Loading...
BLD20110770.pdfSTATUS: ISSUED 11/4/2011 Expiration Date: 11/4/2012 Parcel No: 00450700400612 RO EINAR SORVIK 605 12TH AVE N EDMONDS, WA 98020 (206)310-5623 NEW SFR. VALUATION: $290,893.60 v . IIII�lill CITY OF EDMONDS 121 5TH AVENUE NORTH - EDMONDS, WA 98020 PHONE: (425) 771-0220 - FAX: (425) 771-0221 Permit #: BLD20110770' EINAR SORVIK LEIF HELLEREN CONSTRUCTION C. 605 12TH AVE N LEIF HELLEREN E i FHC4D3807 EDMONDS, WA. 98020 PO BOX 1764 L (206) 310-5623 EDMONDS, WA 98020 �( 30 13 COMPLETED PERMIT TYPE: Residential PERMIT GROUP: 64 - Single Family Residence New GRADING: Y CYDS: 320 TYPE OF CONSTRUCTION: RETAINING WALL ROCKERY: N OCCUPANT GROUP: IRC OCCUPANT LOAD: FENCE: N ( 0 X 0 FT.) CODE: 09 OTHER: N -----OTHER DESC: ZONE: RS -8 NUMBER OF STORIES: 2 VESTED DATE: NUMBER OF DWELLING UNITS: 1 LOT It: BASEMENT: 0 1 ST FLOOR: 0 2ND FLOOR: 0 BASEMENT: 0 1 ST FLOOR: 1622 2ND FLOOR: 1010 3RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0 13RD FLOOR: 0 GARAGE: 526 DECK: 80 OTHER: 0 FRONT SETBACK SIDE SETBACK REAR SETBACK RE UIRED:7.5 PROPOSED: 12 1 REQUIRED: 7.5 PROPOSED: 17.5 1 REQUIRED: 7.5 PROPOSED: 20.6 HEIGHT ALLOWED:25 PROPOSED:24.61 I REQUIRED: 7.5 PROPOSED: 26 SETBACK NOTES: Setbacks: N, S, E, W Critical Area completed with S-2007-37 I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18:27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED.BY THE BUILDING OFFICIAL OR HIS/HER DEPUT ANDA L FEES ARE PAID. 17 1��TIZ �15r -Ll - /I Qn Signature Print Name Date Released By Date ATTENTION IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. UBC 109/ IBC 10/ IRCI 10. I , `" ' " - ONLINE APPLICANT = ASSESSOR STATUS: ISSUED BLD20110770 CONDITIONS • A complete set of asbuilts required prior to final permit sign off. • Lot line stakes must be in place at the time of foundation/setback inspection. • All new, extended, re -built or relocated electrical utility and/or service shall be placed underground. • Installer shall provide the manufacturer M's installation, operating instructions, and a whole house ventilation system operation description. A label shall be affixed to the whole house timer control that reads "Whole House Ventilation" (see operating instructions). • Hose Bibbs (exterior faucets) are required to have a permanently affixed anti -siphon device installed. • Obtain Electrical Permit from State Department of Labor & Industries. 425-290-1309 • Gas pipe test must be observed by City Building Inspector, affidavits shall not be accepted. • Final approval on a project or final occupancy approval must be granted by the Building Official prior to use or occupancy of the building or structure. Check the job card for all required City inspections including final project approval and final occupancy inspections. • Provide combustion air per IMC Chapter 7 for commercial and multi -family residential installations, and IRC Chapter 17 for one and two=family dwellings. • Any request for alternate design, modification, variance or other administrative deviation (hereinafter "variance") from adopted codes, ordinances or policies must be specifically requested in writing and be called out and identified. Processing fees for such request shall be established by Council and shall be paid upon submittal and are non-refundable. • Approval of any plat or plan containing provisions which do not comply with city code and for which a variance has not been specifically identified, requested and considered by the appropriate city official in accordance with the appropriate provision of city code or state law does not approve any items not to code specification. • Sound/Noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on weekdays and 10:00am and 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. • Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of whatever nature, arising directly or indirectly from the issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City """"s ability to enforce any ordinance provision. • 48 hours notice is required when requesting your FINAL Engineering Inspection. 