BLD20161422 (2)U y OF E MO�� ' _ CITY OF EDMONDS 121 5TH AVENUE NORTH - EDMONDS, WA 98020 1890 PHONE: (425) 771-0220 - FAX: (425) 771-0221 STATUS: ISSUED 02/17/2017 Permit #: BLD20161422 BUILDING ' Expiration Date: 02/17/2018 Project Address: 19900 89TH PL W, EDMONDS Parcel No: 00506200001200 JOHN L1IKIM LOUISE WRIGHT PETER BLUE WOODWORKS 19900 89TH PL W 11706 8TH AVE NW C/O PETER BLUE EDMONDS, WA 98026-631 1 SEATTLE, WA 98177 715 N 200TH ST SHORELINE, WA 98133 (206)387-3319 (206)512-7444 (206)542-4281 LICENSE #: PET ERBW05IP4 EXP:10/06/2018 1B DESCRIPTION CONVERT GARAGE INTO LIVING ROOM, REMODEL KITCHEN, CREATE POWDER ROOM. ADD PERVIOUS DECKING. VALUATION: $177,920.00 PERMIT TYPE: Residential PERMIT GROUP: 04 - Alteration/Remodel GRADING: N CYDS: 0 TYPE OF CONSTRUCTION: VB RETAINING WALL ROCKERY: OCCUPANT GROUP: R-3/U OCCUPANT LOAD: FENCE: ( 0 X 0 FT.) CODE: 2015 OTHER: ------- OTHER DESC: ZONE: NUMBER OF STORIES: I I VESTED DATE: NUMBER OF DWELLING UNITS: 1 ILOT #: BASEMENT: 900 1 ST FLOOR: 1062 2ND FLOOR: 0 'O PO BASEMENT: 162 1 ST FLOOR: 420 2ND FLOOR: 0 3RD FLOOR: 0 GARAGE: 420 DECK: 0 OTHER: 440 13RD FLOOR: 0 GARAGE: -420 DECK: 0 OTHER: 0 BEDROOMS:3 BATHROOMS:2 1 BEDROOMS:0 BATHROOMS:I FRONTSETBACK SIDESETBACK REQUIRED: 25 PROPOSED: ] 3 REQUIRED: 7.5 PROPOSED: 6 REQUIRED: 15 PROPOSED: 77 HEIGHT ALLOWED-0 PROPOSED:O REQUIRED: 7.5 PROPOSED: 9 SETBACK NOTES: No change to existing setbacks. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18:27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THEBUILDING OFFICIAL OR HI ER DEPUTY AND ALL FEES ARE PAID. rgnature Print Name ate Released By Datet ATTENTION IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. UBC] 09/ IBC110/ IRCI 10. ..r ONLINE APPLICANT ASSESSOR OTHER M STATUS: ISSUED BLD20161422 CONDITIONS • Final approval on a project or final occupancy approval must be granted by the Building Official prior to use or occupancy of the building or structure. Check the job card for all required City inspections including final project approval and final occupancy inspections. • Any request for alternate design, modification, variance or other administrative deviation (hereinafter "variance") from adopted codes, ordinances or policies must be specifically requested in writing and be called out and identified. Processing fees for such request shall be established by Council and shall be paid upon submittal and are non-refundable. • Approval of any plat or plan containing provisions which do not comply with city code and for which a variance has not been specifically identified, requested and considered by the appropriate city official in accordance with the appropriate provision of city code or state law does not approve any items not to code specification. • Sound/Noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on weekdays and 10:00am and 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. • Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of whatever nature, arising directly or indirectly from the issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT T1ME LIMIT: SEE ECDC 19.00.005(A)(6) 425) 771-0220 EXT. 1333 1 ENGINEERING (425) 771 PUBLIC WORKS (425) 771-0235 1 PRF TREATNIFNT (425) 672-5755 1 RECYCLING 425 2754801 When calling for an inspection please leave the following information: Permit Number, Job Site Address, Type of Inspection being requested, Contact Name and Phone Number, Date Prefereed, and whether you prefer morning or afternoon. • B-Preconstruction meeting • B-Setbacks • B-Footings • B-Foundation Wall • B-isolated Footings/Piers • B-First Floor Framing • B-Plumb Rough In • B-Mechanical Rough In • B-Exterior Wall Sheathing • B-Roof Sheathing • B-Window Flashing • B-Shear Nailing • B-Height Verification • B-Framing • B-WallInsulation/Caulk • B Insulation/Energy • B-Building Final City of Edmonds DEVELOPMENT SERVICES RESIDENTIAL BUILDING PERMIT APPLICATION 121 5`h Avenue N, Edmonds, WA 98020 Phone 425.771.0220 2 Fax 425.771.0221 PLEASE REFER TO THE RESIDENTIAL BUILDING CHECKLIST FOR SUBMITTAL REQUIREMENTS PROJECT ADDRESS treet, Suite #, City State, Zip): M 00 t Y ,) r Parcel #: 60 0 9w oo Moco Subdivision/Lot #: ��- Project Valuation: $ -75 0 o a APTCANT: Phone: Fax: Address (Street, Cit , State, Zip): ac k ' 1JV W E-Mail Address: , LOUD WSW Y PROPERTY OWNER: Q, t- -jOt vo Phone: 2A -38T 331 Fax: Address (Street, City, State, Zi 101160 ibl 1 ` G% E-Mail Address: io o' Z 6 OAF, C aA& LENDING AGENCY: Phone: Fax: Address (Street, City, State, Zip): E-Mail Address: CONTRACTOR:* Phone: / Fax: Address (Street, City, State, Zip): -71S E-Mail Address: S L,. ,ram *Contractor must have a valid City of Edmonds business license prior to doing work in the City. Contact the City Clerk's Office at 425.775.2525 WA State License #/Exp. Date: City Business License #/Exp. Date: DETAIL THE SCOPE OF WORK: C_a& Vu 'O 6kUte-L >1Nty1 LWiAjCi- dYtA PROPOSED NEW SQUARE FOOTAGE FOR THIS PROJECT: Basement: -— -sq. ft. Select Basement Type: Finished LJ Unfinished LJ ls` Floor: (P4w,w� s . ft. Garage/Carport: s . ft. 2°d Floor: —d - -sq. ft. 0e&Cvrd Porch/Patio: id 40 s . ft. Bedrooms # -a-- Full-3/4 Bath # -"*,- Half -Bath # Ot er: s . ft. Fire Sprinklers: Yes U No LX I Retaining Wall: Yes LJ No Grading: Cut cu. yds. Fill -6— cu.yds. I Cut/Fill in Critical Area: Yes No I declare under penalty of perjury laws that the information I have provided on this form/application is true, correct and complete, and that I am the property owner or