bld201301404_McGinness_ENG2.pdf City of EdmondsBLD20131404 TH 121 5AVENUE NORTHEDMONDS, WA 98020 • (425) 771-0220 FAX (425) 771-0221 Website: www.edmondswa.gov PUBLIC WORK DEPARTMENT Planning • Building • Engineering Engineering Plan Review Comments PermitApplication:Date: #BLD201301404 March 25, 2014 Project Name/Address: McGinness –726 Sprague St Contact Person/Address, Fax or E-mail: Chris McGinness –cmcginness@frontier.com Reviewer: JENNIFERLAMBERTDivision: ENGINEERING During review of the subject submittal, it was found that the following information, corrections, or clarifications would need to be addressed. All Handouts referred to in these comments can be accessed at our website: www.edmondswa.govunder City Government / Development Services Department / Engineering Division then scroll down to Handouts: st 1Review –2/12/14 nd 2Review –3/25/14 ROAD & DRAINAGE PLAN GENERAL 1)3/25/14–Comment was addressed; however, the sidewalk should be placed at the back of the existing curb/gutter. Please revise the plans to show the existing curb/gutterand the new sidewalk. 2/12/14 Comment: Consistentwith EdmondsCommunity DevelopmentCode(ECDC)18.90, a sidewalkis requiredon Sprague St. Please show a 5’ sidewalk along the frontage of the subject parcel installed per Edmonds Standard Detail E213. a.Since the sidewalk slopes towards the street, the impervious surface runoff from the sidewalk does not have to discharge to the onsite stormwater management system. However the area of sidewalk needs to be calculated into the impervious surface calculations 2)3/25/14–Comment b. was not addressed. Please show how the runoff from the alley will be collected to the onsite stormwater management system. 2/12/14 Comment: Please clearly distinguish between the existing improved portion of the alley (gravel/paved area) and the proposed alley improvements. a.OK DATE E-MAILED3/25/2014PAGE (1) City of EdmondsBLD20131404 TH 121 5AVENUE NORTHEDMONDS, WA 98020 • (425) 771-0220 FAX (425) 771-0221 Website: www.edmondswa.gov PUBLIC WORK DEPARTMENT Planning • Building • Engineering Engineering Plan Review Comments b.Please show howthe surface water runoff from the new improved portions of the alley will be directed to the onsite stormwater management system. 3)OK 4)OK 5)OK 6)OK 7)3/25/14–Comment was addressed. However, please reference the detail (section B-B) on theplot plan. 2/12/14 Comment: The slope for the alley shown on ‘Profile Section “A-A”’ (on sheet 1 of 3)and ‘Alley Section –B-B’ (on sheet 3 of 3) arenot consistent. Please revise the plans to show the alley with no greater than a 2% cross slope. 8)OK 9)OK 10)OK 11)OK 12)3/25/14 –Comment was addressed. However, ifthe ‘Cant’ed Fnd Wall’detailwas added for the purpose of providing information on the retaining walls, thedetail does not match what is proposed on the plans. Please provide a detail for the retaining wallthat also includes the top and bottom a. elevations. Please remove the ‘Cant’ed Fnd Wall’detail from the Plot, Road, & Drainage Plan. b. 2/12/14 Comment: A rockerydetail is shown on the plans. However, if there is a surcharge on the rockery (by the driveway or structures), an engineered retaining wall is required. c.Please provide bottom and top of retaining wall/rockery elevations. d.Please provide engineering calculations if required. New Comment–3/25/14 13)Please explain what the solid rectangle blocks representon the plans. DATE E-MAILED3/25/2014PAGE (2) City of EdmondsBLD20131404 TH 121 5AVENUE NORTHEDMONDS, WA 98020 • (425) 771-0220 FAX (425) 771-0221 Website: www.edmondswa.gov PUBLIC WORK DEPARTMENT Planning • Building • Engineering Engineering Plan Review Comments DRY UTILITIES 3/25/14–Comment a. was partially addressed. The plans indicate a 2’ separation; however, the 1) minimum requirement is 3’. Please revise the plans accordingly. 