BLD20120858.pdf111111111,
OF E1)M
CITY OF EDMONDS
:t
121 5TH AVENUE NORTH - EDMONDS, WA 98020
PHONE: (425) 771-0220 - FAX: (425) 771-0221
STATUS: ISSUED 09/26/2013 Permit #: BLD20120858
BUILDING'
Expiration Date: 09/26/2015 Project Address: 15500 75TH PL,W, EDMONDS
Parcel No: 00500900000103
GEORGE & GINGER OLSON JAMES THOMAS, ARCHITECT ROGER OLIN CONSTRUCTION
3528 102ND PL SE 2221 EVERETT AVE # 106 Po Box 3216
EVERETT, WA 98208 EVERETT, WA 98201 Everett, WA 98203
(425)337-5046 (425)259-0661 (425)337-7622
LICENSE #: ROGER00088CN EXP:02/28/2014
JOB DESCRIPTION
NEW TWO STORY RESIDENCE WITH TWO CAR GARAGE - MECHANICAL AND PLUMBING INCLUDED - ESLHA
VALUATION: $344,493.20 COMPLETED
PERMIT TYPE: Residential
PERMIT GROUP: 64 - Single Family Residence New
GRADING: Y CYDS: 364
TYPE OF CONSTRUCTION: VB
RETAINING WALL ROCKERY: N
OCCUPANT GROUP: R-3/U
OCCUPANT LOAD:
FENCE: N ( 0 X 0 FT.)
CODE: 09
OTHER: N------- OTHER DESC
ZONE: RS-20
NUMBER OF STORIES: 2
VESTED DATE:
NUMBER OF DWELLING UNITS: 1
EXISTING AREA
LOT #:
PROPOSEDAREA
BASEMENT: 0 1 ST FLOOR: 0 2ND FLOOR: 0
1BASEME7T70 I ST FLOOR: 1599 2ND FLOOR: 1339
3RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0
13RD FLOOR: 0 GARAGE: 707 DECK: 496 OTHER: 345
FRONT SIDE SETBACK REAR SETBACK
REQUIRED: E 25 PROPOSED: 25; 0* REQUIRED: N 10/35 PROPOSED: 17 RE UIRED: W 25 PROPOSED: 113/120+
HEIGHT ALLOWED:25 PROPOSED:25 REQUIRED: S 10/35 PROPOSED: 18
SETBACK NOTES: RS-20 setbacks - 10' minimum on sides, 35' min total, *0' setback for driveway/bridge and steps only, house is 25' per PLN20120047, rear -
deck 113', house 120+'
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO
PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S
COMPENSATION INSURANCE AND RCW 18:27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID.
/"' t�
ft�''.�A.��.7
Si ature Print game Date Released By Date f
ATTENTION
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF
OCCUPANCY HAS BEEN GRANTED. UBC109/ IBC110/IRCI10.
t� ' �
ONLINE APPLICANT ASSESSOR ` � OTHER I,9
STATUS: ISSUED BLD20120858
CONDITIONS
• REQUIRED SPECIAL INSPECTIONS FOR THIS PROJECT:
• 1) Grading/Soils
• 2) Auger cast piles
• 1. Development shall proceed in accordance with Nelson & Associates geotechnical reports of 7/15/11, 4/3/13 and 7/1/13."
• 2. Tree #320, as shown on the landscaping plan from Harmsen & Associates approved July 22, 2013, shall be retained and
protected until such time that an independent certified arborist selected by the City determines whether or not the tree is
hazardous. This indepenent review shall be paid for by the applicant. Tree #320 shall be protected in accordance with the
tree conservation notes on the approved landscaping plan. If the tree is found to be hazardous by the independent arborist, it
may be removed in accordance with the approved landscaping plan. If the tree is to be retained, the landscaping plan shall be
updated to note the retention of Tree #320 and, as applicable, the elimination of Vine Maple and Excelsa Cedar from the
replanting plan.
• Lot line stakes must be in place at the time of foundation/setback inspection.
• Installation, use and maintenance of equipment and components shall be per manufacturer's specifications, installation
instructions, and applicable state codes. Provide manufacture's installation instructions on site for Building Inspector.
• Approval of this foundation design is conditional subject to inspection of existing site soil conditions.
• Retaining Walls must be designed and constructed to resist the lateral pressure of the retained material.
• Provisions must be made for the control and drainage of surface water around buildings.
• Installer shall provide the manufacturer's installation, operating instructions, and a whole house ventilation system operation
description. A label shall be affixed to the whole house timer control that reads "Whole House Ventilation" (see operating
instructions).
• Maximum Height 25 feet. The agent/contractor shall set up the equipment; establish the datum point and the point of average
grade. Call for inspection to verify. These items must be consistent with the approved plan. If the proposed height of a
building (as shown on the plans) is within 12 inches of the maximum height permitted for the zone an elevation survey is
required.
• Special inspections have been called for on this project and are noted on the approved construction plans and building permit.
It is the owner and/or contractors responsibility to assure that reports are provided to the City on a weekly basis. Be advised --
if special inspection reports are not forthcoming, the Building Official may issue a "Stop Work" and no City inspections will
be provided until such time as the reporting agency has complied and reports are reviewed and approved by the City.
• Hose Bibbs (exterior faucets) are required to have a permanently affixed anti -siphon device installed.
• In addition to the required pressure/relief valve, an approved listed expansion tank shall be installed on all hot water tanks.
Per UPC 608.
• Type B or L vent connectors required on fuel -burning appliances passing through unheated spaces. Per IMC 803.2
• Obtain Electrical Permit from State Department of Labor & Industries. 425-290-1309
• Pursuant to UPC 605.2 a water service shutoff shall be installed on the water line as it enters the building.
• Gas pipe test must be observed by City Building Inspector, affidavits shall not be accepted.
• As required by Ordinance #3632 the geotechnical engineer of record shall monitor this site during construction for
compliance with the recommendations in the geotechnical report including: site excavation, shoring, soil support for
foundation including piles, soil bearing capacity, subdrainage installation, soil compactions, and other geotechnical aspects of
the construction. Specific recommendations contained in the approved geotechnical report must be implemented by the
owner. The geotechnical engineer shall make written, dated reports on the progress of the construction and submit the report
to the Building Official on a weekly basis until all site grading, drainage, foundation and associated ground work is complete.