duly authorized agent of the property owner to submit a permit application to the City of Edmonds. s Print Name: A) P—tErftr Owner ❑ Agent/Other (specify): e Signature: Date: FORM A L:\Building New Folder 2010\DONE & x-ferred to L-Building-New drive\Form A2014.docx Updated: 1/17/2014 OE EDM -1 O v DEVELOPMENT SERVICES RESIDENTIAL BUILDING PERMIT APPLICATION FORM A Fsr 18go 121 5`h Avenue N, Edmonds, WA 98020 City of Edmonds Phone 425.771.0220 Q Fax 425.771.0221 Equipment Type MECHANICAL Appliance/Equipment Information (new and relocated) Total # Furnace Gas #_Elec #_Other: #_ BTUs: <100k_ >100k_ Location(s) Air Handler / VAV (circle selected) Gas #_Elec #_Other: #_CFM: <10k_ >10k_ Location(s) AC / Compressor / Boiler / Heat Pump / Gas #_Elec #_Other: # BTUs: <100k, 100k-500k, 500k-1Mil Roof Top Unit HP: <3, 3-15, 15-30 Location(s) (circle selected) Hydronic Heating Gas #_Elec #_In -Floor _Wall Radiant_ Boiler BTUs: Location Exhaust Fans (single Bath #Kitchen #Laundry # # duct) _Other: Fireplace Gas #J—Elec #_Other: #0,00Lcation(s) 1—W I04— —00'h 1 Dryer Duct IN 111 Appliance Type Appliance/Equipment Information (new and relocated) Total # AC Unit BTUs: Location(s): Furnace BTUs: Location(s): Water Heater BTUs: Location(s): Boiler BTUs: Location(s): Other: BTUs: Location(s): Fireplace/Insert BTUs: Location(s): Stove/Range/Oven Dryer Outdoor BBQ TOTAL OUTLETS PLUMBING Fixture Type (new and relocated) FIXT URE' COUNT Total # Fixture Type (new and relocated) Total # Water Closet (Toilet) ( Pressure Reduction Valve/Pressure Regulator Sink ('the , laundry, Za to , bar, eye wash, etc.) Water Service Line Tub/Shower Drinking Fountain Dishwasher Clothes Washer Hose Bib Backflow Prevention Device (e.g. RBPA, DCDA, AVB) Water Heater Tankless? Yes No ❑ Hydronic Heat in: Floor Wall ❑ Floor Drain/Floor Sink Other: Refrigerator water supply (for water/ice dispenser) Other: FORM A L:\Building New Folder 2010\DONE & x-ferred to L-Building-New drive\Form A2014.docx Updated: 1/17/2014 City of Edmonds Site Classification Worksheet Page 1 of 2 v V: OCT 2 6 2016 DEVrLOKanl OI SERVICES CTR. CITY OF EDMONDS �h� � x`'� The project's Site Classification will dictate the specific stormwater management requirements applicable to your site. Completing this worksheet will help determine the amount of regulated impervious surface and whether your project falls into the classification of a Small Site (Category 1 or Category 2), or a Minor Site. Please reference the GlossgU (1212. 10-11) Figures D and E, (pp. 8-9), and Examples (pp. 11-12), to assist with completion of this worksheet 1) Is Permeable Pavement' Proposed For Use on this Site? (� Yes No Refer to Stormwater Supplement Chapter 5.1 If YES, the subject area is to be considered impervious for initial site classification purposes. Include total permeable pavement area in the calculation of Non -Regulated Replaced and/or New impervious surface areas in the table below. 2) Determine the Amount and Type of Existing & Proposed Impervious Surface for the Site Refer to Stormwater Supplement Chapter 2 and Fi . C Line 1: Identify the Non -Regulated Impervious Surface Area. Line 2: Identify the Replaced Impervious Surface Area, dividing the total between Exempt and Re ated; either or both may be zero. Note: For project classification purposes, Replaced Impervious may only be considered exempt under certain conditions. Refer to the Glossary and Figure D. Line 3: Identify the New Impervious Surface Area for your project. All impervious areas created post -July 7, 1977 or after the date of annexation into the City are regulated & should be included in this total unless they can be categorized separately as a Replaced -Regulated area. Line 4: Enter the sum of the total Replaced -Regulated plus the total New impervious areas. Line 5: Identify the total area currently mitigated by an existing city -approved stormwater management system. Line 6: Enter the sum of the value in Line 4 less the value in Line 5 to identify the total Regulated area in which stormwater controls have not yet been applied. Line 7: Identify the total area proposed to be mitigated through the use of Low Impact Development Techniques. Line 8: Identify the total area proposed to be mitigated through conventional Stormwater Management Techniques. ** Provide a copy of the following table on the drainage plan sheet for the proposed project'�'� Line Type Area (square feet) 1. Non -Regulated 31� 5 3 Exempt ° Regulated 2. Replaced 2-7 S r_ 3. 4. New (Post 1977) 4 4 4 4 4 4 4 4 4 + G� Total Regulated Impervious Area Mitigation required i. in excess of 2000s - �-�- S. 6. Total Area Mitigated by Existing Stormwater Management System(s)-8- Regulated Area Not Yet Mitigated f = I 7. Area Proposed to be Mitigated by Low Impact Development Techniques _1 ___.4U_ 8. Area Proposed to be Mitigated through Conventional SWM Techniques 1 (e.g. porous asphalt, porous concrete, paver blocks, concrete open celled paving grids, or plastic lattices filled with turf or stone) Revised on 310512012 E72-SWM Erosion_Control-03.05.12.doc Page 5 of 12 City of Edmonds Site Classification Worksheet Page 2 of 2 3) Determine the Total Area of Land Disturbing Activity sf Refer to Stormwater Supplement Chapter 8 1 4) Determine the Quantity of Grading, Fill and/or Excavation 2_cy 5) Will the project convert3/ Acre or More of Native Vegetation to Lawn or Yes No Landscaped Area? 0 6) Identify the Watershed the Existing Site Runoff Discharges to Refer to