Loading...
BLD20170068-Nielsen-Retaining Wall - E1.pdf CITY OF EDMONDS PLAN REVIEW COMMENTS ENGINEERING DIVISION (425) 771-0220 City Website: www.edmondswa.gov DATE:May 16, 2017 TO:Timothy Huntting Nelson Geotechnical Associates, Inc timh@nelsongeotech.com FROM:Mitch Boyd,Stantec Consulting Services Mitch.Boyd@edmondswa.gov RE:Application #: BLD20170068 Project: Niesel –Retaining Wall Project Address: 18500 Olympic View Drive During review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Reviews by other divisions, such as Planning, Building, or Fire may result in additional comments. Please submit two (2)sets of revised plans/documents including a written response to each item below. nd Resubmittals can be made at the Development Services Department on the 2floor of City Hall. Permit Center hours are M, T, Th & F from 8am-4:30pmand on Wednesdays from 8:30am-noon. City of Edmonds handouts, standard details, application and other forms, and development code may be referenced on the City website: www.edmondswa.govunder Services/Permits and Development. SITE PLAN 1)Include construction sequence. Refer to sample on City website. 2)Show filter fence on the plans and incorporate and referenceCity standard detail E1.1. 3)It appears the constructionentrance shown is not accessible as the neighboring house blocks the entrance. Please relocate the construction entranceand incorporate and referenceCity standard detail E1.2.If the existing driveway is to be used, elaborate on how construction stormwater will be mitigated. 4)Pleaseadd a note to the plans that filter socks will be added to any catch basins downstream from the construction site.Incorporate and reference City standard detail E1.3. 5)Please add a note to theplans that all disturbed soils will be compost amendedper BMP T5.13. 6)Add note: Install and maintain all TESC measures according to approved plans, City of Edmonds standard details, and all other measures that may be required during construction. 7)The plans do not denote a footing drain for the retaining walls. If footing drains are to be installed, please include them in the retaining wall detailand show the discharge location.