Loading...
BLD20161468 Plan Review Comments - 2nd Review.pdf CE ITY OF DMONDS th •1215AN•E,WA98020 VENUE ORTH DMONDS P: 425.771.0220 • F: 425.771.0221 • W:www.edmondswa.gov HONEAXEB DSD:P•E•B EVELOPMENT ERVICES EPARTMENTLANNING NGINEERING UILDING May 26, 2017 Mr. Randy Munson Email: randy.munson@comcast.net ND RE: 2PLAN REVIEW COMMENTSFOR PLANCHECK #BLD20161468 TH NICHOLS/WONG RESIDENCELOCATED AT 9810 –235PL. SW Dear Mr. Munson: I have reviewed your resubmittal dated May 2, 2017 for the above building permit application for the Planning Division, and it was found that the following information, corrections, or clarifications will need to be addressed before review can continue: Setbacks: 1.Your response letter states that a fence was added to Sheet A-1; however, it appears that the fence wasadded to theadjacent property to the north, not the subject site. My previous comment related to fencing/landscapingwas regarding the requirement for a fence or row of plantings along the westernmost property line of the subject site. Please indicate the location and height of any existing fencing along the western property line that is to be retained and/or indicate any proposed fencing or vegetation in order to meet this requirement. 1/20/17 Comment: Acondition of the approval for the modification to the minimum required setback from the vehicular access easement was to maintaina 6-foot high fence and/or row of plantings along the western property lines of Lots 1 and 3. Please indicate the location of such fence and/or plantingson the site plan and indicate if any changes are proposed to what currently exists. Geotechnical Report: 2.Your response letter statedthat you would be submitting the geotechnical report withina couple of weeks; however, staff is still waiting for submittal of this report. Please submit this report for review by the Planning Division. 1/20/17 Comment: Due to the location of a Landslide Hazard Area on the western side of the subject site, a geotechnical report addressing the proposal’s compliance with all applicable critical areas regulations is required. Please note that the City’s critical areas regulations were updated in the spring of 2016 (Ordinance No. 4026), so your geotechnical engineer will need to address these updatedcode requirements.Please submit a report prepared by a qualified geotechnical engineer addressing all applicable requirements of ECDC Chapters 23.40 and 23.80. This includes, but is not limited to, theneed to specifically address the requirements of ECDC Sections 23.80.060 and 23.80.070 including an analysis of the design standards in 23.80.070.A.3.You provided a geotechnical report dated October 30, 2006 with your submittal; however, this report does not address the current code requirements and does not address the specific house plans for the subject site. Please submit twocopies of your revised site plan and two copies of any revised building plan sheets to a Development Services Permit Coordinator. Our office hours are Mondays, Tuesdays, Thursdays, and Fridays between 8:00am and 4:30pm, and Wednesdays between 8:30am and noon.If you have any questions, feel free . to contact me at (425) 771-0220or Jen.Machuga@edmondswa.gov Sincerely, Development Services Department -Planning Division JenMachuga Associate Planner