bld20131209_Ardsley_ENG2.pdf City of EdmondsBLD20131209 TH 121 5AVENUE NORTHEDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221 Website: www.ci.edmonds.wa.us PUBLIC WORK DEPARTMENT Planning • Building • Engineering Engineering Plan Review Comments PermitApplication:Date: #BLD20131209 June 18, 2014 rd Project Name/Address: Ardsley –7536–243Pl SW Contact Person/Address, Fax or E-mail: Reviewer: JENNIFERLAMBERTDivision: ENGINEERING During review of the subject submittal, it was found that the following information, corrections, or clarifications would need to be addressed. All Handouts referred to in these comments can be accessed at our website: www.ci.edmonds.wa.usunder City Government / Development Services Department / Engineering Division then scroll down to Handouts: st 1Review –12/26/13 nd 2Review –6/18/14 GENERAL 1)OK 2)6/18/14 –Comment was not addressed. Please reference the recording number (AFN 1560696) for the City Storm and Sewer Easement. 12/26/13 Comment: Please reference the recording number for the sewer/storm drainage easement. 3)6/18/14 –Comment was not addressed. Since the short plat has not been recorded, the following note could be added instead. “Road and utility easements will be dedicated upon recording of the short plat, PLN20080046.” 12/26/13 Comment: Please reference the recording number for the 14’ wideaccess & utility easement to benefit lot 6. ADDITIONAL COMMENT 4)6/18/14 –The connection of the tightlineto the stormwater stub was removed when the plans were revised. Please revise the plansto show the tightlineconnection to the stormwater stub. SEWER 1)OK DATE E-MAILED6/18/2014PAGE(1) City of EdmondsBLD20131209 TH 121 5AVENUE NORTHEDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221 Website: www.ci.edmonds.wa.us PUBLIC WORK DEPARTMENT Planning • Building • Engineering Engineering Plan Review Comments WATER 1)OK STORM 1)6/18/14 –Comment was not addressed. 12/26/13 Comment: Per the approved civil plans for the plat, the approved impervious surface amounts for lot 5is 2,400 sqft for structuresand 800 sqft for drivewaysnot to exceed 3200sqft (per drainage report, pg 3-9, dated 12/21/12).The plans submitted for the single family residenceshows an excess amount of impervious surface of 99 sqft. Please revise the plans to be consistent with the approved civils for the plat. 2)6/18/14 –Comment was partially addressed; however, the catchbasin that is placedto collect the surface water runoff from thedrivewaymust be placed such that the water runs off of the concrete/asphalt surface and not through any landscape areas. a.Please show concrete/asphalt around the catch basin. b.Please show the catch basin connected to the stormwater stub or wyed into the tightlineline near the stormwater stub. 12/26/13 Comment: Please show how the surface water runoff from the driveway will be collected. Please resubmit 3 copies of the revised plansand associated documents with a written response to each item to a Permit Coordinator. Please contact me at 425-771-0220ext 1321or by e-mail at jennifer.lambert@ci.edmonds.wa.usif you have specific questions regarding these plan corrections. DATE E-MAILED6/18/2014PAGE(2)