bld20160332-0333 Westgate Elementary Portables - E1.pdf
CITY OF EDMONDS
CIVIL PLAN REVIEW COMMENTS
ENGINEERING DIVISION
(425) 771-0220
City Website: www.edmondswa.gov
DATE:
May 5, 2016
TO:
Matt Finch, Edmonds School District
finchm@edmonds.wednet.edu
FROM:
JeanieMcConnell, Engineering Program Manager
jeanie.mcconnell@edmondswa.gov
RE:
Application #: bld20160332 and bld20160333
Project: Westgate Elementary
th
Project Address: 9601 220St SW
During review of the above noted application, it was found that the following information,
corrections, or clarifications are needed. Reviews by other divisions, such as Planning, Building, or
Fire may result in additional comments. Please redline plans or submit three (3) sets of revised
plans/documents with a written response to each of the items below to a permit coordinator.
nd
Resubmittals can be made at the Development Services Department on the 2floor of City Hall.
Permit Center hours are M, T, Th & F from 8am-4:30pm and on Wednesdays from 8:30am-noon.
City of Edmonds handouts, standard details and development code can be referenced on the City
website.
1.The detention system control structure manhole has an invert elevation of 379.71. The existing
storm drain CB upstream of CB#3 indicatesinvert elevations at 379.75. As proposed, should
the main line system backup it will flow into the proposed detention system. Please revise
plans accordingly.
2.In theIntroduction to the Stormwater Site plan prepared by AHBL and dated March 2016, it is
noted that the subjectproject will meetthe Minor Site Project requirements. The project site
classification is later correctly noted as a Category 1 small site. Please revise the Introduction to
correctly state the project classification, or alternatively I could redline this change.