BLD20130011_Parashar_ENG1.pdf City of Edmonds BLD20130011 TH 121 5 AVENUE NORTH EDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221 Website: www.ci.edmonds.wa.us PUBLIC WORK DEPARTMENT Planning • Building • Engineering Engineering Plan Review Comments Permit Application :Date: # BLD20130011 January 11, 2013 st Project Name/Address: Parashar – 20129 81 Ave W Contact Person/Address, Fax or E-mail: rajanparashar7@gmail.com Reviewer: JENNIFER LAMBERT Division: ENGINEERING During review of the subject submittal, it was found that the following information, corrections, or clarifications would need to be addressed. All Handouts referred to in these comments can be accessed at our website: www.ci.edmonds.wa.us under City Government / Development Services Department / Engineering Division then scroll down to Handouts: 1)Please add the impervious surface chart (provided in the E72 Handout) to the Site Plan, as shown below. Line Type Area (square feet) 1. Non-Regulated Exempt Regulated 2. Replaced 3. New (Post 1977) + Total Regulated Impervious Area = 4. Mitigation required if in excess of 2000sf - 5. Total Area Mitigated by Existing Stormwater Management System(s) = 6. Regulated Area Not Yet Mitigated = 7. Area Proposed to be Mitigated by Low Impact Development Techniques = 8. Area Proposed to be Mitigated through Conventional SWM Techniques 2)Please complete and submit the Stormwater Worksheet found in Handout #E72. 3)Please show all impervious surfaces on the site plan (i.e. sheds, rooftops, asphalt, concrete, gravel, patios, walkways, etc). 4)Please clearly show the existing and proposed roof lines. If the rooflines are not changing please note as such on the plans. DATE E-MAILED 1/11/2013 PAGE(1) City of Edmonds BLD20130011 TH 121 5 AVENUE NORTH EDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221 Website: www.ci.edmonds.wa.us PUBLIC WORK DEPARTMENT Planning • Building • Engineering Engineering Plan Review Comments 5)Please clearly show the proposed area to be constructed/altered. 6)Please note the year of construction for all impervious surfaces on the Site Plan. 7)Please show the water service line from the meter to the house. 8)Please show the side sewer from the main to the house. 9)Please add a note that all disturbed soils will be compost amended per Handout E72C. 10)Please show all fences, retaining walls, and rockeries that are located on the subject property. Please resubmit 3 copies of the revised plans and associated documents with a written response to each item to a Permit Coordinator. Please contact me at 425-771-0220 ext 1321 or by e-mail at jennifer.lambert@ci.edmonds.wa.us if you have specific questions regarding these plan corrections. DATE E-MAILED 1/11/2013 PAGE(2)