, and possible cobbles and
boulders. Such fill not properly constructed and inadequately compacted would
consolidate under its own weight and the foundation load of the building. This is the
main reason for the settlement and subsidence of the bearing wall and the floor slabs.
Also, the load bearing wall of the subject building appears to have been constructed
without or with a significantly under -sized footing foundation. This would further
aggravate the settlement problem of the load bearing wall.
GENERAL
FOUNDATION STABILIZATION RECOMMENDATIONS
LIU & ASSOCIATES, INC.
April 7, 2010
Foundation Stabilization
Building B — 212'' Place Apartments
L&A Job No. 10-009
Page 7
The settled load bearing wall inside the subject building should be underpinned to prevent
it from further settlement. The portion of subsided and cracked on -grade floor slabs
adjacent to this bearing wall should be saw -cut along the cracks and reconstructed with
steel bar reinforced concrete slabs. Limited by overhead clearance inside the building, we
recommend the bearing wall foundation be underpinned and stabilized with helical piers.
According the available design plans of the subject building, the edge of the concrete
floor slab abutting the south side of the bearing wall is thickened to support a load-
bearing stud wall. To underpin this stud bearing wall, the wood floor system above the
slab should be temporarily shored to allow the stud wall to be cut off and the
underpinning construction work to proceed.
Before reconstructing the subsided and cracked floor slabs, the subgrade soils underneath
the slabs should be over -excavated by at least 24 inches with the over -excavation
backfilled with compacted structural fill topped by a 6 -inch ' layer of crushed rock base.
The new slabs should be connected to the bearing wall and the remaining slabs with
dowel bars.
HELICAL PIERS
Helical piers consist of assemblies of a lead section and added -on extension bars that can
be screwed into the ground with a drill head. They are commercially available from A. B.
Chance Company or Earth Contact Products. The lead section is made of single or
multiple steel helical flights welded onto a square steel bar. The drill head used for
LIU & ASSOCIATES, INC.
April 7, 2010
Foundation Stabilization
Building B — 212th Place Apartments
L&A Job No. 10-009
Page 8
installing helical piers is portable and is connected by hydraulic lines to a hydraulic power
unit which can be placed at an convenient spot within the apartment complex site. The
lead section is twisted into the ground with a drill head with extension bars added as
required to advance and seat the lead section into a firm bearing soil stratum capable of
supporting the structure to be underpinned. The detail and installation of helical piers to
underpin the bearing wall, is shown on Plate 6.
The helical piers should be installed to penetrate through the loose fill and seated into the
underlying dense to very -dense, fresh advance outwash soils. The bearing capacity of
helical piers is closely related to the amount of torque required to turn and advance the
helical assemblies into the ground. The ultimate bearing capacities for helical piers
should not be greater than manufacturer's recommended values based on the average
torque readings for advancing the helical assemblies the last foot. Depending on the type
of soils and the number and size of helices of the lead section, helical piers can develop
an allowable compressive bearing capacity of 4 to 15 tons. We estimate that a helical pier
with a lead section of a 8 -inch and an 10 -inch helices penetrating into the underlying
dense advance outwash soils underlying the fill can develop an allowable bearing
capacity of 12 tons or more per each.
The spacing of the helical piers, however, may be governed by the strength of the
concrete stemwalls. Therefore, the bearing wall may have to be reinforced and one of the
ways to reinforce the bearing wall is to have the bearing wall sandwiched in steel
reinforced shotcrete walls doweled into the bearing wall, as shown on Plate 6.
LIU & ASSOCIATES, INC.
April 7, 2010
Foundation Stabilization
Building B — 212th Place Apartments
L&A Job No. 10-009
Page 9
HELICAL PIER TO BEARING WALL CONNECTIONS
The helical piers should be securely connected to the concrete bearing wall to transfer the
load from the wall to the helical piers. One way to make the connections is shown on
Plate 6, with a section of structural tubing welded onto the caps of the helical piers then
bolted onto the bearing wall with dower bars.
