bld20141073_Kong-1.docx City of Edmonds TH 121 5 AVENUE NORTH • EDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221 Website: www.ci.edmonds.wa.us PUBLIC WORKS DEPARTMENT Engineering Division Plan Review Corrections Plan Check : Date: # BLD20141073 November 26, 2014 th Project Name/Address: New Carport 23422 76 Ave W Contact Person/Address/Fax: Kritsadang Kongsom Boot Kongsomboot@hotmail.com Reviewer: JoAnne ZulaufDivision:Engineering During review of the subject submittal, it was found that the following information, corrections, or clarifications would need to be addressed. All Handouts and Standard Details referred to in these comments can be accessed at our website: www.edmondswa.gov by choosing the Permit Assistance and Handouts by #. Scroll down to find Engineering Handouts. Plan 1: Site Plan: 1. Please show new driveway and new driveway cut and all other changes to the property that are not shown on this plan. 2. Per Edmonds Community Development Code Section 18.30.060, any new development or redevelopment with more than 2,000 square feet of new impervious surfacing shall be required to provide storm water mitigation. New impervious surface is the roofline of a structure, concrete or pavement areas that have been constructed or proposed for construction after 1977. a. Please provide a breakdown of all impervious surface (see example below) on the site and the year each was constructed. b. If the total of the impervious surface constructed after 1977 is 2000sf or over, stormwater management is required. Please see Handout E72, E72A and E72B (on our website-see above) for stormwater management methods and requirements. Example: Square footage Year constructed. House roofline 1922 sf 1968 Driveway 354 sf 1968 Concrete Porch 140 sf 1972 Addition 920 sf 1976 Garage 600 sf 1983 Addition 40 sf 1983 Driveway 240 sf 1983 Carport 780 sf 2005 nd 2 Driveway 1000 sf 2012 Highlighted is all construction after 1977. This is considered “new” impervious surface. The total is 2660 sf so it is over the threshold of 2000sf. Stormwater management would be required in this example. Please resubmit 3 copies of the revised plans/documents to a Development Services Coordinator. Please contact me at 425-771-0220 if you have specific questions regarding these plan corrections. DATE FAXED/E-MAILED 7/2/2017 PAGE ___ OF __ 11