BLd20161506.pdf�)FElla/
December 6, 2016
CITY OF EDMONDS
DEPARTMENT OF FIRE PREVENTION
MEMORANDUM
To: Kenneth Bellingham
edrnondsbaker y cow m ast. net
From: Kevin Zweber, Fire Marshal
Subj: Edmonds Bakery 418 Main Street, Edmonds, Bld20161506
In reference to your building permit application, the following comments are provided
specific to the West section (restaraunt) please indicate on the plans:
- Because of the occupant load, the second existing exit is required. Change the two
rear exit doors so they swing outward.
-Provide yellow striping on the floor between the two rear doors, 44" wide. Label floor,
"KEEP CLEAR, NO STORAGE, FIRE EXIT".
-Provide an illuminated exit sign with egress lighting above the second door opening to
the exterior. It appears one is already present on the first door.
-Provide panic hardware on the two rear exit doors (IFC 1010.1.10)
Please let me know if you have any questions.
Kevin Zweber
Deputy Chief — Fire Marshal
425-771-0213