Loading...
bld20150473_Select-3.docx City of Edmonds TH 121 5 AVENUE NORTH • EDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221 Website: www.ci.edmonds.wa.us PUBLIC WORKS DEPARTMENT Engineering Division Plan Review Corrections Plan Check : Date: # BLD20150473 July 6, 2015 th Project Name/Address: Select Homes New Single Family Residence 8729 218 St SW Contact Person/Address/Fax: Kayla Clark kayla.clark@outlook.com Reviewer: JoAnne ZulaufDivision:Engineering During review of the subject submittal, it was found that the following information, corrections, or clarifications would need to be addressed. All Handouts and Standard Details referred to in these comments can be accessed at our website: www.edmondswa.gov by choosing the Government tab and Public Works| Engineering under Departments: Review comments #3 Review comments #2 Site Plan SP-01: 1. Done. 2. Done. 3. Revised detention sizing acceptable per Jerry Shuster, Stormwater Engineer. 4. Done. 5. Done. 6. Done. 7. 7/6/15 Please review the Engineering Division Policy “Procedures for Obtaining Permitting and Approval for Tree Removal or Trimming within City ROW”. The Shoffner Consulting Report dated June 16, 2015 fails to provide the necessary criteria for removal of Tree #2. Proposed construction does not qualify as a condition that meets the necessary criteria. Please revise utility plan to avoid removal of the tree or provide additional information showing the necessary criteria can be met for removal. The report also fails to meet section 5 of the policy. A replanting and replacement plan is required as a condition for permit approval under the tree removal policy. Please show location of replanting on plan sheet including driplines and add specific information regarding how the plan meets the policy requirements. 6/17/15 th The tree on 218 farther to the west side of the property appears to be only 5 or so feet from the location of the proposed detention system. The trench to install the pipe will be another foot or so closer. ECDC 18.45.050 Land Clearing and Tree Cutting Code: Application requirements Section H.1. states; DATE FAXED/E-MAILED 7/2/2017 PAGE ___ OF __ 13 “The applicant may not fill, excavate, stack or store any equipment, or compact the earth in any way within the area defined by the drip line of any tree to be retained.” Please show the dripline of the tree on the plans and the distance between the dripline and the trench excavation area for the detention system. Show trees to be retained on the site. 8. Done. General Notes GN-01: - Done Grading and TESC Plan TP-01: 9. 6/17/15 On plan show tree protection around trees at dripline. Show existing trees on plan. Indicate those to be removed and show tree protection measures for those that will be retained. 10. Done. Genera Details Plan TD-01: -Done DATE FAXED/E-MAILED 7/2/2017 PAGE ___ OF __ 23 Please resubmit 3 copies of the revised plans/documents to a Development Services Coordinator. Please contact me at 425-771-0220 if you have specific questions regarding these plan corrections. DATE FAXED/E-MAILED 7/2/2017 PAGE ___ OF __ 33