BLD20150239_Kemper_ENG2.pdf City of EdmondsBLD20150239 TH 121 5AVENUE NORTHEDMONDS, WA 98020 • (425) 771-0220 FAX (425) 771-0221 Website: www.ci.edmonds.wa.us PUBLIC WORK DEPARTMENT Planning • Building • Engineering Engineering Plan Review Comments PermitApplication:Date: #BLD20150239December 7, 2015 Project Name/Address: Kemper –9303 Olympic View Dr Contact Person/Address, Fax or E-mail: Keith Kemper –kkemps@comcast.net Reviewer: JENNIFERLAMBERTDivision: ENGINEERING During review of the subject submittal, it was found that the following information, corrections, or clarifications would need to be addressed. All Handouts referred to in these comments can be accessed at our website: www.edmondswa.govunder City Government / Development Services Department / Engineering Division then scroll down to Handouts: st 1Review –4/24/15 nd 2Review –12/7/15 GENERAL 1) 4/24/15 Comment -There are too many plans on the submitted plan sheets that address the same information throughout each plan. Please revise the Plan sheets as stated below. OK a. OK b. OK c. OK d. OK e. f.Due to the amount of plans submittedand the overlap of information on the three sheets the comments below will attempt to capture all changes; however, there may be additional comments nd after the 2submittal not addressed in this submittal. 2)12/7/15 –New Comment –Please label the private access and utility easement. 3)12/7/15–New Comment –Please make sure that theSite Plan and the Civil Plans are consistent. Label theretaining walls, rockeries, etc on both plan sheets. DATE E-MAILED12/7/2015PAGE (1) City of EdmondsBLD20150239 TH 121 5AVENUE NORTHEDMONDS, WA 98020 • (425) 771-0220 FAX (425) 771-0221 Website: www.ci.edmonds.wa.us PUBLIC WORK DEPARTMENT Planning • Building • Engineering Engineering Plan Review Comments TEMPORARY EROSION CONTROL PLAN–Now called GRADING AND TESC PLAN 1)OK 2)OK 3)OK 4)OK WATER 1)12/7/15 –Comment was partially addressed. It appears that there are two pipe sizes called out for the water service line. Please revise the plans to make sure that all items below have been addressed. 4/24/15 Comment -It appears that a fire sprinkler system is required for this property.Typically if there is an existing water service line from the watermain to the meter it will not be the appropriate size and a new tap will be required. a.Please show the water service line from the meter to the house. b.Please add a note that a 1” meter is to be installed. c.Please show a 1-1/2” line to be installed (as required for a combination fire and domestic service line). d.Please label the pipe material andnotetracer wireto be installed on the water service line. e.There must be a minimum of 3’ separation between the dry utilities (power, gas, cable, etc.) and the water main. Please revise the plans accordingly. 2)12/7/15 –Current location is approved; however, since themeter needs to be upsized due to the requirement for a fire sprinkler system, therewill be a new tap on the main. a.The current and new water service line from themain to the meter comes or will come into the east side of the meter. Please revise your plans to show the water service from the meter to the house leaving the meter on the west side. DATE E-MAILED12/7/2015PAGE (2) City of EdmondsBLD20150239 TH 121 5AVENUE NORTHEDMONDS, WA 98020 • (425) 771-0220 FAX (425) 771-0221 Website: www.ci.edmonds.wa.us PUBLIC WORK DEPARTMENT Planning • Building • Engineering Engineering Plan Review Comments b.Please add a note to the plans that the location of the new meter to be coordinated withthe City’s Water Department at 425-771-0235. 4/24/15 Comment -Confirmation on where the water meter can be located is currently being reviewed by the City’s Water Department. Commentswill follow addressing this issue. 3)12/7/15 –New Comment –The water service line is showing as being replaced within the asphalt of the private drive. Please show/notethe following,“Contractor to complete final restoration on all trench patches for utilities installed with this development.” SEWER 1)OK 2)OK 3)OK 4)12/7/15 –Comment partially addressed.The lamphole cover note was not added. 