BLD20160348_Sanger_ENG1.pdf City of EdmondsBLD20160348 TH 121 5AVENUE NORTHEDMONDS, WA 98020 • (425) 771-0220 FAX (425) 771-0221 Website: www.edmondswa.gov PUBLIC WORK DEPARTMENT Planning • Building • Engineering Engineering Plan Review Comments PermitApplication:Date: #BLD20160348June 7, 2016 Project Name/Address: Sanger –711 Main St Contact Person/Address, Fax or E-mail: Tom Leren –tom@lerendesign.com Reviewer: JENNIFERLAMBERTDivision: ENGINEERING During review of the subject submittal, it was found that the following information, corrections, or clarifications would need to be addressed. All Handouts referred to in these comments can be accessed at our website: www.edmondswa.govunder City Government / Development Services Department / Engineering Division then scroll down to Handouts: SITE PLAN 1)As changes are being made to the plan sheets, please make sure all plans (i.e. Site Plan, Civils, Architecturals) are revised to be consistent with the changes. SITE DEVELOPMENT PLAN (SHEET 1 OF 4) GENERAL 1)Change ‘BLDG Permit #_______’ to ‘BLD Permit # BLD20160348’(make this change to all plan sheets). 2)Please provide a haul route (this comment is specific to this application due to the location of the site). 3)Please provide a traffic control plan (this comment is specific to this application due to the location of the site). 4)Add a note that if the sidewalk does not meet ADA standards, the sidewalk will need to be replaced. SEWER 1)The side sewer cannot be approved until an easement is in place that allows for the private sewer line to cross through the west property. Please provide a copy of the recorded sewer easement. DATE E-MAILED6/8/2016PAGE (1) City of EdmondsBLD20160348 TH 121 5AVENUE NORTHEDMONDS, WA 98020 • (425) 771-0220 FAX (425) 771-0221 Website: www.edmondswa.gov PUBLIC WORK DEPARTMENT Planning • Building • Engineering Engineering Plan Review Comments WATER 1)The new1”water service line has been installed (from the main to the meter) and is located at the southwest corner of the subject site. Please revise the plans to reflect this. STORM Per Leif Helleren, the stormwater management system is changing from the proposed detention system to an infiltration system. Therefore, a review on the proposedstormwater management system was not completed at thistime. 1)Provide infiltration rates per handout #E72D, the City of Edmonds Code, and Appendix C in the Stormwater Supplement.Make sure that the infiltration testsare taken at the depth that the infiltration and drywells will be placed. 2)Make sure the Geotechnical Engineer addresses in his reportthe stability of the slope in relation to theinfiltration. 3)Provide a cross section detail of the infiltration system and driveway. There must be a minimum of 2’of cover over pipes under drivable surfaces. There must be a minimum of 1’of cover over the infiltration trench. 4)Show an observation well on the infiltration system. 5)All connections to an infiltration system shall connect to a catch basin and then discharge to the infiltration system. This is to allow for settlement of debris prior to stormwater discharging to the infiltration system. 6)Show all runoff from the driveway discharging to the stormwater management system. 7)Show the overflow path of the infiltration system. 8)Show where the footing drains will discharge to for the home and retaining walls. If the footing drains will discharge to a drywell, make sure that the Geotechnical Engineer addresses the location and the impacts it will or won’t have on the slope. 9)Update the storm drainage notes as needed. There may be additional comments once theproposed stormwater systemhasbeen submitted. DATE E-MAILED6/8/2016PAGE (2) City of EdmondsBLD20160348 TH 121 5AVENUE NORTHEDMONDS, WA 98020 • (425) 771-0220 FAX (425) 771-0221 Website: www.edmondswa.gov PUBLIC WORK DEPARTMENT Planning • Building • Engineering Engineering Plan Review Comments DRY UTILITIES 1)Please show all proposed dry utilities (gas, phone, cable, etc.) on the plans so that utility separation can be verified. There should be a minimum of 3’ horizontal separation from the dry utilitiesand the wet utilities (water, sewer, and storm). GENERAL NOTES AND LEGEND (SHEET 2 OF 4) 1)Note 1: Change ‘2014 WSDOT/APWA…’ to ‘2016 WSDOT/APWA’. 2)Remove any details that are no longer necessary. CLEARING, GRADING, & TESC PLAN (SHEET 3 OF 4) 1)If it is not shown, please show all neighboring structures and trees to the subject site. This is to verify that proper precautions are being taken to ensure no damage or approval of removal is obtained for structures or trees on sites adjacent to the construction. 2)Revise theword ‘nay’to ‘May’in note 2 under the TESC Notes. GENERAL DETAILS (SHEET 4 OF 4) No Comments Please resubmit 3 copies of the revised plansand associated documents with a written response to each item to a Permit Coordinator. Please contact me at 425-771-0220ext 1321or by e-mail at jennifer.lambert@edmondswa.govif you have specific questions regarding these plan corrections. DATE E-MAILED6/8/2016PAGE (3)