Omissions or deviations from the approved geotechinical report and/or approved plans or specifications shall be highlighted
and immediately submitted in a seperate letter to the City for review. The City shall be advised in writing of work stoppages
of more than one week. In addition to the geotechnical monitoring, special inspections based on the provisions of IBC Section
1704 are required when specified on the approved plans. Other special inspections may also be required by the geotechnical
engineer, architect, or structural engineer of record (refer to approved plan set). At the completion of final site grading and all
permitted structures, a final geotechnical report, prepared by the geotechnical engineer shall be submitted to the Building
Official. This report shall contain a statement that, based upon his/her professional opinion, site observations, and testing
during the monitoring of the construction, the completed development substantially complies with the recommendations in the
geotechnical report and with all geotechnical related permit requirements. Any deviations or omissions in the report, plans, or
specifications that occured during construction shall be addressed separately. Occupancy, final approval, or release of the
bond for the project shall not be granted until the report has been reviewed and accepted by the Building Official.
• Final approval on a project or final occupancy approval must be granted by the Building Official prior to use or occupancy of
the building or structure. Check the job card for all required City inspections including final project approval and final
occupancy inspections.
• Provide combustion air per IMC Chapter 7 for commercial and multi -family residential installations, and IRC Chapter 17 for
one and two-family dwellings.
• Any request for alternate design, modification, variance or other administrative deviation (hereinafter "variance") from
adopted codes, ordinances or policies must be specifically requested in writing and be called out and identified. Processing
fees forisuch request shall be established by Council and shall be paid upon submittal and are non-refundable.
• Approval of any plat or plan containing provisions which do not comply with city code and for which a variance has not been
specifically identified, requested and considered by the appropriate city official in accordance with the appropriate provision
of city code or state law does not approve any items not to code specification.
• Pursuant to UPC 608 a pressure regulator valve (PRV) shall be installed near the water shutoff.
• Sound/Noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits
of ECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on weekdays and 10:00am and 6:00pm on Saturdays,
excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must.
comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120.
• Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend.and hold
harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of
whatever nature, arising directly or indirectly from the issuance for this permit. Issuance of this permit shall not be deemed to
modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any
ordinance provision.
• New and existing buildings shall have approved address numbers, building numbers or approved building identification
placed in a position that is plainly visible from the street or road fronting the property. Address numbers shall be Arabic
numerals or alphabet letters. Numbers shall be legible from the public way, at least 4 inches high with a %: inch min. stroke
width on a contrasting background.
• Maintain 10"""" separation between the sanitary side sewer and the water service line.
INSPECTIONS
THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE
PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION.
PERMIT TIME LIMIT: SEE ECDC 19.00.005(A)(6)
BUILDING (425) 771-0220 EXT. 1333 1 ENGINEERING (425) 771-0220 EXT. 1326 1 FIRE (425) 775-7720
PUBLIC WORKS (425) 771-0235 PRE-TREATMENT (425) 672-5755 RECYCLING (425) 275-4801
When calling for an inspection please leave the following information: Permit Number, Job Site Address, Type of Inspection
being requested, Contact Name and Phone Number, Date Prefereed, and whether you prefer morning or afternoon.
• B-Preconstruction meeting
• B-Special Insp Auger Cast Piles
• B-Setbacks
• B-Footings
• B-Foundation Wall
• B-Foundation Drainage
• B-Isolated Footings/Piers
• B-Underfloor/First Floor Framing
• B-Plumb Rough In
• B-Gas Test/Pipe
• B-Mechanical Rough In
• B-Exterior Wall Sheathing
• B-Roof Sheathing
• B-Window Flashing
• B-Height Verification
• B-Interior Shear Walls
• B-Framing
• B-Shower Pan Test
• B-Insulation/Energy
• B-Sheetrock Nail
• B-Building Final
• P-Planning Final
O�
O
V,
i
�Qr. 1 89Q
City of Edmonds
DEVELOPMENT SERVICES
ESLHA BUILDING PERMIT
APPLICATION FORM F
121 5t' Avenue N, Edmonds. WA 98020
Phone 425.771.0220 $ Fax 425.771.0221
PLEASE REFER TO THE RESIDENTIAL BUILDING CHECKLIST FOR SUBMITTAL REQUIREME.Nf'S
PROJECT ADDRESS (Street, Suite #, City State, Zip):
Parcel #:
Subdivision/Lot #:
Project VtaIuation: S
APPLICANT-
✓t fi% �' jjyf� rh o
Phone:
¢2f'•�Cq-�i6!
Fax:
�EAla f
Address (Street, City, State, Zip):
E-Mail Address:
nr-i
PROPERTY OWNER:
C.6i- pp"5; Ely,9l� o&ZA1
Ph ne:
f ar- OJT- 5VIL4
Fax:
Address
(� City,�0 f L 1p)E:6 L�l/P..�� � • �� ���'
E-Mail Address:
LENDING AGENCY:
Phone:
Fax:
Address (Street, City, State, Zip):
E-Mail Address:
CONTRACTOR:* Ro6lt V"IV CetVJ7`V!>C.i%C7t1V
Phone: - 3S'�' T/ •r2
"-
ti1A ii�I�A�1G"
Address (Street City, State, Zip):
( � try, P)�
xPi �,;:�,-�,. _
License #/E Date:
"Contractor must have a valid Ciry of Edmonds business license prior to doing wnr* in the
City Business License #/Exp. Batt':§`
City. Convect the City Clerk's ice at 425, 775.2525
DETAIL SCOPE OF WORK: N' 2- T Rn-
/
r
t&C iL0L
PROPOSED NEW SQUARE FOOTAGE FOR THIS PROJECT:
Basement: AMA s . ft.
Select Basement Type: 0 Finished:. 0 Unfinisbtgd ...
I" Floor: MA4,VS'9 sq. ft.
Garage/Carport: •T s
F Floor: POP- 1,337 s . ft.
Deck/Patio:
Retaining Wall: Yes 2rNo
er: VS'S.. O 6M aft ..'
S +"tfi►j� tvMK-a
Imo' 23
1 declare under penalty of perjury laws" the information I have provided on this fornr/appllcar�fotr►'aiu�, cotrt puui
complete, and that I am the property owner or duly authorized agent of the property owner to subJr ft s pe ;;;j�.
the City of Edmonds.
PR'Gd 6�y'"
Print Name: y4M ET A• %ff D S
0 Owner KAgent/other (specify):
Signature:
Date: a �A'��-
LABuilding New Folder 201000NE & x-ferred to L-Building-Ntw drivelESLHAApplication.doe
Updated: 912010
RECEIVED
OCT 0 7 2014
DEVELOPMENT SERVICES
COUNTER
NELSON GEOTECHNICAL
NGAGEOTECHNBCAL ENGINEERS & GEOLOGISTS
Main 017ico
\\ oodinrillc, \VA 9072
(425) 4k6-1669 I AX (4?5) 4�l-7i)(i
September 19, 2014
Mr. George Olson
c/o Roger Olin
PO Box 3216
Everett, Washington. 98213
Construction Monitoring Summary Letter
Olson Residence
Edmonds, Washington
NGA File No. 8342C 13
Dear Mr. Olson,
I:ngincxrin,-Ucolon; Branch.
