BLD20170190 (2).pdfIIII�lIII
� oy EoMo COMPLETED
CITY OF EDMONDS
121 5TH AVENUE NORTH - EDMONDS, W A 98020
PHONE: (425) 771-0220 - FAX: (425 771-0221
i��. ►g90 )
STATUS: ISSUED 02/21/2017 Permit #: BLD20170190
Expiration Date: 02/21/2018
Parcel No: 27031300102000
Project Address: 9227 OLYMPIC VIEW DR,
EDMONDS
'1'11' 1—CONTRACTOR
MARK SNEERINGER KRISTIN HANSON THE WAY CO SEAN HELLEREN CONST
9227 OLYMPIC VIEW DR 652 ALDER ST C/O SEAN HELLEREN
EDMONDS, WA 98020 EDMONDS, WA 98020 317 ELM ST
EDMONDS, WA 98020
(425)774-7129 (425)239-6211
LICENSE #: WAYCOWC8881`2 EXP:10/29/2018
Ii DESCRIPTION
EXPAND LAUNDRY ROOM INTO EX. GARAGE. NO EXTERIOR WORK.
VALUATION: $10,000.00
PERMIT TYPE: Residential
PERMIT GROUP: 04 - Alteration/Remodel
GRADING: N CYDS- 0
TYPE OF CONSTRUCTION:
RETAINING WALL ROCKERY:
OCCUPANT GROUP:
OCCUPANT LOAD:
FENCE: ( 0 X 0 FT.)
CODE: 2015
OTHER: ------- OTHER DESC:
ZONE:
NUMBER OF STORIES: 0
VESTED DATE:
NUMBER OF DWELLING UNITS: 0
LOT #:
BASEMENT: 0 1 ST FLOOR: 0 2ND FLOOR: 0
BASEMENT: 0 1 ST FLOOR: 0 2ND FLOOR: 0
3RD FLOOR: 0 GARAGE 0 DECK 0 OTHER 0 13RD
FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0
BEDROOMS:0 BATHROOMS:O 1
BEDROOMS:0 BATHROOMS:0
FRONTSENBACK SIDESETBACK''SETBACK
REQUIRED: PROPOSED: REQUIRED: PROPOSED 777 REQUIRED: PROPOSED:
HEIGHT ALLOWED:O PROPOSED:O REQUIRED: PROPOSED:
SETBACK NOTES:
1 AGREE TO C MPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED
THEREBY NO P RSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO
WORKMEN'S COMPENSATION INSURANCE AND RCW 18:27.
THIS IPPLI TI IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID.
Released By
ATTENTION
Date
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF
OCCUPANCY HAS BEEN GRANTED. UBC109/ IBCI 10/ IRCI 10.
ONLINE APPLICANT = ASSESSOR OTHER 4A(P
17
STATUS: ISSUED
BLD20170190
• Obtain Electrical Permit from State Department of Labor & Industries. 425-290-1309
• Final approval on a project or final occupancy approval must be granted by the Building Official prior to use or occupancy of
the building or structure. Check the job card for all required City inspections including final project approval and final
occupancy inspections.
• Any request for alternate design, modification, variance or other administrative deviation (hereinafter "variance") from
adopted codes, ordinances or policies must be specifically requested in writing and be called out and identified. Processing
fees for such request shall be established by Council and shall be paid upon submittal and are non-refundable.
• Approval of any plat or plan containing provisions which do not comply with city code and for which avariance has not been
specifically identified, requested and considered by the appropriate city official in accordance with the appropriate provision
of city code or state law does not approve any items not to code specification.
• Sound/Noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits
of ECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on weekdays and 10:00am and 6:00pm on Saturdays, excluding
Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the
noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120.
• Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold
harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of
whatever nature, arising directly or indirectly fi•omthe issuance for this permit. Issuance of this permit shall not be deemed to
modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance
provision.
THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE
PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION.
