Loading...
BLD20130392.PDFCOMPLETED U� OF C� o�� CITY OF EDMONDS� 121 5TH AVENUE NORTH - EDMONDS, WA 98020 PHONE: (425) 771-0220 - FAX: (425) 771-0221 STATUS: ISSUED 05/10/2013 Expiration Date: 0511 Parcel No: 00434600201403 �z. Permit 'Project'Address: 18506 OLYMPIC' VIEW .EDMO. LAURIE & PAUL KING-HARRIS HUBER ASSOCIATES A & D CONSTRUCTION 18506 OLYMPIC VIEW DR KEVIN HUBER 14838 JAKE DR SE EDMONDS, WA 98020-2349 11514 NORTHPARK AVE N MONROE, WA 98272 SEATTLE, WA 98133 (425)876-8094 (206)841-0791 (206)949-0549 LICENSE #: ADCONCS936BU EXP:01/31/2015 1 1 1 ENCLOSE EXISTING STAIR - MAIN AND LOWER LEVEL REMODEL - MECHANICAL AND PLUMBING INCLUDED VALUATION: $72,768.00 PERMIT TYPE: Residential PERMIT GROUP: 02 - Addition GRADING: N CYDS: 0 TYPE OF CONSTRUCTION: VB RETAINING WALL ROCKERY: N OCCUPANT GROUP: R-3/U OCCUPANT LOAD: FENCE: N 0 X 0 FT. CODE: 09 OTHER: N ----OTHER DESC: ZONE: RS-12 NUMBER OF STORIES: 0 VESTED DATE: NUMBER OF DWELLING UNITS: 0 LOT #: EXISTING AREA BASEMENT: 0 1 ST FLOOR: 0 2ND FLOOR: 0 PROPOSED AREA BASEMENT: 0 I ST FLOOR: 109 2ND FLOOR: 0 3RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0 3RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 66 '1 i tE UIRED: N 0* PROPOSED: 0 I REQUIRED: W 10 PROPOSED: 24 IRE UIRED: E 10 PROPOSED: 14 4E1GHT ALLOWED:25 PROPOSED:16.08 I REQUIRED: S 4* PROPOSED: 7 iETBACK NOTES:* V-16-85 reduced north and south setbacks to 0' and'4' and increased lot coverage to 40% -no change to, existing setbacks, lot coverage or ieight 1 AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18:27, THIS APP I ATION j§ NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AN ALL F ES ARE PAID. Signature me Released By ATTENTION . IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. UBC 109/ IBC 110/ IRC 110. ONLINE APPLICANT ASSESSOR = OTHER Pd "2z-7.-7s 5.5 �y 41 , 43- -Im r2 ntL, STATUS: ISSUED BLD20130392 CONDITIONS I • Installation, use and maintenance of equipment and components shall be per manufacturer's specifications,, installation instructions, and applicable state codes. Provide manufacture's installation instructions on site for Building Inspector. • Obtain Electrical Permit from State Department of Labor & Industries. 425-290-1309' • Final approval on a project or final occupancy approval must be granted by the Building Official prior to use or occupancy of the building or structure. Check the job card for all required City inspections including final project approval and final occupancy inspections. • Any request for alternate design, modification, variance or other administrative deviation (hereinafter "variance") from adopted codes, ordinances or policies must be specifically requested in writing and be called out and identified. Processing fees for such request shall be established by Council and shall be paid upon submittal and are non-refundable. • Approval of any plat or plan containing provisions which do not comply with city code and for which a variance has not been specifically identified, requested and considered by the appropriate city official in accordance with the appropriate provision of city code or state law does not approve any items not to code specification. • Sound/Noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on weekdays and 10:00am and 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. • Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of whatever nature, arising directly or indirectly from the issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to en:force any ordinance provision. • Maintain erosion & sedimentation control per city standards. INSPECTIONS THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY C014STRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT TIME LIMIT: SEE ECDC 19.00.005(A)(6) BUILDING (425) 771-0220 EXT. 1333 1 ENGINEERING (425) 771-0220 EXT. 1326 1 FIRE (425) 775-7720 1 PUBLIC WORKS (425) 771-0235 1 PRE-TREATMENT (425) 672-5755 1 RECYCLING ('425) 275-4801 When calling for an inspection please leave the following information: Permit Number, Job Site Address, Type of Inspection being requested. Contact Name and Phone Number. Date Prefereed, and whether you prefer morning or afternoon. • B-Plumb Rough In • B-Mechanical Rough In • B-Exterior Wall Sheathing • B-Window Flashing • B-Framing • B-Shower Pan Test • B-Insulation/Energy • B-Building Final OV EDM O Al �O �Si. 1890 City of Edmonds DEVELOPMENT SERVICES RESIDENTIAL BUILDING PERMIT APPLICATION 121 5"' Avenue N, Edmonds, WA 98020 Phone 425.771.0220 2 Fax 425.771.0221 