Stormwater Supplement Chapter 2.3 Based on Site Location and Watershed Map — Figure-C. Check all that apply. A. ❑ Direct Discharge B. ❑ Creek or Lake Basin ❑ Edmonds Way Basin ❑ Puget Sound Basin ❑ Puget Sound Piped Basin DETERMINE PROJECT CLASSIFICATION USING THE INFORMATION ABOVE AND THE PROTECT CLASSIFICATION CHART (Figure B, pg 4) ❑ Small Site - Category 1 El Small Site - Category 2 Minor Site Stormwater Supplement Stormwater Supplement Stormwater Supplement. Chapter 5 Chapter S Chapter 6 Revised on 310512012 E72-SWA _Erosion_Control-03.05.12.doc Page 6 of 12 SOUND STRUCTURAL SOLUTIONS OCT 26 20105 E N G x N E E R 5 DEVELONiviENTSERVICES CTR. CITY OF EDMONDS John Kim Client 19900 89th Place W Edmonds, WA 98026 phone fax SSS # 1 s1607010 Hart -Kim Residence Project 2 Strory SFR Remodel Identification on Louise Wright (206-512-7444) WAC 196-23-070 Section Engineering Calculations 1 Design Criteria 2 Wind & Earthquake Design 3 Framing Analysis 4 Foundation Design 6628 212th Street SW, Suite 205 - Lynnwood, WA 98036 - Ph: 425-778-1023 - Fax: 206-260-7490 DESIGN CRITERIA 6628 212th Street SW, Suite 205 - Lynnwood, WA 98036 - Ph: 425-778-1023 - Fax: 206-260-7490 WIZ 'L "9�iP2096 Design Maps Summary Report 1° USGS . Design Maps Summary Report : User--Specified.jnput Report Title Hart-IGm Residence Fri September 2, 2016 22:28:46 UTC Building Code Reference Document 2012/2015 International Building Code (which utilizes USGS hazard data available in 2008) Site Coordinates 47.818840N, 122.353740W Site Soil Classification Site Class D - "Stiff Soil" Risk Category I/II/III USGS-Provided Output Ss = 1.278 g SP,§ = 1.278 g Sns = 0.852 g Si = 0.501 g Sr,i = 0.751 g S"t = 0.501 g For information on how the SS and S1 values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. MCER Response Spectrum 1.43 1.3G 1.17 1.04 o.sl 0.76 in 0.65 0.52 0.35 0.26 0.13 0.00 0.00 0.20 0.40 0.60 0.60 1.00 1.20 1.40 1.60 1.80 2.00 Period, T (sec) 0.99 0.90 o. s1 0. xz 0.63 0� 0.54 t0.45 0."M - F 0.2: 0.16 0.09 0.00 0.00 0.20 0.40 0.60 0.90 1.00 1.20 1.40 1.60 1.90 2.00 Period, T (sec) Design Response Spectrum Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein. This tool is not a substitute for technical subject -matter knowledge. httpJlehpl-earhluake.cr.usgs.g NldesignmaWus/sunmary.php?template=minimai8datitude=47.818841799132898longitude=-122.353740431332518siteclass=... 1/9 J SOUND STRUCTURAL SOLUTIONS ;5ss E N G I N E E R S LATERAL ANALYSIS 6628 212th Street SW, Suite 205 - Lynnwood, WA 98036 - Ph: 425-778-1023 - Fax: 206-260-7490 _a Lateral Analysis s1607010 Number of Diaphragms Code General Design Criteria 1 15 IBC 2015 International Building code & 2010 ASCE7 DesignLoads s Dead Live Snow Seismic is sc Roof 1 15 --- 25 15 Rf Deck 2 20 40 25 20 Floor 1 10 40 --- 10 Floor 2 17 40 --- 17 Wall 10 --- --- 10 Wall 12 --- --- 12 Misc 1 1 --- --- 1 Species of Framing Lumber Shearwall Stud Spacing Risk Category Wind Design Criteria Wind Load Design Procedure Wind Importance Factor Basic Wind Speed Surface Roughness Wind Exposure Category TopogrAphic Factor Enclosure Classification Internal Pressure Coefficient Seismic Design Data Seismic Load Design Procedure Seismic Importance Factor Seismic Design Category Mapped Spectral Accelerations, MSA Short Period Acceleration 1-Second Accelleration Long -Period Transition Period Spectral response coefficient Spectral response coefficient Site Classification Seis. Force Resisting System Response Modification Factor R Seismic Response Coefficient Cs Design Base Shear Overstrength Factor HF 16" oc II 2010 Directional Procedure I 1.00 110 mph B B Kzt 1.00 Enclosed Building +/- 0.18 2010 Equiv. Lateral Force Procedure I 1.00 D Ss 1.278 Sl 0.501 TL 6 W 0.85 Spi 0.50 D Table 12.2-1: A-13 Transverse Longitudinal 6.5 6.5 0.131 0.131 3768 4080 Qo 2.5 sec. 160902_SSSlateral 160906_s1607010 DC Wind Loads Ridge Elevation 14 ft Eave Height 8 ft Mean Roof Height, h 11 ft Least Horizontal Dimension, LHD 25.5 ft Transverse Direction B Dimension 25.5 ft L Dimension v 63 ft Transverse Direction (WW) Roof Pitch 0 :12 LEVEL Wall Area Roof Area (Horiz Proj) S ft 1 137 sq ft sq ft Transverse Direction (LW) Roof Pitch :12 LEVEL Wall Area Roof Area (Horiz Proj) (sq ft 1 1371 sq ft 0 sq ft Wind Variables Basic Wind Speed, V Directionality Factor, Kd Gust Effect Factor, Gf Wind Loads Help XPE�WL'a N f Longitudinal Direction (WW) B Dimension 63 ft L Dimension 25.5 ft Longitudinal Direction (WW) Roof Pitch 7 :12 LEVEL Wail Area Roof Area (Horiz Proj) (sq ft) 1 2841 sq ft 410 sq ft Longitudinal Direction (LW) Roof Pitch :12 LEVEL WallArea Roof Area (Horiz Proj) (sq ft) 1 2841 sq ft 410 sq ft 110 mph Topociraphic Factor," 0.85 Velocity Pres. Exp. Coeff. Kz 0.85 Velocity Pressure. oti . .XPELVW'y� 1.00 0.57 15.01 psf Main Wind Force Resisting System - Diaphragm Design Loads XPEMWF, s 2010 Directional Procedure Direction Transverse Longitudinal SUM 2264 7812 Load Case 1 L L-16psf 1 2264 7812 160902_SSSlateral 160906_s1607010 WF(2) Seismic Loads Yes XPELSi Diaphragm 1 I area (fe) I unit weight (psf trans - w, long - w, height (ft) 4.5 Roof 1 1600 1 15 1 28750 31125 Floor 1 10 Floor 2 17 Misc 1 1 Mass (Ibs) 24000 trans - wX long - w, Sum of Effective Seismic Weights (Ibs) 300500 255375 160902_SSSlateral 160906_s1607010 EF - Mapped Spectral Accelerations XPEMSA;: Ss 1.278 fan 1 000 Sos 0.85 Si 0.501 Fv' ?1500'; So' 0.50 Seismic Design Category D Seismic Importance Factor IE 1.00 Seismic Use Group II Site Classification