PERMIT TIME LIMIT: SEE ECDC 19.00.005(A)(6)
BUILDING (425) 771-0220 EXT. 1333 1 ENGINEERING (425) 771-0220 EXT. 1326 1 FIRE (425) 775-7720 1
PUBLIC WORKS 425 771-0235 1 PRETREATMENT 425 672-5755 1 RECYCLING 425 2754801
When calling for an inspection please leave the following information: Permit Number, Job Site Address, Type of Inspection being
requested, Contact Name and Phone Number, Date Prefereed, and whether you prefer morning or afternoon.
• B-First Floor Framing
• B-Plumb Rough In
• B-SheetrockNail
• B-Building Final
DEVELOPMENT SERVICES
RESIDENTIAL BUILDING PERMIT
APPLICATION
Fwlsq,�t 121 5`h Avenue N, Edmonds, WA 98020
City of Edmonds Phone 425.771.0220 4 Fax 425.771.0221
PLEASE REFER TO THE RESIDENTIAL BUILDING CHECKLIST FOR SUBMITTAL REQUIREMENTS
PROJECT ADDRESS (Street, Suite #, City State, Zip):
22-7 0W/KMC. VIati
Parcel #:
Z44*-M00• IbZ00
Subdivision/Lot #:
sP Z�i•lo pT. �Y I I
Project Valuation: $ ' ` �b •�
APPLICANT:
r�t�Tr� 1A �o ry
Phone:
�•zc7• 7?4
I-.
Fax:
Address (Street, City, State, Zip):
�riZ AtVIFUL -7T•
E-Mail Address:
�Gtv►�od►,�i1:�1' rn r� blof�tA,t,l'cc
PROPERJrY OWNER:'
a � Kf•e1-(K ems'
Phone:
Fax:
Address (Street, City, late, Zip):
Z 0 t VLkew DV'.
E-Mail Address:
famiN
LENDING AGENCY:
_!!jne?Xm4er,
Phone:
Fax:
Address (Street, City, State, Zip):
E-Mail Address:
* �y � ��
CONTRACriteykyl ( �Q
Phone: � �
Fax:
�—
Address (Street, City, State, Zip):
I E.l,/w
E-Mail Address:
fi, ,e 4v% h,e It e revi O l 1W • Go bb�.
*Contractor must have a valid City of Edmonds business license prior to
doing work in the City. Contact the City Clerk's Office at 425.775.2525
WA State License #/Exp. Date:
tA) c0 ,lsi9C. e$ o m I'0• Zi • 16
City Business:—icense #/Exp. Date:
DETAIL THE SCOPE OF WORD: Q A l aun vzQ of miz gv.1aiaraAe,
no dK4e �d
PROPOSED NEWSQUARE FOOTAGE
FOR THIS PROJECT:
Basement: s . ft.
Select Basement Type: Finished Ll Unfinished
1" Floor: s . ft.
Garage/Carport: s . ft.
2nd Floor: s . ft.
Deck/Cvrd Porch/Patio: s . ft.
Bedrooms # Full-3/4 Bath # Half -Bath #
Other: s . ft.
Fire Sprinklers: Yes
No
Retaining Wall: Yes F1
No
Grading: Cut cu. yds. Fill cu.yds.
Cut/Fill in Critical Area: Yes No
I declare under penalty of perjury laws that the information I have provided on this form/application is true, correct and
complete, and that I am the property owner or duly authorized agent of the property owner to submit a permit application to
the City of Edmonds.
