Loading...
BLD20170071 (2)OV ED41 CITY OF EDMONDS 121 5TH AVENUE NORTH -EDMONDS, WA 98020 PHONE: (425) 771-0220 - FAX: (425) 771-0221 STATUS: ISSUED 02/13/2017 Pennit#: BLD20170071 BUILDING PERMIT Expiration Date: 08/14/2017 Project Address: 24025 74TH AVE W, EDMONDS Parcel No: 00488800701000 I . I . 1, X1 I "1 9 9 m [4�� mmurm gmv�� FENG LIN FENG LIN RESOLUTION PLUMBING 18230 E VALLEY HWY STE 129 18230 E VALLEY HWY STE 129 C/O SAMUEL SCILLEY KENT, WA KENT, WA 6704 49TH PL NE MARYSVILLE, WA 98270 (206) 778-8714 (425) 320-6975 LICENSE #: RESOLP * 844NR EXP:08/19/2018 STAND ALONE FIRE SPRINKLER SYSTEM FOR NEW SFR VALUATION: $0.00 PERMIT TYPE- Residential PERMIT GROUP: 30 - Fire Sprinkler GRADING: N CYDS 0 TYPE OF CONSTRUCTION RETAININGWALL ROCKERY: OCCUPANT GROUP: OCCUPANT LOAD FENCE: 0 X 0 FT.) CODE 2015 OTHER - ------- OTHER DESC: ZONE: NUMBER OF STORIES: 0 VESTED DATE: NUMBER OF DWELLING UNITS 0 LOT LXISIING AREA BASEMENT - 0 1 ST FLOOR: 0 2ND FLOOR: 0 PROPOSED ARFA IBASEMENT: 0 1 ST FLOOR: 0 2ND FLOOR 0 3RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0 13 RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0 BEDROOMS: 0 BATHROOMS: 0 IBEDROOMS: 0 BATHROOMS: 0 FRONTSErBACK SIDESErBACK REARSEIFBACK REQUIRED: PROPOSED: — 7ZREQUIRED: PROPOSED: IREQUIRED: PROPOSED: HEIGHT ALLOWED:O PROPOSED:O IREQUIRED: PROPOSED SETBACK NOTES: I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOINGTHE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING, To WORKMEN'S COMPENSATION INSURANCE AND RCW 18:27� IS APPLIVATIQN IQ,,)iOT A PERMIT UNTIL SIGNEDBY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. Print Released By �71131,7_017 Date ATTENTION IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL ORA CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. UBC109/ IBCJ 10/ IRCI 10. ONLINE APPLICANT ASSESSOR .'w_R STATUS: ISSUED BLD20170071 • Final approval on a project or final occupancy approval must be granted by the Building Official prior to use or occupancy of the building or structure. Check thejob card for all required City inspections including final project approval and final occupancy inspections. • Any request for alternate design, modification, variance or other administrative deviation (hereinafter "variance") from adopted codes, ordinances or policies must be specifically requested in witing and be called out and identified. Processing fees for such request shall be established by Council and shall be paid upon submittal and are non-refundable. • Approval of any plat or plan containing provisions which do not comply with city code and for which a variance has not been specifically identified, requested and considered by the appropriate city official in accordance with the appropriate provision of city code or state law does not approve any items not to code specification. • SoundiNoise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:00arn to 6:00prn on weekdays and I 0:00arn and 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites /activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. • Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold harrnless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of whatever nature, aris ing directly or indirectly from the issuance for this perrait. Issuance of this pen -nit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCT10N ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT TIME LIMIT SEE ECDC 19.00.005(A)(6) - --T CALL FOR INSPECTIONS FIRE (425) 775-7720 BUILDING (425) 771-0220 57 13-33 ENGINEERING (425) 771-0220 EXT. 1326 1 I PUBLIC WORKS (425) 771-0235 1 PR&TREATMENT (425) 672-5755 1 RECYCLING (425) 275 86�1 When calling for an inspection please leave the folloming information: Permit Number, Job Site Address, Type of Inspection being requested, Contact Name and Phone Number, Date Prefereed, and v�fiether you prefer morning or afternoon. • F-Fire Sprinkler Insulation • F-Fire Sprinkler Bucket Test • F-Fire Spfinlder Acceptance X /X DEVELOPMENT SERVICES RESIDENTIAL BUILDING PERMIT APPLICATION h 121 5' Avenue N, Edmonds, WA 98020 City of Edmonds Phone 425.771.0220 2 Fax 425.771.0221 PLEASE REFER TO THE RESIDENTIAL BUILDING CHECKLIST FOR SUBMITTAL REQUIREMENTS P OJECT ADDRESS (Atreet, Suite # City State, Zip): N_&,�!� Parcel #: Subdivision/Lot Project Valuation: $ APPLICANT: Er= :, A IG /t/ Phone: 9,76 'Jj� �1/4"77 Address (Street, Ci y tate, Zip): i & - 4! �_- - M q- /X E-Mail Address: q,/,0.V . P R 0! � �glld Phone: FaV Address (Street, City, State, Zip): E-Mail Address: `1� AGENCY: Phone: Fax: (Street, City, State, Zip): E-Mail Address: CONTRACTOR:* Phone: 77— Address (Street, City, State, Zip): E-Mail Address: *Contractor must have a valid City of Edmonds business license prior to doing work in the City. Contact the City Clerk's Office at 425.775.2525 WA State Li se #/Exv. Qate: TJ '9 Pr_-soLP AAiA/,k City Business License #/Exp. Date: DETAIL THE SCOPE OF WORK: 1_9" fbk, PROPOSED NEW SQUARE FOOTAGE FOR THIS PROJECT: Basement: sq. ft. Select Basement Type: Finished L] Unfinished LJ V Floor: sq. ft. Garage/Carport: sq. ft. 2 n' Floor: sq. ft. Deck/Cvrd Porch/Patio: sq. ft. Bedrooms # Full-3/4 Bath # Half -Bath # '5ther: sq. ft. Fire Sprinklers: Yes L No 0 1 Retaining Wall: Yes E] No Grading: Cut —cu. yds. Fill cu.yds. I Cut/Fill in Critical Area: Yes L No L I declare under penalty ofperjury laws that the information I have provided on this formlapplication is true, correct and complete, and that I am the property owner or duly authorized agent of the property owner to submit a permit application to the City of Edmonds. Print Name: 6,Y% Owner 1� Agent/Other (specify): Signature: I Date: a/g 12 I 2LJ� VX J I I - FORM A LTuilding New Folder 201 A4 & x-ferred to L-Building-New drive\Form A2014.docx Updated: 1/17/2014 R 0 liable Specifically Listed for use in Multipurpose Systems that serve both domestic water and fire protection. Sprinkler Type Residential Flat Concealed Sprinkler listed for a minimum design density of .05 gpM/ft2 with It potable water". * Model RFC30 LL * Model RFC43 LL * Model RFC49 LL Features 1 . National Sanitation Foundation (NSF) Cer- tified to NSF/ANSI Standard 61 Annex G (Less than 0.25% Lead content). 2. Very low water flow requirements. 3. Cover plate attachment (Plain or Perforated) with 112" (13mm) total adjustment 4. Thread-on/off or Push-on/off cover attach- ment option. 5. Smooth Aesthetic ceiling profile. 6. Available in white, brass, chrome and black plated or custom painted finishes. Patent Pending Listing & Approvals 1. Listed by Underwriters Laboratories, and certified by UL for Canada (cULus) 2. NSF Cerified to NSF/ANS1 Standard 61 Annex G Product Description Model RFC30 LL, RFC43 ILL and RFC49 LL Concealed Residential Sprinklers are fast response residential fusible solder link automatic sprinklers. Residential sprinklers dif- fer from standard sprinklers primarily in their response time and water distribution patterns. Model RFC30 LL, RFC43 LL and RFC49 LL sprinklers discharge water in a hemi- spherical pattern below the sprinkler deflector Residen- tial distribution patterns are higher and generally contain Bulletin 032 Rev. C Model RFC30 LL (SIN RA321 1) Model RFC43 LL (SIN RA3212) Model RFC49 LL (SIN RA3216) Residential Flat Concealed Sprinklers Perforated Cover Plate a finer droplet size than standard sprinkler patterns. The combination of speed of operation and high discharge pat- tern required for residential sprinklers has demonstrated, in fire testing, an ability for controlling residential fires, and thereby providing significant evacuation time for occu- pants. The RFC30 LL, RFC43 LL and RFC49 ILL Sprinklers provide the best form of fire protection by combining an at- tractive appearance and 1/2" (13mm) of cover adjustment for ease of installation. The small diameter cover plate is easily and positively attached and blends into the ceiling, concealing the most dependable fire protection available, an automatic sprinkler system. The RFC30 LL, RFC43 LL and RFC49 LL are UL Listed and NSF Certified Residen- tial Sprinklers to be installed in the residential "potable" water applications of any occupancy in accordance with NFPA 13, 13R, & 13D and meets all applicable low lead standards, .25% or less. The cover plate adjustability of the RFC30 LL, RFC43 LL and RFC49 LL can reduce the need for precise cutting of drop nipples. The threaded cover plate assembly can be adjusted without tools to fit accurately against the ceiling. The fire protection system need not be shut down to adjust or remove the cover plate assembly. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 0 W N) M CD X Application and Installation For use in fire sprinkler systems that also supply potable water to a plumbing flxturd or fixtures. The RFC30 LL, RFC43 LL and RFC49 LL, for residential installa- tions, use a 165F (74PQ fusible solder link in a tuning fork style sprin- kler tame with a drop -down deflector This assembly is recessed into the ceiling and concealed by a flat cover plate. The cover plate is attached to the skiq, using 135F (57C) ordinary temperature clas- sification solder When the ceiling temperature rises, the solder hold- ing the cover plate releases the cover alIDAlingthedeflector to drop into position and exposing the Sprinkler inside to ceiling temperature. The subsequent operation of the solder link opens the waterway and causes the deflector to drop into position to distribute the discharging water in a hemispherical pattern below the sprinkJer deflector. Any adjustment of thread engagement between the cover plate and cup will assure that the drop -down deflector is properl'y located below the ceiling. The residential distribution pattern contains a finer droplet size tan a standard sprinkler and the pattern produces significantly higherwallwetting. After a 211,," inch diameter hole is cut in the ceiling, the splinkler is to be installed with the Model FC Wrench. Installation Data: When installing a Sprinkler, the wrench is first positioned into the sprinkler/cup assembly and around the hexagonal body of the sprin- Her frame. The wrench must boftom out against the cup in order to ensure proper, safe installation. The spdnkler is then tightened into the pipe fitting. When inserl:ing or removing the wrench from the sphnkJer/cup assembly, care should be taken to prevent damage to the sprinkler DO NOT WRENCH ON ANY OTHER PARTOF THE SPRINKLER /CUP ASSEMBLY. MODELRFC30LL, RFC43LLAND RFC49 LL CONCEALED SPRINKLERS MUST BE INSTALLED ONLY WITH 135OF RATED COVERS. Note: A leak tight 112" NFIT (191/2) sprinkler joint can be obtained with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m). Do not tighten sprinklers over maximum recommended torque, It may cause leakage or irn- pairment of the sprinklers. Cover assemblies provide up to 1/2" (13mm) of adjustment. Turn the cover clockwise until the flange is in contact with the ceiling. For the push-onAhread-off option, the cover assembly is pushed onto the cup and final adjustment is made by turning the cover clockwise unt- til the skirt flange makes full contact with the ceiling. Cover removal Model (SIN) Thread Size Inch (mm) Nominal Orifice Inch (mm) Sprinkler Temp Rating CCP Assembly Temp. Rating max. Ambient Temp. K Factor Max. Pressure psi(bar) OF I OC OF Oc OF Oc RFC 30 LL (RA321 1) 112" (15) 21/64(8.2) 165 74 135 57 100 38 3.0(43.2) 175(12) RFC 43 LL (RA3212) 1/2" (15) 3/,(10) 165 74 135 57 100 38 4.3(62) 175(12) RFC 49 LL (RA3216) 1 1/2" (15) 1 '/16 (11) 165 74 135 57 100 38 1 4.9(70.6) 175(12) Note: 1 bar = 100 Kpa RFC 30 LL Max. Coverage Ordinary Temp. Rating Top of Deflector minimum area Max. Spacing (1650 40C) to Ceiling Installation Spacing Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Type Ft (m) GPM (Umin) PSI (bar) 12 x 12 (3,6 x 3,6) 12(3,6) 9(34,1) 9.0(0,62) Smooth Ceilings 112 to 1 (13 to 25.4) Beamed Ceilings per NFPA 13D, 13R or Concealed 8(2,4) 14 x 14 (4,3 x 4,3) 14(4,3) 10(37,8) 11.0(0,76) , 13 installed in beams 112 to 1(13to 25.4) , I For Ceiling types refer to NFPA 13, 13R or 13D RFC 43 LL Max. Coverage Ordinary Temp. Rating Top of Deflector Minimum area Max. Spacing (1650 40c) to Ceiling Installation Spacing Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Type Ft (m) 12 x 12 (3,6 x 3,6) 12(3,6) 12(4,5) 7.8(0,54) Smooth Ceilings 1/2 to 1 (13 to 25.4) 14 x 14 (4,3 x 4,3) 14(4,3) 13(49) 9.1(0,63) 16 x 16 (4,9 x 4,9) 16(4,9) 13(49) 9.1(0,63) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams 112 to 1 (13 to 25.4) Concealed 8(2.4) 18 x 18 (5,5 x 5,5) 18(5,5) 18(68) 17.5(1,21) 20 x 20 (6,1 x 6, 1) 20(6,1) 21(79) 23.8(1,64) For Ceiling types refer to NFPA 13, 13R or 13D RFC 49 LL Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (1650 40c) Top of Deflector to Ceiling Inch (mm) Installation Type Minimum Spacing Ft (m) Flow GPM (Umin) Pressure PSI (bar) 12 x 12 (3,6 x 3,6) 12(3,6) 13(49) 7.0(0,48) Smooth Ceilings 1/2 to 1 (13 to 25.4) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams 112 to 1 (13 to 25.4) Concealed 8(2,4) 14 x 14 (4,3 x 4,3) 14(4,3) 13(49) 7.0(0.48) 16 x 16 (4,9 x 4,9) 16(4,9) 13(49 7.0(0,48) 18 x 18 (5,5 x 5,5) 18(5,5) 17(64,3) 12.0(0,83) 20 x 20 (6,1 x 6,1) 20(6,1) 20(75,73) 16.7(1,14) For Ceiling types refer to NFPA 13, 13R or 13D 2. requires turning in the counter -clockwise direction. In ceilings that have a plenum space above the sprinider, the pienum space may have neutral or negative pressurbation but must not be positively pressi . Inspect all spdnlders after installation to ensure that the gap between the cover plate and ceiling and the 4 slots in the cup are all open and free from any air flow impe& menL Maintenance Model RFC30 LL, RFC43 LL and RFC49 ILL Concealed Sprinklers should be inspected quarterly and the sprin- kler system maintained in accordance with NFPA25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler cover plate as- sembly which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non -operation. Model RFC30 LL, RFC43 LL and RFC49 LL Residential Concealed Sprinkler Specification Sprinklers shall be cULus Listed and NSF-61 Annex G certified low flow residential concealed sprinklers with drop - down deflector and adjustable flat cover plate engineered for a minimum design density of 0.05gpM/ft2. Sprinkler frame and deflector shall be of bronze frame construction having a 112" NPT thread. Thermal element shall consist of an approved black - painted beryllium -nickel fusible solder link with symmetric lever mechanism, maintaining a Teflon -coated Belleville spring washer and machined brass cap water seal assem- bly containing no plastic parts. Sprinkler K-factors shall be a nominal 3.0 (43.2), 4.3 (62) and 4.9 (70.6), having a 3/8" 1 112" REDUCING 7EE OR ELBOW HI_ 2J" [58.42MM] DIA CUP � CEILING [12.70-mj MA. COVER ADJUSTMENT CC , COVER PIATEJ ASSEMBLY 4" [84.21-] DIA. Specify: 1. Sprinkler Model 2. Cover Plate Finish 3. Thread -On or Push -On Feature 2p 156_55­,J HOLE IN CEILING 2" [50.8-] MAX FACE OF FITTING TO FACE OF CEILING DIMENSION J- [4,96-1 X6FG0M COVER PLATE 112" L12.7mml ADJUSTMENT and '/16" orifice respectively, Temperature rating shall be Ordinary 165'F (74'C); cover plate temperature rating to be 135'F (57C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange allow- ing a 112" cover plate adjustment. Any secure engagement between the cover plate and the cup will assure that the drop -down deflector is properly located below the ceiling. A plastic protective cap shall be provided and factory in- stalled inside the sprinkler cup to protect the drop -down sprinkler deflector from damage, which could occur during construction before the cover plate is installed. Standard cover finish: [Chrome] [White] [Specialty — specify]. Resi- dential concealed sprinklers shall be Reliable Model RFC30 LL, SIN RA3211 (Bulletin 032), RFC43 LL, SIN RA3212 (Bul- letin 032) or Model RFC49 LL, SIN RA3216 (Bulletin 032). Ordering Information Cover Plate Finishes0) Standard Finishes Chrome White Paint Special Application Finishes(2) Bright Brass Finished Bronze Black Plating Black Paint Off White Satin Chrome Other finishes and colors are available on special order. Consult factory for details. Coverplate custom paint is semi -gloss, unless specified otherwise. For the perforated style cover - plate, consult factory for avail- ability on these and other cus- tom finishes. 