April 10, 2014
Mr. Darrin Mock
H. Macke Construction LLC
Email: Darrin@hmacke.com
RE: PLAN REVIEW COMMENTSFOR PLANCHECK #BLD20140154
BARATTA/PEMBERTONADDITION AND REMODELLOCATED AT 655 MAPLE ST.
Dear Mr. Mock:
I have reviewed the above building permit applicationfor the Planning Division,and it was found that the
following information, corrections, or clarifications will need to be addressedbefore review can continue:
SitePlan:
1.Please make the following revisions/corrections to your site plan:
a.The elevation for Point D of the height rectangle is over the front porch, which makes it very
difficult to see the dimensions and location ofthe front porch. Please shift the label of Point D so
that it does not cover necessary information on the site plan.
b.Clearly indicate the outlines of the footprint of the upper floor where different than the outlines of
the footprintsof the main and lower floors on the site plan.
c.Label all features as existing or new in order to clearly indicate what changes to the site are
proposed under the subject permitapplication.
d.It appears that no changes are proposed to the existing rockeries; however, please label the rockeries
as existing and indicate if any modifications to the rockeries are proposed.
Setbacks:
2.The site plan indicates that the existing residence is 17.9 feet from the southern property line.
The RS-6 zone, however,requires a minimum street setback of 20 feet.According to Snohomish
County Assessor records, the existing residence was constructed in 1907, which was well before current
zoning regulations. Although the City’s code requirements related to nonconforming structures
contained inEdmonds Community Development Code (ECDC)17.40.020 allowsfor the maintenance of
an existing nonconforming structure, ECDC 17.40.020.F specifically states the following: “If a
nonconforming building or structure is destroyed or is damaged in an amount equal to 75 percent or
more of its replacement cost at the time of destruction, said building shall not be reconstructed except in
full conformance with the provisions of the Edmonds Community Development Code.”Additionally,
pursuant to ECDC 17.40.020.D, any alterations to a nonconforming building must comply with current
site development standards and must not expand any nonconforming aspect of the building.
Therefore, it must be shown that the proposal does not include destroying/damaging the existing
structure in an amount equal to 75 percent or more of its replacement cost and that all portions of the
addition (including the upper floor deck)comply with the currently required 20-foot street setbackas
measured from the southern property line. Additionally, the existing portion of the building that is being
retained may not bealtered in any way that expands the nonconformity. In order to ensure compliance
with the current site development standards of ECDC 16.20.030 as well as the nonconforming
regulations of ECDC 17.40.020, please conduct the following:
a.Provide sufficient documentation that the work proposed under the subject applicationdoes not
involve destroying/damaging the existing nonconforming structure in an amount equal to 75 percent
or more of its replacement cost.
b.Clarify on the site plan the locations of all existing and new portions of the structure. Clearly
indicate the shortest distances from all existing and new portions of the structure to all property
lines.
Page 1of 3
c.Indicate the location of the 20-foot street setback (as measured from the southern property line)on
the building plans, including the west and east elevation views (Sheets 1 and 2 respectively) as well
as all floor plans (Sheets 4, 5, and 6). Clearly indicate on all applicable building plan sheets which
portions of the structure are existing and which portions are new.All new portions of the structure
must be shown tocomply with current setback requirements.
Front Porch/Walkway:
3.Please respond to the following comments regarding the front porch and
walkway:
a.Your main floor plan (Sheet 5) indicatestheexisting porch in a different location than where it
would appear to be located based on the as-built main floor plan (Sheet 5A). Additionally, the
location of the porch shown on Sheet 5 is notconsistent with where the porch and walkway are
located on the site plan. Please revise all applicable plan building plan sheets and the site plan in
order to accurately indicate the locations of the existing porch and walkway and proposed porch and
walkway (if in a different location than existing).
b.As stated under Item #2 above, any new portions of the structure must comply with current setback
requirements. Although walkways are allowed within the minimum required setback area, the front
porch must comply with applicable setback requirements. Pursuant to ECDC 16.20.040.C,
“Uncovered and unenclosed porches, steps, patios, and decks may project into a required setback
not more than one-third of the required setback, or four feet, whichever is less; provided, that they
are no more than 30 inches above ground level at any point.”Since the existing front porch is
nonconforming, it cannot be expanded or relocated unless it is expanded/relocated in a way that
complies with current setbackrequirements.
c.When making the requested corrections to the proposal, please reviseimpervious surface
calculationsto reflect any changes to the locations of the front porch and walkway.Additionally, all
roof overhangs will be considered new impervious surface, so please also include the roof
overhangsin your revised impervious surface calculations. If you have any questions regarding
impervious surface calculations, please contact the Engineering Division.