Print Name: �1\ ��� (tV /'OcIV �" Owner ❑ Agent/Other [O (p cify):
Signature: LVvV1�V1 l 1�� Date: ,,4 -ZI
FORM A LABuilding New Folder 2010\DONE & x-ferred to L-Building-New driveTomi A2014.docx Updated: 1/17/2014
OF. ED`I,0
v Un
DEVELOPMENT SERVICES
_
RESIDENTIAL BUILDING PERMIT
APPLICATION FORM A
Fst 1 goo
121 5 h Avenue N, Edmonds, WA 98020
City of Edmonds
Phone 425.771.02201i Fax 425.771.0221
Equipment Type
Appliance/Equipment Information (new and relocated) Total #
Furnace
Gas #_Elec
# Other:
# BTUs: <100k_ >100k_ Location(s)
Air Handler / VAV
Gas #_Elec
#_Other:
# CFM: <10k_ >10k_ Location(s)
(circle selected)
AC / Compressor /
Boiler / Heat Pump /
Gas #_Elec
#_Other:
# BTUs: <100k, 100k-500k, 500k-1Mil
Roof Top Unit
HP:
<3, 3-15,
15-30 Location(s)
(circle selected)
Hydronic Heating
Gas #_Elec
#_In -Floor
_Wall Radiant_ Boiler BTUs: Location
Exhaust Fans (single
Bath #_Kitchen
#_Laundry # #
duct)
_Other:
Fireplace
Gas #_Elec
#_Other:
#_ Location(s)
Dryer Duct
Appliance Type
Appliance/Equipment Information (new and relocated)
Total #
AC Unit
BTUs:
Location(s):
Furnace
BTUs:
Location(s):
Water Heater
BTUs:
Location(s):
Boiler
BTUs:
Location(s):
Other:
BTUs:
Location(s):
Fireplace/Insert
BTUs:
Location(s):
Stove/Range/Oven
Dryer
,
Outdoor BBQ
TOTAL OUTLETS
PI,UNIBING
Fixture Type (new and relocated)
FIXTURE COUNT
Total # Fixture Type (new and relocated)
Total #
Water Closet (Toilet)
Pressure Reduction Valve/Pressure Regulator
Sink (kitchen, laundry, lavatory, bar, eye wash, etc.)
Water Service Line
Tub/Shower
Drinking Fountain
Dishwasher
Clothes Washer
Hose Bib
Backflow Prevention Device (e.g. RBPA, DCDA, AVB)
Water Heater Tankless? Yes
❑ No ❑
Hydronic Heat in: Floor ❑ Wall ❑
Floor Drain/Floor Sink
Other:
Refrigerator water supply (for water/ice dispenser)
Other:
FORM A LABuilding New Folder 2010\DONE & x-ferred to L-Building-New drive\Form A2014.docx Updated: 1/17/2014
Alterations Worksheet 2015 Washington State Energy Code
Project Information Contact Information
. -4 " . -74'. ill {
The Washington State Energy Code requirements for alterations are located in Chapter 5
Alterations (remodels) do not need to obtain energy credits from Table R406.2
Additions must meet the requirements for new construction. This includes nonconditioned space being
altered to become, conditioned space.
Magnum
Will the wall cavities be exposed? I-P"Yes r- No
If yes: Exposed wall cavities must be insulated - OEM
2 X 4 wall studs require R-15 insulation
2 X 6 wall studs require R-21 insulation
Will the roof/ceiling framing cavities or attic be exposed? I—P,Yes FIN
If yes: Exposed roof/ceiling assemblies must be insulated -
Vaulted ceilings: Insulate to the full depth of the framing member
while allowing for the minimum 1" ventilated space
I/Flat ceilings:
Will the floor framing cavities be exposed?