LONG-TERM CORROSION PROTECTION
For long-term protection against corrosion, the helical piers and their accessories should
be galvanized. Any structural steel shapes and plates used should either be galvanized or
coated with protective paint.
STRUCTURE RE -LEVELING
After all helical piers and helical anchors are in place, the settled bearing wall may then
be lifted and re -leveled, if so desired, by jacking up the bearing wall. It should be
understood that lifting and re -leveling a structure may cause additional structural
damages, and is a risk which should be considered by the owner of the property whether
to proceed with the lifting and re -leveling of settled bearing wall. Extreme care should be
exercised by the contractor in lifting and re -leveling the bearing wall in order to minimize
such damages. The lifting loads should be applied at a very slow rate and by alternating
points of lifting to achieve a gradual and uniform raise, and the movement of the bearing
wall should be closely monitored with an optical instrument or other approved method.
LIU & ASSOCIATES, INC.
April 7, 2010
Foundation Stabilization
Building B — 212'' Place Apartments
L&A Job No. 10-009
Page 10
BID TENDERING
We estimate the average length of the pin piles or helical piers would be about 30 feet
from their cutoff point to the tip. The contractor's base bid should be based on this
estimated average length. The actual lengths of helical piers may vary pending on the
actual soil conditions encountered in the field while the piers are being installed until
required bearing capacity is achieved. Unit prices per lineal foot of helical piers for
addition and deduction should be provided by the contractor in his/her bid for adjusting
his/her base bid price. The total final contract price should be calculated based on the
actual total lengths of helical piers installed.
LIMITATIONS
This report has been prepared for the specific application to the stabilization of the
settling load bearing wall and subsiding floor slabs in the subject building for the
exclusive use of Epic Assets Management and their representatives, consultants and
contractors. We recommend that this report, in its entirety, be included in the project
contract documents for the information of the prospective contractors for their estimating
and bidding purposes and for compliance of recommendations in this report during
construction. The conclusions and interpretations in this report, however, should not be
construed as a warranty of the subsurface conditions. The scope of this study does not
include services related to construction safety precautions and our recommendations are
not intended to direct the contractor's methods, techniques, sequences or procedures,
except as specifically described in this report for design considerations.
LIU & ASSOCIATES, INC.
April 7, 2010
Foundation Stabilization
Building B — 212th Place Apartments
L&A Job No. 10-009
Page 11
Our conclusions and recommendations are based on the soil conditions encountered by
the test borings drilled under the subject building. Actual soil conditions encountered
during construction may vary. When varying subsurface conditions are encountered, we
should be informed to review and revise our remedial recommendations as required. The
conclusions and recommendations are professional opinions derived in a manner
consistent with the level of care and skill ordinarily exercised by other members of the
profession currently practicing under similar conditions in this area. No warranty,
expressed or implied, is made.
CLOSURE
We are pleased to be of service to you on this project. Please feel free to contact us if you
have any questions regarding this report or need further consultation.
Seven plates attached
Yours very truly,
LIU & ASSOCIATES, INC.
J. S. (Julian) Liu, Ph.D., P.E.
Consulting Geotechnical Engineer
LIU & ASSOCIATES, INC.
VICINITY MAP
LIU & ASSOCIATES, INC. 212TH PLACE APARTMENTS
7219 - 213TH PLACE SW
Geotechnical Engineering • Engineering Geology - Earth Science EDMONDS, WASHINGTON
JOB
r
LIU & ASSOCIATES, INC.