D 2010 Equiv. Lateral Force Procedure 'j.wXPEEtFF` Transverse Longitudinal Approximate Period Ct = 0.020 0.020 Parameters x= 0.75 0.75 Approximate Fundamental Period T= 0.145 sec 0.145 sec hn= 14.0 ft TL = 6 sec Transverse Longitudinal CS = 0.131 0.131 Ibs EQ 12.8-2 (Maximum) CS = 0.532 0.532 Ibs EQ 12.8-3 / 8.4 (Minimum) CS = 0.037 0.037 Ibs EQ 12.8-5 (Minimum) CS = 0.010 0.010 Ibs EQ 12.8-5 (Minimum) CS = 0.010 0.010 Ibs EQ 12.8-6 Calculation of Seismic Response Coefficient ,1CPE3RC; Response :Modification Coefficient and Seismic Resoonse Coefficient Dia h. Trans Cs Mass V Long Cs Mass V 1 6.5 0.131 28750 3768 6.5 0.131 31125 4080 0 6.5 0.131 23750 0 6.5 0.131 33250 0 -1 6.5 0.131 62000 0 6.5 0.131 47750 0 4.5 _ 0.189 62000 0 6.5 0.131 47750 0 fl 6.5 0.131 62000 0 6.5 0.131 47750 0 6.5 0.131 162000 0 6.5 0.131 47750 0 Transverse Longitudinal Base Shear, ht V = 3768 Ibs V = 4080 Ibs Vertical Distributionof Seismic Forces XPEVD3k'. k= 1.00 Transverse Longitudinal Diaph. hX wX wxhxk Cvx wx wXhXk C'X 1 14 35875 502250 1.000 35875 502250 1.000 0 0 45125 0 0.000 45125 0 0.000 -1 0 71500 0 0.000 1 71500 0 0.000 -2 0 71500 0 0.000 71500 0 0.000 -3 0 71500 0 0.000 71500 0 0.000 -4 0 71500 0 0.000 71500 0 0.000 502250 502250 Diaphragm 1 0 -1 -2 -3 -4 sum Transverse Ibs Ibs Ibs Ibs Ibs Ibs 3768 0 0 0 0 0 3768 sum Longitudinal Ibs Ibs Ibs Ibs Ibs Ibs 4080 0 0 0 0 0 4080 160902_SSSlateral 160906_s1607010 EF Allowable Stress Design Loads 2010 Directional Procedure Wind Load Combination 0.6D+0.6W+H %of DL used in OT 60% Wind Design Loads Fx Transverse Longitudinal Diaphragm Force (Ibs) Force (Ibs) 1 1358 4687 2010 Equiv. Lateral Force Procedure Seismic Load Combination (0.6 - 0.14Sps)D +0.7pQE +H % of DL used in OT 48% Seismic Design Loads, Fx p = 1.30 1.30 Transverse I Longitudinal Diaphragm Force (Ibs) Force (Ibs) 1 3429 1 3713 Principle of Mechanics - cont Where, v = shear per linear foot of shearwall w = width of shearwall h = height of shearwall D = resisting dead load centered over shearwall P = resisting dead load at end of shearwall Shearwall calculations follow, where, V. Total force in the diaphragm above story (x), pounds (Ibs) % Percent of Vx tributary to the shearwalls (SW) in the wall line VD, Force from the diaphragm above that transfers to the SW's, Ibs VTx+1 Force from the SW's above that transfers to the SW's, Ibs VT. Total force in the SW s (VD, +VTx+,), Ibs d, d, df dfa Twx+I Twx Tex+I Tex Total length of SW's (F w), feet (ft) Linear force in the SW s (Vr,/L), pounds per foot (plf) Greater of v induced by wind or earthquake, pif Maximum uplift force of the SW's, Ibs 1214.2 rx+n Free Body Diagram of a ShearWall Greater of v in the sheathing induced by wind per 2306.4.1 or earthquake per 2305.3.4, plf Width of SW, ft Height of SW, ft Tributary distance of roof (used to calculate D) along the width of the SW, ft Tributary distance of roof (used to calculate P) adjacent to the width of the SW, ft Tributary distance of floor (used to calculate D) along the width of the SW, ft Tributary distance of floor (used to calculate P) adjacent to the width of the SW, ft Wind uplift force of the SW above that transfers to the SW, Ibs Wind uplift force of the SW, Ibs Earthquake uplift force of the SW above that transfers to the SW, Ibs Earthquake uplift force of the SW, Ibs 160902_SSSlateral 160906_s1607010 DL V— Wall Line Story (x) Direction Sheathing Shear SW Dimensions Tributary Dead Loads Wind Uplift Earthquake Uplift 1 1 Trans vs w h d, dfe df clm Twx+f TwX Tex., TeX WIND E-QUAKE 43 5.75 9.5 10 10 -722 -300 43 5.25 9.5 10 2 -340 6 43 23.00 9.5 -625 -223 VTx 679 1715 v 17 43 Max Tx 243 43 6.00 9.5 -44 243 L vF vs 40.00 43 43 Wall Line Story (x) Direction Sheathing Shear SW Dimensions Tributary Dead Loads Wind Uplift Earthquake Uplift 2 1 Trans vs w h d, d. df df. TwX.tf Twx Tex.f Tex WIND E-QUAKE 114 3.50 9.5 10 10 1 -390 1 230 99 4.00 9.5 10 2 -88 472 84 8.00 9.5 41 575 VTx 679 1715 v 33 84 Max Tx 144 658 84 5.00 9.5 144 658 L vF vs 20.50 84 114 160902_SSSiateral 160906 s1607010 Wall Line Story (x) Direction Sheathing Shear SW Dimensions Tributary Dead Loads Wind Uplift Earthquake Uplift A 1 Long vs w h dr d. df dN TwX+f TwX TeX., TeX WIND E-QUAKE 248 7.50 9.5 2 2 2559 2023 VTX 2344 1856 v 312 248 Max TX 2559 2023 L vF vs 7.50 312 248 160902_SSSlateral 160906_s1607010 FIR Shear Transfer Connections XPSTC Fasteners and Spacing N o M r\ pp tp .Ni a � * to M U 2x Plates 3x Plates G N x x x x c ,n u t S 't0 u Q J = m O, D• m [p (p u U H Z C C C O a n m W O V)i a vOi a m 2 -y ca Y m i Man E a in in in Ln N ° boa N cc ii N 1 In -1 N A 150 11 9 48 46 10 33 16 1 101 75 110 13 1 332 1 5 ?' 21 20 4 15 7 31 34 49 R RIM, Shearwall Capacities from SDPWS-2008 Table 4.3A MINIMUM Tabulated m Go NOMINAL PANEL value Adjusted 3 o U) THICKNESS Nail or Staple size based on for HF @ 4 (inch) DF 16"oc 6 242 7/16" 8d @ 6"oc 260 242 4 353 7/16" 8d @ 4"oc 380 353 The above allowable capacities were reduced by 2. Shears are 2 for ASD and are for Seismic loads. Allowable permitted to Wind loads are 1.4 greater. This office be increased 3. G=0.43 decreases the wind sheathing shear, v s, to values [1-(0.5-0.43)] shown for = 0.93 demand by this factor rather than using the 15/32-Inch increased capacity. That way, only one set of sheathing... 