2/12/14 Comment: Please show the location of the dry utilities on the plans (i.e. power, cable, phone, gas, etc.) a.A minimum of 3’ separation is required between the dry utilitiesand sewer, water, and storm. Please show that the separation can be achieved. OK b. SEWER OK 1) OK 2) OK 3) OK 4) 3/25/14–Comment was addressed; however, the plans now state that there will be the 12” 5) lamphole cover at the cleanout at the house. The City does not require the 12” cover, but you may use it if you like. 2/12/14 Comment: Please note what size pipe and pipe material will be used for the side sewer (the portion of the sewer from the property lineto the house). OK 6) WATER 1)3/25/14–Comment was partially addressed. Please show the new water service line since the old line cannot be reused. 2/12/14 Comment: It appears that a fire sprinkler system is required for this property. The existing water service line from the watermain to the meter is not the appropriate size and a new tap will be required. a.Please show the new linefrom the watermain to the house. b.Please show the water meter located at the property line. DATE E-MAILED3/25/2014PAGE (3) City of EdmondsBLD20131404 TH 121 5AVENUE NORTHEDMONDS, WA 98020 • (425) 771-0220 FAX (425) 771-0221 Website: www.edmondswa.gov PUBLIC WORK DEPARTMENT Planning • Building • Engineering Engineering Plan Review Comments c.Please add a note that a 1” meter is to be installed. d.Please label the water service line as 1 ½” and note the pipe materialwith tracer wire. STORM 1)3/25/14–Comment was partially addressed. Although the surface water runoff from the sidewalk does not have to be collected and discharged to the onsite stormwater management system the onsite system must be designed for the square footage of the impervious surface area of the sidewalk. Please revise the impervioussurface calculations and detention system sizing accordingly. 2/12/14 Comment: Impervious surfaces: a)In the ‘Drainage Design Parameters Narrative’it states that the total regulated impervious areais 3,000 s.f (page 2). On page 4 of the report the regulated impervious area is stated as 3,750 s.f. b)On the ‘Road & Drainage Plan’ (sheet 1 of 3) it is stated that the regulated impervious area is 3,917.35. c)On the ‘Profiles, Notes, and Details’ (sheet 3 of 3)it is shown that the total impervious area is 3,750 s.f. a.Please revise all documents/pagesto be consistent. b.Please revise the sizing of the detention system accordingly. 2)OK 3)3/25/14–Comment was partially addressed. Please show all the invert elevations into the proposed catch basin. The east andsouth pipes should be at the same elevations. 2/12/14 Comment: The catchbasin that the subject parcel’sonsite stormwater management system is th proposing to discharge toaprivatecatch basinand flows towards 7Ave, not as depicted on the plans. The City cannot permit thesubject parcel to connect to that catch basin. The outfall line (west)from the private catch basin (PD8-19) isa City stormline. a)Please show the installation of a catch basin at connection to the City System. b)Please provide rim and invert elevations for all pipes connected to the new catch basin. 4)OK DATE E-MAILED3/25/2014PAGE (4) City of EdmondsBLD20131404 TH 121 5AVENUE NORTHEDMONDS, WA 98020 • (425) 771-0220 FAX (425) 771-0221 Website: www.edmondswa.gov PUBLIC WORK DEPARTMENT Planning • Building • Engineering Engineering Plan Review Comments 5)OK 6)OK 7)3/25/14–Unsure if the comment was addressed. Please clearly show where the footing drains outfall to. Footing drains cannot be tied into the onsite stormwater management system unless the system is designed for them. Please show the footing drains discharging to a separate system or the outfall line from the detention system. 2/12/14 Comment: Please show where the footing drains will discharge to. 8)OK TESC AND GRADING PLAN GENERAL 1)OK TESC 2)OK 3)OK CONSTRUCTION SEQUENCE NOTES 1)OK 2)OK PROFILES, NOTES, AND DETAILS 1)OK 2)OK Please resubmit 3 copies of the revised plansand associated documents with a written response to each item to a Permit Coordinator. Please contactme at 425-771-0220ext 1321or by e-mail at jennifer.lambert@edmondswa.govif you have specific questions regarding these plan corrections. DATE E-MAILED3/25/2014PAGE (5)