BLD20141121_Select_Homes_ENG1.pdf City of EdmondsBLD20141101 TH 121 5AVENUE NORTHEDMONDS, WA 98020 • (425) 771-0220 FAX (425) 771-0221 Website: www.ci.edmonds.wa.us PUBLIC WORK DEPARTMENT Planning • Building • Engineering Engineering Plan Review Comments PermitApplication:Date: #BLD20141101December 4, 2014 nd Project Name/Address: Select Homes –8411 202St SW Contact Person/Address, Fax or E-mail: KAYLA.CLARK@OUTLOOK.COM Reviewer: JENNIFERLAMBERTDivision: ENGINEERING During review of the subject submittal, it was found that the following information, corrections, or clarifications would need to be addressed. All Handouts referred to in these comments can be accessed at ourwebsite: www.edmondswa.govunder City Government / Development Services Department / Engineering Division then scroll down to Handouts: GENERAL 1)Please revise the plan sheet ‘BLDG Permit # 2014______’ to ‘BLDGpermit # BLD20141101’. 2)Since this property is only one lot at this time and a short plat has not been approved, please remove all lines/referencesfor future connections. a.Please keep in mind that during construction the City will not be able to approve the installation of the storm line for the future connections unless the short plat civils have been approved and issued. 3)A 10’ Joint Utility Easement is shown on the plans. Please reference the recording number on the plans. If this a future easement, please remove the easement from the plans. 4)As changes are made to each sheet, please make sure that all sheets are consistent. 5)On page H-3 of the ‘Storm Drainage Report’, please revise the owner responsibility to include the outfall pipe from the detention to the City system. SITE DEVELOPMENT PLOT PLAN(pg.1 of 4) GENERAL 1)Please add a note to the plans that state the existing utilities will be removed and/or capped under the demolition permit(BLD20141102). 2)Please label what type of material will be used for the driveway. DATE E-MAILED12/4/2014PAGE (1) City of EdmondsBLD20141101 TH 121 5AVENUE NORTHEDMONDS, WA 98020 • (425) 771-0220 FAX (425) 771-0221 Website: www.ci.edmonds.wa.us PUBLIC WORK DEPARTMENT Planning • Building • Engineering Engineering Plan Review Comments WATER 1)It appears that a fire sprinkler system is required for this property. The existing water service line from the watermain to the meter is not the appropriate size and a new tap will be required. a.Please show the new line from the watermain to thehouse. b.Please show theback of thewater meter located at the property line(where the water meter is within the right-of-way). c.Please add a note that a 1” meter is to be installed. d.Please label the water service line as1 ½” and note the pipe material and tracer wire. SEWER 1)Please label the connection at the main as an romac inserta tee. 2)Please label the pipe material and sizeon the portion of sewer located on private property. The sewer lateral must be 6”from the sewer main to the property line. Once on private property the sewer may reduce to 4”. STORM 1)FYI…the City does not require 6” PVC for footing drains or tightline. 4” may be used. Revise plans as needed. GENERAL NOTES AND LEGEND(pg.2 of 4) GENERAL NOTES 3)Note #1 –revise “2012WSDOT/APWA standard…” to state “2014 WSDOT/APWA standard…” DATE E-MAILED12/4/2014PAGE (2) City of EdmondsBLD20141101 TH 121 5AVENUE NORTHEDMONDS, WA 98020 • (425) 771-0220 FAX (425) 771-0221 Website: www.ci.edmonds.wa.us PUBLIC WORK DEPARTMENT Planning • Building • Engineering Engineering Plan Review Comments GRADING & TESC PLAN(pg.3 of 4) GENERAL 1)Please add a note that a silt fence shall be added as needed per Edmonds Standard Detail E1.1. CONSTRUCTION SEQUENCE 1)Please note that a pre-construction meeting is not required for new single family residences. You may schedule one if you choose to. DRAINAGE AND DETAILS (pg. 4 of 4) No comments. Please resubmit 3 copies of the revised plansand associated documents with a written response to each item to a PermitCoordinator. Please contact me at 425-771-0220ext 1321or by e-mail at jennifer.lambert@ci.edmonds.wa.usif you have specific questions regarding these plan corrections. DATE E-MAILED12/4/2014PAGE (3)