bld20130593_Barnsdale_ENG1.pdf City of EdmondsBLD20130593 TH 121 5AVENUE NORTHEDMONDS, WA 98020 • (425) 771-0220FAX (425) 771-0221 Website: www.edmondswa.gov PUBLIC WORK DEPARTMENT Planning • Building • Engineering Engineering Plan Review Comments PermitApplication:Date: #BLD20130593 July 3, 2013 th Project Name/Address: Barnsdale –18133–86Pl W Contact Person/Address, Fax or E-mail: Bill Barnsdale –barnsdale.bill@gmail.com Reviewer: JENNIFERLAMBERTDivision: ENGINEERING During review of the subject submittal, it was found that the following information, corrections, or clarifications would need to be addressed. All Handouts referred to in these comments can be accessed at our website: www.edmondswa.govunder City Government / Development Services Department / Engineering Division then scroll down to Handouts: 1)Show the appropriate temporary erosion control measures to beinstalled and note the appropriate City of Edmonds Standards details. 2)Please show the year of construction for all impervious surfaces on the Site Plan (i.e. driveway, gravel access road, walkways, etc.). 3)Please label the year of construction for the garage/deck. 4)Please label the material west of the driveway (where the stairs are located). If this area is impervious please revise the impervious surface calculations accordingly. 5)Per the architecturals(A4), the downspouts drain to an existing drainagesystem. Please show the drainage system on the plans. 6)Please note if the proposed decks are impervious or pervious. a.If the decksare to be pervious please state what material will be below the decks (i.e.grass, dirt, concrete, etc.). b.If the decks are to be impervious, please revise the impervious surface calculations accordingly. DATE E-MAILED7/3/2013PAGE (1) City of EdmondsBLD20130593 TH 121 5AVENUE NORTHEDMONDS, WA 98020 • (425) 771-0220FAX (425) 771-0221 Website: www.edmondswa.gov PUBLIC WORK DEPARTMENT Planning • Building • Engineering Engineering Plan Review Comments 7)Please note if the impervious surfaces added to the lot since 1977 are greater than 2000sq ft., a stormwater management system is required. a.If there is 5000 sq.ft.or more of impervious surfaces the stormwater management system will need to be designed by a licensed engineer. b.Please review all E72 handouts, the City Code, and the Stormwater Supplement for stormwater requirements. c.Please submit a drainage plan consistent withthe City’s Standards. 8)In the architecturals(S2.1) there is a retaining wall detail; however, there is no retaining wall shown on the plans. a.Please show the retaining wall on the Site Plan. b.Please provide footing elevations and top of wall elevations. 9)Show the location of the side sewer from the sewer main to the house. 10)Please show the location of the water service line from the house to the meter. Please resubmit 3 copies of the revised SitePlansand associated documents with a written response to each item to the Permit Coordinator. Please contact me at 425-771-0220ext 1321or by e-mail at jennifer.lambert@edmondswa.govif you have specific questions regarding these plan corrections. DATE E-MAILED7/3/2013PAGE (1)