Geotechnical Engineering - Engineering Geology - Earth Science
�- 7N iGKE�J ED
L_ sL-pe
J
J
FOUNDATION & EXPLORATION LOCATION PLAN
BUILDING B - 212TH PLACE APARTMENTS
7219 - 213TH PLACE SW
EDMONDS, WASHINGTON
UNIFIED SOIL CLASSIFICATION SYSTEM
MAJOR DIVISIONS
GROUP
GROUP NAME
SYMBOL
GRAVEL
CLEAN
GW
WELL-GRADED GRAVEL, FINE TO COARSE GRAVEL
COARSE-
MORE THAN 50% OF
GRAVEL
GP
POORLY-GRADED GRAVEL
GRAVEL WITH
GM
SILTY GRAVEL
GRAINED
COARSE FRACTION
SOILS
RETAINED ON NO.4 SIEVE
FINES
GC
CLAYEY GRAVEL
SAND
CLEAN
SW
WELL-GRADED SAND, FINE TO COARSE SAND
MORE THAN 50%
MORE THAN 50% OF
SAND
SP
POORLY-GRADED SAND
SAND WITH
SM
SILTY SAND
RETAINED ON THE
COARSE FRACTION
NO.200 SIEVE
PASSING NO.4 SIEVE
FINES
SC
CLAYEY SAND
FINE-
SILT AND CLAY
INORGANIC
ML
SILT
CL
CLAY
GRAINED
LIQUID LIMIT
SOILS
LESS THAN 50%
ORGANIC
OL
ORGANIC SILT, ORGANIC CLAY
SILTY AND CLAY
INORGANIC
MH
SILT OF HIGH PLASTICITY, ELASTIC SILT
MORE THAN 50%
CH
CLAY OF HIGH PLASTICITY, FAT CLAY
PASSING ON THE
LIQUID LIMIT
NO. 213D SIEVE
50% OR MORE
ORGANIC
OH
ORGANIC SILT, ORGANIC SILT
HIGHLY ORGANIC SOILS
PT
PEAT AND OTHER HIGHLY ORGANIC SOILS
NOTES: SOIL MOISTURE MODIFIERS:
1. FIELD CLASSIFICATION IS BASED ON VISUAL EXAMINATION DRY - ABSENCE OF MOISTURE, DUSTY, DRY TO
OF SOIL IN GENERAL ACCORDANCE WITH ASTM D2488-83. THE TOUCH
2. SOIL CLASSIFICATION USING LABORATORY TESTS IS BASED SLIGHTLY MOIST - TRACE MOISTURE, NOT DUSTY
ON ASTM D2487-83. MOIST - DAMP, BUT NO VISIBLE WATER
3. DESCRIPTIONS OF SOIL DENSITY OR CONSISTENCY ARE VERY MOIST- VERY DAMP, MOISTURE FELT TO THE TOUCH
BASED ON INTERPRETATION OF BLOW-COUNT DATA, VISUAL WET - VISIBLE FREE WATER OR SATURATED,
APPEARANCE OF SOILS, AND/OR TEST DATA. USUALLY SOIL IS OBTAINED FROM BELOW
WATER TABLE
LIU & ASSOCIATES, INC.
UNIFIED SOIL CLASSIFICATION SYSTEM
PLATE 3
Geotechnical Engineering • Engineering Geology • Earth Silence
BORING NO. B-1
Logged By: MK 2242010 Ground Elev. t
Depth
Sample
(N)
W
USCS
Soil Description
Blows/
Other Test
ft.
T
No.
ft.
%
SP
Dark -brown, very loose, SAND with trace organics, moist
t
(FILL)
SS
1
2
3
SP
Brown, loose, gravelly SAND, with some sift and organics,
moist (FILL)
SS
2
7
4
5
s
SM
Grayish -brown, dense, silty SAND, with gravel, moist (FILL)
SS
3
37
(High blow count may be from sampler blocked by gravel)
7
8
SM
Dark -brown to reddish -brown, very loose, silty SAND, with
SS
4
3
9
gravel and charcoal, moist (FILL)
10
11
SM
Dark -brown, very loose, silty SAND, with gravel and wood
SS
5
4
fragments and piece of plastic wire, moist (FILL)
12
13
SP
Gray, loose, gravelly SAND, moist (FILL) (gravel in tip of
sampler)
SS
6
8
14
15
18
No recovery, very loose soil
SS
7
4
17
18
19
-----------------------------------------------
20
20
----
-------------------------------------
SP
Gray, very dense, SAND with gravel, moist
21
(ADVANCE OUTWASH)
SS
8
>50
Test borin terminated 21.5 ft roundwater not encountered
SS - 2" O.D. Split -Spoon Sample GROUNDWATER: Seal
rLEGEND:
ST - 3" O.D. Shelby -Tube Sample Water Level
B - Bulk Sample Observation Well Ti
BORING LOG
LIU & ASSOCIATES, INC.
