Loading...
bld20160545_Schroeder - Grading&Driveway.pdf City of EdmondsBLD20160545 TH 121 5AVENUE NORTHEDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221 Website: www.edmondswa.gov/ PUBLIC WORK DEPARTMENT Planning • Building • Engineering Plan Review Comments PermitApplication:Date: #BLD20160545June30, 2016 Schroeder -Grading& Driveway1142 Vista Pl. Project Name/Address: Steve SchroederSchroeder.steven@frontier.com Contact Person/Address, Fax or E-mail: Reviewer: Chris RiveraDivision: ENGINEERING During review of the subject submittal, it was found that the following information, corrections, or clarifications would need to be addressed. All Handouts referred to in these comments can be accessed at our website: www.edmondswa.gov/under City Government / Development Services Department / Engineering Division then scroll down to Handouts: 1)Please add a note that filter socks will be addedto private catch basins and yard drains. 2)Please show on the site plan locationsfor stock piles if any. 3)Please add a note that all disturbed soils will be compost amended. 4)Please show on the site plan the year of construction forallexisting impervious surfaces (gravel areas, driveways, walkwaysand roof outline)and indicate current management through existing storm detention system. 5)There is an existing detention system providing stormwater mitigation for the existing home. Please clearly identify the detention system on the site plan and clearly show that new impervious surface runoff will not flow toward the existing detention system. 6)Please show and provide on the site plan square footage for allexisting and proposed impervious surfaces. Please provide the table from the Site Classification Worksheet from Handout E-72 pg.5 on your site plan. 7)Per city code, to be considered pervious surfaces the slope of the asphalt surfaceshall not exceed 5%. Per city handout E72B, the subgrade of the proposed paved driveway (a Category 2 Small Site Project see Handout E-72) shall not exceed 2% slope in order to meet 100% infiltration or shall not exceed 5% slope to meet 84% infiltration (the remaining 16% will need to be mitigated by another method). Subgrade beyond 5% slope does not meet city requirements and will be perceived as impervious. a.If the driveway cannot meet the minimum slope, storm water runoff will need to be collected from new impervious surfaces and directed to a new storm water management system or modified existing system. 1.If a new stormwater management system is added or the existing system is modified, provide design information on the storm management system and show the system DATE E-MAILED6/30/2016PAGE(1) City of EdmondsBLD20160545 TH 121 5AVENUE NORTHEDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221 Website: www.edmondswa.gov/ PUBLIC WORK DEPARTMENT Planning • Building • Engineering Plan Review Comments on the site plan. Show the system, surface slopes, storm conveyance pipesand catch basin (and their invert elevations). b.If permeable pavement is used, please identify on the site plan the base and choker course materials to be used. 8)Please provide information identifying which lots, if any, have rights to the10’access/utility easement along the north property line and to what capacity. a.Structures such as retaining walls/rockerys are not permitted over property lines without an appropriate easement from the adjacent property. b.Other lotsthat have rights to the 10’ wide ingress/egress easement will need to forfeittheirrights of use prior to the construction of any structure. Please resubmit 3 copies of the revised plansand associated documents with a written response to each item to a Permit Coordinator. Please contact me at 425-771-0220ext 1339or by e-mail at chris.rivera@edmondswa.govif you have specific questions regarding these plan corrections. DATE E-MAILED6/30/2016PAGE(2)