Loading...
BLD20170734 - Khatib Addition - E1.pdf CITY OF EDMONDS PLAN REVIEW COMMENTS ENGINEERING DIVISION (425) 771-0220 City Website: www.edmondswa.gov DATE:June 13, 2017 TO:Montaser Khatib cameljockey@yahoo.com FROM:Mitch Boyd, Stantec Consulting Services Mitch.Boyd@edmondswa.gov RE:Application #: BLD20170734 Project:Khatib-Addition th Project Address: 20826 80Ave W During review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Reviews by other divisions, such as Planning, Building, or Fire may result in additional comments. Please submit two (2)sets of revised plans/documents including a written response to each item below. nd Resubmittals can be made at the Development Services Department on the 2floor of City Hall. Permit Center hours are M, T, Th & F from 8am-4:30pmand on Wednesdays from 8:30am-noon. City of Edmonds handouts, standard details, application and other forms, and development code may be referenced on the City website: www.edmondswa.govunder Services/Permits and Development. SITE PLAN 1)Show all City utilities that are adjacent to the site. 2)Please add a note to the plans indicating how existing water service and storm service will be protected during the demolition and construction phases of the project. 3)Sewer cleanouts are required on each side of the proposed garage and proposed outdoor addition to maintain access to the existing sewer. 4)After measuring the proposed impervious areas, it appears that the impervious table calculations may be incomplete. Please clearly show within the table the proposed impervious area for each addition area.This should include the front porch area and the small impervious additionon the south side of the property. CSPPP PLAN 1)Filter fence is not required on the upstream end of the project. ReferenceCity standard detail E1.1. 2)Please add a note to the plans indicating the existing driveway to be used as the construction entrance. Alternatively, show construction entranceon the plans and incorporate and referenceCity standard detail E1.2. 3)Reference City standard detail E1.3. 4)Add a note that the stockpile is to be covered within 24 hours 5)Please add a note to the plans that all disturbed soils will be compost amendedper BMP T5.13. Page 2of 2