Loading...
BLD20150072 Plan Review Comments.pdf CE ITY OF DMONDS th •1215AN•E,WA98020 VENUE ORTH DMONDS P: 425.771.0220 • F: 425.771.0221 • W:www.edmondswa.gov HONEAXEB DSD:P•E•B EVELOPMENT ERVICES EPARTMENTLANNING NGINEERING UILDING February 18, 2015 Mr. Matthew Stewart Email: matthewstewart@comcast.net RE: PLAN REVIEW COMMENTSFOR PLANCHECK #BLD20150072 TH STEWART ADDITIONAT 8532 236ST. SW Dear Mr. Stewart: I have reviewed the above building permit applicationfor the Planning Division,and it was found that the following information, corrections, or clarifications will need to be addressedbefore review can continue: Site Plan: 1.Please make the following corrections to your site plan: a.Indicate the existing deck and stairs on the northern side of the house. b.Please clarify the structures/surfaces located between the existing house and garage. It is unclear which portions of this area is paved walkway,stairs,deck, etc.It may help by shading in the portions that are paved walkwaysorother impervious surfaces. Setbacks: 2.Please respond to the following comments related to the minimum required setbacks for the RS-8 zone: a.Please indicate the shortest distances from the proposed addition to all property lines in order to ensure compliance with setback requirements. Minimum required setbacks to the proposed addition are as follows: StreetSetbacks= 25’measured from the northern and eastern property lines Side Setbacks = 7.5’measured from the southern and western property lines b.Pursuant to ECDC 16.20.040.B, eaves and chimneys may project into a required setback not more than 30 inches.Please indicate the eaves on the proposed addition to ensure compliance with setback requirements. Height Calculations: 3.Please respond to the following comments regarding the height calculations: a.The height rectangle must enclose the entire residenceexcluding up to 30 inches of eaves. It appears that the eaves may have been included in your height rectangle, and Point A does not form a rectangle with the other points. Please correctthe locations of Points A through D, so that they form a rectangle that encompasses the entire residence excluding up to 30 inches of eaves. When revising the location of the height rectangle, please be sure to update the elevations of Points A through D as necessary to reflect their revised locations. b.Upon making any adjustmentsto the elevations of Points A through D, please update the height calculations accordingly, keeping in mind that the numbers cannot be rounded up when making these calculations.Itwas noted that there was a slight error in the math when calculating the average grade and maximum allowed height. Please verify all calculations and make any necessary corrections. You may use decimal places instead of inches if it is easier. The elevations of the corrected average original grade, maximum allowed height, and proposed height must be indicated on the site plan and building elevations. c.Refer to Handout # B41 (enclosed) for additional information on height calculations. Page 1of 2 Lot Coverage: 4.Lot coverage is defined as the total ground coverage of all buildings or structures on a site measured from the outside of external walls or supporting membersexcluding a maximum of 30” of eaves. The maximum allowed lot coverage for the RS-8zone is 35 percent of the net lot area. Thank you for providing lot coverage calculations on your site plan; however, it appears that some impervious surfaces may have been mistakenly included in the total lot coverage.Lot coverage calculations must be provided separately from the impervious surface calculations. Additionally, although up to 30”of eaves may be excluded from the lot coverage calculations, all eaves must be included in the impervious surfacecalculations. Please provide a breakdown of the lot coverage calculations including the footprints of all existing and proposed structures (excluding up to 30”of eaves), including the footprint of the residence, proposed addition, existing garage, both sheds, and any other existing structures including any stairs or decks that are covered and/or that exceed 30”in height above ground level. Impervious Surface Calculations: 5.It appearsthat the same areasof the house, addition, garage, and shedswere included within the lot coverage calculations as within the impervious surface calculations. Although up to 30 inches of eaves may be excluded from the lot coverage calculations, all eaves and other impervious surfaces must be included in the impervious surface calculations. Please make allnecessary correctionsto your plans. Any questions related to the impervious surface calculations may be directed to Chris Rivera, Engineering Technician, at (425) 771-0220, or Chris.Rivera@edmondswa.gov. Please submita cover letter addressing how eachof the aboveitemshavebeen addressed as well asthree copies of your revised site plan (includingone reduced copy) and two copies of any revised building plan sheets to a Development Services Permit Coordinator. Our office hours are Mondays, Tuesdays, Thursdays, and Fridays between 8:00am and 4:30pm, and Wednesdays between 8:00am and noon.If you have any questions, feel freeto contact me at (425) 771-0220or Jen.Machuga@edmondswa.gov. Sincerely, Development Services Department -Planning Division JenMachuga Associate Planner Page 2of 2