Install R-49 insulation or what the attic space can
accommodate based on the roof pitch
FL -Yes F No
If yes: Exposed floor cavities must be insulated to R-30
Are the windows and/or doors being replaced? r- Yes r✓No
(includes both window or door and frames)
If yes: New windows and doors must have an area weighted average U-factor of s0.30
Will the heating or' cooling system be replaced? F Yes r✓No
If yes: New equipment must meet current requirements and
ducts need to be tested
Will the hot water system be altered? r- Yes rAo
If yes: New water heating equipment must meet current code requirements
Are more than 50% of the light fixtures being changed? I-" Yes rT/ o
If yes: 75% of all lamps must be high efficacy
(LED or CFL)
CITY COPY RECEIVED
BeamChek v2014 licensed to: HANSON DESIGN Reg # 5234-65302 r9.9 03 2011
SNEERINGER LAUNDRY BEAM DEVELOPMENT. SERVICES
Date: 2/06/17 COUNTER
Selection 5-1/8x 10-1/2 GLB 24F-V4 DF/DF Lu = 0.0 Ft -71
Conditions NDS 2012
Min Bearing Area R1= 2.2 in2 R2= 2.2 in (1.5) DL Defl= 0.11 in Recom Camber- 0.17 in
Data
Attributes
Actual
Critical
Status
Ratio
Values
Adjustments
Loads
Beam Span
13.5 ft
Reaction 1 LL
844 # Reaction 2 LL 844 #
Beam Wt per ft
13.08 #
Reaction 1 TL
1438 # Reaction 2 TL 1438 #
Bm Wt Included
177 #
Maximum V
1438 #
Max Moment
4854'#
Max V (Reduced)
1252 #
TL Max Defl
L / 240
TL Actual Defl
L / 751
LL Max Defl
L / 360
LL Actual Defl
L / >1000
Section (in3)
Shear (W)
TL Defl (in)
LL Defl
94.17
53.81
0.22
0.10
24.27
7.82
0.68
0.45
OK
OK
OK
OK
26%
15%
32%
23%
Fb (psi)
Fv (psi)
E (psi x mil)
Fc! (psi)
Reference Values
2400
240
1.8
650
Adjusted Values
2400
240
1.8
650
Cv Volume
1.000
Cd Duration
1.00
1.00
Cr Repetitive
1.00
Ch Shear Stress
N/A
'Cm Wet Use
1.00
1.00
1.00
1.00
CI Stability
1.0000
Rb = 0.00
Le = 0.00 Ft
Uniform LL: 125 Uniform TL: 200 = A
Uniform Load A
R1 = 1438 R2 = 1438
SPAN =13.5FT
Uniform and partial uniform loads are Ibs per lineal ft.
BeamChek v2014 licensed to: HANSON DESIGN Reg # 5234-65302
SNEERINGER LAUNDRY BEAM
Date: 2/06/17
Selection 3-1/8x 12 GLB 24F-V4 DF/DF Lu = 0.0 Ft
Conditions ' NDS 2012
'Min Bearing Area R1= 2.2 in2 R2= 2.2 in (1.5) DL Defl= 0.12 in Recom Camber-- 0.17 in
Data
Attributes
Actual
Critical
Status
Ratio
Values
Adiustments
Loads
Beam Span
13.5 ft
Reaction 1 LL
844 # Reaction 2 LL 844 #
Beam Wt per ft
9.11 #
Reaction 1 TL
1412 # Reaction 2 TL 1412 #
Bm Wt Included
123 #
Maximum V
1412 #
Max Moment
4764 '#
Max V (Reduced)
1202 #
TL Max Defl
L / 240
TL Actual Defl
L / 700
LL Max Defl
L 1360
LL Actual Defl
L / >1000
Section (in9)
Shear ink
TL Defl (in)
LL Defl
75.00
37.50
0.23
0.12
23.82
7.51
0.68
0.45
OK
OK
OK
OK
32%
20%
34%
26%
rD (psi)
rV (PSI)
t (psl x mll)
rC!
Reference Values
2400
240
1.8
650
Adjusted Values
2400
240
1.8
650
Cv Volume
1.000
Cd Duration
1.00
1.00
Cr Repetitive
1.00
Ch Shear Stress
N/A
Cm Wet Use
1.00
1.00
1.00
1.00
CI Stability
1.0000
Rb = 0.00
Le = 0.00 Ft
Uniform LL: 125 Uniform TL: 200 = A
Uniform Load A
0
R1=1412 R2=1412
SPAN = 13.5 FT
Uniform and partial uniform loads are Ibs per lineal ft.