bld20151484-Thuesen SFR - E1.pdf CITY OF EDMONDS PLAN REVIEW COMMENTS ENGINEERING DIVISION (425) 771-0220 City Website: www.edmondswa.gov DATE:January 26, 2016 TO:Eric Thuesen Thuesen Custom Homes ericthuesen@frontier.com FROM:Jeanie McConnell, Engineering Program Manager jeanie.mcconnell@edmondswa.gov RE:Application #: bld20151484 Project: Single Family Residence th Project Address: 510–8AveN During review of the above noted application, it was found that the following information, corrections,or clarifications are needed. Please redline plans or submit three (3) sets of revised plans/documents as appropriate with a written response to each of the items below to a permit coordinator. nd Resubmittals can be made at the Development Services Department on the 2floor of City Hall. Permit Center hours are M, T, Th & F from 8am-4:30pm. The Permit Center is closed on Wednesdays. City of Edmonds handouts, standard details and development code can be referenced on the City website. 1)A CB has been shown in the driveway, but RIM and invert elevations have not been provided. Please reviseto include this information. 2)It appears as though the driveway will be constructed with an inverted crown, but there also appears to be a flow arrow pointing to the south from the CB in thedriveway. Please provide a cross section of thedriveway to show how flows will be directed to theCB, show curb along driveway edges, etc. as needed. 3)Plans indicate installation of a CB at thenorthwest corner of thesite. Clearly note this CB will th be connecting to an existing storm pipe that crosses 8AveN. In addition, provide RIM and invert elevations for all pipe connections. 4)Will footing drains be installed with theproposed SFR construction? If so, show their point of connection to the CB at the northwest corner of the property. 5)The plans indicate a “constructed drainage swale”along the north property line. Please provide additional information with regards to this swale, including: a.Detailfor theswale with side slopes b.Top and bottom of swale spot elevations c.Outlet to new CB at northwest corner. How will the flows dischargeto this CB? 6)On the west side of the proposed garage there appears to be a sewer line and sewer stub shown. However, there is also a sewer line shown coming from thesouthwest corner of thehouse, with connection to stub near the cleanout at thewest end of theaccess road. Please correct plans to show only one sanitary side sewer line. Provide invert elevations at thestub and at thehouseso a minimum 2% pipe slope can be confirmed. 7)Clearly note which portions of thesewer were installed with the short plat (grey line type and add note) and which portions will be constructed under the subject SFR permit.Note pipe material and pipe size. 8)Clearly label water meters serving lots 1 and 2. The civil plan sheet provided with theSFR submittal shows two water meters together at the north edge of theaccess/utility easement, which is not consistent with how they are shown on thesite plan. 9)Indicate size of water meter and water service line to be installed.Please note on plans that a residential fire sprinkler is not required. 10)Show location of all utilities within the access & utility easements, including catch basins.Line type should be greyed out to represent existing utilities versus proposed. 11)Indicate all required erosion control measureson the plans, including rockconstruction entrance, catch basin protection, etc.and reference City standard details. 12)Show proposed topography contours, if changes are proposed. How will the slope behind the proposed garage be managed? 13)Revise Impervious Lot Coverage to just say Impervious Surface Area. The City does not have an imperviouscoverage threshold. As the garageis a separate structure than the house, please list the garage separately. Page 2of 2