5526111dusury Lane.'72
Gas; \\ crtalchec, \\':\ 9; s02
(509) 665-7/696 FAX (509) 665-7692
We were requested by your builder Roger Olin to prepare this summary letter for your residence project
located at 15500 — 75t' Place West in Edmonds, Washington.
Introduction
We were retained to provide part-time monitoring and consultation services during the earthwork phase of
construction per the Special Inspections and Testing Agreement required by the City of Edmonds (Permit
No. BLD20120858). Our earthwork monitoring activities at the project took place on a part-time basis
from October 17, 2013 through June 24, 2014 and included observing pier installation, footing drain
installation, and erosion control measures. Our observations and conclusions were documented in Field
Reports 1 through 23, all of which have been submitted to you. We previously prepared a geotechnical
engineering report for the property titled "Revised Geotechnical Engineering Report — Olson Residence —
15500-75t' Place West — Edmonds, Washington," dated July 15, 2011. We also prepared a plan review
letter for the project dated April 3, 2013.
Construction Monitoring Summary Letter NGA File No. 8342C13
Olson Residence September 19, 2014
Edmonds, Washington Page 2
Site Observations
We monitored drilled pier installation activities on October 28, 2013 through October 30, 2013 as
documented in Field Reports #3 through 6. We observed the drilling of 23, 22-inch diameter holes
advanced to depths of approximately 26 feet below the ground surface throughout the entire residence
foundation area. The holes were drilled with a large drilling auger and the soil exposed in the cuttings
mostly consisted of light brown, fine to medium sand grading to dark gray clay. Minor caving was
encountered in some of the holes and some of the holes required casing to remain open. After rebar cages
were lowered into the drilled holes, the holes were backfilled with structural concrete to planned
elevations.
We also observed the installation of 18, 2-inch pin piles for the planned deck posts on the western side of
the residence. The pin piles consisted of Schedule 80 galvanized steel piles and were driven between 13
to 19 feet below the ground surface. The pin piles were driven with a 140-1b hammer to a refusal criteria
of less than one inch of movement during 60 seconds of continuous driving.
We observed the stormwater overflow pipe that was installed down the steep slope on the northern side of
the property. The pipe consisted of an 8-inch diameter HDPE pipe and was anchored to the slope using a
clamp and cable system. The clamps were secured to the slope using 5-foot long, 3-inch diameter
galvanized bars.
We observed some of the backfill for the on -site utilities including storm and water lines and detention
pipes and manholes. Some of the material consisted of on -site soil and other areas were backfilled with
crushed rock. The areas where on -site material was used was generally over -optimum moisture when it
was placed and was pumping. We tested the backfill with a nuclear densometer and the test results did
not meet 95% compaction of ASTM D1557. We recommended to the contractor that the unsuitable soils
be removed and replaced with drier soil, or re-evaluated at a later time. We returned to the site roughly
two months later and retested the failed areas. Some of the areas met compaction, but an area on the
northem side of the house was -still over optimum. We discussed the slight potential for future settlement
of this material. We were informed by Roger Olin that no structures were planned for this area and that
they were aware of the risks.
NELSON GEOTECHNICAL ASSOCIATES, INC.
Construction Monitoring Summary Letter NGA File No. 8342C13
Olson Residence September 19, 2014
Edmonds, Washington Page 3
We also observed that footing drains were installed along the western, uphill side of the residence. The
drains consisted of 4-inch perforated pipes. We recommended that the drains be surrounded with washed
rock and covered with filter fabric. The contractor agreed. The contractor informed us that the roof
downspouts would not be connected to the footing drains, as we recommended in our geotechnical report.
We visited the site on September 10, 2014 to observe the final landscaping preparation. We observed that
the site had been graded and that some vegetation planted throughout the backyard and side yard. We did
observe areas of exposed soils. We recommend that all remaining exposed areas be covered with
landscaping plants and/or hydroseed to reduce the potential for soil erosion during the wet season. These
areas should be closely monitored and repaired as needed. It is our opinion that the erosion control
methods incorporated into the landscape design appear to be' adequate and should help prevent surface
water from reaching the steep slope once these systems are fully established. We also observed the steep
slope and did not observe significant signs of instability. We should note; however, that the slope below
the residence did experience a small landslide two to three years ago. Although the area that was affected
by the slide is relatively far away from the new residence and should not have an impact on the recent
improvements, during extreme weather, this area may experience additional movement. We recommend
that this area be monitored from time to time, especially during heavy rainfall. We should be contacted
should signs of renewed earth movement be observed.
Conclusion
Based on our part-time observations, it is our opinion that the geotechnical earthwork activities at this
site, including residential foundation subgrade, pier installation, subsurface drainage, and erosion control
methods were completed in general accordance with our recommendations, contract plans, and
specifications. The steep slope should be closely monitored for any signs of distress. If any distress is
observed, we should be contacted immediately to evaluate the conditions and provide recommendations
for slope repairs. Also, long-term maintenance of the drains and landscaped areas is important to prevent
water from flowing over the slope and creating instability concerns. All other recommendations and
precautions presented in our report and memo regarding maintaining slope stability should be strictly
followed. We recommend that our report and memo along with this letter be passed on to future home
owners if the house is sold.
NELSON GEOTECHNICAL ASSOCIATES, INC.
Construction Monitoring Summary Letter
Olson Residence
Edmonds, Washington
NGA File No. 8342C13
September 19, 2014
Page 4
We appreciate the opportunity to be of service to you on this project. We consider our services for this
project to be complete, unless you specifically contact us for additional work. If you have any questions
regarding this letter or require further information, please call.
Sincerely,
NELSON GEOTECHNICAL ASSOCIATES, INC.
Bala Dodoye-Alali,
Project Geologist
Exp. July 28, 2015
Khaled M. Shawish, PE
Principal
BD:KMS:cja
NELSON GEOTECHNICAL ASSOCIATES, INC.
CITY OF EDMONDS
121 5th AVENUE NORTH • EDMONDS, WA 98020 • (425) 771-0220 • fax (425) 771-0221
www.edmondswa.gov
DEVELOPMENT SERVICES DEPARTMENT
.. N
October 14, 2014
George & Virginia Olson
3528 102n, PL SE
Everett, WA 98208
RE: Release of ESLHA Site Restoration Bond #359 5619 873
Owner: George and Virginia Olson
Project Address: 15500 75t' PL W
George and Virginia Olson:
DAVE EARLING
MAYOR
The City of Edmonds hereby authorizes the full release of the ESLHA Site Restoration Bond #3595619
873. All interested City departments have approved the release of this bond. I have attached a copy of
the Bond. Please take. this letter to BECU for release per conversation with Ayla Gillum on October 14,
2014.