160902_SSSlateral 160906_s 1607010 ST Shear Transfer Notes [1] TABLE 11N [pg97 NDS] Z=89 Ibs for a 16d box nail (D=0.135) in Hem -Fir G=0.43 and multiplied by the load duration factor TABLE 10.3.1 [pg58 NDS] for wind/earthquake which is CD=1.6 found in TABLE 2.3.2 [pg9 NDS] [2) Value from note 1 then multiplied by the Toe -Nail Factor SECTION 11.5.4 [pg78 NDS] for nominal lateral design values Ctn=0.83 [3] the A35 is used in loading condition 4 in an F1 direction of load according to Simpson designations for SPF/HF Lateral(133/160) Z=450 Ibs [pg146 C-2005] [4] [5] for SPSF/HF Lateral(133/160) Z=130 lbs [pg142 C-2005] [6] the H1 is used in an F1 loading according to Simpson designations for SPF/HF Lateral(133/160) Z=415 Ibs [pg142 C-2005] [7] the DTC is used in an F2 loading according to Simpson designations for SPF/HF Lateral(133/160) Z=210 Ibs [pg112 C-2005] [8) TABLE 11E [pg85 NDS] Z=570 Ibs for a 1/2" diameter bolt in 1-1/2" side member of Hem -Fir G=0.43 and multiplied by the load duration factor TABLE 10.3.1 [pg58 NDS] for wind/earthquake which is CD=1.6 found in TABLE 2.3.2 [pg9 NDS] Sill plates resisting a design load greater than 350 plf shall not be less than a 3-inch nominal member. Exception: With design load less than 600plf the sill plate is permitted to be a 2-inch nominal member if the sill plate is anchored by two times the number of bolts requiredby design. [9] TABLE 11E [pg85 NDS] Z=830 Ibs for a 5/8" diameter bolt in 1-1/2" side member of Hem -Fir G=0.43 and multiplied by the load duration factor TABLE 10.3.1 [pg58 NDS] for wind/earthquake which is CD=1.6 found in TABLE 2.3.2 [pg9 NDS] Sill plates resisting a design load greater than 350 pif shall not be less than a 3-inch nominal member. Exception: With design load less than 600pif the sill plate is permitted to be a 2-inch nominal member if the sill plate is anchored by two times the number of bolts requiredby a- (10] TABLE 11E [pg85 NDS] Z=700 Ibs for a 1/2" diameter bolt in 2-1/2" side member of Hem -Fir G=0.43 and multiplied by the load duration factor TABLE 10.3.1 [pg58 NDS] for wind/earthquake which is CD=1.6 found in TABLE 2.3.2 [pg9 NDS] [11] TABLE 11E [pg85 NDS] Z=1040 Ibs for a 5/8" diameter bolt in 2-1/2" side member of Hem -Fir G=0.43 and multiplied by the load duration factor TABLE 10.3.1 [pg58 NDS] for wind/earthquake which is CD=1.6 found in TABLE 2.3.2 [pg9 NDS] 160902_SSSlateral 160906_0607010 ST -' Shear Wall Summary Rio Rio Width ` SW ' wF Stressed vs Stressed Notes 1 1 40.00 A 6 43 29% 43 18% 2 1 20.50 A 6 84 56% 114 47% A 1 7.50 B 4 312 94% 248 70% 160902_SSSlateral 160906_s1607010 SW Holdown Summary Wind Wind Wind Seismic Seismic Seismic �, Capacity Capacity Capacity Capacity Capacity Capacity o Cn Uplift W Uplift E Holdown Midwall Corner Endwall Midwall Corner Endwall 1 1 0 243 2 1 144 658 A 1 2569 2023 HTT5KT(b) 5360 @ 5360 @ 5360 @ 5360 @ 5360 @ 5360 @ 48% 48% 48% 38% 38% 38% 160902_SSSlateral 160906_s1607010 Sw GRAVITY ANALYSIS 6628 212th Street SW, Suite 205 - Lynnwood, WA 98036 - Ph: 425-778-1023 - Fax: 206-260-7490 Wood Beam FIe=Sadobstsl6lsl60719150BE-11WO1609-11 ENERC-1.EC6 ENERCALC, INC.1983-2016, Wid:6.16.7.21, Ver.6.16.7.21 Description : 1-1 CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension Load Combination IBC 2015 Fb - Compr Fe - Pdl Wood Species : Trus Joist Fc - Perp Wood Grade : TimberStrand LSL 1.55E Fv Ft Beam Bracing Beam is Fully Braced against lateral -torsional buckling D 0.1875 S 0.31251 2,325.0psi E: Modulus of Elasticity 2,325.0psi Ebend-xx 1,550.Oksi 2,050.0 psi Eminbend - xx 787.82ksi 800.0 psi 310.0 psi 1,070.0psi Density 44.990pcf 3.5xl4 Span = 17.0 it Applied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load : D = 0.0150, S = 0,0250 ksf, Tributary Width =12.50 ft, (ROOF) DESIGN SUMMARY 'Maximum Bending Stress Ratio = 0.719 1 Maximum Shear Stress Ratio Section used for this span 3.5x14 Section used for this span fb : Actual = 1,895.77psi fv : Actual FB : Allowable = 2,636.10psi Fv: Allowable Load Combination +D+S Load Combination Location of maximum on span = 8.500ft Location of maximum on span Span # where maximum occurs = Span # 1 Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection 0.476 in Ratio = 428>=360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.762 in Ratio = 267>=240. Max Upward Total Deflection 0.000 in Ratio = 0 <240.0 _ . -............... Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Segment Length Span # M V C d C IN C i Cr Cm C t C L Moment Values M fb Fb 0.365 :1 3.5x14 130.10 psi 356.50 psi +D+S 0.000 ft Span # 1 Shear Values V fv Fv D Only 0.00 0.00 0.00 0.00 Length =17.0 ft 1 0.345 0.175 0.90 0.986 1.00 1.00 1.00 1.00 1.00 6.77 710.91 2063,03 1.59 48.79 279.00 +D+S 0.986 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 17.0 ft 1 0.719 0.365 1.15 0.986 1.00 1.00 1.00 1.00 1.00 18.06 1,895.77 2636.10 4.25 130.10 356.50 +0+0.750S 0.986 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length =17.0 If 1 0.607 0.308 1.15 0.986 1.00 1.00 1,00 1.00 1.00 15.24 1,699.66 2636.10 3.59 109.77 356.50 +1.140D 0.986 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length =17.0 ft 1 0.221 0.112 1.60 0.986 1.00 1.00 1.00 1.00 1.00 7.72 810.44 3667.62 1.82 55.62 496.00 +1.105D+0.750S 0.986 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 17.0 ft 1 0.456 0,232 1.60 0.986 1.00 1.00 1.00 1.00 1.00 15.95 1,674.20 3667.62 3.75 114.90 496.00 +0.60D 0.986 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length =17.0 ft 1 0.116 0.059 1.60 0,986 1.00 1.00 1.00 1.00 1.00 4.06 426.55 3667.62 0.96 29.27 496.00 Description : 1-1 Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V C d C FN C i Cr Cm C t