Loading...
BLD20141014 Plan Review Comments - 2nd Review.pdf CE ITY OF DMONDS th •1215AN•E,WA98020 VENUE ORTH DMONDS P: 425.771.0220 • F: 425.771.0221 • W:www.edmondswa.gov HONEAXEB DSD:P•E•B EVELOPMENT ERVICES EPARTMENTLANNING NGINEERING UILDING January 20, 2015 Ms. Brandi Neal Pacific Ridge Homes Email: bneal@pacificridgehomes.com ND RE: 2PLAN REVIEW COMMENTSFOR PLANCHECK #BLD20141014 TH PACIFIC RIDGE HOMESSINGLE-FAMILY RESIDENCEAT 22303-95PL. W Dear Ms. Neal: I have reviewed your resubmittal dated January 7, 2015 for the above building permit applicationfor the Planning Division,and it was found that the following information, corrections, or clarifications will need to be addressedbefore review can continue(comments from my letter dated November 20, 2014 are included for referencewith all new comments provided in italics). Please provide a cover letter addressing how each of the following comments havebeen addressed with your next resubmittal. Plan Discrepancy: 1.Addressed. Site Plan: 2.Please make the following corrections to your site plan: a.Addressed. b.Addressed. c.11/20/14 Comment: Correct the width of the eaves on the site plan to be consistent with the width indicated on the building plans. Impervious surface calculations must accurately reflect the width of the eaves. 1/20/15 Comment: The eaves are shown on the site plan as being 1-foot eaves around the entire residence; however, based on the building plans, it appears that certain sectionsof the eaves will be 18 inches. Please correct the width of the eaves on the site plan in order to be consistent with the building plans, andrevise the impervious surface calculations to include the eaves. d.11/20/14 Comment: Indicate topography lines at two-foot intervals. 1/20/15 Comment: This comment was notaddressed. Please provide two-foot contours on the site plan and indicate the elevations of each contour. These contours shouldbe consistent with what was shown on the associated subdivision documents (File No. PLN20120046) and are utilized to verify the height calculations. e.Addressed. f.1/20/15 Comment(New Comment): The “fireplace cantilever”is indicated on the site plan, but is shown as being optional on the building plans. Please confirm whether or not the “fireplace cantilever”is proposedbecause this impacts the locationof the height rectangleas well asthe lot coverage and impervious surface calculations. Setbacks: 3.Addressed. Height Calculations: 4.Please respond to the following comments regarding the height calculations: a.Addressed. Page 1of 3 b.11/20/14 Comment:The height rectangle must enclose the entire structure excluding up to 30 inches of eaves, so any bumpouts on the building must be included in the height rectangle. When making revisions to the layout and/or location of the residence as necessary to address the setbacks comments above, please keep in mind that the location of the height rectangle may need to be adjusted to reflect the revised location/layout of the residence. Please revise the height rectangleandupdate the elevations of Points A through D accordingly. 1/20/15 Comment: Since the “fireplace cantilever”is more than just a chimney(i.e. it includes indoor space such as bookshelves), it must be included in the height rectangle. Point D was shifted to the east to encompassthe “fireplace cantilever,”but Point B also needs to be shifted to the east to encompassitin the height rectangle.As discussed above, it must be confirmed whether or not the “fireplace cantilever”is proposed so that staff can verify that the height rectangle is properly located. c.11/20/14 Comment: Upon making any adjustmentsto the elevations of Points A through D, please update the height calculations accordingly, keeping in mind that the numbers cannot be rounded up when making these calculations. The elevations of the corrected average original grade, maximum allowed height, and proposed height must be indicated on the siteplan and building elevations. 1/20/15 Comment: Although the position of the proposed residence was shifted with the resubmittal, the elevations of Points A through D were not changed. Please verify that the elevations of Points A through D are updated as necessary to reflect their newlocations.If any corrections are necessary to the elevations of Points A through D, please revise the height calculations accordingly. d.11/20/14 Comment: Indicate the elevation of the proposed height on the building elevation views. 1/20/15 Comment: This comment was not addressed. Please indicate the elevation of the proposed height (in respect to the datum point) on the building plans. Additionally, if the elevations of the average original grade and maximum allowed height changein response to the above comments,please be sure to update the building elevationviewsto indicate the elevations ofthe corrected average original grade, maximum allowed height, and proposed height. e.11/20/14 Comment: Refer to Handout # B41 (enclosed) for additional information on height calculations. Lot Coverage: 5.11/20/14 Comment: Lot coverage is defined as the total ground coverage of all buildings or structures on a site measured from the outside of external walls or supporting members excluding a maximum of 30” of eaves. The maximum allowed lot coverage for the RS-8zone is 35 percent of the net lot area. Thank you for providing lot coverage calculations on your site plan; however, it appears that the entire footprint of the residence was not included in your calculations. After making any necessary revisions to the layout of the proposed residence to address the comments related to setbacks above, please correct the lot coverage calculations, making sure that the entire footprint of the residence is included (excluding up to 30 inches of eaves).The lot coverage must be calculated as a percentage of the net lot area, which is 8,004 square feet according to the subdivision that created the lot. 1/20/15 Comment: This comment was not addressed. Please ensure that the entire footprintof the proposed residence is included in the lot coverage calculations (including the “fireplace cantilever”), excluding up to 30 inches of eaves. The rear patio should not be included in the lot coverage calculations since it is uncovered; however, the rear patio will need to be included in the impervious surface calculations. Page 2of 3 Impervious Surface Calculations: 6.11/20/14 Comment: It was noted that the same areasof the house and covered porch are provided within the lot coverage calculations as within the impervious surface calculations. Although up to 30 inches of eaves may be excluded from the lot coverage calculations, all eaves and other impervious surfaces must be included in the impervious surface calculations. Please make allnecessary correctionsto your plans. Any questions related to the impervious surface calculations may be directed to Jennifer Lambert, Engineering Technician, at (425) 771-0220 or Jennifer.Lambert@edmondswa.gov. 1/20/15 Comment: This comment wasnot addressed. Please revise the impervious surface calculations to accurately reflect the proposaland to includeall eaves. Please submit a cover letter stating how each of the above comments have been addressed as well as three copies of your revised site plan (includingone reduced copy) and two copies of any revised building plan sheets to a Development Services Permit Coordinator. Our office hours are Mondays, Tuesdays, Thursdays, and Fridays between 8:00am and 4:30pm, and Wednesdays between 8:00am and noon. If you have any questions, feel freeto contact me at (425) 771-0220or Jen.Machuga@edmondswa.gov. Sincerely, Development Services Department -Planning Division JenMachuga Associate Planner Page 3of 3