PLEASE REFER TO THE RESIDENTML BUILDING CHECKLIST FOR SUBMITTAL REQUIREMENTS PROJECT ADDRESS (Street, Suite #, City State, Zip): Parcel #: 8 o L.,tm Pl t_., \/Ext) Keo 60-4-d 004 4 ., 00 Z o 140 Subdivision/Lot #: Project Valuation: $ r —I- y- 0 - W 3 fJ).t-, JD eAv,,e� 6,0000 APPLICANT• Phone: Fax: , w-r6-gq ev E1Z /1515ocs� 2-' --07 R Address (Street, City, 9tate, Zip) SI NO2 rrf P/f �l� Ave- e- c'�^-1-t WA '79 / 3 3 E-Mail Address: va& 1-t-7 mr_7 . Cori PROPERTY OWNER: Phone: Fax: A v 1, 407e X i S 4 1, tWIV E _e> 4-('zS- i376 —f3 Address (Street, City, State, Zip): E-Mail Address: V t'►� VC &/ L-A r t 67dQ 16 wfNo- -nm Go LENDING AGENCY: Phone: Fax: rti r- Address (Street, City, State, Zip): E-Mail Address: CONTRACTOR:* Phone: Fax: orJ Address (Street, City, State, Zip): E-Mail Address: 3 D2.`sc o 2?2. A tf-2. R-0Gon15T7ZVcno,J. WA State License #/Exp.,Date: *Contractor must have a valid City of Edmonds business license prior to A p Co NC-3 (- 5 J doing work in the City. Contact the City Clerk's Office at 425.775.2525 City Business License #/Exp. Date: DETAIL SCOPE OF WORK: E N t.05E 0 /h Tl r� Srm x . &f n1 t ��'t7t- _ ✓c'L I'1c Ko�r2- . PROPOSED NEW SQUARE FOOTAGE FOR THIS PROJECT: Basement: C> s . ft. Select Basement Type: Finished ❑ Unfinished 1st Floor: O sq. ft. Garage/Carport: o sq .ft. 2 nd Floor: 10 sq. ft. Deck/Patio: -sq. ft. Retaining Wall: ❑ Yes No Other: s .ft I declare under penalty of perjury laws that the information I have provided on this form/application is true, correct and complete, and thatl am the property owner or. duly authorized agent of the property owner to submit a permit application to the City of Edmonds. Print Name: L/ Fv 1 14 �'�✓ f->ey - ❑ Owner )KAgent/Other (specify): Signature: Date:hl_5 FORM A LABuilding New Folder 2010\DONE & x-£erred to L Building -New drive\Form A.doc Updated: 10/2011 4 OF ED O� DEVELOPMENT SERVICES _ RESIDENTIAL BUILDING PERMIT APPLICATION FORM A 8sr i ago 12156 Avenue N, Edmonds, WA 98020 City of Edmonds Phone 425.771.0220 It Fax 425.771.0221 MECHANICAL Equipment Type Appliance/Equipment Information (new and relocated) E—5T7 N1q Total # Furnace # Gas # Elec # Other: BTUs: <100k >100k Location Air Handler/ACNAV #—Gas #_Elec #_Other: CFM: <100k_>100k_ Location Boiler/Compressor/ # Gas # Elec #_Other: BTUs: <100k, 100k-500k, 500k-1Mil Heat Pump/Roof Top — — Unit HP: <3, 3-15, 15-30 Location Hydronic Heating #—Gas #_Elec _In -Floor, _Wall Radiant, Boiler BTUs: Location Exhaust Fans (single Location: # - Bath # duct) Kitchen # Laundry # —Other: Fireplace #—Gas #_Elec #_Other: Location Other Number of Outlets FUEL GAS Fixture/Appliance Type d 7l r AC Unit --------------- BTUs: Location: Furnace --------------- BTUs: Location: Water Heater -------- BTUs: Location: Boiler ------------------ BTUs: Location: Fireplace/Insert BTUs: Location: Stove/Range/Oven: Dryer Outdoor BBQ: Other: TOTAL OUTLETS PLUNIBtNG Number Fixture Type FIXTURE COUNT Number Fixture Type Water Closet (Toilet) Refrigerator water supply (for water/ice dispenser) ' Sink (kitchen, laundry, lavatory, bar, eye wash, etc.) Water Service Line Tub/Shower Drinking Fountain Dishwasher Bidet/Urinal Hose Bib Pressure Reduction Valve/Pressure Regulator Water Heater Tankless? Yes_ No_ Backflow Prevention Device,(e.g. RBPA, DCDA, AVB) Expansion Tank for Water Heater Hydronic Heat in: Floor Wall Floor Drain/Floor Sink Other: Clothes Washer Other: FORM A L:\Building New Folder 2010\DONE & x-feired to L-Building-New drive\Form A.doc Updated: 10/2011 ¥ / \ � � r � v rn i� C)m u •zm-I 7� m C= < e..� m �. vi 25 m m ® ` q CO Ow ? -C� 0� m o m m N X AD o� O>K C) z r D . . AC) mZ 0 S.0X��j N zLO J Q) r— LS---.-_------- -- V) m 0 x ? Z11w c,+ m �O Z O01Om ?�1 pD o m O z N m m A n __--\ 10 0 _ m _ t5 PL 112.50 11 mX ti O m� O O O 3 D D O O m D m X'-jm + +++ Zi N D() rM0 3C m CD D m tOWO= i00o t0 �1� OM r f+mi I� OOOOn mvD II mm n n tom N�0 o m m io 0� m . co + m N X m O (T m v N X Ln m x Z 74 z t) N O O z n �>x 0 m �m O oo m OXz O�m X- z mDc MzO Z �O m*m m 00 x Ln En 'TJ C7" `o CD e3 j a N N f y f . OF EDA90 NOTICE TO PERMITTEE AND/OR OWNER i.90 199� ❑ PARTIAL APPROVAL ❑ CORRECTION REQUIRED ❑ ENFORCEMENT VIOLATION Owner Permit Numberj�j Job Address �8 'D Site Contact odgd4 fz Type of Inspection ❑ WORK DESCRIBED BELOW HAS BEEN INSPECTED AND APPROVED. ❑ APPROVED PLANS AND JOB CARD MUST BE AVAILABLE TO INSPECTOR ON SITE. CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED AND/OR THE NEXT PHASE OF WORK IS STARTED. RECALL FOR INSPECTION ❑ REINSPECTION