Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD20170603
'IIli11 18lll Ci y OF F CITY OF EDMONDS 121 5TH AVENUE NORTH - EDMONDS, WA 98020 i o PHONE: (425) 771-0220 - FAX: (425) 771-0221 ne. t 89 STATUS: ISSUED 06/29/2017 Permit #: BLD20170603 BUILDING PERMIT Expiration Date: 12/29/2017 Project Address: 18816 OLYMPIC VIEW DR,' EDMONDS. Parcel No: 27031300413700 APPLICANT CONTRACTOR ROBERT W 11 / KOSCO CAROL SWERK ROBINSON PLUMBING INC ROBINSON PLUMBING INC PO BOX 164 CIO REGINA ROBINSON-ELMSLIE C/O REGINA ROBINSON-ELMSLIE EDMONDS, WA 98020 29330 124TH AVE NE 29330 124TH AVE NE ARLINGTON, WA 982238683 ARLINGTON, WA 982238683 (425)355-6171 (425)355-6171 LICENSE 4: robinp*272c2 EXP:09/01/2017 FLOW THROUGH FIRE SPINKLER SYSTEM FOR NEW SFR VALUATION: $0.00 6imTED PERMIT TYPE: Residential PERMIT GROUP: 30 - Fire Sprinkler GRADING: N CYDS: 0 TYPE OF CONSTRUCTION: RETAINING WALL ROCKERY: OCCUPANT GROUP: OCCUPANT LOAD: FENCE: ( 0 X 0 FT.) CODE: 2015 OTHER: ------- OTHER DESC: ZONE: NUMBER OF STORIES: 0 VESTED DATE: NUMBER OF DWELLING UNITS: 0 ILOT Il: BASEMENT: 0 1 ST FLOOR: 0 2ND FLOOR: 0 1 PO BASEMENT: 0 1 ST FLOOR: 0 2ND FLOOR: 0 3RD FLOOR: 0 GARAGE: 0 DUCK: 0 OTHER: 0 13RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0 BEDROOMS:0 BAT HROOMS:O BEDROOMS:0 BATHROOMS:0 .O REQUIRED: PROPOSED: REQUIRED: PROPOSED: REQUIRED: PROPOSED: HEIGHT ALLOW'ED:0 PROPOSED:O REQUIRED: PROPOSED: SETBACK NOTES: I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS 'PP CATIONS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HISHER DEPUTY AND ALL FEES ARE PAID. off,/Z91Zo7/_'� 6%�a�& Sig at e'' -Print Name Date Released By Date ATTENTION IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. UBC109/ IBC 10/ IRCI 10. ONLINE APPLICANT ASSESSOR 0 0THm l06 c W 4 STATUS: ISSUED BLD20170603 p • Final approval on a projector final occupancy approval must be granted by the Building Official prior to use or occupancy of the building or structure. Check the job card for all required City inspections including final project approval and final occupancy inspections. • Any request for alternate design, modification, variance or other administrative deviation (hereinafter "variance") from adopted codes, ordinances or policies must be specifically requested in writing and be called out and identified. Processing fees for such request shall be established by Council and shall be paid upon submittal and are non-refundable. • Approval of any plat or plan containing provisions which do not comply with city code and for which a variance has not been specifically identified, requested and considered by the appropriate city official in accordance with the appropriate provision of city code or state law does not approve any items not to code specification. • Sound/Noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:00amto 6:00pm on weekdays and 10:00am and 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. • Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of whatever nature, arising directly or indirectly from the issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. INSPECTIONS THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT TIME LIMIT: SEE ECDC 19.00.005(A)(6) CALL FOR INS PECInONS BUILDING 425 771-0220 EXT. 1333 ENGINEERING 425 771-0220 EXT. 1326 FIRE 425 775-7720 PUBLIC WORKS 425 771-0235 1 PRI-TREATNIENT (425) 672-5755 1 RECYCLING 425 275-4801 When calling for an inspection please leave the following information: Permit Number, Job Site Address, Type of Inspection being requested, Contact Name and Phone Number, Date Prefereed, and whether you prefer morning or afternoon. • F-Fire Sprinkler Insulation • F-Fire Sprinkler Bucket Test • F-Fire Sprinkler Acceptance DEVELOPMENT SERVICES RESIDENTIAL BUILDING PERMIT APPLICATION Fst 1 go 121 5 h Avenue N, Edmonds, WA 98020 City of Edmonds Phone 425.771.0220 4 Fax 425.771.0221 f1c I 1 ' _ i PLEASE REFER TO THE RESIDENTIAL BUILDING CHECKLIST FOR SUBMITTAL REQUIREMENTS PROJECT ADDRESS (Street, Suite #, City State, Zip): IPM, oz_/c Parcel #: -L70 3 /3 Do q/3 7oa Subdivision/Lot #: Project Valuation: $ t'O o Sv . 00 APPLICANT: tLe7v /20f3/rr30ov - e t m s t-4 c Phone: Yz-S Sv & 3 y 5- 9 Fax: Address (Street, City, State, Zip): .)--9 t7 E-Mail Address: 4 /�-,sv.�/DLvrn PROPERTY OWNER: S LvA: /c Phone: Fax: Address (Street, City, State, Zip): E-Mail Address: LENDING AGENCY: Phone: Fax: Address (Street, City, State, Zip): E-Mail Address: CONTRACTOR:* rP-ofg/rvsvru /Pt vM 81A-1& / NL Phone: 360 SF03 7 V 6 Z Fax: Address (Street, City, State, Zip): 3 v 1- V771 4v' 1--lE 4-121- 2'z E-Mail Address: go&-JW.