1 "Moft 3 3. uponof Uponor AquaPEXO White Submittal Information Revision C: Oct. 7, 2009 Project Information Job Name: Location: Part No. Ordered: Enaineer: Date Submitted: Contractor: Submitted By: Manufacturer's Representative: Approved By: Technical Data Material: Crosslinked polyethylene PEX-a Engel Method; PEX 5006 Standard Grade Hydrostatic 200OF (930C) at 80 psi Ratings (PPI): 180OF (820C) at 100 psi 73.40F (230C) at 160 psi 1/2", 3/4", and 1" AquaPEXO White only: 1201F (490C) at 130 psi Linear Expansion Rate: 1.10"/100F (12-C)/100' Product Information and Application Use Uponor AquaPEX White is tubing used for hot and cold domestic potable water distribution, residential fire safety and radiant heating systems containing no ferrous corrodible components or where ferrous COMDonents are isolated from the tubina. V Description Part Number 1. D. (A) O.D. (B) Weight 1/4 " Uponor AquaPEX White, 100-ft. coil F1040250 0.241" 0.375" 4.0 lbs. 3/a" Uponor AquaPEX White, 400-ft. coil F1090375 0.350" 0.500" 20.0 lbs. 3/8" Uponor AquaPEX White, 1,000-ft. coil F1120375 0.350" 0.500" 44.0 lbs. 1/2 " Uponor AquaPEX White, 100-ft. coil* F1040500 0.475" 0.625" 6.0 lbs. 1/2 " Uponor AquaPEX White, 300-ft. coil* F1060500 0.475" 0.625" 18.0 lbs. 1/2 " Uponor AquaPEX White, 1,000-ft. coil* F1120500 0.475" 0.625" 54.0 lbs. 5/8 " Uponor AquaPEX White, 300-ft. coil F1060625 0.574" 0.750" 28.0 lbs. s/. " Uponor AquaPEX White, 1000-ft. coil F1120625 0.574" 0.750" 86.0 lbs. 3/4 " Uponor AquaPEX White, 100-ft. coil* F1040750 0.671" 0.875" 10.0 lbs. 3/4" Uponor AquaPEX White, 300-ft. coil* F1060750 0.671" 0.875" 34.0 lbs. 3/4" Uponor AquaPEX White, 500-ft. coil* F1100750 0.671" 0.875" 54.0 lbs. 1" Uponor AquaPEX White, 100-ft. coil* F1041000 0.862" 1. 125" 20.0 lbs. 1" Uponor AquaPEX White, 300-ft. coil* F1061000 0.862" 1.125" 56.0 lbs. 1" Uponor AquaPEX White, 500-ft. coil* F1101000 0.862" 1.125" 93.0 lbs. 11/4" Uponor AquaPEX White, 100-ft. coil F1061250 1.054" 1.375" 34.0 lbs. 11/4" Uponor AquaPEX White, 300-ft. coil F1021250 1.054" 1.375" 106.0 lbs. 11/2" Uponor AquaPEX White, 100-ft. coil F1061500 1. 244 " 1.625" 44.0 lbs. 11/2" Uponor AquaPEX White, 300-ft. coil F1021500 1. 244 " 1.625" 133.0 lbs. 2" Uponor AquaPEX White, 100-ft. coil F1062000 1.629" 2.125" 68.2 lbs. 2" Uponor AquaPEX White, 200-ft. coil F1052000 1.629" 2.125" 136.4 lbs. 2" Uponor AquaPEX White, 300-ft. coil F1022000 1.629" 2.125" 204.6 lbs. 3" Uponor AquaPEX White, 100-ft. coil F1063000 2.400" 3.125" 128.0 lbs. 3" uponor AquaPEX White, 350-ft. coil F1023000 2.400" 3.125" 442.0 lbs. Installation Approved fittings are ProPEXO fittings' for sizes 3/8" throrph 2" AquaPEX. Use WIPEXTM fittings for 3" AquaPEX. Refer to the AquaPEX Professional Plumbing Installation Handbook, AquaSAFE T Fire Safety Installation Guide or the Uponor Radiant Installation Handbook for details Standards Codes Listings CSA B137.5; ASTM F876; ASTM IPC; UPC; -1/2", 3/4", 1" UL 1821; *ULC/ORD - C 199 P; IAPMO; CSA; HUD; WARNOCK HERSEY; NSF; F877; ASTM F1960; ASTM-E84; NSPC;NPC ITS; UL; ICC; ANSI/NSF 14- and 61-certified; CAN/ULC S102.2; U.S.: 3/4" diameter and ASTM-E119/UL 263 of Canada smaller; Canada: 1" diameter and smaller Related Applications Contact Information PEX-a Plumbing Systems Uponor, Inc. Uponor Ltd. AquaSAFE Fire Safety Systems 5925 148th Street West 2000 Argentia Rd., Plaza 1, Ste. 200 Apple Valley, MN 55124 USA Mississauga, ON L5N 1WI CANADA Phone: (800) 321-4739 Phone: (888) 994-7726 Fax: (952) 891-2008 Fax: (800) 638-9517 www.uponor-usa.com www.uponor.ca ProPEXO is a registered trademark of Uponor, Inc. ProPEX- is a trademark of Uponor Ltd. ProPEXP Ring Submittal Information Revision A: March 17, 2009 Project Information Job Name: uponof Location: Part No. Ordered: Engineer: Date Submitted: Contractor: Submitted By: Manufacturer's Representative: Approved By: Technical Data Material: Density: PEX-a (Engel Method) 926 to 940 kg/M3 Degree of Crosslinking: 70% to 89% Product Information and Application Use Manufactured from PEX-a material, Uponor ProPEXQD Rings are required to make a proper ProPEX connection.' Red print on the rings indicates hot lines. The 1/2" and 3/4" ProPEX rings with stop includes a leading edge chamfer and stop edge. Description ProPEX Ring, 3/a" ProPEX Ring with Stop, 1/2" (red print) ProPEX Ring with Stop, 1/2" ProPEX Ring, 5/8" ProPEX Ring with Stop, 3/4" ProPEX Ring, I" ProPEX Ring, 11/4" ProPEX Ring, 11/2" ProPEX Ring, 2" Installation Part Number Length i.d. o.d. Weight Q4690302 0.54" 0.49" 0.74" 0.005 lbs. Q4690511 0.63" 0.63" 0.87" 0.006 lbs. Q4690512 0.63" 0.63" 0.87" 0.006 lbs. Q4680625 0.79" 0.75" 1.001, 0.008 lbs. Q4690756 0.87" 0.881, 1.13" 0.012 lbs. Q4681000 1.101, 1.13" 1.42" 0.020 lbs. Q4681250 1.35" 1.38" 1.66" 0.030 lbs. Q4681500 1.61" 1.63" 1.911, 0.040 lbs. Q4682000 1.97" 2.14" 2.61" 0.133 lbs. Square cut the Uponor ProPEX tubing. Remove excess material. Slide the ProPEX Ring over the end of the tubing (maximum 'Ile' over -hang). When using the 1/2" ProPEX Ring with stop edge, slide the ring on (i.e., chamfered edge first) until the end of the tubing contacts the stop edge. Expand tubing and ring. Rotate tool a quarter turn after each expansion to prevent the formation of grooves. Remove the expansion tool and fully seat the tubing and ring against the shoulder of the fitting. You should make ProPEX connections at temperatures above 50F /-150C. For more information, refer to the AquaPEX8 Professional Plumbing Installation Handbook, AQUASAFEO Fire Safety Installation Guide or the Uponor Radiant Installation Handbook. Standards ASTM F1960 Codes IPC; UPC; NSPC; NPC of Canada Listings UL 1821 (1/2", 3/4" and J."); ULC/ORD - C 199 P (1/2", 3/4" and 1"); HUD MR 1269; ICC ESR 1099; ANSI/NSF 14- and 61-certified Related Applications Contact Information PEX-a Plumbing Systems Uponor, Inc. Uponor Ltd. Radiant Heating and Cooling Systems 5925 148 th Street West 2000 Argentia Rd., Plaza 1, Ste. 200 AQUASAFE Fire Safety Systems Apple Valley, MN 55124 USA Mississauga, ON L5N IWI CANADA Phone: (800) 321-4739 Phone: (888) 994-7726 Fax: (952) 891-2008 Fax: (800) 638-9517 www.uponor-usa.com www.uponor.ca 'ProPEXO is a registered trademark of Uponor, Inc. ProPEX­ is a trademark of Uponor Ltd. ProPEXO Engineered Polymer (EP) Tee Uponof Submittal Information Revision D: June 8, 2012 Project Information Job Name: Location: Part No. Ordered: Engineer: Date Submitted: Contractor: Submitted By: Manufacturer's Representative: Approved By: Technical Data Material: UDEO Polysulfone, 20% Glass -reinforced (1/2" to 1") AcudelO Modified Polyphenylsulfone (11/4" to 11/2") RadelO Polyphenylsulfone (2") Maximum Temperature (no pressure): 320-F(160-C) Maximum Working Temperature/Pressure: 210OF (990C) at 150 psi (1,034 kPa) Product Information and Application Use The ProPEXO Engineered Polymer (EP) Tee makes diverting connections for Uponor crosslinked polyethylene (PEX-a) tubing for use in hot and cold domestic potable water systems, residential fire sprinkler systems and hydronic radiant heating and cooling systems. Each end of the tee is manufactured with an Uponor ProPEX fitting for connections to Uponor AquaPEXO or Wirsbo hePEXT" tubing.' Note: Branch size is listed last in the part descriptions. V Description Part Number A B Weight [3 ProPEX EP Tee, 1/2" PEX x 1/2" PEX x 1/2" PEX Q4755050 2.50" 1.53" 0.02 lbs. ProPEX EP Tee, 3/4" PEX x 3/4" PEX x 3/4" PEX Q4757575 3.30" 1.94" 0.05 lbs. ProPEX EP Tee, 1" PEX x I" PEX x 1" PEX Q4751010 4. 10" 2.47" 0.07 lbs. E3 ProPEX EP Tee, 11/4" PEX x 11/4" PEX x 11/4" PEX Q4751313 4.80" 3.22" 0. 