FEE MUST BE PAID PRIOR TO NEXT INSPECTION REQUEST. ❑ STOP WORK -UNTIL AUTHORIZED TO CONTINUE BY CITY INSPECTOR. (h Add AWoL,,�IL A4-:hjn ka�, S 4_� dj�aj-c 0K= -4D THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED TO BE CORRECTED BY (DATE) OR PENALTIES MAY BE APPLIED. FOR INSPECTION CALL 425-771-0220 Y-_Building ❑ Planning ❑ Engineering ❑ Fire ❑ Public Works Inspector Date THIS NOTICE TO REMAIN ON SITE White: Permit File Buff: Applicant Prescriptive Energy Code Compliance for Single Family and Duplex Housing: Zone 2 Project Information Contact Information ... ............... .......;o.... j:='. This set of forms has been developed to assist permit applicants documenting compliant i h t e Washington State Energy Code, (2009 edition). This set is for structures built under the IRC and located in Climate Zone 2. The following forms provide much of the required documentation for plan review. The details noted here must also be shown on the drawings (WSEC 104.2). This form is not a substitute for the energy code itself. To obtain a copy of the energy code, go to the following web address. http:/Iwww.energy.wsu.edu/code Glazing to Glazing U-Factor Door 9 Vaulted Wall is a Wall- int a Wall- ext Slab e Option Area U-Factor Ceiling Z Ceiling 3 Above Below Below Floors on % of Floor Vertical Overhead" Grade Grade Grade Grade 0I 12% 0.32 0.50 0.20 R-49 or R-38 R-38 R-21 R-21 R-12 R-30 R-10 Int. TB 2, Adv. R-49 or OII 15% 0.32 0.50 0.20 R-38 R-38 R-19 + R-21 R-12 R-30 R-10 R-5 TB 21 Adv. R-49 or III Unlimited 0.30 0.50 0.20 R-38 R-38 R-19 + R-21 R-10 R-30 R-10 R-5 TB 2, Adv. See WSEC table 6-2 for footnotes l Icml RJ Julcuum MIUA.I1cu W IJUIU111vilI Does not apply. (SEE INSTRUCTIONS) Using Prescriptive Option III. All glazing and doors meet maximum U-factor. Alternate heating size method submitted. ❑ Option 1 or II, Glazing to floor area limit (WSEC 602.7.2) ❑ Area weighted window, skylight or door U-factor (WSEC 602.7.2) ❑ As part of the heating system sizing calculation (IRC M1401.3 & WSEC 503.2.2) Radiant slab: ❑ R-10 foam insulation, continuous with thermal break (WSEC 502.1.4.9) Chapter 9 Options Total of 1 Credit Required Opt. Opt. Description 1a I High Efficiency HVAC Equipment 1 1 b High Efficiency HVAC Equipment 2 1 c High Efficiency HVAC Equipment 3 2 High Efficiency HVAC Distribution System 3a Efficient Building Envelope 1 3b Efficient Building Envelope 2 3c Super -Efficient Building Envelope 3 4a Air Leakage Control and Efficient Ventilation 4b Additional Air Leakage Control and Efficient Ventilation 5a Efficient Water Heating 5b High Effieciency Water Heating 6 Small Dwelling Unit 7 Large Dwelling Unit 8 Renewable Electric Energy i otal credits IIECEIVED APR 16 2013 DEVELOPCO�TERRVICES ❑❑ 11 EJ EJ *1200 kwh ❑ 0.00 WSEC Prescriptive Worksheet (2010 edition) Zone 1 WSUEEP10-010 Copyright 2010 Glazing Schedule Project Information Contact Information Conditioned Floor Area : Sum of UA for Heating System Sizing Sum of All Glazing Areas From Below Glazing to Floor Area Ratio 602.7.2 Exception Ratio (not to exceed 1%)�� Exterior Doors Plan Component Door Percent Width Height Glazing Door Door Sum of Glazing Area, Door Area, and UA (do not include exempt door) Area Weighted U = UA/Area Sum of Area and UA for Heating system size only (include exempt door) Vertical Glazing (Windows, Glazed doors using Exception 602.6 #1) Plan Component Glazing ------------ --------------- ------------------------------- ------------ WSEC Prescriptive Worksheet (2010 Edition) Width Height Qt. Feet inch Feet Inch Sum of Area and UA Area Weighted U = UA/Area Glazing Area UA WSUEEP10-010 Copyright 2010 Overhead Glazing Plan Component Glazing -------- ------------- -- — ------ — ------- Width Height Qt. Feet Inch Feet inch Sum of Area and UA Area Weighted U = UA/Area Doube Glazed Garden Windows Section 602.7.2 Exception Plan Component Width Height ID Description Qt. Feet inch Feet inch ... . ....... — ... ........ ... ............ - .......... .... .... . ........ ... ............ . ......... ..... ................ ... ............ .. ......... ............ ... ....... .... ...... ... .......... .... . ... .. ... .. ... ... . ... ....... ... ..... . . ... ........ ... .......... ............ Sum of Area Sum of Area X 3 (This total is automatically included in the glazing area total.) Glazing UA for Heating System Size Only = Area X 0.63 WSEC Prescriptive Worksheet (2010 Edition) Area UA WSUEEP10-010 Copyright2010 Simple Heating System Size: Climate Zone 2 Project Information Contact Information Indoor Design Temperature 70 Outdoor Design Temperature 0 Design Temperature Difference (AT) AT = Indoor - Outdoor Design Temp 70 Conditioned Floor Area Conditioned Volume Glazing Copy Sum of UA from Glazing Schedule 0 Attic U-Factor X Area = UA R-49 0.027 R-38 Advanced 0.026 Single Rafter or Joist Vaulted Ceilings U-Factor X Area = UA R-38 Vented 0.027 1 1 F==� Above Grade Walls U-Factor X Area = UA R-21 0.056 L-=d Floors U-Factor X Area = UA R-30 0.029 Below Grade Walls U-Factor X Area = UA 2' Depth Walls 0.042 3.5' Depth Walls 0.041 7' Depth Walls 0.037 Slab Below Grade F-Factor X Length = UA 2' Depth 0.59 3.5' Depth 0.64 7' Depth 0.57 Slab on Grade F-Factor X Length = UA R-10 2' perimeter 0.54 R-10 Full - Heated 0.55 Sum of UA Envelope Heat Load OBtu / Hour Sum of UA X AT Air Leakage Heat Load 0 Btu / Hour ((Volume X 0.6) X AT) X .018)) Building Design Heat Load Btu / Hour Air Leakage + Envelope Heat Loss Building and Duct Heat Load 0 jBtu / Hour If ducts are located in unconditioned space: Sum of Building Heat Loss X 1.15 If ducts are located in conditioned space: Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 150% Btu / Hour Building and Duct Heat Loss X 1.50 WSEC Prescriptive Worksheet (2010 Edition) WSUEEP10-010 Copyright 2010 TABLE 9»1 ENERGY CREDITS (DEBITSI. . CREDIT(91, la HIGH EFFICIENCY HVAC EQUIPMENT is On, propane or oil=fred'furnace orb oiler with minimum . AFUE of.92% , 1 or Air -source heat putno with miizimiim HSPF a 5.5. 1b iHGII EFFIC NC'i':H'VAC:E ilk EN -2- Closed -loop ground source heat jjuinp; 2 :.... with a numnium Cat' of 3:3. .... _. J c HIGH EFFICIENCY HVAC.EQUIEPMEN:T 3i DUCTLESS SPLIT SYSTEiVI: HEAT PUMPS; ZONAL CONTROL: In. home where tlie:priO4q space heating. system is zonal, 1 elctxic heating, a ductless heat pump systems shall be installed and provide heating to at least one zone of the liousin unit.... 2 MGH EFFICIENCY YI. AC DISTMU.TION. All heatingand coolie stein com ents installed inside . g 3'....... .. Pon the eondit tined space:: A11 combustion: equipment shah be . direct vent or sealed comlbustion. Locating:systeta:compoppts in conditioned cra%vi spaces is 1 not permitted under this option. Electric resistance. heat is not permitted under this -option., . Direct combustion beating equipment with AFL)E less than 80% is.not permitted under tiom 3a EFFIC.IENT:BUILDING ENVELOI'E.1c . . Pxescripuveeoxnpliadce is based on `fable 6-1, Option III with the:follow ng modifications Window U .= .28 Rogr.R=. 39, slab on grade;R-10 full, below grade slab.R-10 fiill.. or 0.5 Component performance compliance: Reduce the Target UA from. Table 5=1.by:5°fo, as determined using EQUATION 1. 3b EFFICIENT BUILDING ENVELOPE 2i . :.. pimnptive.compliance is based ott Table 6-1, Option111 iuith the.followirig modifications: WindowU ;_ .25 and wall R-2'1 p1us;R=4. a;id R 3i8 floor,:slab;ongrade;Raa;full, below grade slab It 10' hill, and R 2 l plus R-5 below glade >aseztient walls.: :. � .. 1 or Component performance compliance; Reduce the Target UA from Table 5.1: by:15�,1u; .as deter determined. using EQUATION i:. 3c SUP)MEFFICIENT BUILDING ENVELOPE-1 WSEC Prescriptive Worksheet (2010 Edition) WSUEP10-010 Copyright 2010 Prescriptive compliance is based on Table 54, Option U1 with the following modifications; Window U :- ,2.2 and . wall. R21 plus R-12 and R-38 floor; slab on grade R40 full; below grade slab R-10 full and .R 21 plus R-12 belowgrade basement walls and R-49 advanced ceiling. and vault. 2 or. :. Component performance compliance: Reduce the Target tlA from Table 5..1. by.30%, as determined using EQUATION 1. Envelope leakage reduced to SLA of 0.00020 liuildiiig envelope pghti ess shall be. considered acceptable when tested air leakage is'less than Specific leakage area of 0.0020 when tested with:a blower door at a pressure difference of SO PA- Testing shall occur after rough in. and after installation of Pencet�rations:ofthe building. envelope,, 0_5 . including. penetrations for utilities;. plumbing; electrical, ventilation. and combustion aonliances. and . All whole:houseventilatigrt.requirti0enfis.as detem iedby Section, M1508 of the Washington State ResidentialCode shall be met with n heat recovery vetttilatioti system in accordance with Section: M1508,7 ofthat Code. 4b ADDITIONA)f. AIR LEAKAGE C,�OIVTRUE AND ........ ......... . EFFICIENT.VENTE iATION Envelope leal90e:reduced to SLA of 0.00015 building Ovelope:tightness shall be considered acceptable when.. tested air leakage is less than. specific. leakage area of 0i00015 #hen_tested with:a.blower door at a.pressure:..:.. difieierice of 56PA. Testtng:shall occur after:rougtt iri and after tns[aila004 of penetratIons of the utldrrig env topee . 1 : . including penetratioh' for utilities; plutftliing= electneal,: . ventilation, aiid coinbiia on appliances. And All whole :house ventilation requirements as determined by Section:M1508 of the Washington State Residential Code :. shall be met with: a.heat recovery:ventilation system in. aecerdance with Section M1508.7 of that Code: 1. 5a EFFICIE T W R:HEAT .:.. .. later heatiidg system shall nnclude one of the fbllowii g . " Gas,:propane in> oil waterheaterwntIt asminiinum E:F:of :: : . :.: or Electric. Waterhleaterwithaminimum:E:I of;93: and for both cases All shower -Mad and kitchen sink faucets: installed: in the house shallmeetbe.rated at 1.75 GPM.or less. All other lavato ,faucets.shall be rated at L0 GPM Or less.2 .: $b IIICH»1~YCIEI�C"f' WATEREATiN:G: Water heating system shall.include one of the following:: Gas, propaae;or oil Water heatcr with a minimum FF-..a or.::.: .. WSEC Prescriptive Worksheet (2010 Edition) WSUEP10-010 Copyright 2010 Solar. water heating supplementing a minimum standard water lieater. Solar water heating Will prolyide a rated minimum savings of 85 .therms or 2000 kWh based on the Solar Rating andeerUfication Corporation (S1 CQ:Annual Performance of OG 300. Certified. Solar Water Heating Systems, OC Electric heat: pump water heater *A ith a uunim,04 EF of 2.0. 6 . . SMALT; DWELLINN6.:VNIT :I.I . Dwelling units less ihan:1500 square feet in floor area with less thain 30U square feet of windo*:,# doox.aiea. Additions. .. toe)dstingbOdingthat. are less than.750 square feet of heatedfloor area. 7 LARC) D'WRY;I,YNC iiNTT.' Dwelling units exceeding 5000 square feet of floor area shall be assessed a deduction for purposes of complying with Section 901:of this Code. $. RENEVABLE :ELECTRIC ENERGY: For, each 1200 kWh of electrical generation provided annually. byon-site wind. or solar equipment a 0.5 credit shall be allowed, up to 3 credits: Generation shall be . calculated°asfollcitvs :.: For :solarelectric systems, the design shall be demonstrated to meet-tlds requirement using'the National Renewable , Energy Laboratory calculator PMATTs. Documentation : noting solar access shall be included on the.plaus, 4.5 For wind generation. projects designs shall document;annual.' • powpT generation based on the.Mowu g factors the wi d ttirb'u>e power: cm :average, .ant►uat wind speed.• at;.the site; frequency diAnbiA on:ofthe:wind sDeedat the .:.:::. . Ote,and.height of the tower Footnotes: I.10teirior: *0 Placement;. Ducts included as Option 2 of Table 9=1: shall, be placed wholly within the .heated envelope of the housing unit;. The: placement shall: be inspected and certified to receive the credits associated with this option: :EXCEPTION.. Ducts:cbmplyfitg witYi this,:section may have up to 5%.ofthe total :lih6ar, feet: of ducts I&aied .in :the exterior caviiaes: or . buffer spaces of the dwelling.:If ilusi:excepdon, is used the ducts will'be tested:to the folio ding.:standards: . Post -construction test: :Leakage to outdoors shalLbe less thatx or equal to l Cr~M per 1 01t2, f:conditioned floor. area When tested at:a pressure differential of 0,1 Pa) :.across the entire -system, including the . manufacturers air handler enclasure.:A11 register boots:shall.be_taped or othise sealed dttiitig the test WSEC Prescriptive Worksheet (2010 Edition) WSUEP10-010 Copyright 2010 2. Plumbing Futures Flow Ratings: Low :flow :plumbing . fixtures: (water closets and urinals). and fittings (faucets and showerheads) Shall comply with the following requirements: (a) Resiidential bathroom lavatory sink . faucets: Maximum. flow rate . 3.8 L/min. (1.0 gailmin) when tested in a:ecordance ivith'ASME-A.112.18.1/CSAB125.1-. (b) Resiclentinl lutehen fincets: lVlax it]ucn flow M .