212TH PLACE APARTMENTS - BUILDING B
7219 - 213TH PLACE SW
EDMONDS, WASHINGTON
GeotachnkelEngineering • Engineering Geology • Earth Science
JOB NO. 10209 1 DATE 3262010 PLATE 4
BORING NO. B-2
Logged By: MK 2242010 Ground Elev. t
Depth
Sample
(N)
W
USCS
Soil DescriptionN
Blows/
Other Test
ft.
T
No.
ft.
%
SP
Brown, loose SAND, with gravel, moist (FILL)
1
SS
1
2
3
4
5
SM
Dark brown, medium dense, silty SAND, with gravel and
e
roots with a one inch piece of asphalt, moist (FILL)
SS
2
11
7
8
e
.
10
Piece of concrete in tip of sampler (FILL)
11
(high blow count may not be true represenatlon of soil densitty)
SS
3
19
12
13
14
15
OL
Dark brown, very stiff, organic SILT with pieces of gravel
18
and blue colored fabric, moist (FILL) (high blow count
SS
4
22
may not be true represenation of soil densilty)
17
18 --------
-------------------------------------
19
'SP
Brownish gray, medium dense, SAND, moist
SS
5
15
20
ADVANCE OUTWASH
21
Test boring terminated @ 20.0 ft, groundwater not encountered.
22
LEGEND: SS - 2" O.D. Split -Spoon Sample GROUNDWATER: Seal
ST - 3.O.D. Shelby -Tube Sample Water Level
B - Bulk Sample r I Observation Well Ti
BORING LOG
LIU & ASSOCIATES, INC.
212TH PLACE APARTMENTS - BUILDING B
7219 - 213TH PLACE SW
EDMONDS, WASHINGTON
Geotechnical Engineering • ErgineeftGeology • Earth Science
JOB NO. 10-009 I DATE 3262010 1 PLATE 5
. I .
j�67E
o2Sf q v\ '�
r0e4a
LIU & ASSOCIATES, INC.
Geotechnical Engineering - Engineering Geology - Earth Science
pv�
ST2uGTup,p'l.-
& hl ->0Y1 N C1
NEyC.aL-
fiERs (YYP)
PIER / WALL CONNECTION
BUILDING B - 212TH PLACE APARTMENTS
7219 - 213TH PLACE SW
EDMONDS, WASHINGTON
LIU & ASSOCIATES, INC. Project_
Geotechnical Engineeriiig • Engineering Geology • Earth Sc;"nce
19213 KENLAKE PLACE NE KENMORE, WA 98028
PHONE: (425) 483-9134 FAX: (425) 486-2746
- Date Ck'd by
DESIGN CALCULATIONS
FOUNDATION STABILIZATION
BUILDING B - PARK 212 APARTMENTS
EDMONDS, WASHINGTON
CITY COPY
RECEIVED
0CT 1 5 208.1
DEVELCTY 0f DRON78 GTR.
_ Sheet No. ___ of I
_ Prop. No.
Job No
— Date
LIU & ASSOCIATES, INC.
Geotechnical Engineering • Engineering Geology • Earth Science
19213 KENLAKE PLACE NE KENMORE, WA 98028
PHONE: (425) 483-9134 FAX: (425) 486-2746
Project Sheet No. L of
P��K 212 UILDIt�C� Prop. No.