-, *Contractor must have a valid City of Edmonds business license prior to doing work in the City. Contact the City Clerk's Office at 425.775.2525 WA State License #/Exp. Date: ?-O8/N * 272 f_ 2- City Business License #/Exp. Date: n//2 -©Z3 S73 DETAIL THE SCOPE OF WORK: 17- /Av/LPRsE F C P•�.r��i �� �ifS 7�m //�. NL�h� C r- e Lt/ /TE/ 4 PROPOSED NEWSQUARE FOOTAGE FOR THIS PROJECT: Basement: s . ft. Select Basement Type: Finished Unfinished Ll Is'Floor: s . ft. Garage/Carport: s . ft. 7 Floor: s . ft. Deck/Cvrd Porch/Patio: s . ft. Bedrooms # Full-3/4 Bath # Half -Bath # Other: s . ft. Fire Sprinklers: Yes No Retaining Wall: Yes No Grading: Cut cu. yds. Fill cu.yds. Cut/Fill in Critical Area: Yes U No LJ I declare under penalty of perjury laws that the information I have provided on this form/application is true, correct and complete, and that I am the property owner or duly authorized agent of the property owner to submit a permit application to the City of Edmonds. Print Name: �t3_l K-f)!�/susst�• - !► cy►1 S L r C Owner ❑Agent/ ther ❑ (specify): P fy) Signature: Date: vs" FORM A LABuilding New Folder 201000NE & x-ferred to L-Building-New driveTorm A2014.docx Updated: 1/17/2014 State of Washington Sprinkler License # Designer: Kenneth H. RO-BI-NP-*272C2, Level 3 Robinson-Elmslie Robinson 29330124th Ave N.E. State of Washington Sprinkler Arlingt n WA 98223 D es Builder: Contour Construction Job: Swerk Residence Property address: 18816 Olympic View Dr., Edmonds Total quantity of sprinkler heads: 47 Fire sprinkler system notes: * Fire sprinkler system design per NFPA 13d (standard for houses and duplexes). * Fire sprinkler system to be pressure tested and flow tested. * Sprinkler piping and fittings to be C.P.V.C. "Flameguard" by Speers Mfg. * Installation of C.P.V.C. pipe and fittings to be done by manufacturer certified installers. * Underground water service to be combination fire and domestic. Sprinkler heads to be Globe Sprinkler Co. "Inch" concealed pendant with escutcheons per listing. SIN # GL4906. If gas fired appliance to be located on deck, head to be Globe GL5641 dry sidewall. * Lines in attic to be protected from freezing with tent insulation (by others). * Sprinkler system to supply water connection for toilets, providing "flow through" in lieu of backflow prevention. Dead end branch lines shall be kept to no more than 20' in length. * Design spacing is 16' x 16' (256 square feet). * Design Density is minimum .05 gpm/square foot * Design area is for 2 head simultaneous flow. * Minimum flow requirements are: 0V (Co V (1) head flow =13 gpm @7.0 psi (flat or sloped ceilings) (2) head flow = 13 gpm (ea) @ 7.0 psi (flat or sloped ceilings) MAY 0 BUILDING JOB: CONTOUR CONSTRUCTION ADDRESS: 18816 OLYMPIC VIEW DR., EDMONDS DESIGNER: KENNETH H. ROBINSON-ELMSLIE CALCULATIONS FOR 26 GPM FLOW (2 HEADS) IND. LOSS NET TOTAL A. WATER PRESSURE IN STREET B: SELECT PIPE SIZE: 1" C: DEDUCT METER & SETTER LOSS (1 ") 12.00 DEDUCT BACKFLOW DEVICE LOSS (NONE) 0.00 D: DEDUCT HEAD LOSS FOR ELEVATION HEIGHT 25 X .434 LBS/FT 10.85 E. DEDUCT PRESSURE LOSS FROM MAIN TO SRINKLER 1-1/4" WATER SERVICE ITEM QUANTITY EQUIV FT. TOTAL FT. PIPE: 175 1 175 ELLS: 8 2 16 R-TEES 7 3 21 B-TEES 3 2 6 TOTAL: 218 TOTAL EQUIVALENT FT. X .03 PSI/FT = 6.54 F: DEDUCT PRESSURE LOSSES FOR 1-1/2" PIPING FROM CONTROL VALVE TO MOST REMOTE SPRINKLER ITEM QUANTITY EQUIV FT. TOTAL FT. PIPE: 0 1 0 ELLS: 0 7 0 R-TEES 0 1 0 B-TEES 0 8 0 TOTAL: 0 TOTAL EQUIVALENT FT. X .0178 PSI/FT = 0 F: DEDUCT PRESSURE LOSSES FOR 1-1/4" PIPING FROM CONTROL VALVE TO MOST REMOTE SPRINKLER ITEM QUANTITY EQUIV FT. TOTAL FT. PIPE: 95 1 95 ELLS: 4 6 24 R-TEES 13 1 13 B-TEES 7 6 42 TOTAL: 174 TOTAL EQUIVALENT FT. X .0343 PSI/FT = 5.9682 F: DEDUCT PRESSURE LOSSES FOR 1" PIPING FROM CONTROL VALVE TO MOST REMOTE SPRINKLER ITEM QUANTITY EQUIV FT. TOTAL FT. PIPE: 24 1 24 ELLS: 3 5 15 R-TEES 3 1 3 B-TEES 2 5 10 TOTAL: 52 TOTAL EQUIVALENT FT. X .1067 PSI/FT = 5.55 F: DEDUCT PRESSURE LOSSES FOR 3/4" PIPING FROM CONTROL VALVE TO MOST REMOTE SPRINKLER ITEM QUANTITY EQUIV FT. TOTAL FT. PIPE: 8 1 8 ELLS: 1 4 4 R-TEES 0 1 0 B-TEES 0 3 0 TOTAL: 12 TOTAL EQUIVALENT FT. X .3220 PSI/FT = 3.86 90.00 78.00 78.00 67.15 60.61 60.61 54.64 49.09 ; WASHINGTON STATE ' CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS . ' Kenneth H. Robinson-Elmslie 7659-0106-CE Level Robinson Plumbing, Inc. _ ROBINP'272C2 S /� j( • i • Expires: 12a1117 igneture . _ . _ Date. •••••••s 45.23 REMAINING PRESSURE FOR SPRINKLER OPERATION 45.23 CALCULATIONS PER NFPA 13D A.10A.3 (A) (2013 ED.) GL bB FIRE SPRINKLER CORPORATION "THE INCH