BLD2015-1454 Factory Tires.pdf MEMORANDUM Date: November 19, 2015 To: Nash Alibhai, fdnash@1cloud.com From: Fire Marshal John J. Westfall 425.771.0213 th Subject:BLD 2015-1454 Garage 22617 76 Ave W #108 th BLD2015-1455 Carport 22617 76 Ave W #108 These reviews are conducted in accordance with 2012 IFC and Edmonds Community Development Code. A complete review cannot be completed without the following information and new information provided may require additional clarification and/or requirements for final approval. Site Plan: 1. Call out construction type for EXISTING BUILDING. 2. Call out occupancy type(s) in EXISTING BUILDING. 3. Show all interior and exterior openings in warehouse, including those to COVERED STAIR/BALCONY space. 4. Provide wall assembly information and identify any opening protectives to interior and exterior openings. Garage 5. You indicate this is an S-2 occupancy type. Will automobile repair garage functions be performed in this structure? 6. If all out on plans the what activities those are and the level of repairs performed (e.g. tire/parts exchange, fluids exchange, welding/hot work, grinding, spray- finishing,. Carport 7. The proximity of the carport to the EXISTING BUILDING provides for an increase in the fire area to EXISTING BUILDING. Your calculations indicate EXISTING building as 12,020 s.f. Depending upon the occupancy type and function, an automatic fire sprinkler system could be required over 12,000 given the increase of fire area due to carport. a. Where installed, automatic fire sprinkler requires permit and city approvals. b. Also where installed, a fire alarm permit is also required for notification and monitoring of your sprinkler system. City of Edmonds Office of Fire Marshal 8. Carport is indicated as a U occupancy type, defined as a carport and accessory to the primary function of the building (IBC 406.3). What functions will be performed in the carport? Call out on plans what those activities are. a. New carport area is 1560 s.f. An occupancy type U cannot exceed 1000 s.f. Reduce the size of the accessory carport or reclassify the occupancy to the appropriate type with regard to the function of the structure, OR b. Type U occupancy may be increased to a maximum of 3,000 s.f. where used only for the storage of private or pleasure-type motor vehicles with no repair or fueling function, AND opening protectives are designed and installed to separate this area from the rest of the EXISTING BUILDING. If this is the case, call out these limitations and design corrections to your plans. (IBC 406.3.2) 9. Provide fire extinguishers. th 10. Fire access from 76 Ave W is restricted by parallel parking stalls near office building. Provide 20 wide land to a vertical height of 136 and restripe fire lane. 11. Depending upon applicant responses, additional information may initiate new comments and new requirements provided. Please correct plans and resubmit. Cc: Building Plans Examiner Chuck Miller 2