= 6.6 L/rrWn Qj' gad/Mzn) When tested in accordance with ASIv1E Al, 12.18.1%CSA B125.1: (c) Residentia.l sh6werheadsl Wxdmum flow rate. -.6.6 L/min (1.75 gallmin) when tested'in accordance with ASME A112.18.1/CS'A B125.1 WSEC Prescriptive Worksheet (2010 Edition) WSUEP10-010 Copyright 2010 Heating Heating Design Design Temp Temp Aberdeen 20 NNE 25.0 Medical Lake 4.0 Anacortes 24.0 Medina 24.0 Anatone -4.0 Mercer Island 25.0 Appleton 11.0 Metaline Falls -1.0 Auburn 25.0 Methow 2 W 1.0 Battleground 19.0 Mountlake Terrace 22.0 Bellevue 24.0 Mt. Spokane Summit -2.0 Bellingham 2N 19.0 Mount Vernon 3 WNW 20.0 Benton City 2 NW 11.0 Moxee City 10 E 8.0 Bickleton 4.0 Mud Mtn. Dam 23.0 Blaine 17.0 Nespelem 2 S -4.0 Bothell 2 N 17.0 Newhalem 19.0 Bremerton 29.0 Newport -5.0 Brier 24.0 Normandy Park 24.0 Buckley 1 NE 26.0 Northport 2.0 Bumping Lake -5.0 Oak Harbor 16.0 Burlington 19.0 Oakville 20.0 Camas 21.0 Odessa 7.0 Castle Rock 23.0 Olga 2 SE 24.0 Cedar Lake 20.0 Olympia, AP. 17.0 Centralia 21.0 Omak 2 NW 3.0 Central Park 27.0 Opportunity 8.0 Chehalis 21.0 Oroville 5.0 Chelan 10.0 Othello 9.0 Cheney 4.0 Packwood 16.0 Chesaw -11.0 Palmer 3 SE 22.0 Chewalah 2 S -9.0 Parkland 20.0 Chief Joseph Dam 6.0 Pasco 13.0 Clallam Bay 1 NNE 28.0 Plain -3.0 Clarkston 10.0 Pleasant View 16.0 Clearbrook 19.0 Pt. Grenville 27.0 Clearwater 26.0 Pomeroy 3.0 Cle Elum 1.0 Port Angeles 28.0 Clyde Hill 24.0 Port Orchard 29.0 Colfax 1 NW 2.0 Pon Townsend 25.0 College Place 6.0 Priest Rapids Dam 14.0 Colville AP -2.0 Prosser 12.0 Conconully -7.0 Pullman Exp. Sta. 1.0 Concrete 19.0 Puyallup 19.0 Connell 4 NNW 6.0 Quilcene 2 SW 23.0 Cougar 5 E 25.0 Quillayute AP 23.0 Coulee Dam 1 SW 9.0 Quinault RS 25.0 Coupeville 1 S 21.0 Quincy 1 NE 4.0 Cushman Dam 22.0 Rainier, Longmire 15.0 Dallesport AP 14.0 Paradise RS 8.0 Darrington RS 13.0 Raymond 28.0 Davenport 5.0 Redmond 17.0 Dayton 1 WSW 5.0 Renton 24.0 Deer Park 2 E -5.0 Republic -9.0 Des Moines 25.0 Richland 11.0 Diablo Dam 15.0 Rimrock Tieton Dam 4.0 Dishman 9.0 Ritzville 6.0 East Bremerton 29.0 Rosalia 6.0 Edmonds 24.0 Ross Dam 14.0 Electron Headwks 16.0 St. John 15.0 WSEC Prescriptive Worksheet (2010 Edition) WSUEP10-010 Copyright 2010 Ellensburg AP 2.0 Sappho 8 E 23.0 Elma 24.0 Satus Pass 10.0 Eltopia 6 W 9.0 Seattle: Sea-Tac AP 24.0 Elwha RS 24.0 Sedro Woolley 1 E 19.0 Enumclaw 26.0 Selah 11.0 Ephrata AP 7.0 Sequim 23.0 Everett JC 23.0 Shelton 23.0 Everett Paine AFB 21.0 Shoultes 23.0 Fircrest 29.0 Skamania Fish Hatch. 24.0 Forks I E 23.0 Smyrna 8.0 Fort Lewis 24.0 Snohomish 21.0 Fruitvale 1.1 Snoqualmie Falls 22.0 Glacier RS 13.0 Snoqualmie Pass 6.0 Glenoma (Kosmos) 18.0 South Broadway 11.0 Goldendale 7.0 So. Olympic Tree Farm 24.0 Grandview 12.0 Spanaway 20.0 Grapeview 30.0 Spokane AP 4.0 Grayland 2 S 28.0 Spokane CO 10.0 Grays River Hatchery 24.0 Spokane Fairchild AFB 4.0 Greenwater 1.4 Sprague 4.0 Grotto 21.0 Stampede Pass 7.0 Harrington 2 S 3.0 Startup 1 E 20.0 Hartline 7.0 Stehekin 3 NW 12.0 Hatton 8 E 1.0 Steilacoom 21.0 Holden Village 4.0 Stevens Pass 6.0 Hoquiam AP 26.0 Stockdill Ranch -14.0 Ice Harbor Dam 17.0 Sumner 19.0 Inchelium 2 NW 0.0 Sunnyside 12.0 Issaquah 23.0 Tacoma McChord 21.0 John Day Dam 19.0 Tacoma CO 29.0 Kelso AP 24.0 Tatoosh Island 31.0 Kennewick 10 SW 13.0 Thompson Place 20.0 Kent 21.0 Tietort Intake 6.0 Kid Valley 20.0 Toledo AP 17.0 Kirkland 17.0 Toppenish 11.0 Lacey 17.0 Trinidad 2 SSE 13.0 Lacrosse 3 ESE -3.0 Tukwila 24.0 La Grande 23.0 Tumwater 17.0 Lake Cle Elum -4.0 University Place 29.0 Lake Forest Park 20.0 Upper Baker Dam 14.0 Lake Kachess -2.0 Vancouver 22.0 Lake Keechelus 0.0 Vashon Island 28.0 Lakewood Center 23.0 Walla Walla AP 6.0 Landsburg 18.0 Walla Walla CO 13.0 Larson AFB 6.0 Wapato 10.0 Laurier -8.0 Washougal 8 ENE 21.0 Leavenworth -3.0 Waterville 1.0 Lemanasky Lake -7.0 Wawawai 2 NW 14.0 Lind 3 NE 6.0 Wellpinit 1.0 Linwood 10.0 Wenatchee AP 13.0 Little Goose Dam 22.0 Wenatchee CO 10.0 Long Beach 3 NNE 25.0 West Clarkston 10.0 Longview 24.0 Whidbey Island 11.0 Lower Granite Dam 14.0 White River RS 12.0 Lower Monument Dam 18.0 White Swan RS 8.0 Lynden 18.0 Whitman Mission 11.0 Lynnwood 24.0 Wilbur 4.0 Maloft 4.0 Willapa Harbor 26.0 Marietta 3 NNW 18.0 Wilson Creek 3.0 Marysville 23.0 Wind River 15.0 McMillin Res. 21.0 Winthrop 1 WSW -12.0 McNary Dam 11.0 Yakima AP 11.0 WSEC Prescriptive Worksheet (2010 Edition) WSUEPIG-010 Copyright 2010 Washington State Energy Code Prescriptive Worksheet, Climate Zone 2 For All Residential Occupancies 2010 Edition, July 1, 2010 WSUEEP10-010 Prepared by: Gary Nordeen, Luke Howard, Andrew Gordon, Emily Salzberg Funded in part by: The U.S. Department of Energy & Northwest Energy Efficiency Alliance Washington State University Extension Energy Program 905 Plum Street SE P.O. Box 43165 Olympia, WA 98504-3165 E-mail: EnergyCode@energy.wsu.edu Copyright: Washington State University Extension Energy Program* © 2010* *WSUEEP grants limited, conditional permission to Designated Users for: 1. Creation and distribution of free copies of the Spreadsheets and Workbooks, including electronic reproduction; 2. Editing of unprotected cells; and 