Height Calculations:
4.Please respond to the following comments regarding the height calculations:
a.It appears that the intended datum point for the height calculations is a “concrete nail assumed
elevation 100.00’.” However, it is unclear where this nail is located. Additionally, the datum point
must be a permanent point that will not move during construction. If the concrete nail is a point that
can be moved, the datum point must be changed to a permanent pointsuch as the top of a fire
hydrant, water meter, catch basin, etc. Please clarify the location of the exact point utilized as the
datum for the height calculations and provide its elevation.
b.The average grade cannot be rounded up when conducting the height calculations. Therefore, based
on the elevations provided for Points A through D, the average grade is 88.975’ and the maximum
allowed height is 113.975’. Please correct this on thesite plan and building elevations.
Accessory Dwelling Unit:
5.Your lowerfloor plan indicates a living area, kitchen, bedroom, and
bathroom that could be accessed separately from the main portion of the residence. This meets the
definition of an Accessory Dwelling Unit (ADU) and requires separate land use review before staff can
approve the construction of an ADU within a residence. A land use application has been submitted
under File No. PLN20140005 for a conditional use permit in order to establish an ADU within this
space. As we discussed at the permit counter when you submitted the land use application, the City
cannot approve an ADU within the lower floor of the residence through the subject building permit
application unless a land use permit is first obtained. It is my understanding that you would like to
obtain the subject building permit application for the addition/remodel of the residence with the
condition that the lower floor will not be utilized as an ADU. If the requested land use permit is
approved, you would then apply for a second building permitin order to legalize the establishment of an
ADU within the residence. Going about the permitting in this way requires that the owners
acknowledge that they understand they will not obtain approval for an ADU through the subject building
permit application. As such, please have the property owner sign the enclosed ADU statement.
Page 2of 3
Please submit three copies of your revised site plan (including one reduced copy) and two copies of any
revised building plan sheets to a Development Services Permit Coordinator. Our office hours are Mondays,
Tuesdays, Thursdays, and Fridays between 8:00 am and 4:30 pm, and Wednesdays between 8:00 am and noon.
If you have any questions, feel freeto contact me at (425) 771-0220.
Sincerely,
Development Services Department -Planning Division
JenMachuga
Associate Planner
Page 3of 3
STATEMENTON ACCESSORY
DWELLING UNITS
DEVELOPMENT SERVICES DEPARTMENT
th
121 5Avenue N, Edmonds, WA 98020
Phone 425.771.0220 Fax 425.771.0221
Property Address(Street, City,State, Zip):Parcel #:
655 Maple St.00434209602100
Edmonds, WA 98020
I have read the requirements for Accessory Dwelling Units contained in Chapter 20.21 of the
Edmonds Community Development Code (ECDC) and understand that an Accessory Dwelling
Unit (ADU) as defined in ECDC Section 21.05.015 is prohibited until the required ADU
permit(s) are approved and any required inspections are finalized.
I also understand that an ADU permit cannot be approved unless all thecriteria in Chapter 20.21
are met, and all the necessary items are submitted, including an affidavit of occupancy and a
covenant to be filed with the Snohomish County regarding the regulations imposed on ADUs.
I am notrequesting to establish an Accessory Dwelling Unit on my propertyas part of the
subject building permit application (File No. BLD20140154), and I will obtain all applicable
ADU permits if I choose to establish an ADU in the futureprior to establishing such ADU. I
understand that the city’s review of the subject building permit application does not imply any
future approval of an ADU.