4/24/15Comment -Show a 6” cleanout at the edge of easement (located within the easement). Please add a note that the 6” cleanout at theedge of easementwill have a 12” cast iron lamphole cover with ½” hexbolts. 5)OK 6)12/7/15 –Comment was not addressed. 4/24/15 Comment -Please show the invert elevations at the main and the house so that slope and coverage can be verified. If the slope of the pipe exceeds 20% the pipe will need to be anchored. STORM 1)12/7/15 –Comment wasaddressed; however, footing drains,sump pumps, retaining wall and rockery drainage, typically do not discharge to the onsite stormwater managementsystem unless the system is designed to account for theadditional water. a.Please revise thedrainage report to address the addition of the footingdrains,sump pump, retaining wall and rockery drainageto the proposed system. DATE E-MAILED12/7/2015PAGE (3) City of EdmondsBLD20150239 TH 121 5AVENUE NORTHEDMONDS, WA 98020 • (425) 771-0220 FAX (425) 771-0221 Website: www.ci.edmonds.wa.us PUBLIC WORK DEPARTMENT Planning • Building • Engineering Engineering Plan Review Comments b.Orthe footing drains,sump pump, retaining wall rockery drainagemaydischarge to a separatesystem (i.e. drywell). If you choose this option, please provide a memo from the Geotechnical engineer of record approving the location of the drywell. 4/24/15 Comment -Show where the footing drains will discharge to. 2)4/24/15 –Comment was not addressed. It appears that there is a retaining wall along thewest patio. Please show where the drainage for both the retainingwall and rockery willdischarge to. Please refer to note one above. 4/24/15 Comment -Show where the retaining wall drainage will discharge to. 3)12/7/15 –Comment (a) was not addressed. 4/24/15 Comment -Per the plat (S98-082) this lot has a detention system that was installed and designed to collect 5000 sqft of impervious surface water. If you have 5000 sqft or less you may directly discharge to this system without an additional detention system. To discharge to this system, please provide the following. a.Please submit a report that verifies that the existing system is functioning properly. b.If the amount of impervious area exceeds 5000 sqft, a flow control system will need to be installed to account for the additional impervious area.This configuration will need tobe evaluated by a licensed engineer to show that the downstream system (not owned by the City) is not adversely impacted. 4)OK 5)12/7/15 –Comment was not addressed. 4/24/15 Comment -Please provide rim and invert elevations for all pipes within the catch basins. NEW COMMENTS 6)12/7/15 –Please show how the runoff from the drivewaywill discharge to the catch basin (i.e. directional flow arrows, etc.). 7)12/7/15 –Note the catch basin in the driveway as a Type I. 8)12/7/15 -Add an observation well to the infiltration system. DATE E-MAILED12/7/2015PAGE (4) City of EdmondsBLD20150239 TH 121 5AVENUE NORTHEDMONDS, WA 98020 • (425) 771-0220 FAX (425) 771-0221 Website: www.ci.edmonds.wa.us PUBLIC WORK DEPARTMENT Planning • Building • Engineering Engineering Plan Review Comments 9)12/7/15 –Showthe pipe connecting to the infiltration at the north end (not at the middle of the pipe). 10)12/7/15 –The force line from the sump pump needs to connect to a catch basin. Please revise accordingly. DRY UTILITIES 1)12/7/15 –Comment was addressed; however, the 3’separation applies to stormas well. This was not originally put in the comment since there was no conflict with storm at that time. Please address accordingly. 4/24/15 Comment -Please showaminimum of 3’ separation between the sewer/water andallthedry utilities(gas, phone, cable, etc.). Please resubmit 3 copies of the revised plansand associated documents with a written response to each item to a Permit Coordinator. Please contactme at 425-771-0220ext 1321or by e-mail at jennifer.lambert@edmondswa.govif you have specific questions regarding these plan corrections. DATE E-MAILED12/7/2015PAGE (5)