C L M fb F'b V fv Pv +0.4601) 0.986 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length =17.0 ft 1 0.089 0.045 1.60 0.986 1.00 1.00 1.00 1.00 1.00 3.12 327.02 3667.62 0.73 22.44 496.00 VBt'tICc1I R@alCtlOt15 Support notation :Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 4.250 4.250 Overall MINimum 0.956 0.956 D Only 1.594 1.594 +D+S 4.250 4.250 +0+0.750S 3.586 3.586 +0.601) 0.956 0.956 S Only 2.656 2.656 Wood Beam File=S:IJobsls161s16071S150BE-11WO1609-11_ENERC-1.EC6 . ENERCALC, INC.1983-2016, Build:6.16.7.21, Ver.6.16.7.21 Description : 1-2 CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method : Allowable Stress Design Fb - Tension 900.0 psi E: Modulus of Elasticity Load Combination i BC 2015 Fb - Compr 900.0 psi Ebend- xx 1,600.Oksi Fc - Pdl 1, 350.0 psi Eminbend - xx 580.Oksi Wood Species : Douglas Fir - Larch Fc - Perp 625.0 psi Wood Grade : No.2 Fv 180.0 psi Ft 575.0 psi Density 31.20pcf Beam Bracing : Beam is Fully Braced against lateral -torsional buckling D(1.359),S(2.266) 4x12 Span =16.0 ft _... _. Applied Loads ........ _. _. _.._....... Service loads entered. Load Factors _. _...... .... .._. will be applied for calculations. Uniform Load: D = 0.010, L = 0.040 ksf, Tributary Width = 2.0 ft, (FLOOR) Point Load : D=1.359, S = 2.266 k @ 0.0 ft, (1-1r) DESIGN SUMMARY. _..... _ _ Maximum Bending Stress Ratio = 0,525- 1 Maximum Shear Stress Ratio = 0.169 : 1 Section used for this span 4x12 Section used for this span 4x12 fb : Actual = 520.13 psi fv : Actual = 30.48 psi FB : Allowable = 990.00psi Fv: Allowable = 180.00 psi Load Combination +D+L Load Combination +D+L Location of maximum on span = 8.000ft Location of maximum on span = 0.000ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.179 in Ratio = 1075>=350 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.223 in Ratio = 860>=240. Max Upward Total Deflection 0.000 in Ratio = 0<240.0 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V C d C FN C i Cr Cm C t C L M tb Fb _ V fv Fv D Only 0.00 0.00 0.00 0.00 Length =16.0 ft 1 0.117 0.038 0.90 1.100 1.00 1.00 1.00 1.00 1.00 0.64 104.03 891.00 0.16 6.10 162.00 +D+L 1.100 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 16.0 ft 1 0.525 0.169 1.00 1.100 1.00 1.00 1.00 1.00 1.00 3.20 520.13 990.00 0.80 30.48 180.00 +D+S 1.100 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length =16.0 ft 1 0.091 0.029 1.15 1.100 1.00 1.00 1.00 1.00 1.00 0.64 104.03 1138.50 0.16 6.10 207.00 +0+0.7501-+0.750S 1.100 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 16.0 it 1 0.365 0.118 1.15 1.100 1.00 1.00 1.00 1.00 1.00 2.56 416.10 1138.50 0.64 24.38 207.00 +1.140D 1.100 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length =16.0 ft 1 0.075 0.024 1.60 1,100 1.00 1.00 1.00 1.00 1.00 0.73 118.59 1584.00 0.18 6.95 288.00 +1.105D+0.750L+0.750S 1.100 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 I'll, OOBEa[.:6.16-:7LENERC-1 EC6 sm 87 ENERCAN198320]6,Bwld21; Ver6.16.7.21 Description : 1-2 Load Combination Max Stress Ratios MomentVelues Shear Values Segment Length Span # M V C d C FN C i Cr Cm C t C L M tb F'b V fv Fv Length =16.0 ft 1 0.270 0.087 1.60 1.100 1.00 1.00 1.00 1.00 1.00 2.63 427.02 1584.00 0.66 25.02 288.00 +0.60D 1.100 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length =16.0 ft 1 0.039 0.013 1.60 1.100 1.00 1.00 1.00 1.00 1.00 0.38 62.42 1584.00 0.10 3.66 288.00 +0.460D 1.100 1.00 1'00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length =16.0 ft 1 0.030 0.010 1.60 1.100 1.00 1.00 1.00 1.00 1.00 0.29 47.85 1584.00 0.07 2.80 288.00 Vertical Reactions Support notation :Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 3.785 0.800 Overall MINIMUM, 0,640 0,096 D Only 1.519 0,160 +D+L 2.159 0.800 +D+S 3.785 0.160 +D+0.750L+0.750S 3.699 0.640 +0.601) 0.911 0,096 L Only 0.640 0.640 S Only 2.266 0.000 Wood Beam Fle = S:Wobsls161s16O71S150BE-11WO1609--1LENERC-1.EC6 _ ENERCALC, INC. 1983 2016, Build:6.16.7.21, Ver.6.16.7.21 Description : 1-3 CODE REFERENCES Calculations par NDS 2015,180 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension 900.0 psi E: Modulus of Elasticity Load Combination IBC 2015 Fb - Compr 900.0 psi Ebend- xx 1,600.Oksi Fc - Pdl 1,3%0 psi Eminbend - xx 580.Oksi Wood Species : Douglas Fir - Larch Fc - Perp 625.0 psi Wood Grade ; No.2 Fv 180.0 psi Ft 575.0 psi Density 31.20pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling 00.09 S0.15 - -- 4x8 Span = 8.0 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load: D = 0.0150, S = 0.0250 ksf, Tributary Width = 6.0 ft, (ROOF) DESIGN SUMMARY 1'! Maximum Bending Stress Ratio 0.55a 1 Maximum Shear Stress Ratio = 0.274 : 1 Section used for this span 4x8 Section used for this span 4x8 fb : Actual 751.43psi fv : Actual = 56.75 psi FB : Allowable = 1,345.50psi Fv : Allowable = 207.00 psi Load Combination +D+S Load Combination +D+S Location of maximum on span = 4.000ft Location of maximum on span = 0.000ft Span #where maximum occurs = Span # 1 Span #where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.078 in Ratio = 1227-360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.125 in Ratio = 767> 240. Max Upward Total Deflection 0.000 in Ratio = 0 <240.0 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Segment Length Span # M V C d C FN C i Cr D Only Cm C t CL Length = 8.0 ft 1 0.268 0.131 0.90 1.300 1.00 1.00 1.00 1.00 1.00 +D+S 1.300 1.00 1.00 1.00 1.00 1.00 Length = 8.0 ft 1 0.558 0.274 1.15 1.300 1.00 1.00 1.00 1.00 1.00 +D+0.750S 1,300 1.00 1.00 