Sincerely,
Zt&c,-
Linda Thornquist
Senior Permit Coordinator
City of Edmonds 425-771=0220
Cc: File
• Incorporated August 11, 1890 •
Sister City - Hekinan, Japan
Q.
co
ro•
v
D
N!
N
C
CD
a
0
0
O
A
rr
y
� (D
O
r•
f�
(D C
MAD
c Q
�
D.
..
a
.•�
CD
0
•'�
o.
eD
r.
�
mw<j
rA
mmgoC-n
o� O o
k
.a
mom o
rA
N. m
.
z go
r•h
r•
n
D
D
omM
00 O vCD
CD
r
r.
. O O
Z Z
M'
!•t
r.
r.
D
04-
Cl)
i
o
e
°--%�
46pill
N
C
�C
!•
to
r.
m
r
O
m
m
�
°
0w
CD::
Z
z z
°y
�•
•G O
O
0
c
Dr
�
o• co
w o r-
D
Co-
CDo
b
o•
-'
N
rr
D
r..
OC)
Lrl
�•
C
.
O OD
C•
CC)
C:
O
�
C �Q
p
O•
D
p„
CD
O
s
11
OTTO ROSENAU & ASSOCIATES. INC.. RECEIVED
Geotechnical Engineering, Construction Inspection & Materials Testing DES 10 2013
DEVELOPMENT SERVICES
COUNTER
GROUT REPORT
Job Number: 13-0684 Report Number:
Project: Olson Residence - Edmonds Client:
Address: 15500 75`" Place West, Edmonds Address:
Date: 10/29/13 Inspector.
125916 Permit Number: BLD 2012-0858
George & Ginger Olson
15500 75u' Place W, Edmonds
Gordy Moe
Description / Location: Augered and cast in -place pile numbers 9, 10, 11, 21, and 22. Reinforcing steel as per the approved plans
and specifications for size, grade, and spacing.
Resteel grade:
60
Manufacturer: Cascade Mills
Placement Data
Batch Weights
Supplier:
Cadman
Cement (Ibs%type.): 846# 1/II
Water (Ibs./gal): 450#
Mix Number:
3GO0149
Fine Agg.,(Ibs.): 2357#
Admixtures (specify)
Total Yards Placed: 18 .
Coarse Agg. (size/lbs.):
42 oz. Delvo Stabilizer
Specified Strength
(psi): 3000 @ 28
days
Coarse Agg. (size/Ibs.):
Sampling and Casting of Samples
Additional Tests/Data Obtained
ASTM C 31, C 109
ASTM C939
Time Cubic
Grout
Ambient Truck Ticket
Size:
Set #
Cast Yards Flow
Temp
Temp No. No.
Cast Samples:
1-5
9 n/a
64°
47' 310 114479
Cast Samples:
6-10
15 n/a
62°
54° 285 114679
Weather:
Fair, Mid 40°F-Mid 50°F
Date Samples Picked Up: 10/30/13
Comments
Contractor: McDowell N.W.
Other Test Methods / Standards Used:
REINFORCING / PLACEMENT: Conforms X Does Not Conform
TEST RESULTS .
Specimen
Test Field
Age
Size Area
Max Load
Strength Type of Fracture
Number
Date Cure (Days)
(in.) (Sq.In•) Weight
Lbs.
f P-Si (other than cone)
1
11 /1 /13
3
2x4 3.14 .95#
9330
2970
2
11/5/13
7
2x4 3.14 .90#
13,870
4460
3
11/26/13
28
2x4 .3.11 .93#
15,880
5110
4
11/26/13
28
2x4 3.11 .90#
13,860
4460
5
11/26/13
28
2x4 3.11 .92#
18,690
6010
6
11/1/13
3
2x4 3.14 .98#
11,100
3540
7
11/5/13
7
2x4 3.11 .90#
12,840
4130
8
11/26/13
28
2x4 3.11 .91#
17,800
5720
9
11/26/13
28
2x4 3.11 .91#
17,520.
5630
10
11/26/13
28
2x4 r 3.11 .91#
18,810
6050
Tested in general accordance to: ASTM C39 x ASTM C78 ASTM C109 ASTM C617 _ ASTM C1231
Note: Type of fracture does not apply when testing in conformance to ASTM C1231
Copies to:
X Client Contractor
X Architect X Building Dept. Technical Responsibility:
Engineer. Anthony Coy:VeDr(
ssional En ' eer
This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau & Associates, Induction of this report,
except in full, without written permission from our firm is strictly prohibited.
Page 1 of 1
6747 M.L. King VVay S., Seattle, Washington 98118 - Phone (206) 725-4600 or 1-888-OTTO4-US - Fax (206) 723-2221
Form No.: ADMIN-71-04 (Rev 05113)
RECEIVED
OTTO ROSENQU & ASSOCIATES, INC. DEC .10 2013
Geotechnical Engineering, Construction Inspection & Materials Testing DIEVELOPMENT SERVICE:
(;UUNILH
GROUT REPORT
Job Number. 13-0684 "Report Number: 125917 Permit Number: BLD 2012-0858
Project: Olson Residence — Edmonds
Client: George & Ginger Olson
Address: 15500 75'" Place West, Edmonds
Address: 15500 75"' Place W, Edmonds
Date: 10/30/13
Inspector. Gordy Moe
Description / Location: Augered and cast in -place pile numbers 9, 10, 11, 21, and 22. Reinforcing steel as per the approved plans
and specifications for size, grade, and spacing.
Resteel grade: 60 Manufacturer.
Cascade Mills
Placement Data
Batch Weights
Supplier: Cadman
Cement (Ibs/type.): 846# 1111 Water (Ibs./gal): 450#
Mix Number: 3G00149
Fine Agg. (Ibs.): 2357#
Admixtures (specify)
Total Yards Placed: 18
Coarse Agg. (size/Ibs.): 42
oz. Delvo Stabilizer
Specified Strength (psi): 3000 @ 28 days
Coarse Agg. (size/Ibs.):
Sampling and Casting of Samples
Additional Tests/Data Obtained
ASTM C 31, C 109
ASTM C939
Time Cubic Grout Ambient Truck Ticket
Size: Set #
Cast Yards Flow Temp
Temp No. No.
Cast Samples: 1-5
9 n/a 64°
51 ° 272 114805
Cast Samples: 6-10
18 n/a 63'
54' 274 114913
Weather:
Date Samples Picked Up: 10/31/13
Comments
Contractor: McDowell N.W.
