Loading...
BLD20160179 Plan Review Comments.pdf CE ITY OF DMONDS th •1215AN•E,WA98020 VENUE ORTH DMONDS P: 425.771.0220 • F: 425.771.0221 • W:www.edmondswa.gov HONEAXEB DSD:P•E•B EVELOPMENT ERVICES EPARTMENTLANNING NGINEERING UILDING March 24, 2016 Mr. Robin Kearsley Kearsley Homes Inc. Email: r@kearsleyhomes.com RE: PLAN REVIEW COMMENTSFOR PLANCHECK #BLD20160179 THERRELL ADDITION/REMODELLOCATED AT 8609 TALBOT RD. Dear Mr. Kearsley: I have reviewed the above building permit application for the Planning Division, and it was found that the following information, corrections, or clarifications will need to be addressed before review can continue: Site Plan: 1.Please respond to the following comments regarding your site plan . a.Your site plan states a scale of 1” = 20’; however, it was not printed at such a scale, so staff is unable to verify certain distances and dimensions. Please reprint your site plan so that it is accurately to a scale of 1” = 20’. b.Based on the elevation views, it appears that a portion of the upper floor cantilevers over the lower floor. Please indicate all cantilevers on the site plan. c.Label the front porch as being covered. Elevation View: 2.Provide an elevation view of the proposed deck on the northern side ofthe residence. Setbacks: 3.Pleaserespond to the following comments regarding the minimum required setbacks: a.Pursuant to ECDC 16.20.040.B, “eaves and chimneys may project into a required setback not more than 30 inches.”The building plans indicate 4-foot eaves around the entire residence; however, no more than 30 inches of eaves may project into the minimum required setbacks. Therefore, the location of the proposed garage will need to be shiftedand/or the width of the eaves will need to be reduced in order to comply with setback requirements. Additionally, since the eastern side of the residence does not currently comply with the minimum required 10-foot side setback, the eaves on this portion of the house cannot be expanded beyond what is existing. b.The proposed garage must comply with the minimum required 10-foot side setback from the western property line. Since the western property line is not parallel with the western wall of the proposed garage, please indicate the shortest distance from the southwestern corner of the garage to the western property line. Height Calculations: 4.Please respond to the following comments regarding the height calculations: a.Your site plan indicates a datum point of 100’, but it does not indicate what was used as the datum point. Please indicate what was used as the datum point keeping in mind that this must be a stationary point that will not move during construction, such as a water meter, catch basin, manhole cover, etc. b.Pursuant to ECDC 21.40.030.B, the height rectangle utilized for conducting the height calculations must be “the smallest rectangle which will enclose all of the building, excluding a maximum of 30 inches of eaves.” Your plans indicate 4-foot eaves. Thus, the height rectangle will need to be modified in location in order to only exclude 30 inches of the eaves. Please revise the location of the height rectangle and update the elevations of Points A through D accordingly. Page 1of 2 c.The elevation of Point B appears to be inconsistent with the topography lines. Pleasecorrect the elevation of Point B and/or the topography linesas necessary to accurately reflect the original grade at this location. d.After the elevationsof PointsAthrough D are updated as discussed above, the average original grade and maximum allowed height will need to be re-calculated, keeping in mind that the numbers utilized for the height calculations cannot be rounded up. e.If any changes are made to the average original grade, maximum allowed height, and/or proposed height in response to the above comments, please be sure to not only update these numbers on the site plan, but also as shown on the building elevation views. Lot Coverage: 5.Lot coverage is defined as the total ground coverage ofall buildings or structures on a site measured from the outside of external walls or supporting members excluding a maximum of 30” of eaves. Since the eaves are proposed to be larger than 30”, the portion of the eaves in excess of 30” must be included in the lot coverage calculations. The lot coverage calculations must also include the portion of the upper floor that cantilevers over the lower floor, the proposed deck, covered front porch, etc. Please provide a breakdown of the lot coverage calculations in order to confirm that all necessary elements have been included in the calculations. In addition to providing the proposed lot coverage in square feet, please also calculate it as a percentage of the lot area. The maximum allowed lot coverage within the RS-20 zone is 35% of the lot area. Landslide Hazard Area: 6.Please respond to the following comments related to the Landslide Hazard Area: a.The subject site contains and is adjacent to a slope that is steep enough to be considered both a Landslide Hazard Area and Erosion Hazard Area as defined within ECDC Chapters 23.40 and 23.80. Pursuant to ECDC 23.80.070.A.1, the minimum required buffer as measured from the top of the slope is equivalent to 50 feet or the height of the slope, whichever is greater. A 15-foot critical areas setback is required in addition to this buffer. Since improvements are proposed within the minimum required buffer and critical areas building setback, a report prepared by a qualified geotechnical engineer must be submitted. The geotechnical engineer must review all proposed improvements including the new deck and stairsand any modifications to be made to the exterior of the site within the minimum required buffer and building setback. The report must address all applicable requirements of ECDC Chapters 23.40 and 23.80, including but notlimited to Sections 23.80.060 and 23.80.070. b.Indicate the shortest distance from the top of the Landslide Hazard Area to the proposed improvements. Please submit three copies of your revised site plan (including one reduced copy) and two copies of any revised building plan sheets to a Development Services Permit Coordinator. Our office hours are Mondays, Tuesdays, Thursdays, and Fridays between 8:00am and 4:30pm, and Wednesdays between 8:30am and noon. . If you have any questions, feel freeto contact me at (425) 771-0220or Jen.Machuga@edmondswa.gov Sincerely, Development Services Department -Planning Division JenMachuga Associate Planner Page 2of 2