15 lbs. E] ProPEX EP Tee, 11/2" PEX x 11/2" PEX x 11/2" PEX Q4751515 5.80" 3.82" 0.25 lbs. D ProPEX EP Tee, 2" PEX x 2" PEX x 2" PEX Q4752000 7.45" 4.79" 0.38 lbs. Installation Use the appropriate ProPEX Ring for PEX-a tubing. Refer to the Uponor AquaPEXO Professional Plumbing Installation Guide, AquaSAFE TM Residential Fire Sprinkler Installation Guide or Uponor Radiant Installation Handbook for additional information. Standards CAN/CSA B137.5; ASTM F877; ASTM F1960 Codes IPC; UPC; NSPC; NPC of Canada Listings IAPMO 3558; ANSI/NSF 14- and 61-certified; HUD MR 1269; ICC ESR 1099; UL 1821; ULC/ORD-C199P Related Applications Contact Information PEX-a Plumbing Systems Uponor, Inc. Uponor Ltd. Hydronic Radiant Heating and Cooling Systems 5925 148th Street West 2000 Argentia Road, Plaza 1, Suite 200 Snow Melting Systems Apple Valley, MN 55124 USA Mississauga, ON L5N 1W1 CANADA Turf Conditioning Systems Phone: (800) 321-4739 Phone: (888) 994-7726 Permafrost Prevention Systems Fax: (952) 891-2008 Fax: (800) 638-9517 AquaSAFE Fire Safety Systems www.uponorpro.com www.uponorpro.com 1 ProPEXO is a registered trademark of Uponor, Inc. ProPEX'" is a trademark of Uponor Ltd. ProPEXO Engineered Polymer (EP) Reducing Tee Uporlof Submittal Information Revision E: June 8, 2012 Project Information Job Name: Location: Part No. Ordered: Engineer: Date Submitted: Contractor: Submitted By: Manufacturer's Representative: Approved By: Technical Data Material: UDELS Polysulfone, 20% Glass -reinforced (1/2 to I") AcudelQD Modified Polyphenylsulfone (11/4" to 11/2") RadelO R Poly phenylsu Ifone (2") Maximum Temperature (no pressure): 320OF(1600C) Max. Working Temperature/Pressure: 210OF (990C) at 150 psi (1,034 kPa) Product Information and Application Use The ProPEXO Engineered Polymer (EP) Reducing Tee makes diverting connections for Uponor crosslinked polyethylene (PEX-a) tubing for use in hot and cold domestic potable water systems, residential fire sprinkler systems and hydronic radiant heating and cooling systems. Each end of the tee is manufactured with an Uponor ProPEX fitting for connections to Uponor AquaPEXO or Wirsbo hePEXT1 tubing.' Note: Branch size is listed last in the part descriptions. V Description Part Number Length (A) Height (B) Weight [] ProPEX EP Reducing Tee, 1/2" PEX x 1/2" PEX x Y4" PEX Q4755575 2.86" 1.76" 0.03 lbs. E] ProPEX EP Reducing Tee, 3/4" PEX x 1/2 PEX x 1/2" PEX Q4757555 3.10" 1.70" 0.04 lbs. ProPEX EP Reducing Tee, 3/4 P E X x 1/2 PEX x 3/4" PEX Q4757557 3.10" 1.94" 0.04 lbs. ProPEX EP Reducing Tee, 3/4 P E X x 3/4 P E X x 5/b " P E X Q4757563 3.30" 1.85" 0.05 lbs. E] ProPEX EP Reducing Tee, Y4" PEX x 3/4" PEX x 1/2" PEX Q4757550 3.30" 1.70" 0.04 lbs. EJ ProPEX EP Reducing Tee, Y4" PEX x 3/4 " PEX x 1" PEX Q4757710 3.64" 2.32" 0.08 lbs. ProPEX EP Reducing Tee, I" PEX x 3/4" PEX x 3/4" PEX Q4751775 3.90" 2.24" 0.08 lbs. ProPEX EP Reducing Tee, 1" PEX x 3/4" PEX x 1" PEX Q4751751 3.90" 2.47" 0.08 lbs. r] ProPEX EP Reducing Tee, 1" PEX x 1" PEX x 1/2" PEX Q4751150 4.10" 2.00" 0.08 lbs. ProPEX EP Reducing Tee, I" PEX x 1" PEX x 3/4" PEX Q4751175 4.10" 2.24" 0.09 lbs. ProPEX EP Reducing Tee, 11/4" PEX x 1" PEX x 3/4" PEX Q4751317 4.60" 2.73" 0.11 lbs. ProPEX EP Reducing Tee, 11/4" PEX x 1" PEX x 1" PEX Q4751311 4.60" 2.97" 0.12 lbs. ProPEX EP Reducing Tee, 11/4" PEX x 11/4" PEX x 3/4" PEX Q4751337 4.80" 2.73" 0.13 lbs. ProPEX EP Reducing Tee, 11/4" PEX x 11/4" PEX x I" PEX Q4751331 4.80" 2.97" 0.14 lbs. ProPEX EP Reducing Tee, 11/2" PEX x 1" PEX x 3/4" PEX Q4751517 5.25" 3.06" 0.17 lbs. C] ProPEX EP Reducing Tee, 11/2" PEX x 1" PEX x 1" PEX Q4751511 5.25" 3.30" 0. 18 lbs. ProPEX EP Reducing Tee, 11/2" PEX x 11/4" PEX x 3/4" PEX Q4751537 5.50" 2.65" 0.18 lbs. ProPEX EP Reducing Tee, 11/2" PEX x 11/4" PEX x 1" PEX Q4751531 5.501, 2.85" 0.19 lbs. ProPEX EP Reducing Tee, 11/2" PEX x 11/4" PEX x 11/4" PEX Q4751533 5.501, 3.15" 0.21 lbs. ProPEX EP Reducing Tee, 11/2" PEX x 11/2" PEX x 3/4" PEX Q4751557 5.80" 3.06" 0.20 lbs. E:1 ProPEX EP Reducing Tee, 1112." PEX x 11/2" PEX x 1" PEX Q4751551 5.75" 3.30" 0.21 lbs. [:1 ProPEX EP Reducing Tee, 11/2" PEX x 11/2" PEX x 11/4" PEX Q4751553 5.80" 3.56" 0.22 lbs. El ProPEX EP Reducing Tee, 2" PEX x 11/2" PEX x 3/4" PEX Q4752575 6.62" 3.30" 0.30 lbs. El ProPEX EP Reducing Tee, 2" PEX x 11/2" PEX x 1" PEX Q4752051 6.50" 3.40" 0.30 lbs. El ProPEX EP Reducing Tee, 2" PEX x 11/2" PEX x 11/4" PEX Q4752053 6.62" 3.80" 0.34 lbs. 0 ProPEX EP Reducing Tee, 2" PEX x 11/2" PEX x 11/2" PEX Q4752055 6.62" 4.10" 0.35 lbs. El ProPEX EP Reducing Tee, 2" PEX x 2" PEX x 3/4" PEX Q4752275 6.93" 3.30" 0.34 lbs. ProPEX EP Reducing Tee, 2" PEX x 2" PEX x I" PEX Q4752210 6.93" 3.40" 0.36 lbs. ProPEX EP Reducing Tee, 2" PEX x 2" PEX x 11/4" PEX Q4752213 6.62" 3.80" 0.37 lbs. ProPEX EP Reducing Tee, 2" PEX x 2" PEX x 11/2" PEX Q4752215 7.13" 4.10" 0.44 lbs. Installation Use the appropriate ProPEX Ring for PEX-a tubing. Refer to the Uponor AquaPEXO Professional Plumbing Installation Guide, AquaSAFETI Residential Fire Sprinkler Installation Guide or Uponor Radiant Installation Handbook for additional information. Standards Codes Listings CAN/CSA B137.5; ASTM F877; IPC; UPC; NSPC; NPC of Canada NSF U.P. CODE; ANSI/NSF 14- and 61-certified; HUD MR 1269; ASTM F1960 ICC ESR 1099; UL 1821 and ULC/ORD-C199P (except Q4757563) Related Applications Contact Information PEX-a Plumbing Systems Uponor, Inc. Uponor Ltd. Hydronic Radiant Heating and Cooling Systems 5925 148 th Street West 2000 Argentia Rd., Plaza 1, Ste. 200 Snow and Ice Melting Systems Apple Valley, MN 55124 USA Mississauga, ON L5N 1WI CANADA Turf Conditioning Systems Phone: (800) 321-4739 Phone: (888) 994-7726 Permafrost Protection Systems Fax: (952) 891-2008 Fax: (800) 638-9517 AquaSAFE Fire Safety Systems www.uponorpro.com www.uponorpro.com 1 ProPEXO is a registered trademark of Uponor, Inc. ProPEX­ is a trademark of Uponor Ltd. ProPEX-0 Engineered Submittal Information Revision D: June 8, 2012 Project Information Polymer (EP) Elbow Uponof Location: Part No. Ordered: Engineer: Date Submitted: Contractor: Submitted By: Manufacturer's Representative: Approved By: Technical Data Material: UDELO Polysulfone, 20% Glass -reinforced (1/2 to 1") AcudelO Modified Polyphenylsulfone (11/4" to 11/2") RadelO R Polyphenylsulfone (2") Maximum Temperature (no pressure): 320-F(160-C) Maximum Working Temperature/Pressure: 210OF (990C) at 150 psi (1,034 kPa) Product Information and Application Use The ProPEXO Engineered Polymer (EP) Elbow makes 90-degree connections for Uponor crosslinked polyethylene (PEX-a) tubing for use in hot and cold domestic potable water systems, residential fire safety and hydronic radiant heating and cooling systems. Each end of the elbow is manufactured with an Uponor ProPEX fitting for connections to Uponor AquaPEXO or Wirsbo hePEXTM tubing.' I -A B V Description Part A B Weight Number E] ProPEX EP Elbow, 1/2" PEX x 1/2" PEX Q4760500 1.30" 1.30" 0.02 lbs. 0 ProPEX EP Elbow, 3/4" PEX x 3/4" PEX Q4760750 1.60" 1.60" 0.03 lbs. 0 ProPEX EP Elbow, 1" PEX x 1" PEX Q4761000 2. 10" 2.10" 0.07 lbs. ProPEX EP Elbow, 11/4" PEX x 11/4" PEX Q4761250 2.45" 2.45" 0.11 lbs. ProPEX EP Elbow, 11/2" PEX x 11/2" PEX Q4761500 2.77" 2.77" 0. 