��1 fJ D�Ti v �l ST,QgI I �A7orl
Job No -10-601
ByJ -SL—Date Ck'd by Date
f;oUr\]oATiot! PLAt
/- 2x4 �S/a5E
1,( PhiP of 2x4 (P�o.ck-4-n F3a�k,-rf
•TYP) �,/s.Kl cel C� (,�p.LrL DG7"At �
1
J
o (Tyr-,>)
LIU & ASSOCIATES, INC.
Geotechnical Engineering • Engineering Geology • Earth Science
19213 KENLAKE PLACE NE KENMORE, WA 98028
PHONE: (425) 483-9134 FAX: (425) 486-2746
SIE L I Cwt. P1�25
Project Sheet No. Z of 3
Pa►zK ?-(2-
Prop. No.
O QATI o r STASI L (KATp�
By —J SL—Date Ck'd by
Job No 10-609
Date
foo (✓ 15 Psi .. f ZS PSS 4o PS-�... .
lj i2D F L. 2 -f-
4o C,
0
ZN(D l;L Zo -t 40 - �o
PLOo R 5LA6, Zo
7; t ( 90 PS x 10�-
Z l �'
x 6= 144 o-*1C6-x'i Y 0� s
j�SSU �i� NSI IC L- PIES C� �V '( Tf•-IIRD -L)0S,
LOAD
ULTIMATA
-�4-- �-A CTo R OF- SIAFET Y
�T Yr)
I r.
EYP.
LIU & ASSOCIATES, INC. Project I Sheet No.-3of2L
Pe.rz.K Z12 �UILDINU �
Geotechnical Engineering rth engineering Geology •EaScienceProp. No.
1JPA 1 1 0. 1 S,.rTgl L I -�O�
19213 KENLAKE PLACE NE KENMORE, WA 98028 11
PHONE: (425) 483-9134 FAX: (425) 486-2746 Job No_(O- 001
Byj'SL—Date Ck'd by Date
Gt�t`I �GL-(v 2 go (,Ts Ars fu wt..e..P-;our"5
( 44-o /ooLtp- s+j -3.
— �.80#��0.1 f- . S�e�v Fo wc�• ;
2- _2:v j- 5-rdb g L.ARI
1,3 3 3 60 l.T > 8 0
ALLOW. %�Mp(tESSIVL ST.�GSs
a- I�Joo STS p
0i
STee L, be -6,m s o, k
� I
rnc.x 0.3333 (1, q+))
x zi
USS VJ 5-K zl >>
-li>✓LIcA�
MAYESTESTING ENGINEERS, INC
CONCRETE LABORATORY TEST REPORT
Project Name:
212th Apartments
Project No:
Site Address:
7219 213th Place SW
Issued on:
Batch Plant Location:
Edmonds, WA
Sample Set ID
Client:
EPIC Asset Management
Permit # (s):
Engineer:
Liu Associates
Strength (psi) Type of Fracture
Contractor:
Ram Jack Northwest, LLC
01/05/11
Air Temperature: 36°F
Weather:
Snow
Product:
Concrete
Supplier:
Concrete Nor'West
Batch Plant Location:
Sample(s) Rec'd: Required Strength: (f'c)
Ticket Number:
120814
MixDesign ID :
0360040
FIELD DATA
ASTM C31 and C172
Mix Proportions:
Sample Temp. Initial Storage Temp.
Entrained Air
(ASTM C1 (ASTM C31)
(ASTM C231)
e
k`--. 78°F NR
%
Slump (ASTM C143)
Sample(s) Rec'd: Required Strength: (f'c)
5.5"
12/30/10 3000 psi @ 28 days
Placement Location and Notes:
Date Tested
Footings. No batchweights provided.
Size (in) Load (Ibs) Dia (in) Area
Lynnwood
20225 Cedar Valley Road
Suite 110
Lynnwood WA 98036
ph 425.742.9360
fax 425.745.1737
L10517
01/06/11
270513
Remarks:
Technician(s): Hootman, D. RECEIReviewed bv:
Tested by: Cook, B. VED j—; -ea
JAN i 1011 Timothy G. Beckerle, P.E.
