BLD20110774 Plan Review Comments #2.pdf CE ITY OF DMONDS PLANREVIEWCOMMENTS PLANNINGDIVISION 425.771.0220 DATE: March 14, 2012 TO: Thomas Wahl brick@reliablefloorcoverings.com FROM: Kernen Lien, Associate Planner RE: Plan Check BLD20110774 th Deck Replacement/Addition @ 21708 98 Avenue W On behalf of the Planning Division, I have reviewed the above building permit application. During review of the subject submittal, it was found that the following information, corrections, or clarifications need to be addressed. Please respond to the following items, so that I can complete my review: Inconsistent Plans 1.: There are four sets of plans for the proposed deck (one prepared by Jarvis Design Group, another set that appears to be hand sketched, a third set with the structural calculations, and elevation views) and each set of plans is a little different. The plans must be consistent to ensure the deck is compliant with the zoning setbacks. Please submit consistent plans that clearly show the location of the existing deck and the locations of the proposed deck and roof lines. The deck must be consistent with the zoning setbacks as indicated in my October 3, 2011 comment letter and reiterated below in item 2. Setbacks 2.: The subject property is zoned RS-10 (Single Family Residential). Pursuant to Edmonds Community Development Code (ECDC) 16.20.030, the setbacks for RS-10 are: Zone Minimum Street Minimum Side Setback Minimum Rear SetbackSetback RS-10 25 feet 10 feet 20 feet The plot plan submitted with the application shows the new deck five feet from the northern property line, which is not compliant with the proscribed zoning setback of 10 feet for the RS-10 zone. From historical photos and Snohomish County Assessor information, it appears that the existing deck was originally constructed in the current location when the residence was constructed. This portion of the deck is considered nonconforming according to ECDC 17.40.020 and may be reconstructed to its current location. All new portions of the deck (including the roof) must comply with the proscribed zoning requirements in ECDC 16.20. The roof supports must be located at least 10 feet from the northern property boundary, but according to ECDC 16.20.040.B, the eaves may extend not more than 30 inches into the setback. Please revise the deck plans so the proposed deck and deck roof are compliant with the required setbacks for the RS-10 as proscribed by ECDC 16.20.030. The spiral staircase appears to be a later unpermitted addition. These stairs must be removed and replaced with new stairs that are compliant with the required setbacks. Feel free to contact me if you have any questions. Please make all submittals to a Development Services Permit Coordinator, Monday through Friday, 8:00 am 4:30 pm. If you have any questions, feel free to contact me at 425.771.0220 ext 1223.