18 1 bs. ProPEX EP Elbow, 2" PEX x 2" PEX Q4762000 3.76" 3.76" 0.30 lbs. Installation Use the appropriate ProPEX Ring for PEX-a tubing. Refer to the Uponor AquaPEXO Professional Plumbing Installation Guide, AquaSAFE'" Residential Fire Sprinkler Installation Guide or Uponor Radiant Installation Handbook for additional information. Standards CAN/CSA B137.5; ASTM F877; ASTM F1960 Codes IPC; UPC; NSPC; NPC of Canada Listings IAPMO 3558; ANSI/NSF 14- and 61-certified; HUD MR 1269; ICC ESR 1099; UL 1821; ULC/ORD-C199P Related Applications Contact Information PEX-a Plumbing Systems Uponor, Inc. Uponor Ltd. Hydronic Radiant Heating and Cooling Systems 5925 148th Street West 2000 Argentia Road, Plaza 1, Suite 200 Snow Melting Systems Apple Valley, MN 55124 USA Mississauga, ON L5N 1W1 CANADA Turf Conditioning Systems Phone: (800) 321-4739 Phone: (888) 994-7726 Permafrost Prevention Systems Fax: (952) 891-2008 Fax: (800) 638-9517 AquaSAFE Fire Safety Systems www.uponorpro.com www.uponorpro.com 1 ProPEX8 is a registered trademark of Uponor, Inc. ProPEX­ is a trademark of Uponor Ltd uponof ProPEXO Fire Sprinkler Adapter Submittal Information Revision B: March 17, 2009 Project Information Job Name: Location: -Part No. Ordered: Engineer: Date Submitted: Contractor: Submitted By: Manufacturer's Representative: Approved By: Technical Data Material: 300 Series Stainless Steel Product Information and Application Use Use the ProPEXO Fire Sprinkler Adapter in conjunction with the appropriate sprinkler to provide a multi -purpose residential fire sprinkler system'. For residential applications, the system is installed with the cold -potable portion of the Uponor plumbing system. Make connections with Uponor ProPEX fittings. These fittings are designed for use only with 3/4" or 1" AquaPEXO White tubing in the Uponor AQUASAFEO Looped System. =EM E D A C v" Description Part A B C D E Weight Number F] ProPEX Fire Sprinkler Adapter, 3/4" PEX x 1/2" FNPT Q7517550 0.75" 1.88" 2.50" 1.82" 1.41" 0.268 lbs. RProPEX Fire Sprinkler Adapter, 1" PEX x 1/2" FNPT Q7511050 0.75" 1.88" 2.50" 2.06" 1.54" 0.408 lbs. Installation Use appropriate ProPEX Ring for connecting the tubing. Refer to the AquaPEX Installation Handbook or the Uponor AQUASAFEO Installation Guide for additional information. Standards CAN/CSA B137.5; ASTM F877; ASTM F 1960 Codes IPC; UPC; NSPC; IRC; IMC; NPC of Canada Listings ANSI/NSF 14- and 61-certified; U.P. Code; ICC ESR 1099; HUD MR 1269; UL 1821; ULC/ORD - C 199 P Related Applications Contact Information PEX-a Plumbing Systems Uponor, Inc. Uponor Ltd. AQUASAFE Fire Safety Systems 5925 148th Street West 2000 Argentia Rd., Plaza 1, Ste. 200 Apple Valley, MN 55124 USA Mississauga, ON L5N 1W1 CANADA Phone: (800) 321-4739 Phone: (888) 994-7726 Fax: (952) 891-2008 Fax: (800) 638-9517 www.uponor-usa.com www.uponor.ca 'ProPEXO is a registered trademark of Uponor, Inc. ProPEXI" is a trademark of Uponor Ltd. The Design Criteria for Sloped & Sloped Beamed Ceilings in NFPA 13D One and Two Family Dwellings & Manufactured Homes Has Changed. f 02 L L L/1' A '��C *_8 ELCV-"0N.1 LISTED AREA OF COVERAGE CORRESPONDS TO CEILING SLOP L -THE MAXIMUM LISTED SPRINKLER SPACING LENGTH 0(r-(rMAXIMU1K (V.W MINiMUK . L12 - ONE HALF THE MAXIMUM LISTED SPRINKLER SPACING (5'.TMAXIMU4 (4'4rMINIMUM) W -THE MAXIMUM LISTED SPRINKLER SPACING. WIDTH (IV-01 A T4r MAXIMUM. 8 RANGE: 2112 (9.41 � 8 $6112 (33.71 . C V-(r MINIMUM. L A-T (r.AXIMLOA A Tentative Interim Amendment (TIA No-1028R) to NFPA 13D for 2010 has been issued by the NFPA Standards Council. Testing supported by The Fire Protection Research Foundation indicates that residential sprinklers listed for applications with smooth, flat ceilings can meet the stated purpose in NFPA 13D standards when installed on a sloped or sloped and beamed ceiling. Sloped and Sloped/Beamed Ceili , ngs, under certain conditions, can now be protected with residential sprinklers based upon a maximum two (2) sprinkler demand that has the same flow rate as the sprinklers smooth, flat ceiling listing. The TIA No.1 028R revises NFPA 13D - 2010 edition sections�8-1.2, 8.1.3, A.8.,11.2, and A.8.1.3. Please read and adhere to these sections for the complete new design criteria. A brief recap: The sprinklers in the design area shall be all of the sprinklers in a compartment, up to a maximum of two, which require the greatest demand for: • Smooth, flat ceilings to a maximum 24 feet in height. • Smooth, ceilings (with no beams) sloped up to 8/12 and a maximum ceiling height of 24' above the floor. 9 A ceiling with beams up to 14" deep sloped up to 8/12 and a maximum ceiling height of 24'above the floor. Pendent sprinklers shall be installed under the"beams and the compartment cannot exceed 600 square feet. I A ceiling with beams of any depth sloped up to 8/12 and a maximum ceiling height of 24'above the floor. Sidewall or pendent sprinklers shall be installed in each pocket formed by the beams and the compartment cannot exceed 600 square feet. �All Re1iabId__rd§1db_hti6I tprinklerscan be Used for the_§e applidation§-bas6d I ressure as listed for smooth and flat ceilings. (See Bulletins: 135,-006, 033 and- 032)-.1 p This TIAis for 13D applications only. Changes to 13R will be in the 2013 Edition. Our special 10'x 10' spacing listings for sloped ceilings are still advantageous for 13R installations. (See Table 9, Bulletin 035). For any questions, please contact Technical Services at 1-800-55-RASCO. The Reliable Automafic Spirlinkler Co., Inc. - Manufacturer & Distributor of Fire Protection Equipment www.reliablesprinkler.com e 1.80OA31.1588 .............. a ..... W.-M WASHINGTON STATE so CERTIFICATE OF COMPETENCY a FIRE PROTW"ON SISKINKLER SYSTEMS on RA SjfnatU(>Y Date 1213-IMT b..W ......... W. Allow r)]ESIGN A-PEX Design Services, Inc.-EP 10731 47th Place West Mukilteo, WA 98275 425-493-9680 sales@a-pexdesignservices.com Job Name FENG RESIDENCE - One Head Calculation (H.38) Drawing Location 24025 74th AVE WEST EDMONDS WA 98026 Remote Area MECIPOVE Contract 170109-02 Data File : 170109-02 Feng Residence.wxl JAN 17 2017 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Z A-PEX Design Services, Inc.-EP FENG RESIDENCE - One Head Calculation (H.38) HYDRAULIC DESIGN INFORMATION SHEET Page 1 Date 1/9/2017 Name - FENG RESIDENCE Date 01-09-2017 Location - EDMONDS WA 98026 Building - System No. - Contractor - HOMEOWNER Contract No. 170109-02 Calculated By - STEPHANIE FAHEY Drawing No. - Construction: (X) Combustible Non -Combustible Ceiling Height OCCUPANCY - RESIDENTIAL S Type of Calculation: ( )NFPA 13 Residential )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: Wl )2 )4 S )Other T )Specific Ruling Made by Date E M Listed Flow at Start Point - 17 Gpm System Type Listed Pres. at Start Point - 12.03Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 18 x 18 ) Deluge ( ) PreAction E Domestic Flow Added - 0 Gpm Sprinkler or Nozzle S Additional Flow Added - Gpm Make RELIABLE Model LL-RFC49 I Elevation at Highest Outlet - 124 Feet Size 3/8 K-Factor 4.9 G Note: Temperature Rating 155 N Calculation Gpm Required 17 Psi Required 58.45 At Ref Pt STR Summary C-Factor Used: Overhead 150 Underground 150 W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - Rated Cap. Cap. T Time of Test - @ Psi Elev. E Static (Psi) - 95 Elev. R Residual (Psi) - 90 Other Well Flow (Gpm) - 300 Proof Flow Gpm S Elevation - 100 P Location: P L Source of Information: Y Computer Programs by Hydratec Inc. Route 111 VVindharn N.H. USA 03087 Water Supply Curve C A- ' PEX Design Services, Inc.-EP Page 2 FENG RESIDENCE - One Head Calculation (H.38) Date 1/9/2017 City Water Supp!y: Demand: C1 - Static Pressure : 95 D1 - Elevation 10.394 C2 - Residual Pressure: 90 D2 - System Flow :16.995 C2 - Residual Flow 300 D2 - System Pressure 58.452 Hose (Demand) D3 - System Demand 16.995 Safety Margin 36.524 150 140 130 p 120 R 110 E ioo C2 S 90 S 80 u 70 D2 R 60 E 50 40 30 20 1 10 D1 50 100 150 200 250 300 350 400 450 FLOW (N - 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary A-PEX Design Services, Inc.-EP FENG RESIDENCE - One Head Calculation (H.38) Page Date 3 1/9/2017 Fitting Legend Abbrev. Name C Roll Groove Coupling 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 E 90' Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G Generic Gate Valve 1 1 1 1 1 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T 90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Uel * Aquapex 90 Elbow 11 11 12 11 13 18 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Utb * Aquapex Tee - Branch 2 17 14 9 12 17 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Utr * Aquapex Tee - Run 1 2 2 4 2 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Units Summary Diameter Units Length Units Flow Units Pressure Units Inches Feet US Gallons per Minute Pounds per Square Inch Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summ.ary - NFPA 2007 A-PEX Design Services, Inc.