DEVELOPMENT S CTR Branch Manager
CRY OF EDMONDS
Notes:
Information in this report applies only to the actual samples tested and shall not be reproduced without the approval of Mayes Testing Engineers, Inc.
See ASTM C39, for full description of the Type of Fracture.
All testing performed in accordance with applicable ASTM's except C-31, 10.1.2, C-780, A MTE 1050-1C, Rev 4, 08/22/07
6.6.1.3, C-1019, 9.6 - "recording field temperature"
COMPRESSION TEST RESULTS
(ASTM C31, C39, C617,
C1231,
C780, C109, C1019 or AASHTO T22 when applicable)
Date Made Sample #
Lab #
Date Tested
Age
Size (in) Load (Ibs) Dia (in) Area
Strength (psi) Type of Fracture
12/29/10 0001
0039
01/05/11
0
4 x 8 F-4.01712.6 3
4580 Type 4
12/29/10 0001
0040
01/12/11F
14
4 x 8 0 0.00 0.00
0 NA
12/29/10 0001
0041
01/26/1128
4 x 8 0 0.00 0.00
0 NA
12/29/10 0001
0042
01/26/11
28
4 x 8 0 0.00 0.00
0 NA
Remarks:
Technician(s): Hootman, D. RECEIReviewed bv:
Tested by: Cook, B. VED j—; -ea
JAN i 1011 Timothy G. Beckerle, P.E.
DEVELOPMENT S CTR Branch Manager
CRY OF EDMONDS
Notes:
Information in this report applies only to the actual samples tested and shall not be reproduced without the approval of Mayes Testing Engineers, Inc.
See ASTM C39, for full description of the Type of Fracture.
All testing performed in accordance with applicable ASTM's except C-31, 10.1.2, C-780, A MTE 1050-1C, Rev 4, 08/22/07
6.6.1.3, C-1019, 9.6 - "recording field temperature"
MAYESTESTING ENGINEERS, INC
CONCRETE LABORATORY TEST REPORT
Project Name:
212th Apartments
Site Address:
7219 213th Place SW
Supplier:
Edmonds, WA
Client:
EPIC Asset Management
Engineer:
Liu & Associates
Contractor:
Ram Jack Northwest, LLC
Air Temperature: 36°F
Weather:
Snow
Product:
Concrete
Supplier:
Concrete Nor'West
Batch Plant Location:
when applicable)
Ticket Number :
120814
MixDesign ID:
0360040
Project No:
Issued on:
Sample Set ID
Permit # (s):
FIELD DATA
ASTM C31 and C172
Mix Proportions:
Sample Temper Initial Storage Temp. Entrained Air
(ASTM C1064) 11 (ASTM C31) (ASTM C231)
78°F
VNIV
Slump (ASTM C143) Sample(s) Recd: Required Strength: (Pc)
5.5" 12/30/10 3000 psi @ 28 days
Placement Location and Notes:
Footings. No batchweights provided.
Lynnwood
20225 Cedar Valley Road
Suite 110
Lynnwood WA 98036
ph 425.742.9360
fax 425.745.1737
L10517
01/13/11
270513
Remarks:
Technician(s): Hootman, D.
Tested by: Cook, B.
Reviewed by:
Timothy G. Beckerle, P.E.
Branch Manager
Notes:
Information in this report applies only to the actual samples tested and shall not be reproduced without the approval of Mayes Testing Engineers, Inc.
See ASTM C39, for full description of the Type of Fracture.
All testing performed in accordance with applicable ASTM's except C-31, 10.1.2, C-780, A MTE 1050-1 C, Rev 4, 08/22/07
6.6.1.3, C-1019, 9.6 - "recording field temperature"
COMPRESSION TEST RESULTS
(ASTM C31, C39, C617, C1231, C780, C109,
C1019 or AASHTO T22
when applicable)
Date Made Sample #
Lab #
Date Tested Age Size (in)
Load (lbs) Dia (in)
Area Strength (psi) Type of Fracture
_12/29/10 0001
0039
01/05/11 0 4 x 8
57860 4.01
12.63 4580 ape 4
12/29/10
F 0040 1
F 01/12/11 14 -4—x- 8
6-6 -3 0-07 F 4.00
12.571 5280T e 3 t
12/29/10 0001
0041
01/26/1128 4 x 8
0 0.00
0.00 0 NA
12/29/10 0001
0042
01/26/11 28 4 x 8
0 0.00
0.00 0 NA
Remarks:
Technician(s): Hootman, D.
