BLD20170068-Nielsen-Retaining Wall - E1.pdf
CITY OF EDMONDS
PLAN REVIEW COMMENTS
ENGINEERING DIVISION
(425) 771-0220
City Website: www.edmondswa.gov
DATE:May 16, 2017
TO:Timothy Huntting
Nelson Geotechnical Associates, Inc
timh@nelsongeotech.com
FROM:Mitch Boyd,Stantec Consulting Services
Mitch.Boyd@edmondswa.gov
RE:Application #: BLD20170068
Project: Niesel –Retaining Wall
Project Address: 18500 Olympic View Drive
During review of the above noted application, it was found that the following information,
corrections, or clarifications are needed. Reviews by other divisions, such as Planning, Building, or
Fire may result in additional comments. Please submit two (2)sets of revised plans/documents
including a written response to each item below.
nd
Resubmittals can be made at the Development Services Department on the 2floor of City Hall.
Permit Center hours are M, T, Th & F from 8am-4:30pmand on Wednesdays from 8:30am-noon.
City of Edmonds handouts, standard details, application and other forms, and development code
may be referenced on the City website: www.edmondswa.govunder Services/Permits and
Development.
SITE PLAN
1)Include construction sequence. Refer to sample on City website.
2)Show filter fence on the plans and incorporate and referenceCity standard detail E1.1.
3)It appears the constructionentrance shown is not accessible as the neighboring house blocks
the entrance. Please relocate the construction entranceand incorporate and referenceCity
standard detail E1.2.If the existing driveway is to be used, elaborate on how construction
stormwater will be mitigated.
4)Pleaseadd a note to the plans that filter socks will be added to any catch basins downstream
from the construction site.Incorporate and reference City standard detail E1.3.
5)Please add a note to theplans that all disturbed soils will be compost amendedper BMP
T5.13.
6)Add note: Install and maintain all TESC measures according to approved plans, City of
Edmonds standard details, and all other measures that may be required during construction.
7)The plans do not denote a footing drain for the retaining walls. If footing drains are to be
installed, please include them in the retaining wall detailand show the discharge location.