Loading...
BLD20161717_Geers_ENG3.pdf CITY OF EDMONDS PLAN REVIEW COMMENTS ENGINEERING DIVISION (425) 771-0220 City Website: www.edmondswa.gov DATE:June 21, 2017 TO:Jeff Geers jeffgeers@outlook.com FROM:Mitch Boyd,Stantec Consulting Services Mitch.Boyd@edmondswa.com RE:Application #: bld20161717 Project: Geers-Single Family Residence th Project Address: 9401 234St SW(Parcel #27033600109800) During review of the above noted application, it was found that the following information, corrections,or clarifications are needed. Reviews by other divisions, such as Planning, Building, or Fire may result in additional comments.Please submit three (3) sets of revised plans/documents with a response letter addressingeach of the items below. nd Resubmittals can be made at the Development Services Department on the 2floor of City Hall. Permit Center hours are M, T, Th & F from8am-4:30pmand on Wednesdays from 8:30am-noon. City of Edmonds handouts, standard details and development code can be referenced on the City website; edmondswa.gov. Sheet 1 of 3 –SITE PLAN, & DRAINAGE 1)Per the grading plan, runoff from the driveway willnot sheet flow to the transition zone to the south. Instead, runoff will enter the garage. Please revise the grading plan so runoff is routed south. 2)Per the grading plan, the transition zone flows uphill. Please revise. 3)The sewer cleanout at the property line needs to be within private property. Add a note to this cleanout that it shall have a 12” cast iron lamphole cover with ½” hexbolts. ADDITIONAL COMMENTS 1)North arrows have not been provided on the plan set. Please provide. 2)Ensure that all required documentation is provided for permitting.