Tested by: Cook, B.
Reviewed by:
Timothy G. Beckerle, P.E.
Branch Manager
Notes:
Information in this report applies only to the actual samples tested and shall not be reproduced without the approval of Mayes Testing Engineers, Inc.
See ASTM C39, for full description of the Type of Fracture.
All testing performed in accordance with applicable ASTM's except C-31, 10.1.2, C-780, A MTE 1050-1 C, Rev 4, 08/22/07
6.6.1.3, C-1019, 9.6 - "recording field temperature"
Lynn
oo
MAYESTESTING ENGINEERS, INC 2 225 W dart/ alley Road
Suite 110
c, "^ Lynnwood WA 98036
ph 425.742.9360
CONCRETE LABORATORY TEST REPORT fax 425.745.1737
Project Name:
212th Apartments
Project No: L10517
Site Address:
7219 213th Place SW
Issued on: 01/11/11
Edmonds, WA
Sample Set ID: 270559
Client:
EPIC Asset Management
Permit (s):
:s #
Engineer:
Liu & Associates
Contractor:
Ram Jack Northwest, LLC
Remarks:
Technician(s): Egger, M.
Tested by: Revilla, Z.
Reviewed by:
Timothy G. Beckerle, P.E.
Branch Manager
Notes:
Information in this report applies only to the actual samples tested and shall not be reproduced without the approval of Mayes Testing Engineers, Inc.
See ASTM C39, for full description of the Type of Fracture.
All testing performed in accordance with applicable ASTM's except C-31, 10.1.2, C-780, A MTE 1050-1 C, Rev 4, 08/22/07
6.6.1.3, C-1019, 9.6 - "recording field temperature"
MAYESTESTING ENGINEERS, INC
CONCRETE LABORATORY TEST REPORT
Project Name:
212th Apartments
Project No:
Site Address:
7219 213th Place SW
Issued on:
Batch Plant Location:
Edmonds, WA
Sample Set ID
Client:
EPIC Asset Management
Permit # (s):
Engineer:
Liu & Associates
0.00
Contractor:
Ram Jack Northwest, LLC
0233
Air Temperature: 48°F
Weather:
Drizzle
Product:
Concrete
Supplier:
Concrete Nor'West
Batch Plant Location:
0.00
Ticket Number:
120317
MixDesign ID:
360040
FIELD DATA
ASTM C31 and C172
Design Mix Proportions:
Sample Temp. Initial Storage Temp. Entrained Air
(ASTM C1064) 11 (ASTM C31) (ASTM C231)
66°F
NR
Slump (ASTM C143) Sample(s) Rec'd: Required Strength: (fc)
4" 01/08/11 2100 psi @ 3 days
Placement Location and Notes: 2500 psi @ 28 days
Push pier pad footing between units 105 and 103. Batch weights not available onsite.
Lynnwood
20225 Cedar Valley Road
Suite 110
Lynnwood WA 98036
ph 425.742.9360
fax 425.745.1737
L10517
01/11/11
270559
Date Made Sample #
COMPRESSION TEST RESULTS
(ASTM C31, C39, C617, C1231, C780, C109, C1019 or AASHTO T22 when applicable)
Lab # Date Tested Age Size (in) Load (Ibs) Dia (in) Area Strength (psi) Type of Fracture
01/07/11 0002
0238
01/07/11
F01
4 x 8 0F 0.00
0.00
0 NA
01/07/11 0002
0239
01/07/117F
0
4 x 8 0 0.00
0.00
0 NA
01/07/11 0002
0233
01/10/11
4 x 8 42250 4.00
12.57
3360 T e 3
01/07/11 0002
0234
01/14/11
�
4 x 8 0 0.00
0.00
0 NA
01/07/11 0002
0235
02/04/11
28
4 x 8 0 0.00
0.00
0 NA
01/07/11 0002
0236
02/04/11
28
4 x 8 0 0.00
0.00
0 NA
01/07/11 0002
0237
02/04/11
28
4 x 8 0 0.00
0.00
0 NA
Notes:
Information in this report applies only to the actual samples tested and shall not be reproduced without the approval of Mayes Testing Engineers, Inc.