1.00 1.00 1.00 Length = 8.0 ft 1 0.471 0.231 1.15 1.300 1.00 1.00 1.00 1.00 1.00 +1.140D 1.300 1.00 1.00 1.00 1.00 1.00 Length = 8.0 ft 1 0.172 0.084 1.60 1.300 1.00 1.00 1.00 1.00 1.00 +1.105D+0.750S 1.300 1.00 1.00 1.00 1.00 1.00 Length = 8.0 ft 1 0.354 0.174 1.60 1.300 1.00 1.00 1.00 1.00 1.00 +0.60D 1.300 1.00 1.00 1.00 1.00 1.00 Length = 8.0 It 1 0.090 0.044 1.60 1.300 1.00 1.00 1.00 1,00 1.00 Moment Values Shear Values M fb Fb V fv Pv 0.00 0.00 0.00 0.00 0.72 281.79 1053.00 0.36 21.28 162.00 0.00 0.00 0.00 0.00 1.92 751.43 1345.50 0.96 56.75 207.00 0.00 0.00 0.00 0.00 1.62 634.02 1345.50 0.81 47.88 207.00 0.00 0,00 0.00 0.00 0.82 321.24 1872.00 0.41 24.26 288.00 0.00 0.00 0.00 0.00 1.70 663.61 1872.00 0.85 50.12 288.00 0.00 0.00 0.00 0.00 0.43 169.07 1872.00 0.22 12.77 288.00 FIe = S:U6b*161s160713150BE- ealrn _ ENERCACC. INC. 1983-2616 Description : 1-3 Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V C d C FN C i Cr Cm C t C L M- ib Fb V fv Fv -0.4601) 1.300 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 8.0 ft 1 0.069 0.034 1.60 1.300 1.00 1.00 1.00 1.00 1.00 0.33 129.62 1872.00 0.17 9.79 288.00 VBGtICai R>rac onj., . ' ,`. :_ . Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 0.960 0.960 Overall MINimum 0.216 0.216 D Only 0.360 0.360 +O+S 0.960 0.960 4".750S 0.810 0.810 +0.60D 0.216 0.216 S Only 0.600 0.600 Description : 1-4 CODE ME Calculations per NDS 2015, IBC 2015, CBC 2016, ASCB 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension 900.0 psi E : Modulus of Elasticity Load Combination I BC 2015 Fb - Compr 900.0 psi Ebend- xx 1,600.Oksi Fc - Prll 1,350.0 psi Eminbend - xx 580.Oksi Wood Species : Douglas Fir - Larch Fc - Perp 625.0 psi Wood Grade : No.2 Fv 180.0 psi Ft 575.0 psi Density 31.20pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling - _.. D 0.15 S 0.25 - - .... .... 4x10 Span =9.0ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load: D = 0.0150, S = 0.0250 ksf, Tributary Width =10.0 ft, (ROOF) DESIGN SUMMARY e ;Maximum Bending Stress Ratio - 0.7841 Maximum Shear Stress Ratio = 0.403 :1 Section used for this span 4x10 Section used for this span 4x10 fb : Actual = 973.72psi fv : Actual = 83.40 psi FB : Allowable = 1,242.00psi Fv: Allowable = 207.00 psi Load Combination +D+S Load Combination +D+S i Location of maximum on span = 4.500ft Location of maximum on span = 0,000ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.101 in Ratio = 1074>=360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.161 in Ratio = 671 >=240, Max Upward Total Deflection 0.000 in Ratio = 0 <240.0 Max1murnForces & Stresses.for Load Cornbirtations Load Combination Max Stress Ratios Segment Length Span # M V Cd C FN C i Cr D Only Length = 9.0 ft 1 0.376 0.193 0.90 1.200 1.00 1.00 +D+S 1.200 1.00 1.00 Length = 9.0 ft 1 0.784 0.403 1.15 1.200 1.00 1.00 +D+0.7508 1.200 1.00 1.00 Length = 9.0 ft 1 0.661 0.340 1.15 1.200 1.00 1.00 +1.140D 1100 1.00 1.00 Length = 9.0 ft 1 0.241 0.124 1.60 1.200 1.00 1.00 +1.105D+0.750S 1.200 1.00 1.00 Length = 9.0 ft 1 0.498 0.256 1.60 1.200 1.00 1.00 +0.60D 1.200 1.00 1.00 Length = 9.0 ft 1 0.127 0.065 1.60 1.200 1.00 1.00 C m C t C L Moment Values M fb _ Fb V Shear Values fv Fv 0.00 0.00 0.00 0.00 1.00 1.00 1.00 1.52 365.15 972.00 0.68 31.27 162.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 1.00 1.00 1.00 4.05 973.72 1242.00 1.80 83.40 207.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 1.00 1.00 1.00 3.42 821.58 1242.00 1.52 70.37 207.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 1.00 1.00 1.00 1.73 416.27 1728.00 0.77 35.65 288.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 1.00 1.00 1.00 3.58 859.92 1728.00 1.59 73.65 288.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 1.00 1.00 1.00 0.91 219.09 1728.00 0.41 18.76 288.00 Description : 1-4 Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V C d C FN C i Cr Cm C t C L M fb __ Pb V fv F'v +0.460D 1.200 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 9.0 ft 1 0.097 0.050 1.60 1.200 1.00 1.00 1.00 1.00 1.00 0.70 167.97 1728.00 0.31 14.39 288.00 i/er$ic�l>R@�C$#OtIS Support notation :Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 1.800 1.800 Overall MINimum 0.405 0.405 D Only 0.675 0.675 +D+S 1.800 1.800 +D+0.7508 1.519 1.519 +0.601) 0.405 0.405 S Only 1.125 1.125 In/ood Bea 1 - FIe=S:Wobsls161s16071S15QBE-11WO1609-11 ENERC-l.ECS ENERCALC, ING.1983-2016, 13410.16:7.21, Ver6.16.7.21 Description: 0-1 CODE REFERENCES Calculations per NOS 2015, tBC 2015, CSC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension 900.0 psi E : Modulus of Elasticity Load Combination i BC 2015 Fb - Compr 900.0 psi Ebend- xx 1,600.Oksi Fc - Pill 1,350.0 psi Eminbend - xx 580.Oksi Wood Species : Douglas Fir - Larch Fc - Perp 625.0 psi Wood Grade : No.2 Fv 180.0 psi Ft 575.0 psi Density Beam Bracing : Beam is Fully Braced against lateral -torsional buckling _._....... ...... _.._...