RESIDENTIAL AUTOMATIC SPRINKLERS MODEL GL4906 ONE INCH ADJUSTABLE FLAT PLATE CONCEALED PENDENT DESCRIPTION AND OPERATION The Globe Model GL4906 Residential One Inch Adjustable Concealed Pendent Sprinkler has a flat plate profile that utilizes 3mm frangible glass ampule as the thermosensitive element. Itfeatures economy, aesthetics and the lowest allowable water flow with a nominal 1"of adjustment for easier installation. The combination of the 3mm frangible glass ampule and specially designed deflector make the Model GL4906 the ultimate in life safety and fire control. It has met the strict requirements of Underwriters Laboratories Inc. as described in UL Standard,1626, for Residential Sprinklers for Fire Protection Service, and should be used accordingly. This sprinkler should also be installed in accordance with the appropriate NFPA Standard 13, 13D or 13R and under the direction of the approving authorities having jurisdiction. All that is seen at the ceiling is the 3 5/16" diameter fiat ceiling plate color finished to match the specifrer's exact requirements. The ceiling plate is soldered to the sprinkler's special upper support assembly in three places. Upon the application of sufficient heat, the plate falls to the floor exposing the residential pendent spray sprinkler. Atthe prescribed temperaturethe internal pressure within the ampule exceeds the strength of the glass causing the glass bulb to shatter. This results in water discharge which is distributed in an approved pattern. TECHNICAL DATA See reverse side for Approvals and Specifications. • Temperature Rating: 1550F (68°C) • Water Working Pressure Rating: 175 psi (12 Bars) • Factory tested hydrostatically to 500 psi (34 Bars) • Maximum lowtemperature glass bulb rating: -670F (-55°C) • Frame - bronze • Deflector - brass • Screw - brass • Bulb seat - copper • Spring - nickel alloy • Seal - teflon • Bulb - glass with alcohol based solution, 3mm size • Cover Plate -brass • Upper Escutcheon Assembly- steel RESIDENTIAL FLAT PLATE CONCEALED PENDENT • SPRINKLER TEMPERATURE RATING(CLASSIFICATION and COLOR CODING 4077 AIRPARK DRIVE, STAN DISH, MICH I GAN 48658 989-846.4583 • FAX 989-846-9231 SEPTEMBER 2011 A-10 BULLETIN GL4906, REV. #1 RESIDENTIAL AUTOMATIC SPRINKLERS MODEL GL4906 ONE INCH ADJUSTABLE FLAT PLATE CONCEALED PENDENT SPECIFICATIONS AND APPROVALS SIN NOMINAL 15rF (66°C) MODEL "IC' FACTOR THREAD SIZE LENGTH FINISHES SPRINKLER WITH cULus 136*F SrC PLATE Bright Chrome White Painted GL4906 4.9 (68 metric) 1/2" NPT 3" (7.6 cm) Bright Brass` X X Satin Chrome' Other Painted Finishes` r11VIAF Lb AVAIL AULB ON SPEGIAL ORDER. FOR PAINTED PLATES OTHER THAN WHITE, CONTACT GLOBE FOR ORDERING SPECIFICATIONS. INSTALLATION DATA FOR FLAT AND SLOPED CEILINGS" ONE INCH ADJUSTARt_E Ft AT PI ATF r_nmt RA1 wrk aCINnCWr MODE. MAXIMUM AREA OF COVERAGE MINIMUM WATER DISCHARGE & PRESSURES NEEDED PER SPRINKLER" GL4906 12' x 12' 13 G.P.M. - 7 P.S.I. 14' x 14' 13 G.P.M. - 7 P.S.I. 16' x 16 13 G.P.M. - 7 P.S.I. 18'x19. ....: 17G.P..M.-1.2P,S.I. 2V x 20' 20 G.P.M. -16.7 P.S-I. +.u+c: +•"nnrV+" al arnuvnLti( arA�.ln�- 'WHEN THESE SPRINKLERS ARE USED IN NFPA 13 SYSTEMS, A 0.1 DESIGN DENSITY MINIMUM SHALL BE UTILIZED. —REFER TO PAGE 2OF THE GLOBE RESIDENTIAL SPRINKLER INSTALLATION GUIDE FOR NFPA 13D and 13R REQUIREMENTS. ORDERING INFORMATION CROSS SECTION SPECIFY 2 3/4' DLL FM ---- - HOLE IN CIRM —2 3/r Dra— --{ DROP PIN (>1 M OMPIM PLME J FLAT PLATE CONCEALEDPENDENT GLibBE FIRE SPRINKLER CORPORATION SEPTEMBER2011 MAX M. • Quantity • Model Number • Style • Orifice • Temperatuna • Finishes desired • Quantity - Concealed Wrenches - PIN 332765 • Quantity - Protective Caps - P/N 332868 COVER PLATE SIZE WHITE 136OF PART # CHROME 136OF PART # 3 5/16' 332892 332891 GLOBEO PRODUCT WARRANTY Globe agrees to repair or replace any of its own manu- factured products found to be defective in material or workmanship for a period of one year from date of ship- ment For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846- 583 FAX989-846-9231 1-800-248-0278 www.globesprinkler.com PRINTED U.S.A. BULLETIN GL4906, REV. #1 GLOBE RESIDENTIAL SPRINKLER GUIDE NFPA 13 REQUIREMENTS: When sprinklers are used in NFPA 13 Systems, A 0.1 Design Density minumum shall be utilized. NFPA 130 REQUIREMENTS: For each of the following situations, the number of sprinklers in the design area shall be all of the sprinklers within a compartment, up to a maximum of two sprinklers, that require the greatest hydraulic demand: (1). A flat smooth, horizontal ceiling with no beams up to a maximum of 24 ft. above the floor. (2). A smooth flat, sloped