3. Printing results from the Workbooks; The condition for permission is that the source of any materials copied or used from the Spreadsheets or Workbooks shall be acknowledged as: "Copied by permission from Washington State University Extension Energy Program." No other use or purpose for copying is permitted including, without limitation, changing password protected cells in the Workbooks or selling or using the Spreadsheets and Workbooks in any way calculated to derive profit as a product or service. Report any violations of this Copyright Policy to: EnergyCode@energy.wsu.edu All other rights reserved. Washington State Energy Code Prescriptive Approach - Worksheet Instructions For the Washington State Energy Code, the prescriptive approach is the simplest method of code compliance. However, depending on the prescriptive option and exceptions used, documentation of compliance can be quite complex. This set of forms has been developed to assist permit applicants documenting compliance with the Washington State Energy Code, (2009 edition). These forms are provided as a compliance tool but It is the decision of each individual jurisdiction if completion of them is a submittal requirement. These forms contain embedded formulas and links. They are intended to be completed using Excel® software. The following forms provide much of the required documentation for plan review. The details noted here must also be shown on the drawings (WSEC 104.2). This form is not a substitute for the energy code itself. To obtain a copy of the energy code, go to the following web address. http://www.energy.wsu.edu/code Which worksheets do I need to complete? There are three worksheets included in this set of forms. General Compliance Worksheet: Glazing Schedule Worksheet: Heating Sizing Worksheet: Heating Sizing Worksheet: The energy and residential code requires a heating and cooling sizing calculations for all projects. If you are using this set of worksheets to size the heating system, you will need to complete all the worksheets. If a ACCA Manual J (or equivalent) heating and/or cooling system sizing calculation is submitted, the heating size worksheet does not need to be completed. It is important to note that the codes also require a cooling system size calculation. This form will not provide the cooling calculation. It does not have the needed solar gains function. If a cooling system is included in the submission, perform a Manual J or equivalent calculation. Glazing Schedule Worksheet: There are three reasons to complete the Glazing Schedule. If none apply to your project, you do not need to complete the Glazing Schedule worksheet. A glazing schedule is required to meet the following conditions. 1. The Prescriptive option includes a glazing to floor area limit (WSEC 602.7.2) 2. Not all the windows, skylights or doors comply with the maximum U factor requirement. Qualification will be demonstrated using an area weighted window, skylight or door U factor (WSEC 602.7.2) 3. As part of the heating and cooling system sizing calculation (IRC M1401.3 & WSEC503.2.2) General Compliance worksheet: The General Compliance worksheet documents the prescriptive option chosen to show compliance. It also provides a few checks on insulation compliance that need more detailed input. This worksheet is also used to document the reason for submission of the Glazing Worksheet. If you are choosing a limited glazing area prescriptive option, completing the Glazing Schedule will be the first task. Completing the General Compliance Worksheet This is a simple fill in form. Fill in project information on this worksheet. It will be copied to the other worksheets. Note what options will be chosen to show compliance. Note the glazing documentation included. If you are using an unlimited glazing path, all windows and doors meet the maximum U-factor requirements and a Manual J (or approved alternative) heating system size calculation is submitted, this is the only form that needs to be completed. Completing the Glazing Schedule Worksheet: Exterior Doors: The exterior door section is for swinging doors only. Enter sliding doors in the vertical glazing section of the worksheet. If a swinging door includes glazing, it may be entered in the vertical glazing schedule or in the exterior door schedule. Obtain NFRC tested U-factors from the door manufacturer or use U-factors from WSEC Tables. Table 10-6A Default U-Factors for Vertical Glazing (use for doors with greater than 50% glazing.) Table 10-6C