Plan Review Corrections
Plan Check : Date:
# BLD20150473 July 6, 2015
th
Project Name/Address:
Select Homes New Single Family Residence 8729 218 St SW
Contact Person/Address/Fax:
Kayla Clark kayla.clark@outlook.com
Reviewer: JoAnne ZulaufDivision:Engineering
During review of the subject submittal, it was found that the following information, corrections, or
clarifications would need to be addressed. All Handouts and Standard Details referred to in these
comments can be accessed at our website: www.edmondswa.gov by choosing the Government tab and
Public Works| Engineering under Departments:
Review comments #3
Review comments #2
Site Plan SP-01:
1. Done.
2. Done.
3. Revised detention sizing acceptable per Jerry Shuster, Stormwater Engineer.
4. Done.
5. Done.
6. Done.
7. 7/6/15 Please review the Engineering Division Policy “Procedures for Obtaining Permitting
and Approval for Tree Removal or Trimming within City ROW”. The Shoffner Consulting
Report dated June 16, 2015 fails to provide the necessary criteria for removal of Tree #2.
Proposed construction does not qualify as a condition that meets the necessary criteria.
Please revise utility plan to avoid removal of the tree or provide additional information showing
the necessary criteria can be met for removal. The report also fails to meet section 5 of the
policy. A replanting and replacement plan is required as a condition for permit approval under
the tree removal policy. Please show location of replanting on plan sheet including driplines
and add specific information regarding how the plan meets the policy requirements. 6/17/15
th
The tree on 218 farther to the west side of the property appears to be only 5 or so feet from
the location of the proposed detention system. The trench to install the pipe will be another
foot or so closer. ECDC 18.45.050 Land Clearing and Tree Cutting Code: Application
requirements Section H.1. states;
DATE FAXED/E-MAILED 7/2/2017 PAGE ___ OF __
13
“The applicant may not fill, excavate, stack or store any equipment, or compact the earth in any way within the
area defined by the drip line of any tree to be retained.”
Please show the dripline of the tree on the plans and the distance between the dripline and the
trench excavation area for the detention system. Show trees to be retained on the site.
8. Done.
General Notes GN-01: - Done
Grading and TESC Plan TP-01:
9. 6/17/15 On plan show tree protection around trees at dripline. Show existing trees on plan.
Indicate those to be removed and show tree protection measures for those that will be
retained.
10. Done.
Genera Details Plan TD-01: -Done
DATE FAXED/E-MAILED 7/2/2017 PAGE ___ OF __
23
Please resubmit 3 copies of the revised plans/documents to a Development Services Coordinator. Please
contact me at 425-771-0220 if you have specific questions regarding these plan corrections.