ceiling with no beams up to a maximum slope of 8 in 12. The highest portion of the ceiling shall not be more than 24 ft. above the floor. The highest sprinkler in the sloped portion of the ceiling shall be above all openings from that compartment containing the sloped ceiling into any communicating spaces. (3). A sloped ceiling with beams up to 14 in, deep with pendent sprinklers under the beams. The compartment containing the sloped, beam ceiling shall be a ma)dmum of 600 Win area. The slope of the ceiling shall be between 2 in 12 and 8 in 12. The highest portion of the ceiling shall not be more than 24 ft. above the floor. The highest sprinkler in the sloped portion of the ceiling shall be above all openings from the compartment containing the sloped ceiling into any communicating spaces. (4). A sloped ceiling with beams of any depth with sidewall or pendent sprinklers in each pocket formed by the beams. The compartment containing the sloped, beamed ceiling shall be a maximum of 600 ftx in area. The slope of the ceiling shall be between 2 in 12 and 8 In 12. The highest portion of the ceiling shall not be more than 24 ft above the floor. For situations not meeting one of the conditions above, residential sprinklers listed for use in specific ceiling configurations shall be permitted to be used in accordance with their listings. For situations not meeting one of the conditions above, the number of sprinklers in the design area shall be determined in consultation with the authority having jurisdiction as appropriateforthe conditions. Sprinklers shall be installed in accordance with their listing where a type of ceiling configuration is referenced in the listing. NFPA 13R REQUIREMENTS: Horizontal Ceiling criteria may be used for sloped ceiling configurations up to 8:12 pitch when accept- able to the Local Authority having Jurisdiction. The following pages contain Illustrations for customers reference. If conflicting data is found, NFPA 13,13D, or 13R requirements take presedence. SEPTEMBER 2011 Page 2 BULLETIN R.S.I.G., REV. #15 P.O. Box 3365 South El Monte, CA 917.3-3 626.444.0541 Fax 626.444.3887 WWW. Afcon.org 51.5 DOUBLE OFFSET C.PY.C. HANGER SIZE - 3/4" and l"pipe. MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTINGS - SW EX 4231 PATENT - No. 6,702,M FUNCTION - Hangedrestrainer on CPVC pipe. INSTALLATION - Per N.P.RA 13,13R and 13D on side of beam. FASTENERS - UL Listed per NFPA 13. in WOOD: #904 screw - no pre -drill. in STEEL: 1/4" or#] 4 Tek Screw. FEATURES Double 11/2" offset. Center fine matches AFCOX #514. 314" and I" pipe size have common center -tine. Offiet edge eliminates abrasion - Required AFCON #904 screw has 3/8" hex head - included. ORDERING - Part # and pipe size. 1A MIN - 1/04 INCORPORATED CORONA, CA • (714) 737-5599 32A FIG. 22 HANGER FOR C.P.V.C. PLASTIC PIPE SINGLE FASTENER STRAP TYPE Size Range - 3/4" thru 2" C.P.V.C, pipe.. Material - Carbon Steel with galvanized finish G•90 govt. spec. Function - Figure 22 is intended to perform as a hanger to support only C.P-V.C. piping used in automatic fire sprinkler systems. The product acts as a hanger when tab is upward and the fastener screw is in the horizontal position. Figure 22 can be installed on the top of a beam. but in this situation acts as a guide to the piping which is supported by the beam itself. Figure 22 is not intended to support C.P.V.C. pipe from under a flat horizontal surface, such as a ceiling. For this type of installation use the Tolco Figure 23, Double Fastener Strap Hanger for C.P.V.C. Piping. Figure 22, when inverted, with the hanger tab downward, does not act as a hanger, but can function as a restrainer to prevent the upward movement of the sprinkler head during activation. Approvals - Underwriters' Laboratories listed to support fire sprinkler piping. Meets and exceeds the requirements of N,F.P.A. 13, 13R, and 13D. Features - Figure 22 incorporates features which protect the pipe and ease installation. The flared edge design' protects C.P.V.C. pipe from any rough surface. Figure 22 is easily attached to the building structure using the special hex head self threading screw" furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer) or impact fasteners (such as drive screws or nails) are allowed. Damage has been known to result from installations using impact type tools. No pre drilling of a pilot hole in wood is required. Order By - Figure number and C.P.V.C. pipe size. Patent Pending 'G - Minimum fastener size acceptable, #12 x 1-1/4" hardened hex head self threading screw. � C I A MAX. HANGER FASTENER APPROX. C.P.V.C. SPACING HEX HEAD WEIGHT PIPE SIZE A $ C (FT.) SIZE LENGTH PER 100 3/4 2 - 7/16 1- 5/16 1 - 3/16 5-1/2 5/16 1-1/4 9 a:��.r �Y '�;f-: - ��'a . o�.