-EP Page 4 FENG RESIDENCE - One Head Calculation (H.38) Date 1/9/2017 SUPPLYANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure STR 95.0 90 300.0 94.975 17.0 58.452 NODEANALYSIS Pressure Discharge Node Tag Elevation Node Type atNode at Node Notes H.38 124.0 4.9 12.03 17.0 H.28 124.0 13.04 T.51 124.0 13.57 H.25 124.0 13.96 T.49 124.0 14.39 T.43 116.0 19.74 T.44 116.0 20.02 H.16 116.0 20.38 T.53 116.0 20.54 T.54 116.0 20.62 T.52 116.0 21.14 S.1 104.0 26.63 PRV 100.0 43.61 CPL 100.0 44.27 MTR 100.0 56.03 STR 100.0 58.45 T.58 124.0 12.42 H.36 124.0 12.8 H.32 124.0 13.41 H.33 124.0 13.85 T.56 124.0 14.24 T.48 116.0 19.97 HA 1 124.0 13.67 H.12 124.0 13.74 H.9 124.0 13.91 H.10 124.0 14.08 H.24 124.0 14.23 T.50 124.0 14.28 H.23 124.0 14.37 T.57 124.0 14.24 H.37 124.0 14.25 H.34 124.0 14.25 H.30 124.0 14.26 H.7 116.0 19.74 H.8 116.0 19.77 H.2 116.0 19.8 HA 116.0 19.83 HA 116.0 19.86 H.3 116.0 19.87 H.5 116.0 19.89 T.42 116.0 19.9 H.17 116.0 19.92 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - NFPA 2007 A-PE)� Design Services, Inc.-EP Page 5 FENG RESIDENCE - One Head Calculation (H.38) Date 1/9/2017 NODE ANALYSIS (cont.) Pressure Discharge Node Tag Elevation Node Type at Node at Node H.20 116.0 19.94 T.45 116.0 19.95 T.46 116.0 19.95 H.19 116.0 19.96 H.21 116.0 19.96 T.55 108.0 23.7 H.26 108.0 23.77 H.39 108.0 23.84 T.59 108.0 23.86 H.27 108.0 23.71 H.13 108.0 23.73 H.14 108.0 23.75 H.15 108.0 23.76 H.22 108.0 23.77 T.47 108.0 23.77 H. 18 108.0 23.79 H.31 108.0 23.8 H.41 108.0 23.81 T.60 108.0 23.82 H.35 108.0 23.83 H.40 108.0 23.85 Notes Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams A-PEX Design Services, Inc.-EP Page 6 FENG RESIDENCE - One Head Calculation (H.38) Date 1/9/2017 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. .'C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pin H.38 7.62 0.862 Uel 11.0 15.000 12.030 K Factor = 4.90 to 150.0 0.0 12.000 0.0 H.28 7.62 0.0376 0.0 27.000 1.015 Vel = 4.19 H.28 0.0 0.862 Uel 11.0 2.000 13.045 to 150.0 0.0 12.000 0.0 T.51 7.62 0.0376 0.0 14.000 0.527 Vel = 4.19 T.51 -2.80 0.862 Utb 17.0 10.000 13.572 to 150.0 0.0 14.000 0.0 H.25 4.82 0.0161 0.0 24.000 0.387 Vel = 2.65 H.25 0.0 0.862 Uel 11.0 15.000 13.959 to 150.0 0.0 12.000 0.0 T.49 4.82 0.0161 0.0 27.000 0.435 Vel = 2.65 T.49 3.55 0.862 2Utb 34.0 14.000 14.394 to 150.0 0.0 28.000 3.465 T.43 8.37 0.0447 0.0 42.000 1.879 Vel = 4.60 T.43 -1.07 0.862 Utr 2.0 6.000 19.738 to 150.0 0.0 2.000 0.0 T.44 7.3 0.0348 0.0 8.000 0.278 Vel = 4.01 T.44 -2.65 0.862 Uel 11.0 12.000 20.016 to 150.0 0.0 12.000 0.0 H.16 4.65 0.0151 0.0 24.000 0.362 Vel = 2.56 H.16 0.0 0.862 Utr 2.0 9.000 20.378 to 150.0 0.0 2.000 0.0 T.53 4.65 0.0151 0.0 11.000 0.166 Vel = 2.56 T.53 0.0 0.862 Utr 2.0 3.000 20.544 to 150.0 0.0 2.000 0.0 T.54 4.65 0.0152 0.0 5.000 0.076 Vel = 2.56 T.54 2.65 0.862 Utb 17.0 1.000 20.620 to 150.0 0.0 14.000 0.0 T.52 7.3 0.0347 0.0 15.000 0.521 Vel = 4.01 T.52 9.70 1.244 T 3.443 7.000 21.141 to 150.0 0.0 3.443 5.197 SA 17.0 0.0278 0.0 10.443 0.290 Vel = 4.49 S.1 0.0 1.244 2E 3.443 5.000 26.628 to 150.0 C 0.43 3.873 16.732 Fixed Loss 15 PRV 17.0 0.0278 0.0 8.873 0.247 Vel = 4.49 PRV 0.0 1.244 2E 3.443 20.000 43.607 to 150.0 C 0.43 3.873 0.0 CPIL 17.0 0.0278 0.0 23.873 0.663 Vel = 4.49 CPL 0.0 1.244 2E 3.443 60.000 44.270 to 150.0 0.0 3.443 10.000 Fixed Loss 10 MTR 17.0 0.0278 0.0 63.443 1.763 Vel = 4.49 MTR 0.0 0.995 E 2.336 20.000 56.033 to 150.0 T 5.841 9.345 0.0 STIR 17.0 0.0824 G 1.168 29.345 2.419 Vel = 7.01 0.0 17.00 58.452 K Factor= 2.22 H.38 9.37 0.862 0.0 7.000 12.030 to 150.0 0.0 0.0 0.0 T.58 9.37 0.0551 0.0 7.000 0.386 Vel = 5.15 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams A-PEX Design Services, Inc.-EP Page 7 FENG RESIDENCE - One Head Calculation (H.38) Date 1/9/2017 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. I.C11 or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn T.58 0.0 0.862 Utr 2.0 5.000 12.416 to 150.0 0.0 2.000 0.0 H.36 9.37 0.0551 0.0 7.000 0.386 Vel = 5.15 H.36 0.0 0.862 Utr 2.0 9.000 12.802 to 150.0 0.0 2.000 0.0 H.32 9.37 0.0551 0.0 11.000 0.606 Vel = 5.15 H.32 0.0 0.862 Utr 2.0 6.000 13.408 to 150.0 0.0 2.000 0.0 H.33 9.37 0.0552 0.0 8.000 0.442 Vel = 5.15 H.33 0.0 0.862 Utr 2.0 5.000 13.850 to 150.0 0.0 2.000 0.0 T.56 9.37 0.0550 0.0 7.000 0.385 Vel = 5.15 T.56 -0.75 0.862 2Utb 34.0 20.000 14.235 to 150.0 0.0 28.000 3.465 T.48 8.62 0.0472 0.0 48.000 2.268 Vel = 4.74 T.48 1.07 0.862 Utb 17.0 6.000 19.968 to 150.0 0.0 14.000 0.0 T.52 9.69 0.0586 0.0 20.000 1.173 Vel = 5.33 0.0 9.69 21.141 K Factor= 2.11 T. 51 2.80 0.862 Utr 2.0 15.000 13.572 to 150.0 0.0 2.000 0.0 H. 11 2.8 0.0059 0.0 17.000 0.100 Vel = 1.54 HA 1 0.0 0.862 Utr 2.0 10.000 13.672 to 150.0 0.0 2.000 0.0 H.12 2.8 0.0059 0.0 12.000 0.071 Vel = 1.54 H.12 0.0 0.862 Uel 11.0 16.000 13.743 to 150.0 0.0 12.000 0.0 H.9 2.8 0.0059 0.0 28.000 0.165 Vel = 1.54 H.9 0.0 0.862 Uel 11.0 15.000 13.908 to 150.0 Utr 2.0 14.000 0.0 H.10 2.8 0.0059 0.0 29.000 0.172 Vel = 1.54 H.10 0.0 0.862 Uel 11.0 14.000 14.080 to 150.0 0.0 12.000 0.0 H.24 2.8 0.0059 0.0 26.000 0.153 Vel = 1.54 H.24 0.0 0.862 0.0 7.000 14.233 to 150.0 0.0 0.0 0.0 T.50 2.8 0.0060 0.0 7.000 0.042 Vel = 1.54 T.50 0.75 0.862 Utr 2.0 8.000 14.275 to 150.0 0.0 2.000 0.0 H.23 3.55 0.0091 0.0 10.000 0.091 Vel = 1.95 H.23 0.0 0.862 Utr 2.0 1.000 14.366 to 150.0 0.0 2.000 0.0 T.49 3.55 0.0093 0.0 3.000 0.028 Vel = 1.95 0.0 3.55 14.394 K Factor= 0.94 T.56 0.75 0.862 Utr 2.0 2.000 14.235 to 150.0 0.0 2.000 0.0 T.57 0.75 0.0008 0.0 4.000 0.003 Vel = 0.41 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams A-PEX Design Services, Inc.-EP Page 8 FENG RESIDENCE - One Head Calculation (H.38) Date 1/9/2017 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "Cl, or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn T.57 0.0 0.862 Uel 11.0 7.000 14.238 to 150.0 0.0 12.000 0.0 H.37 0.75 0.0005 0.0 19.000 0.009 Vel = 0.41 H.37 0.0 0.862 0.0 9.000 14.247 to 150.0 0.0 0.0 0.0 H.34 0.75 0.0006 0.0 9.000 0.005 Vel = 0.41 H.34 0.0 0.862 Utr 2.0 9.000 14.252 to 150.0 0.0 2.000 0.0 H.30 0.75 0.0005 0.0 11.000 0.006 Vel = 0.41 H.30 0.0 0.862 Utb 17.0 7.000 14.258 to 150.0 Uel 11.0 26.000 0.0 T.50 0.75 0.0005 0.0 33.000 0.017 Vel = 0.41 0.0 0.75 14.275 K Factor= 0.20 T.43 1.07 0.862 Utr 2.0 4.000 19.738 to 150.0 0.0 2.000 0.0 H.7 1.07 0.0010 0.0 6.000 0.006 Vel = 0.59 H.7 0.0 0.862 Uel 11.0 15.000 19.744 to 150.0 0.0 12.000 0.0 H.8 1.07 0.0010 0.0 27.000 0.026 Vel = 0.59 H.8 0.0 0.862 Uel 11.0 15.000 19.770 to 150.0 0.0 12.000 0.0 H.2 1.07 0.0010 0.0 27.000 0.027 Vel = 0.59 H.2 0.0 0.862 Uel 11.0 15.000 19.797 to 150.0 Utr 2.0 14.000 0.0 H. 1 1.07 0.0010 0.0 29.000 0.029 Vel = 0.59 HA 0.0 0.862 Uel 11.0 22.000 19.826 to 150.0 0.0 12.000 0.0 HA 1.07 0.0010 0.0 34.000 0.033 Vel = 0.59 HA 0.0 0.862 Utr 2.0 10.000 19.859 to 150.0 0.0 2.000 0.0 H.3 1.07 0.0010 0.0 12.000 0.012 Vel = 0.59 H.3 0.0 0.862 Uel 11.0 9.000 19.871 to 150.0 0.0 12.000 0.0 H.5 1.07 0.0010 0.0 21.000 0.021 Vel = 0.59 H.5 0.0 0.862 Utr 2.0 11.000 19.892 to 150.0 0.0 2.000 0.0 T.42 1.07 0.0010 0.0 13.000 0.013 Vel = 0.59 T.42 0.0 0.862 Utr 2.0 15.000 19.905 to 150.0 0.0 2.000 0.0 H.17 1.07 0.0010 0.0 17.000 0.017 Vel = 0.59 H.17 0.0 0.862 Utr 2.0 15.000 19.922 to 150.0 0.0 2.000 0.0 H.20 1.07 0.0010 0.0 17.000 0.017 Vel = 0.59 H.20 0.0 0.862 Utr 2.0 10.000 19.939 to 150.0 0.0 2.000 0.0 T.45 1.07 0.0009 0.0 12.000 0.011 Vel = 0.59 T.45 0.0 0.862 0.0 3.000 19.950 to 150.0 0.0 0.0 0.0 T.46 1.07 0.0013 0.0 3.000 0.004 Vel = 0.59 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams A-PEX Design Services, Inc.