Other Test Methods / Standards Used:
REINFORCING / PLACEMENT: Conforms
X Does Not Conform
TEST RESULTS
Specimen Test Field Age
Size Area Max Load
Strength Type of Fracture
Number Date Cure (Days)
(In.) (Sg•In•) Weight Lbs.
fwa (other than cone)
1 11/1/13 2
2x4 3.14 .89# 7170
2280
2 11/6/13 7
2x4 3.11 87# 12,650
4070
3 11/27/13 28
2x4 .3.08 .88# 20,110
6530
4 11/27/13 28
2x4 3.08 .89# 19,49b
6330
5 11/27/13 28
2x4 3.08 .87# 19,980
6490
6 11/1/13 2
2x4 3.14 .93# 6980.
2220
7 11/6/13 7
2x4 3.11 .86# 12,580
4050
8 11/27/1'3 28
2x4 3.08 .87#. 18,340
5960
9 11/27/13 28
2x4 3.08 .91# 18,140
5890
10 11/27/13 28
2x4 r 3.08 .90# 17,740
5760
Tested in general accordance to: ASTM C39 x ASTM C78 ASTM C109 ASTM C617 ASTM C1231
Note: Type of fracture does not apply when testing in conformance to ASTM C1231
Copies to:
X Client Contractor
X Architect X Building Dept Technical Responsibility:
Engineer Anthony Coyne, Pr fessional En eer
This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau & Associate I Reproduction of this report, .
except in full, without written permission from bur firm is strictly prohibited.
Page 1 of 1
6747 M.L. King Way S., Seattle, Washington 98118 - Phone (206) 7254600 or 1-888-OTT04-US - Fax (206) 723-2221
Form No.: ADMIN-71-04 (Rev 05113)
r
RECEIVED
OTTO ROSENAU & ASSOCIATES, INC. opC 10 2013
Geotechnical Engineering, Construction Inspection & Materials Testing Q Q-0AAChIT eGQInrrES
COUNTER
GROUT REPORT.
Job Number. 13-0684 Report Number. 125918 Permit Number: BLD 2012-0858
Project: Olson Residence - Edmonds Client: George & Ginger Olson
Address: 15500 75"' Place West, Edmonds Address: 15500 75"' Place W, Edmonds
Date: 10/31/13 Inspector. Gordy Moe
Description / Location: Augered and cast in -place pile numbers 17, 18, 19, 22, and 23. Reinforcing steel as per the approved plans
and specifications for size, grade, and spacing.
Resteel grade: 60 Manufacturer: Cascade Mills
Placement Data Batch Weights
Supplier: Cadman Cement (lbs/type.): 846# 1/11 Water.(Ibs./gal): 450#
Mix Number: 3GO0149 Fine Agg. (lbs.y 2357# Admixtures (specify)
Total Yards Placed: 15 Coarse Agg. (sizeAbs.): 42 oz. Delvo Stabilizer
Specified Strength (psi): 3000 @ 28 Coarse Agg. (sizeAbs.):
days
Sampling and Casting of Samples Additional Tests/Data Obtained
ASTM C 31, C 109 ASTM C939
Time Cubic Grout Ambient Truck Ticket
Size: Set # Cast Yards Flow Temp Temp No. No.
Cast Samples: 1-5 9 n/a 65° 52' 312 115061
Cast Samples: 6-10 14 n/a 620 54° 284 115239
Weather: Overcast, Low to Mid 50°F
Date Samples Picked Up: 11/4/13
Comments
Contractor: McDowell N.W.
Other Test Methods / Standards Used:
REINFORCING / PLACEMENT: Conforms X Does Not Conform
TEST RESULTS
Specimen
Test
Age
Size
Area
Max Load
Number
Date
(Days)
u
(So•In.)
Weight
Its.)
1
11/4/13
4
2.00x4.00
3.11
.90#
9630
2
11 /7/13
7
2.00x4.00
3.11
.91 #
11,580
4
11/28/13
28
1.98x3.91
3.07
.93#
20,680
5
11/28/13
28
2.02x3.92
3.20
.94#
'20,620
6
11/28/13
28
1.99x4.21
3.11
1.01#
20,290
6
11/4/13
4
2.00x4.00
3.11
.91 #
9420
7
1IM13
7
2.00x4.00
3.11
.89#
8480
8
11/28/13
28
1.98x3.98
3.07
.93#
17,890
9
11/28/13
28
2.00x3.97
-3.14
.94#
16,730
10
11/28/13
28
2.00x3.93
3.14
.92#
17,490
Tested in general accordance to:
ASTM C39
x ASTM C78
ASTM C109
Note: Type of fracture does not apply when testing in conformance. to ASTM C1231
Strength Type of Fracture
si (other than cone)
3100
4610
6740
6440-Q
6520
3030
2730
5830
5330
5570
ASTM C617
ASTM C1231 _
Copies to:
X Client Contractor
X Architect X Building Dept. Technical Responsibility:
Engineer Anthony?/,Innc.
Professio I Engineer
This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau & Associa Reproduction of this report,
except in full, without written permission from our firm is strictly prohibited.
Page 1 of 1
6747 M.L. King Way S., Seattle, Washington 98118 - Phone (206) 725-4600 or 1-888-0TTO-4-US - Fax (206) 723-2221
Form No.: ADMIN-71-04 (Rev 05113)
I
ECEIVED
OTTO ROSE AU ASSOCIATES, INC � NOV
Geotechnical Engineering, Construction Inspection & Materials Testing 1 �D13
Vr-LU N7 SERli
COUNTEt� ICES
F` GROUT REPORT
Job Number: 13-0684 Report Number: 125915 Permit Number: BLD2012-0858
Project: Olson Residence = Edmonds Client: George & Ginger Olson
Address: 15500 75"' Place West, Edmonds Address: 15500 75`" Place W, Edmonds
Date: October 28, 2013 Inspector. Gordon Moe
Description / Location: Inspected augered and cast in place pile #'s: 1, 2, 3, 12, 13, 15 and 16. Reinforcing steel as per the approved
plans and specifications for size, grade and spacing.
Resteel grade: 60 Manufacturer: Cascade Mills
Placement Data
Batch Weights
Supplier: Cadman
Cement (Ibs/type.): 846# 1/11
Water (Ibs./gal): 450#
Mix Number: 3GO0149
Fine Agg. (lbs.): 2357#
Admixtures (specify)
Total Yards Placed: 18
Coarse Agg. (size/Ibs.):
42 oz. Delvo Stabilizer
Specified Strength (psi): 3000
Coarse Agg. (size/Ibs.):
Sampling and Casting of Samples
Additional-Tests/Data
Obtained
ASTM C 31, C 109
ASTM C939
Time Cubic
Grout
Ambient Truck Ticket
Size: Set#.