¢� :.rwu. .;z3-✓3 b�'"`y.`: .�-' Y�.`q�aY.sh :., 1 -1/4 3 - 1/16 1-5/8 1 - 3/16 6-1/2 5/16 1 - 1/4 11 ..•y_,Y. " ay . n yass ^`2i...�: +r�;; ::>` •Y r' ..�.,.,. =?.Y$sR ��.4e���� �a�,sz� ..v �;`rz .a•.f�z'<{.t .. 2 3 3/4 2-1/8 n 1- 3/16 8 5/16 1 1/4 15 Fig. 29 - Double Offset Hanger & Restrainer for CPVC Plastic Pipe Size Range — Available in 314" and 1" pipe sizes Material -- Pre -Galvanized Steel Function — Intended to perform as a hanger and restrainer for CPVC, plastic fire sprinkler pipe. Provides double offset 1 z/a" x : —:��1•500 1 Y2" from mounting surface. This design will ease installation by eliminating the need for wood block extension and allow retro-fit 1; attachment of hanger to sprinkler pipe. Features — • Thumb tab provides protection to restrain pipe in rough job site conditions. Tab is not required to be bent for listed installation. • Offset edge eliminates abrasion. O • Attaches easily to wood structure with two special #10 x 1 hex o head self -threading screws furnished with product. • Can be used as a single offset hanger by aligning "dimples" O with top of mounting surface and utilizing two fasteners in two of the three holes provided. o Approvals — Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL) as a hanger and restrainer to support fire sprinkler systems. Meets and exceeds requirements of NFPA 13, 13R and 13D. Finish — Pre -Galvanized Order By — Figure number and pipe size. PATENT PENDING Install using a rechargeable electric drill fitted with a 5/16" socket attachment with the special hex head self -tapping sixes provided. Install smm until they bottom out. Pipe can be "snapped' into hanger before or after installation of the screvlrs to the mounting surface. "Thumb tab" may be bent up to provide additional protection to the pipe, but is not required for performance of the hanger / restrainer function. C@us 1 L-----------f OifICFJWN FACFURINH FACWTV • 1375 SAMPSON AVE • CORONA. CA 92979" PH: 951.737.5599 • FAX 951,737.0330 CUSTUM SERVICE " 800785 M C� Fig. 28 "Stand -Off" Hanger & Restrainer for CPVC Plastic Pipe Size Range — W through 2" Material — Carbon Steel, Pre -Galvanized Function — Designed to be used as a hanger and restrainer for CPVC piping where the "stand-off' design will ease installation by eliminating the need for wood blocking. Features: • Flared edge design protects CPVC pipe from any rough or abrasive surfaces. • Unique twist and lock design holds pipe firmly in place and allows retrofit type of installation.. • The "Stand-Off"'design eliminates the need for wood block extension. • Can be installed on horizontal or vertical piping regardless of mounting surface orientation: • ' Attaches easily to wood structure with two hex head self -threading screws furnished with product. • Installs easily using rechargeable electrical driver with 5116" extension socket eliminating impact tool damage to pipe. • Attaches easily to steel, minimum 18 gauge with (2)1/4' x 1" tek type self drilling tapping screws. • UL Listed as a hanger and a restrainer for fire sprinkler piping. Approvals -- Underwriters' Laboratory Listed in the USA (UL) and Canada (cUL) to support automatic fire sprinkler systems. May be installed into wood using fasteners supplied with product, or into minimum 18 gauge steel using (2) 114" x 1" tek type screws. Meets and exceeds the requirements of NFPA 113,1311 and 131). Fig. 28 satis- fies the UL vertical restraint requirement where needed. UL Listed as a hanger and ver- tical restraint when installed on 3/8" composite wood material. Use two Fig. 27B Speed Nuts when used as a hanger and restraint. Use one Fig. 27B Speed Nut on the upper installed screw when used as a hanger only. Order by — Figure number and pipe size. PATENT # 7,455,268 (fjfiYfUAM"tAEO' = Fl67Te AhNGERaRESIRWr APJL(oA`l N _._,_...... {mot........_.... o•�j �.. __..-_::,.._......_ V� fKi2K---' � E Fan _ --........,__-.__.-_ .•. A)US ..,.fFt Er•. _ Dimensions • Weights ze Approx. size A B C 3/4 31A2 2 31A .180 1 35A6 2M6 31h .210 11/4 35A 23A 31A .225 11h 4 21h Th .310 2 41A 21Y4 3% .340 FAC1LM • 1375 SAMMON AVE. • CORONA CA 9M • PH: 951.737.5599 • FAX: 951.737.0330 4USTOIMER SERVKZ • 800.788.52% wwwwmcw TO 50 0 INCORPORATED 32B C� ' _•iiA CA . 1714! 