bld20120895_Borgeson_ENG3.pdf City of Edmonds TH 121 5AVENUE NORTH •EDMONDS, WA 98020 • (425) 771-0220 FAX (425) 771-0221 Website: www.ci.edmonds.wa.us PUBLIC WORKSDEPARTMENT EngineeringDivision Plan Review Corrections Plan Check :Date: #BLD201200895May 24, 2013 th Project Name/Address: BorgesonSFR7822 240St SW Contact Person/Address/Fax: Scott Borgeson–Community Builders Group scott@borgeson.us___ Reviewer:Jennifer Lambert Division:Engineering During review of the subject submittal,it was found that the following information, corrections, or clarifications wouldneed to be addressed. All Handoutsand Standard Detailsreferred to in these comments can be accessed at our website: www.ci.edmonds.wa.usby clickingCity Government / City Department / Public Works/ EngineeringDivision: Review 1 –11/16/12 Review 2 –5/24/13 Review 3 –9/9/13 Short Plat Requirements 1.9/9/13 –Applicant responded to comment; however, the City is not able toacceptpayment in lieu of the construction for the frontage improvements.Although you have stated that youhadan agreement with the City, the city has no record of such agreement and payment was never received. PerRCW 82.02.020and the City’s Transportation Comp Planthe Cityis not able to accept payment in lieu unless the funds can be expended within 5 years. Therefore, if the project is not identified in thecurrent Capital ImprovementProgram on the street that the subject developmentis located, frontage improvements are required to be completed by the developer. Please show the installation of the curb/gutter and sidewalk on the plans, consistent with the engineering requirements establishedwith the short plat. 5/24/13–Applicant responded to comment;however, the City has not found any evidence that there was a fee paid to the City for sidewalk improvements at a different location. When looking at the short plat file there was a cost estimate completed that shows that a bond would need to be in place for the short plat improvements in order to record the short plat. In the cost estimate used to calculate the bond amount the curb/gutter and sidewalk was calculated at $25LF *90 ft.= DATE FAXED/E-MAILED9/9/2013PAGE ___ OF __ 13 $2250.00. Please provide documentation (i.e. receipt of payment, etc.)showing proof that there was a payment made or show on the plans the installation of curb/gutter and sidewalk. Comment 11/16/12 -The sidewalk and Curb/Gutterwas deferred to the constructionof the short plat.As stated in the Engineering Requirement of the subdivision S-99-238recording number #200101295001, 5’sidewalk and curb/gutter shallbe installedas a condition of subdivision th along the frontage of 7822 and 7824240St SW. Please show required improvements on site plan and add City of EdmondsStandard Details E2.26, E2.28 and E2.13. Plot Plan 1.OK Additional Comment 5/24/13: 2.OK Site, Drainage, TESC,and Utility Plan Erosion Control: .OK 1 3.OK Utilities : 1.OK 2.OK 3.OK 4.OK 5.OK 6.OK 7.OK Grinder Pump : 1.9/9/13 –Applicant responded to comment; however, a predesign report is required for ALLpumps as outlined in handout #E62. 5/24/13–Comment was not addressed. It is true that the E-One is an acceptable pump. This means that the pump does not have to be peer reviewed; however, it is still required that a predesign report be submittedas outlined in handout #E62. DATE FAXED/E-MAILED9/9/2013PAGE ___ OF __ 23 11/16/12 Comment: Please review Handout #E62 for requirements for a single family residential sewage pump. “Apre-design report to justify the installationof a pump station must be submitted to the City Engineer prior to design.” Checklist and standard details arealso providedin the handout. Requirements include “The engineer of record must be registered in the State of Washington and have had prior experience in designing similar systems to the satisfaction of the City Engineer. Qualifications shall be included within the design report.” The city has completed reviews and have approved the following packaged grinder pump stations: i.Myers ii.Barnes iii.Hydromatic iv.Zoeller 840 Series. If you intend to use the E-One model or a model not in the above list, the system will need to bepeerreviewedand associated fees will be applied. Please submit documentation that shows that the model you propose meets the requirements outlined in Handout #E62. 4.OK Drainage: 1.OK 2.OK 3.OK 4.OK 5.OK Additional Comment: 6.OK Please resubmit 3 copies of the revised plans/documents to a Development Services Coordinator.Please contact meat 425-771-0220 if you have specific questions regarding these plan corrections. DATE FAXED/E-MAILED9/9/2013PAGE ___ OF __ 33