425-771-0220, ext. 1326. • New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly visible from the street or road fronting the property. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be legible from the public way, at least 4 inches high with a %z inch min. stroke width on a contrasting background. • Call for locates of underground utilities prior to any excavation. • Maintain erosion & sedimentation control per city standards. • Maintain 10"""" separation between the sanitary side sewer and the water service line. • Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per City standards that is caused by or occurs during the permitted project. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT TIME LIMIT: SEE ECDC 19.00.005(A)(6) r BUILDING (425) 771-0220 EXT. 1333 1 ENGINEERING (425) 771-0220 EXT. 1326 1 FIRE (425) 775-7720 PUBLIC WORKS (425)771-0235 PRE-TREATMENT 425 672-5755 RECYCLING 425) 275-4801 When calling for an inspection please leave the following information: Permit Number, Job Site Address, Type of Inspection being requested, Contact Name and Phone Number, Date Pref reed, andowhether you prefer morning or afternoon. • E-Erosion Control/Mobilization • E-Storm Tightline • E-Storm Connect to Stub E-Footing Drain Connection E-Footing Drywell • E-Driveway Form & Slope Ver. • E-Engineering Final B-Preconstruction meeting • B-Setbacks • B-Footings • B-Foundation Wall B-Foundation Drainage B-Isolated Footings/Piers B-First Floor Framing B-Plumb Rough In • B-Gas Test/Pipe B-Mechanical Rough In B-Exterior Wall Sheathing • B-Roof Sheathing • B-Shear Nailing B-Height Verification • B-Framing B-Wall Insulation/Caulk B-Sheetrock Nail • B-Building Final \1 AA v 00 N d � r ` � s E� i s e •� 3 a L m ,oL d N &s as C ea a� O R o Z v CL v V > O O -a O p L C. C J m Q N A -0 N d C > -0 c E '00 O N N'_ CL \ C. O L, _d N C wtmC.± I r_ p r L' 40is z W a d d N. = L` Cc O ?. lum N LU O � 2 O C. --E -0.-_r w am wQ' M O CZ. Z d w H Z�NU Z - C w E O Z Q N r. r N C IL N d CV r r r O m co G E ea w w w a Y '> O V N V N O N d d �.i (n t ++ Q E 2 O O a N C t N � C T 16 W N Mr N r N L 'EOE N % tm U. C m r OC d j L Q 'o v d V V c 0 0 Q U) CD O y O O d O C V1 E N d d O V 0 C d C. Q 0 z 4 O 0 H O Q 00 0g6�pLy�jr Lu cJ CD C 5C P- c O 65 t=17n .t7 j� 111 ?I t. 0 ?,A K GEL AGGI<SS To FluIS+-( +oR�4DE P, S Pt , fiLT S -r o Rn, s -r- r. >=LE V. =sEp! ME L1T F ILTirR 3-77,0' SOCK HEIGH-r'; 'f.' 104,77-D 'D' - 106.00' DC -51'G1.1 Lir,! F 5 (051 Iluo, GRAD1t f,G% TorAL = �'ZS:. 166.44' ' St E 98111 Z.Z4-''a Sr. 5,,.,SW O71Q* ak ,WS. i`� Z5' GDkLOW�IS,N.- • `i&aZO 5E cog m F. ow G i37(o,d5l\ pG 1llAL 1-i T. = 1'3 +t.P�$:: TAX• oo� O% E�CST�,, 5"T'OIzAt . SEWE.1? "Ta C-X5'r, �t1 S LOT' C- IZA3?I U C--: 3 Z.O Gv. Y'as �xCAVPt�-L-b• Z:'O c.co.Yas. Ta tz � olJsa-r-E AS F ll..t., aACK- FI L^L i GE zucFcq� away I -A OTE sr'1"oK.ti1bg.-rr?r4T1oa v-ri i,Tlrs PIF -ft GI\/lL C11GIl�irE�(1Jlc pL 1,1s C-"oiZ 4 LOT'SF4o(LP PLA -r/ Z2Z3io-ZZ-4'"ks"f., zl n��c�t_L1t�O cou s-I-.� li.lc, � Ze3 07 E20S101,} Go1JT1=0L M F-ASUIZS-S T(`j .SF a 51S'Tr-_rte r- W1-rH GlT,C of t�DP1opJ�S s -r a k1 ap e t> -D a7TA 1 LS E.1. 1 - E-- 1. 73 F007IL16- -0R0•(r15 FIT Z-1 t ti=p Se LOQ,,/ A,LL-t.IS'+VR6EA SOILS WILL CSE Goti�Po$— A�c�=I�DEDt''EIZ M-"cAL- 6MP ET -A! L T- s.13 A P OVEU BY NNING • s o04 moo I.z 4,t=•�iL.s LOT' 1 of S� S-Z Gor.iiL!C: 5- Sf'ZE = Z-7-13 5- I M-FEr-VIOU5 . I V htt:�ER Roo.F - LAR 1Vtr �WF�1 _4C - LtsSS 0\/r-ZA V t FEB 2 7 2111-) � _ 3UILDING DEPARTMENT CITY OF F.DMONrX -C Lone ComerLP Flag ldbskfttdred Actual Froa Sides R=4E Wier,., Ejht Leight Calculation Worksheet Date I -ZG -/ L Permit Number Lo/t n2p p Address ��// d�.