Cast Yards Flow
Temp
Temp No. No.
Cast Samples: 1-5
9 n/a
55°
45° 274 114233
Cast Samples: 6-10
18 n/a
61 °
540 285 114334
Weather: Fair; mid 40's to mid 50's
Date Samples Picked Up: 10/29/2013
Comments
Other Test Methods / Standards Used:
REINFORCING / PLACEMENT: Conforms Does Not Conform _
TEST RESULTS
Specimen Test Field Age
Size Area
Max Load
Strength Type of Fracture
Number Date Cure (Days)
(in.) S .In. Weight .
L( bs-)
si (other than cone)
1 10/31/13 3
2x4 3.14 .84#
12,070
3840
2 11/4/13 7
2x4 3.11 .87#
16,050
5160
6 10/31/13 3
2x4 3.14 .89#
10,830
3450
7 11/4/13 7
2x4 3.11 .87#
15,710
5050
Tested in general accordance to: ASTM C39 x ASTM C78 ASTM C109ASTM C617 ASTM C1231
Note: Type of fracture does not apply when testing. in conformance to ASTM C1231
Copies to: %)
X Client Contractor
X Architect X Building Dept. Technical Responsibility: i
Engineer Anthony Coyne,,Profesiionalpfigineer
This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau & Associate , c. Reproduction of this report,
except in full, without written permission from our firm is strictly prohibited.
Page 1 of 1
6747 M.L. King Way S., Seattle, Washington 98118 — Phone (206) 725-4600 or 1-888-OTTO-4-US — Fax (206) 723-2221
Form No.: ADMIN-71-04 (Rev 05113)
OTTO ROSENAU .7, ASSOCIATES, INC ;
j Geotechnical Engineering, Construction Inspection & Materials Testing
GROUT REPORT
Rece,v
t
COUIVTSERVICE,
Job Number: 13-0684 Report Number: 125916 Permit Number: BLD 2012-0858
Project: Olson Residence — Edmonds Client: George & Ginger Olson
Address: 15500 75"' Place West, Edmonds Address: 1550075 Place W, Edmonds
Date: 10/29/13 Inspector: Gordy Moe
Description / Location: Augered and cast in -place pile numbers 9, 10, 11, 21, and 22. Reinforcing steel as per the approved plans
and specifications for size, grade, and spacing.
Resteel grade: 60 Manufacturer: Cascade Mills
Placement, Data Batch Weights
Supplier: Cadman Cement (Ibs/type.): 846# 1/11 . Water (Ibs./gal): 450#
Mix Number: 3GO0149 Fine Agg. (Ibs.): 2357# Admixtures (specify)
Total Yards Placed: 18 Coarse Agg. (size/Ibs.): 42 oz. Delvo Stabilizer
Specified Strength (psi): 3000 @ 28 Coarse Agg. (size/Ibs.):
days
Sampling and Casting of Samples Additional Tests/Data Obtained
ASTM C 31, C 109 ASTM C939
Size: Set #
Cast Samples: 1-5
Cast Samples: 6-10
Weather: Fair, Mid 40°F-Mid 50°F
Date Samples Picked Up: 10/30/13
Contractor: McDowell N.W.
Other Test Methods / Standards Used:
Specimen
Number
1
2
6
7
Test
Field Age
Date
Cure (Days)
11/1/13
3
11/5/13
7
Time Cubic
Grout
Ambient
Truck
Ticket
Cast Yards Flow
Temp
Temp
No.
No.
9 n/a
640
47°
310
114479
15 n/a
620
540
285
114679
Comments
REINFORCING / PLACEMENT:
Conforms
X
Does Not Conform
TEST RESULTS
Size
Area
Max Load
Strength
I(.)
(Sg.In•) Weight
L( bs•)
i2§jI
2x4
3.14 .95#
9330
2970
2x4
3.14 .90#
13,870
4460
-s
11 /1 /13 3 2x4 3.14 .98# 11,100 3540
11/5/13 7 2x4 3.11 .90# 12,840 4130
Tested. in general accordance to: ASTM C39 x ASTM C78 ASTM C109 ASTM C617
Note: Type of fracture does not apply when testing in -conformance to ASTM C1231
Type of Fracture
(other than cone)
ASTM C 1231
Copies to:
X Client Contractor
X Architect X Building Dept: Technical Responsibility:
Engineer Anthony Coyne, rofessional Engineer
This report applies only to the items tested or reported and is the.exclusive property of Otto Rosenau & Associates, Inc. Reproduction of this report,
except in full, without written permission from our firm is strictly. prohibited.
Page 1 of 1
6747 M.L. King Way S., Seattle, Washington 98118 - Phone (206) 725-4600 or 1-888-OTTO-4-US - Fax (206) 723-2221
Form No.: ADMIN-71-04 ,(Rev 05113)
OTT®. ROSENAU �'ASSOCIATES, INC.'
Geotechnical Engineering, Construction Inspection & Materials Testing ���'��
NOV ? 1 2013
CONSTRUCTION INSPECTION REPORT DEVELOPMENT SERVICES
COUNTER
Report Number: 266335
Project: Anthony's Beach Cafe Permit Number: 2013-0313
Address: 456 Admiral Way, Edmonds Job Number. 13-0422
Client: Anthonv's Restaurants Client Address: PO Box 3805. Bellevue. WA 98009
Inspections Performed .
Steel Decking
Other (specify): Welds at kitchen / .
hoods and duct
X
Other (specify):
Structural Steel Fabrication
Structural Steel Erection
Inspector
and Date Remarks
Tom Maddock Performed visual inspection of welds at (2) kitchen exhaust hoods and ventilation ducts. These welds
10/30/13 had a continuous butt welded connection at duct to duct pieces and duct to hoods. Welder was Ryan
Patton. Welding was done with a metal inert gas ( MIG) Welder.
Conforms
.o
Copies to:
X Client X Engineer Others kHeff X Owner Contractor Technical Responsibility:X Architect X Building Dept Rabe, Project Manager
This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau & Associates, Inc. Reproduction of this report,
except in full, without written permission from our firm is strictly prohibited.
Page 1 of 1
6747 M.L. King Way S., Seattle, Washington 98118 - Phone (206) 725-4600 or 1-888-OTTO-4-US - Fax (206) 723-2221
Form No.: ADMIN==63-05 (Rev 10/10)
RECEIVED
OTTO ROSENAU & ASSOCIATES, INC. rcr 10 2013
Geotechnical Engineering, Construction Inspection & Materials Testing nnAlFPr iz�nj
COUNTER
GROUT REPORT
Job Number: 13-0684 Report Number: 125915 Permit Number. BLD2012-0858
Project: Olson Residence - Edmonds Client: George & Ginger Olson
Address: 15500 75`' Place West, Edmonds Address: 15500 75"' Place W, Edmonds
Date: October 28, 2013 Inspector Gordon Moe
Description / Location: Inspected angered and cast in place pile #'s: 1, 2, 3, 12, 13, 15 and 16. Reinforcing steel as per the approved
plans and specifications for size, grade and spacing.