737-5599 FIG. 23 HANGER FOR C.P.V. C. PLASTIC PIPE DOUBLE FASTENER STRAP TYPE log A _.:_ Size Range - 3/4" thru 2" C.P.V.C. pipe. Material - Carbon Steel with galvanized finish G-90 govt. spec. Function - The Fig. 23 and Fig. 24 are intended to perform as a hanger / restrainer to support only C.P.V.C. piping used in automatic fire sprinkler systems. Fig. 23 and Fig. 24 can be installed on the top or on the bottom of a beam. The Fig. 23 can also be installed on the side of a beam. The Fig. 23. and Fig. 24 can also function as a restrainer to prevent the upward movement of the sprinkler head during activation. Approvals - Underwriters' Laboratories listed to support fire sprinkler piping. Meets and exceeds the requirements of N.F.P.A. 13, 13R, and 13D. PIPE SIZE IFIG. 23 FIG. 24 FIG. 23 FIG: 24 ; FIG. 23 FIG. 3/4 1 3-1/8 2-5/16 1-9/16 1-5/32 . 1-3/16 1-3/ 1-1/4 4-3/16 3 ;2-3/32 1-1/2 1-3/16 1- FIG. 24 HANGER FOR C.P.V.C. PLASTIC PIPE DOUBLE FASTENER STRAP TYPE — SIDE MOUNT I� A '1 Features - The Fig. 23 and Fig. 24 incorporate features which protect the pipe and ease installation. The flared edge design" protects the C.P.V.C_ pipe from any rough surface. The Fig. 23 and Fig. 24 are easily attached to the building structure using the two hex head self threading screws` furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer) or impact fasteners (such as drive screws or nails) are allowed. Damage has been known to result from installations using impact type tools. No pre drilling of a pilot hole in wood is required., Order By - Figure number and C.P.V.C. pipe size. ° Patents Pending - Minimum fastener size acceptable, #12 x 1-1/4" hardened hex head self threading screw. MAX. HANGER FASTENER 1 APPROX. SPACING HEX HEAD I WEIGHT (FT.) SIZE _t LENGTH PER 100 5-1/2 5/16 I 1-1/4 9 6-1/2 1 5/16- .' 1 1-1/4 i 11 2 4-78 3-11/16 2-7/16 1-27/3q1-3/16 1- 8 i -- 5/16 1-1/4 1 15 Fig: 28M Offset Hanger andAestrainer for CPVC Plastic Pipe and IRS Pipe Size Range — 3/4" thru 1-4/4" pipe Material — Carbon Steel; Electro-Galvanized Function -- Designed to be used as a hanger,and restrainer for CPVC piping where the "stand-off' design will ease installation by eliminating the need for wood blocking Features — • Flared edge design protects C.PVC pipe from any rough or abrasive surfaces • Unique snap -on design holds pipe firmly in place and allows retrofit type of installation • The "Stand -Off" design elimiriates the need for wood block extension • Can be installed on horizontal or vertical piping regardless of mounting surface orientation • Attaches easily to wood structure with two hex head self -threading screws fumished with product • Installs easily using rechargeable electrical driver with 5/16" extension socket eliminating impact tool damage to pipe • Attaches easily °to .steel, minimum 18 gauge with (2) 1/4" x 1" tek type self drilling tapping screws • cULus Listed as a hanger and a restrainer for fire sprinkler piping Approvals = Underwriters' Laboratory Listed in the USA (UQ and Canada (cUL) to support automatic fire sprinkler systems. May be installed into wood using fas- teners screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Fig. 28M satisfies the UL vertical restraint requirements where needed. Order By — Figure number and pipe size PATENT PENDING ---------------- d t � t I � t 1 � I L'--- RESTRAINT Fig. 28M Dimensions • Weiahts Ma)c. Spacing Pipe required per Approx Size A B C NFPA 13 for WL/100 CPVC plastic pipe 314 2 3/16 3-1/2 5'-W 9 1 2-1/8 3/16 3-1/2 6'-0" 12 1-1/4 2-5116 3116 3-1/2 6'-6" 13 C@V3 LWW RESTRAINT wW OiWF.NiUMM KMnM WQ FACILM • 1375 SAMPMN AVE • CORONA, CA 9W9 • PH- 951.737.M • FAX: 951.737.0330 CUSTOMER SERVICE • B00.78&5M t 7 Friction Loss (PSI per Linear Foot) and Velocity (Feet per second) (Hazen -Williams C Factor = 150) Nominal Pipe Size: 3/41nch 1 inch 11/4 inches 11/z inches 2 inches 21/z inches 3 Inches Avp.1.D. (Inches) (M4) (1.109} (1.400) (1.602) (2.003) (2.423) (2.951) Friction Friction Friction Friction Fricuon Friction GPM loss Velocity Loss Velocity Loss Velocity Loss Velocity Loss Velocity Loss Velocity .Friction . Loss Velocity 1 .0008 .5 .0003 .3 .0001 .2 _OU00 .1 .0000 .1 .0000 .0 .0000 .0 2 .0028 1.0 .0009 .6 .0003 .4 .0002 .3 .0001 .2 .0000 .1 .0000 .0 3 .0059 1.5 .0020 .9 .0006 .6 .0003 .4 .0001 .3 .0000 .2 0000 .1 4 .0101 2.0 .0033 1.3 .0011 .8 .0006 .6 .0002 .4 .0001 .2 .0000 .1 5 .0152 2.6 .0051 1.6 .0016 1.0 .0008 .7 .0003 .5 .0001 .3 .0000 .2 6 .0214 3.1 .0071 1.9 .0023 1.2 .0012 .9 .0004 .6 .0002 .4 .0001 .2 7 .0284 3.6 .0094 2.3 .0030 1.4 .0016 1.1 .0005 .7 .0002 .4 .0001 .3 8 .0364 4.1 .0121 2.6 .0039 1.6 .0020 1.2 .0007 .8 .0003 .5 .0001 .3 9 .0452 4.7 .0150 2.9 .0048 1.8 .0025 1.4 .0008 .9 .0003 .6 .0001 .4 10 .0550 5.2 .0182 3.3 _0059 2.0 .0030 1.5 .0010 1.0. .0004 .6 .0002 .4 11 .0656 5.7 .0217 3.6 .0070 2.2 .0036 1.7 .0012 1.1 .0005 .7 ,0002 .5 12 .0770 6.2 .0255 3.9 .0082 2.5 .0043 1.9 .0014 1.2 .0006 .8 .0002 .5 13 .0893 6.7 .0296 4.3 .0095 2.7 .0049 2.0 .0017 1.3 .0007 .9 .0003 .6 14 .1024 7.3 .0340 4.6 .0109 2.9 .0057 2.2 .0019 1.4 .0008 .9 .0003 .6 15 .1164 7.8 .0386 4.9 .0124 3.1 .0064 2.3 .0022 1.5 .0009 1.0 .0003 .7 16 .1312 8.3 .0435 5.3 .0140 3.3 .0072 2.5 .0024 1.6 .0010 1.1 .0004 .7 17 .1467 8.8 .0486 5.6 .0156 3.5 .0081 2.7 .0027 1.7 .0011 1.1 .0004 .7 18 .1631 9.4 .0541 5.9 .0174 3.7 .0090 2.8 .0030 1.8 .0012 1.2 .0005 .8 19 .1802 9.9 .0597 6.3 .0192 3.9 .0100 3.0 .0034 1.9 .0013 1.3 .0005 .8 20 .1982 10.4 .0657 6.6 .0211 4.1 .0110 3.1 .0037 2.0 .0015 1.3 .0006 .9 21 .2169 10.9 .0719 6.9 .0231 4.3 .0120 3.3 .0040 2.1 .0016 1.4 .0006 .9 22 .2364 11.5 .0783 7.3 .0252 4.5 .0131 3.5 .0044 2.2 .0017 1.5 .0007 1.0 23 .2567 12.0 .0851 7.6 .0273 4.7 .0142 3.6 .0048 2.3 .0019 1.6 .0007 1.0 24 .2777 12.5 .0920 7.9 .0296 5.0 .0153 3.8 .0052 2.4 .0020 1.6 .0008 1,1 25 .2995 13.0 .0993 8.3 .0319 5.2 .0166 3.9 .0056 2.5 .0022 1.7 .0008 1.1 26 .3220 13.5 .1067 8.6 .0343 5.4 .0178 4.1 .0060 2.6 .0024 1.8 .0009 1.2 27 .3453 14.1 .1144 8.9 .0368 5.6 .0191 4.2 .0064 2.7 .0025 1.8 .0010 1.2 28 .3693 14.6 .1224 9.3 .0394 5.8 .0204 4.4 .0069 2.8 .0027 1.9 .0010 1.3 29 .3941 15.1 .1306 9.6 .0420 6.0 .0218 4.6 .0073 2.9 .0029 2.0 .0011 1.3 30 .4196 15.6 .1391 9.9 .0447 6.2 .0232 4.7 .0078 3.0 .0031 2.0 .0012 1.4 31 .4458 16.2 A478 10.2 .0475 6.4 .0246 4,9 .0083 3.1 .0033 2.1 .0013 1.4 32 .4728 16.7 .1567 10.6 .0504 6.6 .0261 5.0 .0088 3.2 .0035 2.2 .0013 1.5 33 .5005 17.2 . M9 10.9 .0533 6.8 .0277 5.2 .0093 3.3 .0037 2.2 .0014 1.5 34 .5289 17.7 .1753 11.2 .0564 7.0 .0292 5.4 .0098 3.4 .0039 2.3 .0015 1.5 35 .5580 18.2 .1850 11.6 .0595 7.2 .0308. 5.5 .0104 3.5 .0041 2.4 .0016 1.6 36 .5879 18.8 .1949 11.9 .0626 7.5 .0325 5.7 .0109 3.6 .0043 2.5 .0017 1.6 37 .6195 19.3 .2050. 12.2 .0659 .7.7 .0342 6.8 .0116 3.7 .0046 2.5 .0017 1.7 38 .6498 19.8 .2154 12.6 .0692 7.9 .0359 6.0 .0121 3.8 .0048 2.6 .0018 1.7 39 .6817 20.3 .2260 12.9 .0726 8.1 .0377 6.2 .0127 3.9 .0050 2.7 .0019 1.8 40 .7144 20.9. .2368 13.2 .0761 8.3 .0395 6.3 .0133 4.0 .0053 2.7 .0020 1.8 GPM 41 .2479 13.6 .0797 8.5 .0413 6.5 .0139 4.1 .0055 2.8 .0021 1.9 42 .2592 13.9 .0833 8.7 .0432 6.6 .0146 4.2 .0058 2.9 .0022 1.9 43 .2707 14.2 .0870 8.9 .0451 6.8 .0152 4.3 .0060 2.9 .0023 2.0 44 .2824 14.6 .0908 9.1 .0471 7.0 .0159 4.4 _0063 3.0 .0024 2.0 45 .2944 14.9 .0947 9.3 .0491 7.1 .0165 4.5 .0065 3.1 .0025 2.1 46 .3067 15.2 .0986 9.5 .0511 7.3 .0172 4.6 .0068 3.2 .0026 2.1 47 .3191 15.6 .1026 9.7 .0532 7.4 .0179 4.7 _0071 -3.2 .0027 2.2 48 :3318 15.9 .1067 10.0 .0553 7.6 .0186 4.8 .0074 3.3 .0028 2.2 49 .3447 16.2 .1108 10.2 .0575 7.7 .0194 4.9 .0077 3.4 .0029 2.2 50 .3578 16.6 .1150 10.4 .0597 7.9 .0201 5.0 .0080 3.4 .0030 2.3 52 .3847 17.2 .1237 10.8 .0642 8.2 .0216 5.2 .0086 3.6 .0033 2.4 54 .4126 17.9 .1326 11.2 .0688 8.5 .0232 5.4 .0092 3.7 .0035 2.5 56 .4413 18.6 .1419 11.6 .0736 8.9 .0248 5.7 .0098 3.8 .0038 2.6 58 .4709 19.2 .1514 12.0 .0785 9.2 .0265 5.9 .0105 4.0 .0040 2.7 60 .5013 19.9 .1612 12.5 .0836 9.5 .0282 6.1 .0111 4.1 .0043 2.8 62 .5327 20.5 .1713 12.9 .0888 9.8 .0299 6.3 .0118 4.3 .0045 2.9 64 .5649 21.2 .1816 13.3 .0942 10.1 .0317 6.5 .0126 4.4 .0048 3.0 66 .5980 21.9 .1923 13.7 .0997 10.5 .0336 6.7 .0133 4.5 .0051 3.0 68 .6320 22.5 .2032 14.1 .1054 10.8 .0355 6.9 .0141 4.7 .0054 3.1 70 .6668 23.2 .2144 14.5 .1112 11.1 .0375 7.1 .0148 4.8 .0057 3.2 .72 .7025 23.9 .2258 15.0 .1171 11.4 .0395 7.3 .0156 5.0 .0060 3.3 74 .7390 24.5 .2376 15.4 .1232 11.7 .0415 7.5 .0164 5.1 .0063 3.4 76 .7764 25.2 .2496 15.8 .1295 12.0 .0436 7.7 .0173 5.2 .0066 3.5 78 .8146 25.9 .2619 16.2 .1358 12.4 .0458 7.9 _0181 5.4 .0069 3.6 80 .8536 26.5 .2744 16.6 .1424 12.7 .0480 8.1 .0190 5.5 .0073 3.7 Engineering Data Pipe and Fitting Speciffcatiens Spearse FlameGuard® CPVC Sprinkler Pipe is produced in SDR 13.5 dimensions, as specified in ASTM F 442. Engineering data on Material Properties and Expansion & Contraction are provided in this manual for (A) Spears® FlameGuard® or Victaulic Firel-ock® and (B) Harvel BlazeMasterO CPVC Fire Sprinkler Pipe. Consult other manufacturers for applicable variations Spears® FlameGuard® CPVC Sprinkler Fittings are produced in Schedule 40 and Schedule 80 dimensions for sizes 3/4" through 1-1 /4", and in Schedule 80 for sizes 1-1/2" through 3", in accordance with ASTM F 437, ASTM F 438, and ASTM F 439 as applicable. These products are UL Listed FM/Approved for a rated working pressure of 175 psi (1200kPa)at 1500 F (650 C) for sprinkler service and