See ASTM C39, for full description of the Type of Fracture.
All testing performed in accordance with applicable ASTM's except C-31, 10.1.2, C-780, A MTE 1050-1 C, Rev 4, 08/22/07
6.6.1.3, C-1019, 9.6 - "recording field temperature"
El
MAYESTESTING ENGINEERS, INC
CONCRETE LABORATORY TEST REPORT
Project Name:
212th Apartments
Project No:
Site Address:
7219 213th Place SW
Issued on:
Batch Plant Location:
Edmonds, WA
Sample Set ID
Client:
EPIC Asset Management
Permit # (s):
Engineer:
Liu Associates
Area
Contractor:
Ram Jack Northwest, LLC
0039
Air Temperature: 36°F
Weather:
Snow
Product:
Concrete
Supplier:
Concrete Nor'West
Batch Plant Location:
C1019 or AASHTO T22
Ticket Number:
120814
MixDesign ID:
0360040
FIELD DATA
ASTM C31 and C172
Mix Proportions:
Sample Temp. Initial Storage Temp. Entrained Air
(ASTM C1064) (ASTM C31) (ASTM C231)
f3d9
NR
Slump (ASTM C143) Sample(s) Recd: Required Strength: (fc)
5.5" 12/30/10 3000 psi @ 28 days
Placement Location and Notes:
Footings. No batchweights provided.
Lynnwood
20225 Cedar Valley Road
Suite 110
Lynnwood WA 98036
ph 425.742.9360
fax 425.745.1737
L10517
01/06/11
270513
Remarks:
Technician(s): Hootman, D.
Tested by: Cook, B.
Reviewed bv:
Timothy G. Beckerle, P.E.
Branch Manager
Notes:
Information in this report applies only to the actual samples tested and shall not be reproduced without the approval of Mayes Testing Engineers, Inc.
See ASTM C39, for full description of the Type of Fracture.
All testing performed in accordance with applicable ASTM's except C-31, 10.1.2, C-780, A MTE 1050-1 C. Rev 4, 08/22/07
6.6.1.3, C-1019, 9.6 - "recording field temperature"
COMPRESSION TEST RESULTS
(ASTM C31, C39, C617, C1231, C780, C109,
C1019 or AASHTO T22
when applicable)
Date Made Sample #
Lab #
Date Tested Age Size (in)
Load (Ibs) Dia (in)
Area
Strength (psi) Type of Fracture
12/29/100001
0039
01/05/11 4 x 8
57860 4.01
12.63
4580 Type 4 `
12/29/10 0001
004001/12/11
14 4 x 8
0 0.00
0.00
0 NA
12/29/10 0001
0041
01/26/11 287
0.00 10
NA
12/29/10 0001
0042
01/26/11 28 ( 4 x 8
0 0.00
0.00
0 NA
Remarks:
Technician(s): Hootman, D.
Tested by: Cook, B.
Reviewed bv:
Timothy G. Beckerle, P.E.
Branch Manager
Notes:
Information in this report applies only to the actual samples tested and shall not be reproduced without the approval of Mayes Testing Engineers, Inc.
See ASTM C39, for full description of the Type of Fracture.
All testing performed in accordance with applicable ASTM's except C-31, 10.1.2, C-780, A MTE 1050-1 C. Rev 4, 08/22/07
6.6.1.3, C-1019, 9.6 - "recording field temperature"