Loading...
BLD20161717 - 9333 234th St SW - Geers - Stormwater Review - Cat 1 Small.pdfStormwater Review Date of Review: January 26, 2017 File/Address:BLD20161717 / 9333 234h St SW Reviewer: Robcrt C. Edwards, PE, Stormwater Engineer, City of Edmonds Background This is classified as a Category I Small Site Project because it creates/adds impervious area more than 2,000 SF and less than 5,000 SF. Category I Small Site Projects arc su�jcct to Small Site Minimum Requirements 1, 2, 3, 4, and 5 Minimum Requirement #1 — Preparation of Stormwater Site Plan Comments: I . 6" PVC to rain garden has insufficient cover 2. 6" PVC outlet IE is shown as 379, 20 LF g 5% the inlet IE calculates to 380. This is above grade at the house. 3. Driveway has conflicting drain arrows, IE 4% to the east and unspecified grade to the south. 4. Foundation drains are not shown. If connecting to rain garden, sufficient fall is required and rain garden will need to be upsized to accommodate foundation drain. Minimum Requirement #2 — Construction Stormwater Pollution Plan Comments: 1. Provide rock construction entrance. 2. Grading plans depicts gradmig across proposed rain garden. Ensure that no heavy equipment may drive over proposed rain garden. Minimum Requirement #3 — Source Control of Pollution Comments: N/A per SFR Minimum Requirement #4 — Preservation of Natural Drainage Systems Comments: N/A per LID Minimum Requirement #5 — Onsite Stormwater Management Comments: 1. Small Scale PIT: Provide 15-minute records per DOE SWMMWW. Minimum Requirement #7 — Flow Control Comments: Flow control by LID Minimum Requirement #8 — Wetland Protection Comments: N/A Minimum Requirement 49 — Operation and Maintenance Comments: None Minimum Requirement 411 — Financial Liability Comments-. N/A for SFR