LPCB listed for a rated working pressure of 175 psi (1200kPa) at 120° F (49° C). CPVC Fire Sprinkler Pipe dimensions SDR 13.5 (Ref. ASTM F442) Weight Ibs/ft (kg/m) Size Average Average Nominal inches OD inches (mm) ID inches 3/4 1.050 0.874 0.168 (DN20) (26,7) (22,5) (0,2) 1 1.315 1.101 0.262 (DN25) (33,4) (28,2) (0,4) 1-1/4 1.660 1.394 0.418 (DN32) (42,2) (35,6) (0,6) 1-1/2 1.900 1.598 0.548 (DN40) (48,3) (40,7) (0,7) 2 2.375 2.003 0.859 (DN50) (60,3) (50,9) (1,2) 2-1/2 2.875 2.423 1.257 (DN65) (73,0) (61,5) (1,2) 3 3.500 2.950 1.867 (DN80) (88,9) (75,0) (1,2) Hydraulic Design Hydraulic calculations for the sizing of systems incorporating Spears® FlameGuardO CPVC Fire Sprinkler Products must be calculated using a Hazen -Williams C value of 150. Pipe friction loss calculations must be made according to NFPA Standard 13. The following table shows the allowance for friction loss for fittings, expressed as equivalent length of pipe. For additional information regarding friction loss, contact Spears®. FG-3-1010 © 2010 Spears® Manufacturing Company Page 37 Mewance for F>I don less in Ftttl N Equivalent Feet (meters) of Pipe 314" 26,7 mm V 33,7 mm 1-1/4" 42,4 mm 1-1/2" 48,3 mm 2' 60,3 mm 2-112" 73,0 mm 3" 88,9 mm Tee Run 1(0,3) 1(0,3) 1(0,3) 1(0,3) 1(0,3) 2(0,6) 2(0,6) Tee Branch 3(0,9) 5(1,5) 6(1,8) 8(2,4) 10(3,1) 12(3,7) 15(4,6) 90- Elbow 4(1,2) 5(1,5) 6 (1,8) 7(2,1) 9(2,7) 12(3,7) 13 (4,0) 45° Elbow 1(0,3) 1(0,3) 2 (0,6) 2(0,6) 2(0,6) 3 (0,9) 4 (1,2) Coupling 1(0,3) 1(0,3) 1(0,3) 1(0,3) 1(0,3) 2 (0,6) 2 (0,6) Hangers & Supports Since CPVC Fire Sprinkler pipe is rigid, it requires fewersupports than flexible, plastic systems. Spears® recommends use of hangers that are designed and listed for supporting the CPVC Fire Sprinkler pipe. However, some hangers designed for steel pipe may be used if their suitability is clearly established. These hangers must have a minimum 1/2Anch, load -bearing surface, and they must be selected to accommodate the specific pipe size. In addition, they cannot contain rough or sharp edges that contact the pipe, and they must not bind the pipe from axial movement. Vertical runs must be supported so that the weight of the run is not on a fitting or a joint. Horizontal runs must be braced so that the stress loads (caused by bending or snaking pipe) will not be placed on a fitting or a joint. Support spacing is shown in the following table. See 'Snaking/Deflection of Pipe" in this manual for information regarding bending or snaking CPVC Fire Sprinkler Pipe. Pipe Size Nominal inches Maximum Support Spacing feet (meters) ► t. Water Filled Pipe lbslft (kg/m) 3/4 (DN20) 5-1/2 (1,7) 0.427 (0,6) 1 (DN25) 6(1,8) 0,674 (0,9) 1-1/4 (DN32) 6-112 (2,0) 1.078 (1,5) 1-1/2 (DN40) 7(2,1) 1.412 (1,9) 2 (DN50) 8(2,4) 2.223 (3,0) 2-1/2 (DN65) 9(2,7) 3.254 (61,5) 3 (DN80) 10 (3,0) 4.831(75,0) Page 38 © 2010 Spears® Manufacturing Company FG-3-1010 NFPA 13D permits "support methods comparable to those required by local plumbing codes." The above hanger/support requirements must also be followed on NFPA 13D systems. CAUTION: DO NOT use hanger items such as plumber's tape or 'nail -on" devices. Pipe hanger must comply with NFPA 13,13D and 13R. When a sprinkler head activates, a significant reactive force can be exerted on the pipe. With a pendent head, this reactive force can cause the pipe to lift vertically if it is not secured properly, especially if the sprinkler drop is from small diameter pipe. The pipe must be braced against the vertical lift -up with the closest hanger. Refer to the following illustration and Table A & B. Li raSupportr Ott. hw cowncg Une Table A - Maximum Support Spacing Distance End line SpriuMer Read Drop ®bow Pipe Size Nominal inches Line Pressure <100 psi (<689kPa) Line Pressure >100 psi (>689kPa) 3/4 (DN20) 9 inches (228,6 mm) 6 inches (168,3 mm) 1 (DN25) 12 inches (304,8 mm) 9 inches (228,6 mm) 1-1/4 (DN32) 16 inches (406,4 mm) 12 inches (304,8 mm) 1-1/2 - 3 (DN40 - DN80) 24 inches (610,0 mm) 12 inches (304,8 mm) Note: Support spacing can be increased by approximately 50% for lower pressures. Table B - Maximum Support Spacing Distance 1nline Sprinider Read Drop Tee Pipe Size . Nominal inches Line Pressure <100 psi (<689kPa) Line Pressure >100 psi (>689kPa) 3/4 (DN20) 4 feet (1,22 meters) 3 feet* (0,91 meters) 1 (DN25) 5 feet.(1,52 meters) 4 feet* (1,22 meters) 1-1/4 (DN32) 6 feet (1,83 meters) 5 feet* (1,52 meters) 1-1/2 - 3 (DN40 - DN80) 7 feet (2,13 meters) 7 feet (2,13 meters) Note: *Support spacing can be increased by one foot for lower pressures. FG-3-1010 0 2010 Spears® Manufacturing Company Page 39