�f-L• �f Inspector (� Average Grade d .09 Max Height (25'+Ave_) 431&!? Actual Height (A+B+C) /.i, D o2 .TtIR-,. Elevation of transit above Datum (B) $,0Z - Datum , Elevation (A) 100 Utemp/building/forms/height worksheet =(C ) A:9- 0r—a7 OV E°Mo Inspection Comments BLD20110770 64 - Single Family Residence New Applied: 09/15/2011 Issued: 11/04/2011 Expires: 11/04/2012 enc. 1890 Address: 9811 224TH ST SW, EDMONDS INSPECTION DATE INSPECTOR ' ACTION.::. 1001 - E -Erosion Control/Mobilization 03/08/2012 SIBREL COM Comment: TESC adequate. 1001 - E -Erosion Control/Mobilization 03/29/2012 LAMBERTJ COR Comment: Silt fence separated from wire backing as I left -called leif and told him he needed to fix 1001 - E -Erosion Control/Mobilization 10/18/2012 ZULAUF COM Comment: approved amended soils being applied to entire yard 1001 - E -Erosion Control/Mobilization 10/30/2012 ZULAUF CMP Comment: ok to final- installing grass -to be completed today 1013 - E -Storm Tightline 03/26/2012 LAMBERTJ PAR Comment: Ok to backfill north, east, and south side. West side has reverse fall - left correction to fix west side to slope to detention. 1013 - E -Storm Tightline 03/29/2012 LAMBERTJ COR Comment: Correction notice given - see attached 1013 - E -Storm Tightline 03/29/2012 LAMBERTJ PAR Comment: Contractor to fix NW corner of tightline - told him he could backfill at his own risk, but we would water test the downspout. - From correction notice the tightline that was going under footing drain is sewer not storm. 1013 - E -Storm Tightline 06/25/2012 LAMBERTJ CMP Comment: ok 1014 - E -Storm Connect to Stub 03/29/2012 LAMBERTJ CMP Comment: Verified connection to stub - ok to backfill 1017 - E -Footing Drain Connection 03/29/2012 LAMBERTJ CMP Comment: Verified footing drain connection 1018 - E -Footing Drywell 03/29/2012 LAMBERTJ CMP Comment: Drywall had washed rock and landscape fabric-ok to backfill 1044 - E -Driveway Form & Slope Ver. 06/26/2012 ZULAUF CMP Comment: ok, at 14%. 1077 - E -Engineering Final 03/29/2012 LAMBERTJ COM Comment: Water test NW dowspout. 1077 - E -Engineering Final 10/30/2012 ZULAUF CMP Comment: ok to final 1101 - B-Preconstruction meeting 03/14/2012 LAWLER COM Comment: Canceled 1101 - B-Preconstruction meeting 06/06/2012 LAWLER CMP Comment: 10/30/2012 12:27:50 PM 121 5th Ave, Edmonds Washington - Phone: (425) 771-0220 Page 1 of 3 ;INSPECTION DATE INSPECTOR,., ACTION. 1106 - B -Setbacks 03/20/2012 LAWLER CMP Comment: 1108 - B -Footings 03/13/2012 LAWLER CMP Comment: 1110 - B -Foundation Wall 03/20/2012 LAWLER CMP Comment: 1112 - B -Foundation Drainage 03/26/2012 MILLERC CMP Comment: 1122 - B -First Floor Framing 04/04/2012 LAWLER CMP Comment: 1126 - B -Plumb Rough In 05/23/2012 LAWLER COM Comment: Seal foundation wall penetrations 1126 - B -Plumb Rough In 06/08/2012 LAWLER CMP Comment: 1128 - B -Gas Test/Pipe 05/23/2012 LAWLER COM Comment: CSST gas piping is required to be bonded with min. 6AWG wire 1128 - B -Gas Test/Pipe 06/06/2012 LAWLER CMP Comment: 1130 - B -Mechanical Rough In 05/22/2012 LAWLER COR Comment: 1.) seal sleaved plumbing penetrations through foundation walls 2.) gas piping to be bonded with number 6 AWG 3. Shield PEX piping within 6" of can lights 4.) DWV lost test upstairs 1130 - B -Mechanical Rough In 06/06/2012 LAWLER CMP Comment: 1132 - B -Exterior Wall Sheathing 05/04/2012 LAWLER CMP Comment: 1133 - B -Roof Sheathing 05/04/2012 LAWLER CMP Comment: 1136 - B -Shear Nailing 06/06/2012 LAWLER CMP Comment: 1140 - B -Height Verification 04/26/2012 LAWLER CMP Comment: 1142 - B -Framing 06/06/2012 LAWLER CMP Comment: 1144 - B -Wall Insulation/Caulk 06/26/2012 LAWLER CMP Comment: 1150 - B-Sheetrock Nail 07/03/2012 LAWLER CMP Comment: 10/30/2012 12:27:50 PM 121 5th Ave, Edmonds Washington - Phone: (425) 771-0220 Page 2 of 3 ;INSPECTION DATE INSPECTOR ACTION 1158 - B -Building Final 10/29/2012 LAWLER CMP Comment: 1158 - B -Building Final Comment: Pending engineering final 10/29/2012 LAWLER CMP 10/30/2012 12:27:50 PM 121 5th Ave, Edmonds Washington - Phone: (425) 771-0220 Page 3 of 3