bld2016-0561-0562-0563-Willowdale-E2.pdf CITY OF EDMONDS CIVIL PLAN REVIEW COMMENTS ENGINEERING DIVISION (425) 771-0220 City Website: www.edmondswa.gov DATE: August 18, 2016 TO: Wayne Nelson, Pacific Ridge Homes WANelsen@drhorton.com FROM: Jeanie McConnell, Engineering Program Manager jeanie.mcconnell@edmondswa.gov RE: Application #: bld20160561-0562-0563 Project: Willowdale Townhomes th Project Address: 20730, 20732, 20736 –76Ave W During review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Reviews by other divisions, such as Planning, Building, or Fire may result in additional comments. Pleasesubmit three (3) sets of revised plans/documents with a written response to each of the items below to a permit coordinator. nd Resubmittals can be made at the Development Services Department on the 2floor of City Hall. Permit Center hours are M, T, Th & F from 8am-4:30pm and on Wednesdays from 8:30am-noon. City of Edmonds handouts, standard details and development code can be referenced on the City website. Review 1 –June 29, 2016 Review 2 –August 18, 2016 ok 1. August 18, 2016 –Response letter states “Site development shall be per previously 2. reviewed and approved plans, copies of which have been included for reference”. However, not all of therequested information is shown on these plan sheets. Please provide a utility plan that clearly shows all new utility connectionsand information indicated below. The existingcivil plan sheets are useful inshowingthe overall utility systemsand should be a reference document only. 6/29/2016 comment -Submit a utility plan clearly indicating allexisting and proposed utilities and required utility separation. Dry utilitiesshall also be shown. Indicate meter size, pipe size, depth and invert elevations to confirm new connections to existing systems will meet minimum slope requirements. ok 3. August 18, 2016 –A dashed line for footing drain and tightline has been added to the site 4. plan, however, connection to the detention system is not shown.This information should be provided on theutility plan for this project. At a minimum, thelocationof the detention system shallbe shown along with thestub that was previously installed.As noted above, the existingcivil plan sheets are useful in showing the overall utility systems and should be a reference document only. 6/29/2016 comment -Show tightline around the buildings and connection to the on-site storm detention system. August 18, 2016–Response letter states “All remaining site improvements to be completed 5. have been noted on a copy of thepreviously reviewed and approved plans, a copy of which has been included for reference”. The civil plans that have been included for reference do not indicate which improvements have been constructed and which improvements are to be constructed under thesubjectpermit. Please update the site plan to indicate work to be completed under thispermit. Hatching existing and proposed surfaces differentlycould help. 6/29/2016 comment -Clearly distinguish between existing conditions and those improvements that are to be constructed under this permit (trash enclosure, on-site sidewalk, etc.). Provide details for elements to be constructed as applicable. Page 2of 2