-EP Page 9 FENG RESIDENCE - One Head Calculation (H.38) Date 1/9/2017 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn T.46 0.0 0.862 Utr 2.0 3.000 19.954 to 150.0 0.0 2.000 0.0 H.19 1.07 0.0008 0.0 5.000 0.004 Vel = 0.59 H.19 0.0 0.862 Utr 2.0 4.000 19.958 to 150.0 0.0 2.000 0.0 H.21 1.07 0.0010 0.0 6.000 0.006 Vel = 0.59 H.21 0.0 0.862 Utr 2.0 2.000 19.964 to 150.0 0.0 2.000 0.0 T.48 1.07 0.0010 0.0 4.000 0.004 Vel = 0.59 0.0 1.07 19.968 K Factor= 0.24 T.44 2.65 0.862 2Utb 34.0 14.000 20.016 to 150.0 0.0 28.000 3.465 T.55 2.65 0.0053 0.0 42.000 0.223 Vel = 1.46 T.55 -0.80 0.862 Uel 11.0 12.000 23.704 to 150.0 0.0 12.000 0.0 H.26 1.85 0.0028 0.0 24.000 0.066 Vel = 1.02 H.26 0.0 0.862 Uel 11.0 12.000 23.770 to 150.0 0.0 12.000 0.0 H.39 1.85 0.0028 0.0 24.000 0.066 Vel = 1.02 H.39 0.0 0.862 0.0 7.000 23.836 to 150.0 0.0 0.0 0.0 T.59 1.85 0.0027 0.0 7.000 0.019 Vel = 1.02 T.59 0.80 0.862 2Utb 34.0 15.000 23.855 to 150.0 0.0 28.000 -3.465 T.54 2.65 0.0053 0.0 43.000 0.230 Vel = 1.46 0.0 2.65 20.620 K Factor= 0.58 T.55 0.80 0.862 Utr 2.0 4.000 23.704 to 150.0 0.0 2.000 0.0 H.27 0.8 0.0007 0.0 6.000 0.004 Vel = 0.44 H.27 0.0 0.862 Uel 11.0 29.000 23.708 to 150.0 0.0 12.000 0.0 H.13 0.8 0.0006 0.0 41.000 0.024 Vel = 0.44 H.13 0.0 0.862 Utr 2.0 17.000 23.732 to 150.0 Uel 11.0 14.000 0.0 H.14 0.8 0.0006 0.0 31.000 0.018 Vel = 0.44 H. 14 0.0 0.862 Utr 2.0 15.000 23.750 to 150.0 0.0 2.000 0.0 H.15 0.8 0.0005 0.0 17.000 0.009 Vel = 0.44 H.15 0.0 0.862 Uel 11.0 7.000 23.759 to 150.0 0.0 12.000 0.0 H.22 0.8 0.0006 0.0 19.000 0.011 Vel = 0.44 H.22 0.0 0.862 0.0 2.000 23.770 to 150.0 0.0 0.0 0.0 T.47 0.8 0.0005 0.0 2.000 0.001 Vel = 0.44 T.47 0.0 0.862 Utr 2.0 12.000 23.771 to 150.0 Uel 11.0 14.000 0.0 H.18 0.8 0.0006 0.0 26.000 0.015 Vel = 0.44 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams A-PEX Design Services, Inc.-EP Page 10 FENG RESIDENCE - One Head Calculation (H.38) Date 1/9/2017 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. ..C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pin H.18 0.0 0.862 Uel 11.0 13.000 23.786 to 150.0 0.0 12.000 0.0 H.31 0.8 0.0006 0.0 25.000 0.015 Vel = 0.44 H.31 0.0 0.862 Uel 11.0 10.000 23.801 to 150.0 0.0 12.000 0.0 H.41 0.8 0.0006 22.000 0.013 Vel = 0.44 H.41 0.0 0.862 -0.0 0.0 10.000 23.814 to 150.0 0.0 0.0 0.0 T.60 0.8 0.0006 0.0 10.000 0.006 Vel = 0.44 T.60 0.0 0.862 Utr 2.0 9.000 23.820 to 150.0 0.0 2.000 0.0 H.35 0.8 0.0005 0.0 11.000 0.006 Vel = 0.44 H.35 0.0 0.862 2Uel 22.0 16.000 23.826 to 150.0 0.0 24.000 0.0 H.40 0.8 0.0006 0.0 40.000 0.023 Vel = 0.44 H.40 0.0 0.862 Utr 2.0 9.000 23.849 to 150.0 0.0 2.000 0.0 T.59 0.8 0.0005 0.0 11.000 0.006 Vel = 0.44 0.0 0.80 23.855 KFactor= 0.16 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 WASHINGTON STATE CERTIFICATE OF COMPETENCY PIKE PROTECTION SPRINKLER SYSTEMS 'Chad P. Linklater .3894-0708-K Level I Alhwys Pluinbin V ALLWAP*03i0A-.. slanatuv Date A.._12—j3--I/j7j8 ftkgft-;-Jg "NOMA ell. A wo SF,RVI S G A-PEX Design Services, Inc.-EP 10731 47th Place West Mukilteo, WA 98275 425-493-9680 sales@a-pexdesignservices.com Job Name FENG RESIDENCE - Two Head Calculation (H.9 & H. 10) Drawing Location 24025 74th AVE WEST EDMONDS WA 98026 Remote Area Contract 170109-02 Data File 170109-02 Feng Residence.wx2 JAN 0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 A-PEX Design Services, Inc.-EP Page 1 FENG RESIDENCE - Two Head Calculation (H.9 & H.10) Date 1/9/2017 HYDRAULIC DESIGN INFORMATION SHEET Name - FENG RESIDENCE Date 01-09-2017 Location - EDMONDS WA 98026 Building - System No. - Contractor - HOMEOWNER Contract No. 170109-02 Calculated By - STEPHANIE FAHEY Drawing No. - Construction: (X) Combustible Non -Combustible Ceiling Height OCCUPANCY - RESIDENTIAL S Type of Calculation: ( )NFPA 13 Residential )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: )l (X)2 )4 S )Other T )Specific Ruling Made by Date E M Listed Flow at Start Point - 13 Listed Pres. at Start Point - 7.04 Psi D MAXIMUM LISTED SPACING 16 x 16 E Domestic Flow Added - 0 S Additional Flow Added - I Elevation at Highest Outlet - 124 G Note: N Gpm System Type (X) Wet ( ) Dry ( ) Deluge ( ) PreAction Gpm Sprinkler or Nozzle Gpm Make RELIABLE Model LL-RFC49 Feet Size 3/8 K-Factor 4.9 Temperature Rating 155 Calculation Gpm Required 26.082� Psi Required 67.47 At Ref Pt STR Summary C-Factor Used: Overhead 150 Underground 150 W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - Rated Cap. Cap. T Time of Test - @ Psi Elev. E Static (Psi) - 95 Elev. R Residual (Psi) - 90 Other Well Flow (Gpm) - 300 Proof Flow Gpm S Elevation - 100 P Location: P L Source of Information: Y Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C A-PEX Design Services, Inc.-EP FENG RESIDENCE - Two Head Calculation (H.9 & H. 10) Page 2 Date 1/9/2017' City Water Supply: Demand: C1 - Static Pressure : 95 D1 - Elevation 10.394 C2 - Residual Pressure: 90 D2 - System Flow 26.083 C2 - Residual Flow 300 D2 - System Pressure 67.475 Hose (Demand ) D3 - System Demand 26.083 Safety Margin 27.470 150 140 130 p 120 R 110 E 100 S 90 C2 S 80 U 70 R 60 E 50 40 30 20 10 —D —1 50 100 150 200 250 300 350 400 450 FLOW N - 1.85 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary A-PEX Design Services, Inc.-EP FENG RESIDENCE - Two Head Calculation (H.9 & H.10) Page Date 3 1/9/2017' Fitting Legend Abbrev. Name C Roll Groove Coupling 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 E 90'Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G Generic Gate Valve 1 1 1 1 1 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T 90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Uel * Aquapex 90 Elbow 11 11 12 11 13 18 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Utb * Aquapex Tee - Branch 2 17 14 9 12 17 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Utr * Aquapex Tee - Run 1 2 2 4 2 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Units Summary Diameter Units Length Units Flow Units Pressure Units Inches Feet US Gallons per Minute Pounds per Square Inch Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - NFPA 2007 A-PEX Design Services, Inc.-EP Page 4 FENG RESIDENCE - Two Head Calculation (H.9 & H. 10) Date 1/9/2017 SUPPLYANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure STIR 95.0 90 300.0 94.945 26.08 67.475 NODEANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes H.9 124.0 4.9 7.04 13.0 H.12 124.0 9.14 HA 1 124.0 10.03 T.51 124.0 11.3 H.25 124.0 11.7 T.49 124.0 12.14 T.43 116.0 20.34 T.44 116.0 21.0 H.16 116.0 21.86 T.53 116.0 22.25 T.54 116.0 22.43 T.52 116.0 23.66 S.1 104.0 29.5 PRV 100.0 46.78 CPL 100.0 48.24 MTR 100.0 62.13 STIR 100.0 67.47 H.10 124.0 4.9 7.13 13.08 H.24 124.0 10.56 T.50 124.0 11.48 H.30 124.0 12.31 H.34 124.0 12.58 H.37 124.0 12.8 T.57 124.0 13.28 T.56 124.0 13.38 T.48 116.0 21.2 H.28 124.0 11.66 H.38 124.0 12.35 T.58 124.0 12.53 H.36 124.0 12.71 H.32 124.0 12.99 H.33 124.0 13.2 H.23 124.0 11.99 H.7 116.0 20.36 H.8 116.0 20.46 H.2 116.0 20.56 H.1 116.0 20.67 HA 116.0 20.8 H.3 116.0 20.84 H.5 116.0 20.92 T.42 116.0 20.97 H.17 116.0 21.03 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - NFPA 2007 A-PEX Design Services, Inc.-EP FENG RESIDENCE - Two Head Calculation (H.9 & H.10) Page 5 Date 1/9/2017 NODE ANALYSIS (cont.) Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes H.20 116.0 21.09 T.45 116.0 21.14 T.46 116.0 21.15 H.19 116.0 21.17 H.21 116.0 21.19 T.55 108.0 24.99 H.26 108.0 25.15 H.39 108.0 25.31 T.59 108.0 25.35 H.27 108.0 25.0 H.13 108.0 25.06 H.14 108.0 25.1 H.15 108.0 25.12 H.22 108.0 25.15 T.47 108.0 25.15 H.18 108.0 25.19 H.31 108.0 25.22 H.41 108.0 25.25 T.60 108.0 25.27 H.35 108.0 25.28 H.40 108.0 25.34 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams A-PEX Design Services, Inc.