Resteel grade: 60 Manufacturer:
Cascade Mills
Placement Data
Batch Weights
Supplier: Cadman
Cement (Ibs/type.):
846# 1/II
Water (Ibs./gal): 450#
Mix Number: 3GO0149
Fine Agg. (Ibs.):
2357#
Admixtures (specify)
Total Yards Placed: 18
Coarse Agg. (size/Ibs.):
42 oz. Delvo Stabilizer
Specified Strength (psi): 3000
Coarse Agg. (sizeAbs.):
Sampling and Casting of Samples
Additional
Tests/Data
Obtained
ASTM C 31, C 109
ASTM C939
Time Cubic
Grout
Ambient Truck Ticket
Siie: Set #
Cast Yards
Flow
Temp
Temp No. No.
Cast Samples: 1-5
9
n/a
550
45°. 274 114233
Cast Samples: 6-10
18
n/a
61 °
54° 285 114334
Weather. Fair, mid 40's to mid 50's
Date Samples Picked Up: 10/29/2013
Comments
Other Test Methods / Standards Used:
REINFORCING / PLACEMENT: Conforms X Does Not Conform
TEST RESULTS
Specimen Test Field Age
Size Area
Max Load
Strength Type of Fracture
Number Date Cure (Days)
(In.) (So.In.)
Weight
L( bs.)
inga bother than cone)
1 10/31/13 3
2x4 3.14
.84#
12,070
3840
2 11 /4/13 7
2x4 3.1.1
.87#
16,050
5160
3 11/25/13 28
2x4 3.14
.90#
17,670
5630
4 11/25/13 28
2x4 3.14
.87#
17,820
5680
5 11/25/13 28-
2x4 3.1.4
.88#
18,560
%910
6 10/31/13 3
2x4 3.14
.89#
10,830
3450
7 11/4/13 7
2x4 3.11
.87#
15,710
5050
8 11/25/13 28
2x4 3.14
.85#
15,150
4830
9 11/25/13 28
2x4 3.14
.85#
17,640
5620
10 11/25/13 28
2x47 3.14
.88#
17,710
5640
Tested in general accordance to: ASTM C39 x ASTM C78 ASTM C109
Note: Type of fracture does not apply .when testing in conformance to ASTM C1231
ASTM C617 — ASTM C1231
Copies to:
X Client Contractor , Z,
X Architect X Building Dept Technical Responsibility:
Engineer Anthony CoyFReproduction
rofessiona ngineer
ciates IThis report applies only to the items tested or reported and is the exclusive property of Otto Rosenau & Assoof this report,
except in full, without written permission from our firm is strictly prohibited.
Page 1 of 1
6747. M.L. King Way S., Seattle, Washington 98118 -- Phone (206) 725-4600 or 1-883-0TTO-4-US - Fax (206) 723-2221
Form No.: ADMIN-71-04 (Rev 05113)
I/
DATE:
�-1-7-aola
OWNER(S): GL,Dr2�� � Vlf4�ajrJJA 01GOAf
PROPERTY ADDRESS: 15.600 7S7_11 �� ��monl�si uiA
TAX PARCEL ID #
LEGAL DESRCIPTION
SEC 05 TWN Z7 /V RNG 4' E OTR or NW �//C/-
LOT BLK PLAT
THE UNDERSIGNED OWNERS OF THE ABOVE DESIGNATED PROPERTY DO
HEREBY ACKNOWLEDGE THE FOLLOWING:
That the accuracy of all permit submittal information is warranted , by the
applicant/owner in a form which relieves the City and its staff from any liability
associated with reliance on such permit application submittals.
• While an application may reference the reports of prior public consultants to the City, all
conclusions shall be those of the applicant/owner and her/his design professionals.
s That the applicant/owner understands and accepts the risk of developing in an area with
potential unstable soils and understands the required temporary and permanent erosion
control and site maintenance issues associated with specific geologic hazards or conditions
of the site that may affect slope stability over time.
• That they will advise, in writing, any prospective purchasers of the site, or any
prospective lessees of structures on the site, of the slide potential and on -going
maintenance issues of the area and on the property.
RECE FED
AUG 2 3 2012
DEVELOTM CTR.
OF EDMONDS
CITY copy
WASHINGTON SHORT -FORM INDIVIDUAL ACKNOWLEDGMENT (RCW 42.44.100)
State of Washington
1 ss.
County of :5 nn ' 1,� `o � � 1\
I certify that I know or have satisfactory evidence that 6�gG i I ��
Name of Signer
is the person who appeared before me, and said
person acknowledged that he/she signed this
instrument and acknowledged it to be his/her
free and voluntary act for the uses and_purposes
mentioned in the instrument.
Dated: I
onth/DayNear
Signature of Notarizing Officer
Stm of Washingft
Lucas A pi _�
My Appointment Expireses Oct Oct 19. 2015 Title (Such as "Notary Public")
My appointment expires
Place Notary Seal and/or Stamp Above Month/DayNear of Appointme t Expiration
OPTIONAL
Although the information in this section is not required by law, it may prove valuable to Top of thumb.here
persons relying on the document and could prevent fraudulent removal and reattachment of
this form to another document.
Description of Attached Document
Title or Type of Document: ?_GnPJ_V
Document Date: g— ' — d� Number of Pages:
Signer(s) Other Than Named Above:
0 2010 National Notary Association - NationalNotary.org • 1.800-US NOTARY (1.800-876-6827) Item s.19U0
VICINITY. MAP
Not to Scale
I-'WiJ at OW
0. 1100, fts ', V i r
iJ�.A f J
JI �tA
Fish
Project - �
_ _ ' ii
E. 1��. t [- - -
Site � r[152 nd st SW a
i1} S9O D L4 Clr11$ C 7"
Ga!;r ty Para _ 156th St S�v-
y
rD
tj I t �l .i�Z .._...!• -! L. —" ice--. ;,.�-; r',5
IaEe^�11.
N--=-
___w. J
i v 16dth,StSx �
rT
Ac �es
o' • f M1 ''1 ��p i �eYe r
Oth St S%v
RES
�172nd PI SW �t _
C120i1M1 TECH_-_ aL
Lynnwood, WA
RECEIVE®
AUG 2 3 2012
DEVELO TM 0 EDMO'CE CTR.
