Loading...
BLD20150224_Neuman_ENG1.pdf City of EdmondsBLD20150224 TH 121 5AVENUE NORTHEDMONDS, WA 98020 • (425) 771-0220 FAX (425) 771-0221 Website: www.ci.edmonds.wa.us PUBLIC WORK DEPARTMENT Planning • Building • Engineering Engineering Plan Review Comments PermitApplication:Date: #BLD20150224April 9, 2015 Project Name/Address: Neuman –390 Sunset Ave N Contact Person/Address, Fax or E-mail: Steve Barnes–sbarnes@cornerstonearch.com Reviewer: JENNIFERLAMBERTDivision: ENGINEERING During review of the subject submittal, it was found that the following information, corrections, or clarifications would need to be addressed. All Handouts referred to in these comments can be accessed at our website: www.edmondswa.govunder City Government / Development Services Department / Engineering Division then scroll down to Handouts: SITE PLAN 1)If the utilitiesare shown on the site plan, please show all the utilities(i.e. storm and power, gas, cable, etc.). 2)Please note on theplans if the drivewaycurb cut is existing or new/widened. a.If the curb cut is new/widenedplease show the 2’asphalt cut located where the curb/gutter is to be replaced. 3)As changes are made to other plan sheets, please revise this sheet as needed. TEMPORARY EROSION CONTROL PLAN(C1 of 2) Notes 1)It appears that the ‘Engineer’s Grading Specifications’ are related to the soil preparation for the structure and does not pertain to the grading of the site. Please remove these notes and place on the buildings foundation plan if needed. DATE E-MAILED4/10/2015PAGE (1) City of EdmondsBLD20150224 TH 121 5AVENUE NORTHEDMONDS, WA 98020 • (425) 771-0220 FAX (425) 771-0221 Website: www.ci.edmonds.wa.us PUBLIC WORK DEPARTMENT Planning • Building • Engineering Engineering Plan Review Comments DRAINAGE PLAN (C2 of 2) General 1)Please revise the title ‘Drainage Plan’ to ‘Drainage and Utility Plan’. 2)Please show all the utilities on this plan (water, sewer, storm, gas, phone, power, etc.) 3)Please add a note to theplans that state the existing utilities will be removed and/or capped under the demolition permit(BLD20150223). 4)Remove note #3 in the ‘Storm Drainage Notes’. 5)Remove note #6in the ‘Storm Drainage Notes’. WATER 1)It appears that a fire sprinkler system is required for this property.Typically if there is an existing water service line from the watermain to the meter it will not be the appropriate size and a new tap will be required. a.Please show the water meter located within the landscape strip. b.Please add a note that a 1” meter is to be installed. c.Please label the pipe material and tracer wire. SEWER 1)Please show the sewer from the main to the house on this plan sheet. There are three sewer lines located within Sunset. You will need to connect to the sewer furthest east (the line closest to the subject site) on Sunset. 2)Please note if the sewer lateral is proposed or existing. If the existing side sewer and lateral is proposed to be reused, the sewer will need to be inspected by the City’s Public Works department to determine if it can be reused. Contact Edmonds sewer division, 425-771-0235. If the lateral is a new connection, please label the connection at the main as a romac inserta tee. 3)Please label the pipe material and size. The sewer lateral (from the main to the property line) must be 6”. Once on private property the sewer may reduce to 4”. DATE E-MAILED4/10/2015PAGE (2) City of EdmondsBLD20150224 TH 121 5AVENUE NORTHEDMONDS, WA 98020 • (425) 771-0220 FAX (425) 771-0221 Website: www.ci.edmonds.wa.us PUBLIC WORK DEPARTMENT Planning • Building • Engineering Engineering Plan Review Comments 4)Show a 6” cleanout at the property line. Please add a note that the 6” cleanout at the property line will have a 12” cast iron lamphole cover with ½” hexbolts. 5)Show a cleanout located within 2’ of the house, at any 90° bend, when there is less than 3’ between two 45° bends, and when there is more than 100’ between cleanouts. 6)Please show the invert elevations at the main and the house so that slope and coverage can be verified. If the slope of the pipe exceeds 20% the pipe will need to be anchored. STORM 1)The proposed stormwater plan shows connection to a manhole that is sump (no connection to the City System). The stormwater runoff from the subject site cannot connect to this manhole. Please show connection to the City system or maintain all stormwater runoff onsite through low impact development. a.If connection to the system on Sunset Ave is proposed, the storm main will need to extendto the subject site. Please note there are significant utilities located within Sunset Ave. Locates should be called when designing the extension. i.Depending on the location of the stormmain extension, a grind and overlay couldbe required. nd b.If connection to the system on 2Ave is proposed, an easement between the private property owners will need to be provided to the City prior to approval of the stormwater management system. c.Another option is to provide plans showing discharging the stormwater onto BNSF right-of-way. For the City to approve this, we would need to see an approvedpermit from BNSF permitting what is proposed. 2)The stormwater management system proposed is to direct discharge to the City system. Please provide a quantitative downstream analysis to show that the existing infrastructure can support the additional water. A similar analysis was completed for development at620 Sunset Ave. Please feel freevisit the developmentservices departmentto review those documents. The downstream analysis should include calculations to support the resolution. 3)The surface water runoff from the driveway shall not sheet flow into the street. Please show how the surface water runoff from the driveway will be collected and dischargedto the storm system. 4)Please provide rim and invert elevations for all pipeswithin the catch basins. DATE E-MAILED4/10/2015PAGE (3) City of EdmondsBLD20150224 TH 121 5AVENUE NORTHEDMONDS, WA 98020 • (425) 771-0220 FAX (425) 771-0221 Website: www.ci.edmonds.wa.us PUBLIC WORK DEPARTMENT Planning • Building • Engineering Engineering Plan Review Comments DRY UTILITIES 1)Please show all proposed dry utilities(gas, phone, cable, etc.)on the plans so that utility separation can be verified. Please resubmit 3 copies of the revised plansand associated documents with a written response to each item to a Permit Coordinator. Please contact me at 425-771-0220ext 1321or by e-mail at jennifer.lambert@edmondswa.govif you have specific questions regarding these plan corrections. DATE E-MAILED4/10/2015PAGE (4)