Default U factors for Doors (limited to doors with less than 50% glazing.) Area of windows, doors and skylights are measured using the rough opening area. Glazing area in exterior doors is added to the total glazing area of the project as follows: If greater than 50% 100% of the area is entered in the door glazing area. If less than or equal to 50% only the glazed area will be entered in the door glazing area. Exempt Door: One door, 24 feet or less is not included in the U-factor of glazing area calculations. You must calculate the door area to assure it is 24 square feet or less. This also enters the door heat loss into the heating system size calculation. Vertical and Horizontal Glazing: Obtain NFRC tested U-factors from the glazing supplier. These will give the most accurate and likely the most favorable results. If you can't obtain this data, the tables in Chapter 10 of the WSEC must be used. For default U factors for vertical glazing, refer to table 10-6A If window manufacturer can legitimately be claimed as a "small business" (as defined in Chapter 1 of -the WSEC), you may use table 10-0 for default U factors. Note: the term small business" refers to the glazing manufacturer, not the builder or building owner. For default U factors for overhead glazing, refer to table 10-6E If doors are being entered into the vertical glazing table, refer to table 10-6C and 10-60. Garden Window Exception Schedule The WSEC allows double glazed, unrated garden windows with a wood or vinyl frame to be exempt from the U-factor calculation under the following rules. The total area of this exemption is limited to 1 percent of the conditioned floor area up to a maximum The area of the glazing must be multiplied by 3 and added to the total glazing area for the project Completing the Heating System Size Worksheet This worksheet is used to calculate the design heat load of the structure. It also calculates the maximum heating system size required by code. This worksheet does not perform required cooling load calculations. Use Manual J or equivalent for cooling system size calculations. Go to the Outdoor Design Temperature Worksheet Tab. Locate the outdoor design temperature for a location near the project site. You need to enter the design temperature on this worksheet. Calculate and enter the volume of the interior space in the building (floor area x ceiling height). Measure the dimensions of each exterior building assembly, wall, attic floor etc. Enter the area next to the R-value description that matches the construction. If a construction method is selected that is not represented here, select values from Chapter 10 of the WSEC and enter it in one of the blank spaces at the end of each components section. Enter the correction factor for duct location. If the ducts are indoors, enter 1. If the ducts are in the crawl space, attic or garage, enter 1.15. ID 1 1/2" BRICKMOULD 1x CLEAR CEDAR TO MATCH EXISTING. 1AIu PUNY m McTMI PAINT TO MATCH. NEW SIDING TO L- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - J NEW EAST ELEVATION Scale: 1/4"=r-0" PROVIDE (2) 12" SO. ROOF VENTS NEAR RIDGE. - EXISTING ROOF ASSEMBLY: 1/2" PLYWOOD SHEATHING ROOF TRUSSES O 24'O.C.- NEW R-49 BATT INSULATION - PROVIDE BAFFLES TO MAINTAIN MIN. 1" AIRSPACE. - PROVIDE (3) 1 1/2" DIA. VENT HOLES PER BAY IN EXISTING BLOCKING. - EXISTING GUTTER AND FASCIA. RELOCATE AS REQUIRED. - NEW 1/2" PLYWOOD SOFFIT W/2" CONTINUOUS VENT SCREEN- BRICKMOULD TO MATCH EXISTING W/METAL Z FLASHING AT ALL OPENINGS.- NEW WALL ASSEMBLY: PLYWOOD SIDING TO MATCH EXISTING, BUILDING PAPER, 1/2" COX. 2X6 FRAMING, MIN. R-21 BATT INSULATION, X. GWB, PAINT.- 5/8- ANCHOR BOLTS & 3"SQ. STEEL WASHER. EPDXY INTO EXISTING CONC. FOUDATION WALL - NEW 2X6 TREATED SILL PLATE. - EXISTING GRADE - `NEW 5/8" GWB, PAINT. 1%4 STAINED WOOD TRIM PER SPEC. —5/4 STAINED WOOD 2X TREATED WOOD FURRING ANCHORED TO EXISTING CONC. FOUNDATION == W/R-10 RIGID INSULATION BETWEEN FURRING. 1X6 STAINED WOOD p BASE PER SPEC. 0 NEW FLOOR ASSEMBLY: EXISTING CONIC. SUB TREATED 2X WOOD SHIMS ANCHORED TO CONCRETE, RIGID INSULATION BETWEEN SHIMS, �4 PLYWOOD SUBFLOOR, 'y4: HARDWOOD FLOORING PER SPEC. WALL SECTION I 1 Scale: 3/4"=1'-0" EXISTING CONC. FOOTING AND STEMWALL L- - - - - - - - - - - - - - - - - - NEW NOR TH ELE VA TION Scale: 1/4"=1'-0" RECEIVED APPRn\tq---D BY PLANNING s�l 3 NEW SOUTHELEVATION Scale: 1/4"=1'-0" H Huber Associates ARCHITECTS 11514 N PARK AVE N Sank, WA 96133 Pt— 26G-2S5-4SS2 F.�'I-253-393;1;5 -mn,uer�arcnn NEW ELEVS ®5-1-13 -5.0 Ap 1 19, A113