Project Number
83421311 Olson Residence
Vicinity Map
NELSON GEOTECHNICAL
N^ A ASSOCIATES, INC.
GEOTECMNICAL ENGINEERS & GEOLOGISTS
No. I Date I Revision I By
1 i 3/25/11 i Original i DPN
OV EDAf
04,
Fat.. t 89�
File -No":
�ttp 4f mlonh Applicant:
Affidavit of Earth Subsidence Landshde Hazard Axea
Permit Posting
RECEIVE®
btate of a jingtott. :}
AUG 23 2012
— DEVELOPMENT SERVICES CTR.
county of .6nobont[5b } CITY OF EDMONDS
being first duly sworn, on oath,;
deposes_and says:
That on the a� day of A(,(�'��CS ,20� a site located at
DO cog DODOD 10 lfi was posted as
prescribed by Ordinance No. 3632 on the subject property. 'Phis posting begins on j
ion the day the City accepts the Permit Application for review and shall remain until
building occupancy is granted.
_ i5igtied
Signed: `
Subscribed and swrn oto .befoie me this day of 20'
i`PrintedName:-�
Notary PuMeotary Public in and for the State of Washington, residing at
State of washln$10 —
LUCAS A M EVANS -
My Appointment Expires Oct 19.2015
1Gfy ionn expires' j
Wemp/Building/Meadow/Affidavit 4/07
i
RETURN ADDRESS-
City of Edmonds, City Clerk
121 5th Avenue North
Edmonds, WA 98020
201310110420 CONFORMED 5OPY PGS
SNOHOMISH3COUNTY, WEHINGTON
COVENANT OF NO'IMCAATION
AND INDEIVINII'ICAI'ION/HOLD HARIlMESS
Reference #: 2�13?
Grantor(s)• (1)4!'5 (2)// ��� ��Additional on pg.,
Grantee(s): Citv of Edmonds .))
Legal Description (abbreviated): Sec &vr Twn v�-ZXI Rng
OR Lot Block Plat
Assessor's Tag Parcel 11DR(s): (1)41 ��%�%G � (2)
Assessor's Tax Parcel 1D# not yet assigned
.CITY OF EDMONDS
• APPROVED FOR RECORDING
BY: A DATE:& AFFAGE L OF�
Under the review procedures established pursuant to the State Building Code,
incorporating amendments promulgated. by the City of Edmonds, and as a
prerequisite to the issuance of a building permit for the construction of a residential
structure and attendant facilities, the undersigned OWNERS of property do hereby
covenant, stipulate and promise as follows:
1. Description of Subject Property.
APP 0
PIVIT FOR RECORDING:
DATE: -
PA_ OF
This covenant of notification and
indemnification/hold harmless relates to a tract of land at the street address of
(insert street
address), Edmonds Snohomish County, Washington and legally described as:
Pr rJ Lc lI L-V A/ O )::� LV L-l\i LX / S i f� ALs o
10 r-7- 1--0l I L% W or V✓ 4W or (;--x i 3
or
j5AM oRD .3a L?3 r2IE4, 4F22,2 L03 01g7
2. Notification and Covenant of Notification: The above referenced site
(hereinafter "subject site") lies within an area which has been identified by the City
of Edmonds as having a potential for earth subsidence or landslide hazard. The
risks I associated with development of the site have been evaluated by technical
consultants and engineers engaged by the applicant as a part of the process to
obtain a building permit for the subject site. The results of the consultant's reports
and evaluations of the risks associated with development are contained in building
permit tile numbercxOD�!�Dg�i (insert number) on file with the City of
Edmonds Building Department. Conditions, limitations, or prohibitions on
development may have been imposed in accordance with the recommendations of
APPROOVEDFOR RECORDING:
DATE:
PAGE _ OF I
the consultants in the course of permit issuance. The conditions, limitations, or
prohibitions may require ongoing maintenance on the part of any owner or lessee or,
may require modifications to the structures and earth stabilization matters in order
to address future or anticipated changes in soil or other site conditions. The
statements and conditions proposed by the OWNERS' geotechnical engineer,
geologist, architect and/or structural engineer are hereby incorporated by reference
from the contents of the file as fully as if herein set forth. Any future purchaser,
lessee, lender or any other person acquiring or seeking to acquire an interest in the
property is put on notice of the existence of the content of the file and the City urges
review of its contents. The file may be reviewed during normal business hours or
copies obtained at the Building Department, City of Edmonds, 121 Sth Avenue
North, Edmonds, Washington 98020.
3. Indemnification and Hold Harmless. The undersigned OWNERS
hereby waive any and all liability associated with development, stating that they
have fully informed themselves of all risks associated with development of the
property and do therefore waive and relinquish any and all causes of action against
the City of Edmonds, its officers, agents and employees arising from and out of such
development. In addition, the.OWNERS on behalf of themselves, their successors in
interest, heirs and assignees, do hereby promise to indemnify and hold harmless the
City of Edmonds, its officers, agents and employees from any loss, claim, liability or
damage of any kind or nature to persons or property either on or off the site
resulting from or out of earth subsidence or landslide hazard, arising from or out of
the issuance of any permit(s) authorizing development of the site, or occurring or
APPR— (YED FOR RECORDING:
BY: 6'ih�s av?— DATE:
PAGE— XI^ OF _�j
arising out of any false, misleading, or inaccurate information provided by the
OWNERS, their employees, or professional consultants in the course of issuance of .
the building permit.
4. Insurance Requirement. In addition to any bonding which may be
,required during the course of development, the Community Services Director
has/has not (strike one) specifically required the maintenance of an insurance policy
for public liability coverage in the amount and for the time set forth below in order
to provide for the financial responsibilities established through the indemnification
and hold harmless agreement above:
5. Covenant to Touch and Concern the Land. This cosenant of
notification and indemnification/hold harmless touches and concerns the- subject
tract and shall run with the land; binding, obligating and/or inuring to the benefit of
future owners, heirs, successors and. interests or any other person or entity
acquiring an interest in property, as -their interest may appear. This provision shall
not be interpreted to require a mortgagor or lender to indemnify the City except to
the extent of.their loss nor to obligate such persons to maintain the insurance above
required.
DONE this l day of
ONVNER(S)
By:
By: _ Gia
By
STATE OF WASIIU GTON )
) ss:
COUNTY OF ����IS)
I certify that I know or have satisfactory evidence that CSON
signed this instrument and
acknowledged it to be (his/her) free and voluntary act for the purposes mentioned in
this instrument. 7�J
DATED this ��LL� day ofeo-
Notm PUM NOTARY PUBLIC 7 l
Sto Of W"NON My commission expires: o� /
UMA USUANOVA r`
MY Appointment ExOm Sep 27, 2014