Loading...
BLD20150811 Plan Review Comments.pdf CE ITY OF DMONDS th •1215AN•E,WA98020 VENUE ORTH DMONDS P: 425.771.0220 • F: 425.771.0221 • W:www.edmondswa.gov HONEAXEB DSD:P•E•B EVELOPMENT ERVICES EPARTMENTLANNING NGINEERING UILDING July 21, 2015 Mr. John Wolfe Email: stableplatform@gmail.com RE: PLAN REVIEW COMMENTSFOR PLANCHECK #BLD20150811 TH ST. SW MATHEWSDECK AT 7920-209 Dear Mr. Wolfe: I have reviewed the above building permit applicationfor the Planning Division,and it was found that the following information, corrections, or clarifications will need to be addressedbefore review can continue: Setbacks: 1.Pursuant to Edmonds Community Development Code (ECDC) 16.20.040.C, “uncovered and unenclosed porches, steps, patios, and decks may project into a required setback not more than one-third of the required setback, or four feet, whichever is less; provided, that they are no more than 30 inches above ground level at any point.”Your site plan indicates that the portion of the proposed deck and stairs that extend four feet into the street setback are less than 30”in height; however, they must also be unenclosed (i.e. cannot have a guardrail). Please revise the plans to either eliminate the guardrail onthe portionsof the deck and stairs that extend into the street setback, or reduce the size of the stairs and deck so that they entirely comply with the 25-foot street setback. Lot Coverage: 2.Lot coverage is defined as the total ground coverage of all buildings or structures on a site measured from the outside of external walls or supporting membersexcluding a maximum of 30” of eaves. The maximum allowed lot coverage for the RS-8zone is 35 percent of the net lot area. If the proposed stairs and deck exceed30” in heightor if the stairs and deckareless than 30”in height but havea guardrailcausing the overall height to exceed 30”,theymust be included in the lot coverage calculations for the site. It appears that the portion that is less than 30”in height and enclosed by the guardrail, however, was not included in the lot coverage calculations. Please revise the lot coverage calculationsas necessary to meet the above definition, making sureto includethe footprints of the existing residence (excluding up to 30” of eaves, but including all upper floor cantilevers), covered front porch, all portions of the proposed stairs and deckthat exceed 30”in height and/or that includea guardrail,and any other existing or proposed structures. Site Plan: 3.When making the above requested corrections to your site plan, please conduct the following: a.Correct the label of the street to 209thSt. SW. b.Indicate the covered front porch. Wetland: 4.As indicated on the site plan, a wetland is located on the adjacent property to the southeast of the subject site. In order to determine compliance with the minimum required bufferfrom the wetland, a critical areas report prepared by a qualified professional addressingthe applicable requirements of ECDC Chapters 23.40 and 23.50must be submitted.Any work proposed on the site must be consistent with the applicable critical areas regulations. Thus, the location of the proposed deck and stairsmay be limited depending on the category of the wetland and itsminimum required buffer. Please submitthree copies of your revised site plan and two copies of any revised building plan sheets to a Development Services Permit Coordinator. Our office hours are Mondays, Tuesdays, Thursdays, and Fridays between 8:00am and 4:30pm. Please note that the Permit Center is closed on Wednesdays.If you have any questions, feel freeto contact me at (425) 771-0220or Jen.Machuga@edmondswa.gov. Sincerely, Development Services Department -Planning Division JenMachuga Associate Planner Page 1of 1