-EP Page 6 FENG RESIDENCE - Two Head Calculation (H.9 & H.10) Date 1/9/2017 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. I.C., or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn H.9 11.05 0.862 Uel 11.0 16.000 7.040 K Factor = 4.90 to 150.0 0.0 12.000 0.0 H.12 11.05 0.0748 0.0 28.000 2.095 Vel = 6.07 H.12 0.0 0.862 Utr 2.0 10.000 9.135 to 150.0 0.0 2.000 0.0 H.1 1 11.05 0.0748 0.0 12.000 0.897 Vel = 6.07 H.1 1 0.0 0.862 Utr 2.0 15.000 10.032 to 150.0 0.0 2.000 0.0 T.51 11.05 0.0748 0.0 17.000 1.272 Vel = 6.07 T.51 -6.18 0.862 Utb 17.0 10.000 11.304 to 150.0 0.0 14.000 0.0 H.25 4.87 0.0164 0.0 24.000 0.394 Vel = 2.68 H.25 0.0 0.862 Uel 11.0 15.000 11.698 to 150.0 0.0 12.000 0.0 T.49 4.87 0.0164 0.0 27.000 0.443 Vel = 2.68 T.49 8.93 0.862 2Utb 34.0 14.000 12.141 to 150.0 0.0 28.000 3.465 T.43 13.8 0.1128 0.0 42.000 4.737 Vel = 7.59 T.43 -2.17 0.862 Utr 2.0 6.000 20.343 to 150.0 0.0 2.000 0.0 T.44 11.63 0.0821 0.0 8.000 0.657 Vel = 6.39 T.44 -4.22 0.862 Uel 11.0 12.000 21.000 to 150.0 0.0 12.000 0.0 H.16 7.41 0.0357 0.0 24.000 0.857 Vel = 4.07 H.16 0.0 0.862 Utr 2.0 9.000 21.857 to 150.0 0.0 2.000 0.0 T.53 7.41 0.0357 0.0 11.000 0.393 Vel = 4.07 T.53 0.0 0.862 Utr 2.0 3.000 22.250 to 150.0 0.0 2.000 0.0 T.54 7.41 0.0356 0.0 5.000 0.178 Vel = 4.07 T.54 4.22 0.862 Utb 17.0 1.000 22.428 to 150.0 0.0 14.000 0.0 T.52 11.63 0.0821 0.0 15.000 1.232 Vel = 6.39 T.52 14.45 1.244 T 3.443 7.000 23.660 to 150.0 0.0 3.443 5.197 S.1 26.08 0.0614 0.0 10.443 0.641 Vel = 6.88 S.1 0.0 1.244 2E 3.443 5.000 29.498 to 150.0 C 0.43 3.873 16.732 Fixed Loss 15 PRV 26.08 0.0614 0.0 8.873 0.545 Vel = 6.88 PRV 0.0 1.244 2E 3.443 20.000 46.775 to 150.0 C 0.43 3.873 0.0 CPL 26.08 0.0614 0.0 23.873 1.465 Vel = 6.88 CPL 0.0 1.244 2E 3.443 60.000 48.240 to 150.0 0.0 3.443 10.000 Fixed Loss 10 MTR 26.08 0.0613 0.0 63.443 3.892 Vel = 6.88 MTR 0.0 0.995 E 2.336 20.000 62.132 to 150.0 T 5.841 9,345 0.0 STR 26.08 0.1821 G 1.168 29.345 5.343 Vel = 10.76 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams A-PEX Design Services, Inc.-EP Page 7 FENG RESIDENCE - Two Head Calculation (H.9 & H.10) Date 1/9/2017 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. .1c" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 26.08 67.475 K Factor= 3.17 H.9 1.95 0.862 Uel 11.0 15.000 7.040 to 150.0 Utr 2.0 14.000 0.0 H.10 1.95 0.0030 0.0 29.000 0.087 Vel = 1.07 H.10 13.08 0.862 Uel 11.0 14.000 7.127 K Factor = 4.90 to 150.0 0.0 12.000 0.0 H.24 15.03 0.1321 0.0 26.000 3.434 Vel = 8.26 H.24 0.0 0.862 0.0 7.000 10.561 to 150.0 0.0 0.0 0.0 T.50 15.03 0.1320 0.0 7.000 0.924 Vel = 8.26 T.50 -8.93 0.862 Utb 17.0 7.000 11.485 to 150.0 Uel 11.0 26.000 0.0 H.30 6.1 0.0249 0.0 33.000 0.821 Vel = 3.35 H.30 0.0 0.862 Utr 2.0 9.000 12.306 to 150.0 0.0 2.000 0.0 H.34 6.1 0.0248 0.0 11.000 0.273 Vel = 3.35 H.34 0.0 0.862 0.0 9.000 12.579 to 150.0 0.0 0.0 0.0 H.37 6.1 0.0249 0.0 9.000 0.224 Vel = 3.35 H.37 0.0 0.862 Uel 11.0 7.000 12.803 to 150.0 0.0 12.000 0.0 T.57 6.1 0.0249 0.0 19.000 0.473 Vel = 3.35 T.57 0.0 0.862 Utr 2.0 2.000 13.276 to 150.0 0.0 2.000 0.0 T.56 6.1 0.0248 0.0 4.000 0.099 Vel = 3.35 T.56 6.18 0.862 2Utb 34.0 20.000 13.375 to 150.0 0.0 28.000 3.465 T.48 12.28 0.0909 0.0 48.000 4.363 Vel = 6.75 T.48 2.17 0.862 Utb 17.0 6.000 21.203 to 150.0 0.0 14.000 0.0 T.52 14.45 0.1228 0.0 20.000 2.457 Vel = 7.94 0.0 14.45 23.660 K Factor= 2.97 T.51 6.19 0.862 Uel 11.0 2.000 11.304 to 150.0 0.0 12.000 0.0 H.28 6.19 0.0256 0.0 14.000 0.358 Vel = 3.40 H.28 0.0 0.862 Uel 11.0 15.000 11.662 to 150.0 0.0 12.000 0.0 H.38 6.19 0.0256 0.0 27.000 0.690 Vel = 3.40 H.38 0.0 0.862 0.0 7.000 12.352 to 150.0 0.0 0.0 0.0 T.58 6.19 0.0256 0.0 7.000 0.179 Vel = 3.40 T.58 0.0 0.862 Utr 2.0 5.000 12.531 to 150.0 0.0 2.000 0.0 H.36 6.19 0.0256 0.0 7.000 0.179 Vel = 3.40 H.36 0.0 0.862 Utr 2.0 9.000 12.710 to 150.0 0.0 2.000 0.0 H.32 6.19 0.0256 0.0 11.000 0.282 Vel = 3.40 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams A-PEX Design Services, Inc.-EP Page 8 FENG RESIDENCE - Two Head Calculation (H.9 & H.10) Date 1/9/2017 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. .1c., or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn H.32 0.0 0.862 Utr 2.0 6.000 12,992 to 150.0 0.0 2.000 0.0 H.33 6.19 0.0255 0.0 8.000 0.204 Vel = 3.40 H.33 0.0 0.862 Utr 2.0 5.000 13.196 to 150.0 0.0 2.000 0.0 T.56 6.19 0.0256 0.0 7.000 0.179 Vel = 3.40 0.0 6.19 13.375 K Factor= 1.69 T.50 8.93 0.862 Utr 2.0 8.000 11.485 to 150.0 0.0 2.000 0.0 H.23 8.93 0.0505 0.0 10.000 0.505 Vel = 4.91 H.23 0.0 0.862 Utr 2.0 1.000 11.990 to 150.0 0.0 2.000 0.0 T.49 8.93 0.0503 0.0 3.000 0.151 Vel = 4.91 0.0 8.93 12.141 K Factor= 2.56 T.43 2.17 0.862 Utr 2.0 4.000 20.343 to 150.0 0.0 2.000 0.0 H.7 2.17 0.0037 0.0 6.000 0.022 Vel = 1.19 H.7 0.0 0.862 Uel 11.0 15.000 20.365 to 150.0 0.0 12.000 0.0 H.8 2.17 0.0037 0.0 27.000 0.100 Vel = 1.19 H.8 0.0 0.862 Uel 11.0 15.000 20.465 to 150.0 0.0 12.000 0.0 H.2 2.17 0.0037 0.0 27.000 0.100 Vel = 1.19 H.2 0.0 0.862 Uel 11.0 15.000 20.565 to 150.0 Utr 2.0 14.000 0.0 HA 2.17 0.0037 0.0 29.000 0.107 Vel = 1.19 HA 0.0 0.862 Uel 11.0 22.000 20.672 to 150.0 0.0 12.000 0.0 H.4 2.17 0.0037 0.0 34.000 0.125 Vel = 1.19 HA 0.0 0.862 Utr 2.0 10.000 20.797 to 150.0 0.0 2.000 0.0 H.3 2.17 0.0037 0.0 12.000 0.044 Vel = 1.19 H.3 0.0 0.862 Uel 11.0 9.000 20.841 to 150.0 0.0 12.000 0.0 H.5 2.17 0.0037 0.0 21.000 0.078 Vel = 1.19 H.5 0.0 0.862 Utr 2.0 11.000 20.919 to 150.0 0.0 2.000 0.0 T.42 2.17 0.0037 0.0 13.000 0.048 Vel = 1.19 T.42 0.0 0.862 Utr 2.0 15.000 20.967 to 150.0 0.0 2.000 0.0 H.17 2.17 0.0037 0.0 17,000 0.063 Vel = 1.19 H.17 0.0 0.862 Utr 2.0 15.000 21.030 to 150.0 0.0 2.000 0.0 H.20 2.17 0.0036 0.0 17.000 0.062 Vel = 1.19 H.20 0.0 0.862 Utr 2.0 10.000 21.092 to 150.0 0.0 2.000 0.0 T.45 2.17 0.0037 0.0 12.000 0.044 Vel = 1.19 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams A-PEX Design Services, Inc.-EP Page 9 FENG RESIDENCE - Two Head Calculation (H.9 & H. 10) Date 1/9/2017 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn T.45 0.0 0.862 0.0 3.000 21.136 to 150.0 0.0 0.0 0.0 T.46 2.17 0.0040 0.0 3.000 0.012 Vel = 1.19 T.46 0.0 0.862 Utr 2.0 3.000 21.148 to 150.0 0.0 2.000 0.0 H.19 2.17 0.0036 0.0 5.000 0.018 Vel = 1.19 H.19 0.0 0.862 Utr 2.0 4.000 21.166 to 150.0 0.0 2.000 0.0 H.21 2.17 0.0037 0.0 6.000 0.022 Vel = 1.19 H.21 0.0 0.862 Utr 2.0 2.000 21.188 to 150.0 0.0 2.000 0.0 T.48 2.17 0.0038 0.0 4.000 0.015 Vel = 1.19 0.0 2.17 21.203 K Factor= 0.47 T.44 4.22 0.862 2Utb 34.0 14.000 21.000 to 150.0 0.0 28.000 3.465 T.55 4.22 0.0126 0.0 42.000 0.529 Vel = 2.32 T.55 -1.27 0.862 Uel 11.0 12.000 24.994 to 150.0 0.0 12.000 0.0 H.26 2.95 0.0065 0.0 24.000 0.156 Vel = 1.62 H.26 0.0 0.862 Uel 11.0 12.000 25.150 to 150.0 0.0 12.000 0.0 H.39 2.95 0.0065 0.0 24.000 0.156 Vel = 1.62 H.39 0.0 0.862 0.0 7.000 25.306 to 150.0 0.0 0.0 0.0 T.59 2.95 0.0064 0.0 7.000 0.045 Vel = 1.62 T.59 1.27 0.862 2Utb 34.0 15.000 25.351 to 150.0 0.0 28.000 -3.465 T.54 4.22 0.0126 0.0 43.000 0.542 Vel = 2.32 0.0 4.22 22.428 K Factor= 0.89 T.55 1.27 0.862 Utr 2.0 4.000 24.994 to 150.0 0.0 2.000 0.0 H.27 1.27 0.0013 0.0 6.000 0.008 Vel = 0.70 H.27 0.0 0.862 Uel 11.0 29.000 25.002 to 150.0 0.0 12.000 0.0 H.13 1.27 0.0014 0.0 41.000 0.056 Vel = 0.70 H.13 0.0 0.862 Utr 2.0 17.000 25.058 to 150.0 Uel 11.0 14.000 0.0 H.14 1.27 0.0014 0.0 31.000 0.043 Vel = 0.70 H.14 0.0 0.862 Utr 2.0 15.000 25.101 to 150.0 0.0 2.000 0.0 H.15 1.27 0.0014 0.0 17.000 0.023 Vel = 0.70 H.15 0.0 0.862 Uel 11.0 7.000 25.124 to 150.0 0.0 12.000 0.0 H.22 1.27 0.0014 0.0 19.000 0.026 Vel = 0.70 H.22 0.0 0.862 0.0 2.000 25.150 to 150.0 0.0 0.0 0.0 T.47 1.27 0.0015 0.0 2.000 0.003 Vel = 0.70 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams A-PEX Design Services, Inc.-EP Page 10 FENG RESIDENCE - Two Head Calculation (H.9 & H.10) Date 1/9/2017 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C'. or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn T.47 0.0 0.862 Utr 2.0 12.000 25.153 to 150.0 Uel 11.0 14.000 0.0 H.18 1.27 0.0013 0.0 26.000 0.035 Vel = 0.70 H.18 0.0 0.862 Uel 11.0 13.000 25.188 to 150.0 0.0 12.000 0.0 H.31 1.27 0.0014 0.0 25.000 0.035 Vel = 0.70 H.31 0.0 0.862 Uel 11.0 10.000 25,223 to 150.0 0.0 12.000 0.0 H.41 1.27 0.0014 0.0 22.000 0.030 Vel = 0.70 H.41 0.0 0.862 0.0 10.000 25.253 to 150.0 0.0 0.0 0.0 T.60 1.27 0.0013 0.0 10.000 0.013 Vel = 0.70 T.60 0.0 0.862 Utr 2.0 9.000 25.266 to 150.0 0.0 2.000 0.0 H.35 1.27 0.0015 0.0 11.000 0.016 Vel = 0.70 H.35 0.0 0.862 2Uel 22.0 16.000 25.282 to 150.0 0.0 24.000 0.0 HAO 1.27 0.0014 0.0 40.000 0.054 Vel = 0.70 HAO 0.0 0.862 Utr 2.0 9.000 25.336 to 150.0 0.0 2.000 0.0 T.59 1.27 0.0014 0.0 11.000 0.015 Vel = 0.70 0.0 1.27 25.351 K Factor= 0.25 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087