Loading...
BLD20130605 - Applicant Response to Planning Comments 1.pdfCITY OF EDMONDS ® 1215"' AVENUE NORTH ® EDMONDS, WA 98020 : PHONE: 425.771.0220 o FAX: 425.771.0221 ^ WEB: ��� �_ v.s;a a�u�ruu1(1;�Ngq�,mr : ow DEVELOPMENT SERVICES DEPARTMENT: PLANNING ENGINEERING BUILDING rq o June 26, 2013 l 1� l i'� v v, 014, ra i°k4 o kJ Mr. Steve Waite Email: waitearch@comcast.net RE: PLAN REVIEW COMMENTS FOR PLAN CHECK #BLD20130605 SALINAS GARAGE LOCATED AT 1246 VIEWLAND WAY Dear Mr. Waite: I have reviewed the above building permit application for the Planning Division, and it was found that the following information, corrections, or clarifications will need to be addressed before review can continue: 1. Site Plan: Please indicate all minimum required information on the reduced copy (8.5" by 1 I") of your site plan. Refer to the enclosed sample site plan handout (#B57) for guidance. 2. Height Calculations: Indicate what was used as the datum point, and provide its elevation. It appears that you might have used the property corner stake adjacent to Viewland Way; however, the datum point must be a permanent object that won't move during construction and that the inspector can easily access with the height measurement equipment, such as a water q f meter or catch basin lid. Please label your datum point on the site plan and provide its elevation. % (3 ,; c�` iL 7-1 I)e,9 "c).(�OFd i�.� l�4 l " �ra��P al 16 sigarage 121)4C-I-tcFA4 � �� ����t � r, /t�bts��r✓ 3. Existing Garage: A detached aragp e was permitted on the subject site in 1995 lv / (BLD19950024). It is assumed that the existing garage is proposed for removal, however, ofil'.if�✓�.. PN..S _: 6/N4"114-�-7) please confirm whether or not this is the case. A demolition permit must be obtained from the Building Division prior to removal of the existing garage. The demolition permit may be combined with the subject permit application. Please contact a Permit Coordinator at (425) 771-0220 for additional information on demolition permit requirements. 4. Critical Areas: The existing critical areas determination on the subject site (File No. CRA19940126) was issued prior to a major critical areas code revision adopted in 2005. The r°. �subject site has been reassessed for the presence of critical areas on or adjacent to the site under % j P j /2, (5 7A 0401)the parameters of the current critical areas code, and it appears that the eastern side of the site contains and/or is adjacent to a slope that is steep enough to be considered a Landslide Hazard i.. Area pursuant to the requirements of ECDC 23.40 and 23.80. Due to the proposed garage's location within the minimum required buffer from the Landslide Hazard Area, a report by a qualified geotechnical en weer must be submitted addressingall applicable requirements of _ ECDC 23.40 and 23.80. In particular, the geotechnical engineer must address the proposed �� ���"' r✓�i�rt garage's compliance with the specific requirements related to alterations and design standards C 1 '(✓ applicable to development within a Landslide Hazard Area and/or its buffer, which are 6SCS )' L/f�,, contained within ECDC 20.80.070.A.2 and A.3. 5. Trees: Indicate any existing trees that are proposed for removal. Any proposed tree removal Pj must be consistent with the requirements of ECDC 18.45, 23.40, and 23.80. 6. Lot Coverage: Lot coverage is defined as the total ground coverage of all buildings or structures on a site measured from the outside of external walls or supporting members or from a point two and one-half feet in from the outside edge of a cantilevered roof, whichever covers the greatest area. The maximum allowed lot coverage for the RS -12 zone is 35 percent of the net lot area. Your site plan indicates a proposed lot coverage of 5,364 square feet (34%); however, it is difficult for staff to verify this number without more detailed lot coverage calculations due to the unique shape of the existing residence. Please provide more detailed lot coverage calculations including further documentation of the dimensions of the footprint of the existing residence and any other existing structures on site so that staff can verify compliance with the lot coverage requirements. Please submit three copies of your revised site plan (including one reduced copy) and two copies of any revised building plan sheets to a Development Services Permit Coordinator. Our office hours are Mondays, Tuesdays, Thursdays, and Fridays between 8:00 am and 4:30 pm, and Wednesdays between 8:00 am and noon. If you have any questions, feel free to contact me at (425) 771-0220. Sincerely, Development Services Department - Planning Division Jen Machuga, Associate Planner Enclosures: Handout #1357 E� 734 110 1. r 0 F m In Iv I Iv 18,0740 330,03, % r m III UI o� ® I i i t r Ani 'n E'DiMOINDS CITY PARK 21' 21, r Oa n . ..... Pit AV N0,11,00"im 22/.00'AVENUE—p—j— ol 9?.74 'P. 10, STORM 140,71, 2& ES"r 20 T. > µ001 To� -10 > zi . 0 N O'W 02' E % 4 1 . .. , L-- . 11 � /2299' ol 11 1 00 N OWN- E U, z 2 2W 0 0 r• Gl) m It Aw N —N < t-1-1 C, c -mia m 0 < F -- — — — — — — 2M:om z z m DQ T 0-1 —1 2 T 02 U) U) m co. ...... h -1 Z ts —4 2 no z 0 -2 No, > 4 4 m n fol 01 Zi -0 1? oN 0-0 E� 734 110 TRACT 100 CITY PARK In 18,0740 330,03, > m III N 0.56'00' w 7�Z 'n E'DiMOINDS CITY PARK E