BLD20140919 Plan Review Comments.pdf CE ITY OF DMONDS th •1215AN•E,WA98020 VENUE ORTH DMONDS P: 425.771.0220 • F: 425.771.0221 • W:www.edmondswa.gov HONEAXEB DSD:P•E•B EVELOPMENT ERVICES EPARTMENTLANNING NGINEERING UILDING October 24, 2014 Mr. Kevin Mavis K&M’s Home Construction, LLC Email: kmavis@kandmhomes.com RE: PLAN REVIEW COMMENTSFOR PLANCHECK #BLD20140919 TH LINDGRENSINGLE-FAMILY RESIDENCELOCATED AT 17222 76AVE. W. Dear Mr. Mavis: I have reviewed the above building permit applicationfor the Planning Division,and it was found that the following information, corrections, or clarifications will need to be addressedbefore review can continue: Site Plan: 1.Please make the following corrections to your site plan: a.Indicate the fireplace bumpout on the southern side of the residence. b.Indicate the portion of the upper floor that cantilevers over the lower floor on the eastern side of the residence (where the bedroom extends over the den by one foot). c.Since the subject site contains a vehicular access easement, net lot area must be provided in addition to the gross lot area.Net area is the gross (total) area excluding the area of any vehicular access easements. Please indicate both the gross and net areas on the site plan. d.The site plan is difficult to follow due to the use of the same line styles throughout. Please utilize varied linestyles to help avoid confusion. For example, the property lines and the footprint of the residence could be made a bold line style in order to help distinguishthese lines from the dimension lines. e.Provide three large-format copies of your revised site plan and one reduced-format(8.5”x11”or 8.5”x14”) copy. Height Calculations: 2.Please respond to the following comments regarding the height calculations: a.Your plans indicate that a “tack”was utilized as the site benchmark. Please provide further description of where this tack is located. The datum pointfor the height calculationsmust be a permanent point that will not move during construction, such as the top of a fire hydrant, water meter lid, catch basin, etc. b.When calculating the average grade, the numbers cannot be rounded up. Please revise the average grade and maximum allowed heightas indicated on the site plan and building elevations accordingly. c.Indicate the elevation of the proposedheight on the site plan. Lot Coverage: 3.Lot coverage is defined as the total ground coverageof all buildings or structures on a site measured from the outside of external walls or supporting membersexcluding a maximum of 30” of eaves. The maximum allowed lot coverage for the RS-12zone is 35 percent of the net lot area. Thank you for providing lot coverage calculations on the site plan. Please revise the calculations, however, to ensure that all portions of the structure are included (excluding up to 30” of eaves). Thus, the portion of the upper floor bedroom that cantilevers over the lower floor den must be included in the lot coverage calculations. Additionally, the lot coverage must be stated in total square feet as well as calculated as a percentageof the netlot area. Page 1of 2 Critical Areas Report: 4.Thank you for providing a “Resident Fish Presence/Absence Survey Report”by Wetland Resources, Inc. and dated July 28, 2014.Please address the following comments regarding this report: a.Thereport referencesParcel No. 27040700402100. This parcel, however, is located approximately 400 feet south of the subject site. It appears there may have been a typo in the parcel number stated in the report, but this cannot be confirmed since a vicinity map was not provided with the report. The report must conclusively determine the stream type wherethe stream flows adjacent to the subject site. Thus, the stream type must be determined along th Parcel No. 27040700401100 (addressed 1721876Ave. W)and Parcel No. 27040700400900 th (addressed 17228 76Ave. W).Please have Wetland Resources, Inc. either provide an updated report addressing the stream type along theseneighboring parcelsor provide a letter confirming that there was an error inthe parcel number indicated within the report and referencingthe correct addressesand parcel numbersof the location where the stream was assessed. Additionally, with the addendum, please have Wetland Resources, Inc. provide a vicinity map indicating the locationofthe stream that was assessed. b.Additional information must be provided inorder for staff to determine compliance with the minimum required streambuffer and critical area building setback. Please revise your site plan to clearly indicate the location of the existing stream on the adjacent properties to the south and west of the subject site. Additionally, please indicate the minimum required 50-foot buffer (as required for Type Np streams and measured from the ordinary high water mark pursuant to ECDC 23.90.040.D.1) and 15-foot critical areas building setback(as required from all critical areas buffers pursuant to ECDC 23.40.280). c.If necessary, the location of the proposed residence must be revised in order to comply with the minimum required critical areasbuffer and building setback. Please submit three copies of your revised site plan (includingone reduced copy) and two copies of any revised building plan sheets to a Development Services Permit Coordinator. Our office hours are Mondays, Tuesdays, Thursdays, and Fridays between 8:00am and 4:30pm, and Wednesdays between 8:00am and noon.If you have any questions, feel freeto contact me at (425) 771-0220. Sincerely, Development Services Department -Planning Division JenMachuga Associate Planner Page 2of 2