bld20160545_Schroeder - Grading&Driveway 11.8.16.pdf City of EdmondsBLD20160545 TH 121 5AVENUE NORTHEDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221 Website: www.edmondswa.gov/ PUBLIC WORK DEPARTMENT Planning • Building • Engineering Plan Review Comments PermitApplication:Date: #BLD20160545November 8, 2016 Schroeder -Grading& Driveway1142 Vista Pl. Project Name/Address: Steve SchroederSchroeder.steven@frontier.com Contact Person/Address, Fax or E-mail: Reviewer: Chris RiveraDivision: ENGINEERING During review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Reviews by other divisions, such as Planning, Building, or Fire may result in additional comments. Please redline plans or submit three (3) sets of revised plans/documents with a written response to each of the items below to a permit coordinator. nd Resubmittals can be made at the Development Services Department on the 2floor of City Hall. Permit Center hours are M, T, Th & F from 8am-4:30pm and on Wednesdays from 8:30am-noon. City of Edmonds handouts, standard details and development code can be referenced on the City website. www.edmondswa.gov/ Comments 1 -June 30, 2016 Comments 2 -November 8, 2016 1)ok 2)ok 3)ok 4)ok 5)ok 6)ok 7)6/30/2016 comment -Per city code, to be considered pervious surfaces the slope of the asphalt surface shall not exceed 5%.Per city handout E72B, the subgrade of the proposed paved driveway (a Category 2 Small Site Project see Handout E-72) shall not exceed 2% slope in order to meet 100% infiltration or shall not exceed 5% slope to meet 84% infiltration (the remaining 16% will need to be mitigated by another method). Subgrade beyond 5% slope does not meet city requirements and will be perceived as impervious. a.6/30/2016 comment -If the driveway cannot meet the minimum slope, storm water runoff will need to be collected from new impervious surfaces and directed to a new storm water management system or modified existing system. DATE E-MAILED11/8/2016PAGE(1) City of EdmondsBLD20160545 TH 121 5AVENUE NORTHEDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221 Website: www.edmondswa.gov/ PUBLIC WORK DEPARTMENT Planning • Building • Engineering Plan Review Comments 1.6/30/2016 comment -If a new stormwater management system is added or the existing system is modified, provide design information on the storm management system and show the system on the site plan. Show the system, surface slopes, storm conveyance pipesand catch basin (and their invert elevations). November 8, 2016 –A new stormwatermanagement system has been proposed. Due to the flow path for the outfall, a geotechnical engineer will need to provide us with a stormwater drainage plan. Once received the proposal will need tobe reviewed by the city’s stormwater engineer. b.N/A 8)ok November 8, 2016 –Consistent with Edmonds Community Development Code 18.80.060, 9) driveway slopes shall not exceed 14% slope. Please indicate this requirement on the plans. November 8, 2016–An asphalt berm or asphalt thickened edge will need to be placed along the 10) inner circle of the driveway in order to direct stormwater toward the stormwater management system. Please update the site plan showing the berm/thickened edge and revise the cross section. November 8, 2016 –Elevations at the beginning of the driveway(section running east/west near 11) existing paved road) appear to have slope such that stormwater will flow west or northwest. Please address the stormwater flows providing elevations on the site plan and section views that will show water flow to the stormwater managementsystem. November 8, 2016 –With a proposed detention line of 73’, the proposed does not meet the city’s 12) detention sizing of 74’ (impervious surface area of 3,500 sf). The system willbe received as having capability to retain 3,000 sf of impervious surfaces. November 8, 2016 –Per Edmonds Community Development Code 18.40.020,no rockery shall 13) support asurcharge. Rockeris are allowed along cut slopes with no surcharge. The rockery south of the proposed detention system will need to be a retaining wall designed by anengineer. Please provideasection cut as well as topand bottom elevations on the site plan. Please resubmit 3 copies of the revised plansand associated documents with a written response to each item to a Permit Coordinator. Please contactme at 425-771-0220ext 1339or by e-mail at chris.rivera@edmondswa.govif you have specific questions regarding these plan corrections. DATE E-MAILED11/8/2016PAGE(2)