bld20131370_Goebel-1.docx City of Edmonds TH 121 5 AVENUE NORTH • EDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221 Website: www.ci.edmonds.wa.us PUBLIC WORKS DEPARTMENT Engineering Division Plan Review Corrections Plan Check : Date: # BLD20131369/70 January 3, 2014 Project Name/Address: Goebel New Single Family Residence 344 Sunset Ave N Contact Person/Address/Fax: Chris Pardo Design malboef@elementalarchitecture.com Reviewer: JoAnne ZulaufDivision:Engineering During review of the subject submittal, it was found that the following information, corrections, or clarifications would need to be addressed. All Handouts and Standard Details referred to in these comments can be accessed at our website: www.edmondswa.gov by choosing the Government tab and Public Works| Engineering under Departments: 1. Just a clarification: It is my understanding of this plan that no foundation/slab will be removed from the site and the new house will be constructed on the current existing foundation/slab without any additional foundation or slab added. If this is the case, the house area is considered “exempt”, not “exempt replaced” since no impervious surface will be removed and replaced. If new foundation/slab is replacing the existing in the same footprint or is larger than what is existing then these areas are considered “new”. Per Edmonds Community Development Code Section 18.30, “Replaced” only applies to driveways or sidewalks. Please make corrections to impervious surface calculations. 2. Call out width of sidewalk. 3. Add note to plan: An assessment of the condition of the existing curbing and sidewalk will be determined on site by the engineering inspector. Curb or Sidewalk in poor condition or damaged by construction activities shall require replacement. 4. Please delineate the property line so it can be identified easily. 5. Show water meter. Call out size of water meter and whether “existing” or “proposed”. A 1” meter may be necessary if fire sprinkling is required by the Fire Marshall. 6. Call out size, material and length of water service line. Please note if re-using existing line or installing a new line. For fire sprinkling requirements water line on property must be 1 ½” 7. Show 4”side sewer clean out at house connection and 6” clean out at property line. Clean out at property line is required to have a 12” locking cast iron lamphole cover. Please note on plans. Note if existing or proposed. 8. Please add both notes to plan: a. “If re-using existing side sewer (from property line to house): Property owner must have condition verified and provide a report to the Public Works Department.” DATE FAXED/E-MAILED 7/2/2017 PAGE ___ OF __ 13 b. “If re-using existing sewer lateral (from property line to City main): Condition must be verified by Public Works Department. Contact Edmond’s Sewer Division at 425-771- 0236.” 2. Footing drain is shown as running into the front yard. Is it connected to anything? Where does that go? 3. There are two lines shown around the house. One is identified as the footing drains. What is the other line? If not an additional line, please change line type and identify. Gutters should not be shown on this plan. 4. The front porch area is confusing on plans. Please clearly delineate the porch area, note if impervious or pervious. (If there are open slats and no gravel, asphalt or other impervious surface underneath the decking then it is considered pervious) Second floor deck should not be shown on this plan if within the building footprint. 5. Will concrete or asphalt in driveway be replaced? If so, please note on plans. This area will then belong under “exempt replaced” in the impervious surface calculation box. If the area will be untouched then that square footage should be listed under “exempt”. 6. Show catch basin protection in the right of way in front of or downstream from site. Add detail to plan (available on our webpage, see above). DATE FAXED/E-MAILED 7/2/2017 PAGE ___ OF __ 23 Please resubmit 3 copies of the revised plans/documents to a Development Services Coordinator. Please contact me at 425-771-0220 if you have specific questions regarding these plan corrections. DATE FAXED/E-MAILED 7/2/2017 PAGE ___ OF __ 33