- D'0.095 L 0.38 I i 4x8 Span = 4.750 ft 31.20pcf Applied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load : D = 0,010, L = 0.040 ksf, Tributary Width = 9.50 ft, (FLOOR) DESIGN SUMMARY ---,_-.. __... _._..... _ ---_- Maximum Bending Stress Ratio = 0.446 1 Maximum Shear Stress Ratio Section used for this span 4x8 Section used for this span fb : Actual = 524.30psi fv : Actual FB : Allowable = 1,170.00 psi Fv : Allowable Load Combination +D+L Load Combination Location of maximum on span = 2.375ft Location of maximum on span Span # where maximum occurs = Span # 1 Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection 0.025 in Ratio = 2315 >=360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.031 in Ratio = 1852>=240, Max Upward Total Deflection 0.000 in Ratio = 0 <240.0 7,9sia lr] 0.370 :1 4x8 66.69 psi = 180.00 psi +D+L 0.000 ft Span # 1 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Segment Length Span # M V C d C IN C i Cr - CM - C t C L Moment Values M tb Fb -. V Shear Values fv Fv D Only 0.00 0.00 0.00 0.00 Length = 4.750 ft 1 0.100 0.082 0.90 1.300 1.00 1.00 1.00 1.00 1.00 0,27 104.86 1053.00 0.23 13.34 162.00 +O+L 1.300 1.00 1,00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 4.750 ft 1 0.448 0.370 1.00 1.300 1.00 1.00 1.00 1.00 1.00 1.34 524.30 1170.00 1.13 66.69 180.00 +D+0.750L 1.300 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 4.750 It 1 0.312 0.258 1.15 1.300 1.00 1.00 1.00 1.00 1.00 1.07 419.44 1345.50 0.90 53.35 207.00 +1.140D 1.300 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 4.750 ft 1 0.064 0.053 1.60 1.300 1.00 1.00 1.00 1.00 1.00 0.31 119.54 1872.00 0.26 15.20 288.00 +1.105D+0.750L 1.300 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 4.750 ft 1 0.230 0.190 1.60 1.300 1.00 1.00 1.00 1,00 1.00 1.10 430.45 1872.00 0.93 54.75 288.00 +0.60D 1.300 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 4.750 ft 1 0.034 0.028 1.60 1.300 1.00 1.00 1.00 1.00 1,00 0.16 62.92 1872.00 0.14 8.00 288.00 •1 i L�censee� .SO.UND STRUCTURAL;SOLUTIONS Load Combination Vex Stress Ratios Moment Values Shear Values Segment Length Span # M V C d C FN C i Cr Cm C t C L M fb Fb V fv Fv +0.460D 1.300 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 4.750 ft 1 0.026 0.021 1.60 1.300 1.00 1.00 1.00 1.00 1.00 0.12 48.24 1872.00 0.10 6.14 288.00 -- V@r'tiCai.ReictiorlS Support notation :Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 1.128 1.128 Overall MINimum 0.135 0.135 D Only 0.226 0.226 +D+L 1.128 1 A28 +0+0.750L 0.903 0.903 +0.60D 0.135 0.135 L Only 0.903 0.903 Wood Beam - Re=S:wobsts16Ls16OMl50BE-11WO1609-11_ENERC-1.EC6 ENERCALC, INC.1983-2016, Balld6.16.7.21, Ver:6.16.7.21 11 Description : 0-2 CODE REFERENCES Calculations per NDS 2015, IBC 2015, CSC 2016, ASCE 7-10 Load Combination Set : IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb - Tension 900.0 psi E : Modulus of Elasticity Load Combination i BC 2015 Fb - Compr 900.0 psi Ebend- xx 1,600.0 ksi Fc - Pdl 1, 350, 0 psi Eminbend - xx 580.Oksi Wood Species : Douglas Fir - Larch Fc - Perp 625.0 psi Wood Grade : No.2 FV 180.0 psi Ft 575.0 psi Density 31.20pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling - ---------- D(0.0133 L 0.0532 I L1 2x8 Span = 9.50 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load : D = 0.010, L = 0.040 ksf, Tributary Width =1,330 ft, (FLOOR) DESIGN SUMMARY, .._ ._. ..... ;Maximum Bending Stress Ratio = 0.6341 Maximum Shear Stress Ratio = 0.242 :1 Section used for this span 2x8 Section used for this span 2x8 fb : Actual = 685.08psi fv : Actual = 43.57 psi FB : Allowable = 1,080.00psi Fv : Allowable = 180.00 psi Load Combination +D+L Load Combination +D+L Location of maximum on span = 4.750ft Location of maximum on span = 0.000ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.129 in Ratio = 886>=360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.161 in Ratio = 708>=240. Max Upward Total Deflection 0.000 in Ratio = 0 <240.0 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V Cd C IN C i Cr Cm C t C L M fb Fb V fV Fv D Only 0.00 0.00 0.00 0.00 Length = 9.50 It 1 0.141 0.054 0.90 1.200 1.00 1.00 1.00 1,00 1.00 0.15 137.02 972.00 0.06 8.71 162.00 +D+L 1.200 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 9.50 ft 1 0.634 0,242 1.00 1.200 1.00 1.00 1.00 1.00 1.00 0.75 685.08 1080.00 0.32 43.57 180.00• +D+0.750L 1.200 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 9.50 ft 1 0.441 0.168 1.15 1.200 1.00 1.00 1.00 1.00 1.00 0.60 548.07 1242.00 0.25 34.86 207,00 +1.140D 1.200 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 9.50 ft 1 0.090 0,034 1.60 1.200 1.00 1,00 1.00 1.00 1.00 0.17 156.20 1728.00 0.07 9.93 288.00 +1.105D+0.750L 1.200 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 9.50 ft 1 0.325 0.124 1.60 1.200 1.00 1.00 1.00 1.00 1.00 0.62 562.45 1728.00 0.26 35.77 288.00 +0.60D 1.200 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 9.50 ft 1 0.048 0.018 1.60 1.200 1.00 1.00 1.00 1.00 1.00 0,09 82.21 1728.00 0.04 5.23 288.00 Description : 0-2 Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V C d C FN C i Cr CM C t C L M fb Fb V fv Fv +0.4601) 1.200 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 9.50 It 1 0.036 0.014 1.60 1.200 1.00 1.00 1.00 1.00 1.00 0.07 63.03 1728.00 0.03 4.01 288.00 VertfCal ReaG#IOiiS . Support notation : Far left is #7 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 0.316 0.316 Overall MINimum 0.038 0.038 D Only 0.063 0.063 +D+L 0.316 0.316 +D+0.750L 0.253 0.253 +0.601) 0.038 0.038 L Only 0.253 0.253 FOUNDATION ANALYSIS 6628 212th Street SW, Suite 205 - Lynnwood, WA 98036 - Ph: 425-778-1023 - Fax: 206-260-7490 FWS - FOUNDATION WALL STEM (BLD-A) Dead Live Snow Deck 15 40 25 Floor 10 40 Fnd ' 100 Roof 15 25 Wall 10 Bearing Capacity 2000 r gyY 1 � � r ZQ '—ors Arm iM"9!'YIY'Ay.p�F.;4SytgYrt4 MitifXif a!J`l iQ9MPAW YHA-fi. tiC9�lfM'ifPY r'iMHIM !1 f„ Tributary Dimension Type of Load Dead Load Live Load Snow Load Total Load 10 Roof 150 0 250 400 Floor 0 0 0 0 Wall 0 0 0 0 Fnd 0 0 0 0 Total 150 0 250 400 Minimum Ft Width USE (in) Stress 0.2 12 20%