Loading...
Bld20161665 Consultant Notes.pdfFIRST IREVV.N EArnoinds Review #. BLD203.6-1665 WC 3 Project #� 217 -Ell W-001 Jainuary 23, 2017 Plan Review Comments Project Name: Point Edwards BLDG 10 — Fire Sprinkler Submittal Fire Review By: Chris Kimball Location(s): 50 Pine Street, Edmonds, WA Checked By: Marty Gillis Date of Comments: 01/23/2017 GENERAL INFORMATION: The plans and other submittal documents for the above-mentioned project have been reviewed. The following comments address areas of concern, non-compliance with the governing code, potential errors, or omissions in the proposed design. The appropriate design professional must address each comment below and submit a written response in addition to revised plans and calculations if necessary. Please cloud any revisions made to the construction drawings and provide the date of the latest revision on each revised sheet. FIRE REVIEW COMMENTS: F1. The review performed by our office is in regards to the fire sprinkler submittal only. A general building and fire review was previously performed by the City of Edmonds to ensure compliance with both the IBC and IFC. F2. There is a significant amount of information missing from the plans submitted as required by Section 23.1.3 of NFPA 13. Please provide the following... A. The plans do not specify the locations of fire -rated walls or horizontal assemblies (Item #6, §23.1.3). This must be shown and listed penetrations should be specified in accordance with IBC 714. B. While the locations of hangers have been noted and details provided, the type of anchor for attaching these hangers to the wood framing members has not been specified (Item #22, §23.1.3). C. The kind and location of alarm bells has not been specified (Item #26, §23.1.3). D. The flushing provisions have not been specified (Item #29, §23.1.3). E. No information regarding a backflow preventer has been provided (Item #41, §23.1.3). F. The edition of NFPA 13 used in design is not specified (Item #46, §23.1.3). F3. Please note on the plans that SureFire Sprinkler Corporation will provide a completed contractor's material and test certificate(s) to the City as required by Section 212-80-088 of the Washington Administrative Code (WAC). F4. Please clarify on the plans how the spare sprinkler requirements of Section 6.2.9.1 of NFPA 13 will be met. �........... L �� of � �� WC Project t 217-IEDIM.-OO1 January 23, 2017 F5. Please note the "clearance" requirements for piping passing through walls and floors as required by Section 9.3.4 of NFPA 13. F6. From the section view provided on sheet 2 it appears that the roof might be accessible. If this is the case and persons will have access to the roof please provide a standpipe connection at the roof per IBC 905.3.8. F7. Please clarify on the plans how valve supervision will be provided per IBC 905.9. F8. Please confirm that concealed spaces that may require sprinkler protection do not exist (see Section 23.1.3, Item #8 of NFPA 13). F9. Please clarify the branch line restraint requirements on the plans in accordance with Section 9.3.6 ofNFPA 13. F10. Please clarify on the plans that all areas where the wet sprinkler system will be provided shall be maintained above 40°F as required by Section 8.16.4 of NFPA 13. F11. While the water supply information is noted on the plans, it does not state the name of the person who conducted the test and the date per Section 23.2.1 of NFA 13. F12. Please confirm that the main drain discharges outside or to a drain capable of handling the flow as required by Section 8.16.2.4.4 of NFPA 13. F13. The hydraulic calculations for the garage level appear to consider a wet pipe system while a dry pipe system is specified. Please coordinate. F14. Please clarify on the plans how the air supply for the dry pipe system will meet the requirements of Section 7.2.6 of NFPA 13. F15. Material data was only provided for the sprinkler heads. Please provide material data for all piping, fittings, valves, test connections, sway bracing, hangars, etc. as required by NFPA 13. F16. Please provide a hydraulic design information sign as required by Section 25.5 of NFPA 13. Should you have any inquiries regarding this letter, please contact Chris Kimball (chrisk@wc-3.com) via email or call (801) 682-5031. [END] Page 3 of 3