Loading...
BLD20171499 (2)of EbAfoi _ ° CITY OF EDMONDS 121 5TH AVENUE NORTH -EDMONDS, WA 98020 lnc. 1 890 PHONE: (425) 771-0220 - FAX: (425) 771-0221 STATUS: ISSUED 11/15/2017 Permit #: BLD20171499 BUILDING PERMIT Expiration Date: 05/15/2018 Project Address: 9401 234TH ST SW, EDMONDS Parcel No: 27033600109800 .11.i I 1 1. ALFRED J YOUNG WESTERN STATES FIRE PRTCTN CO WESTERN STATES FIRE PRTCTN CO 9333 234TH SW C/O EUGENE POSTMA C/O EUGENE POSTMA EDMONDS, WA 98020 14690 NE 95TH ST STE 101 14690 NE 95TH ST STE 101 REDMOND, WA 98052 REDMOND, WA 98052 (425)881-0100 (425)881-0100 LICENSE #: WEST ESF906P1 I EXP:11/09/2018 It DESCRIPTION 777777 Install new NFPA 13 D F/S system w/28 heads in new SFR rift A VALUATION: $0 a Ng-OiL PERMIT TYPE: Residential PERMIT GROUP: 30 GRADING: N CYDS: 0 TYPE OF CONSTRUCTION: RETAINING WALL ROCKERY: OCCUPANT GROUP: OCCUPANT LOAD: FENCE: ( 0 X 0 FT.) CODE: OTHER: ------- OTHER DESC: ZONE: NUMBER OF STORIES: 0 1 VESTED DATE: NUMBER OF DWELLINGUNITS: 0 ILOT #: E-XISTINIG AREA BASEMENT: 0 1 ST FLOOR: 0 2ND FLOOR: 0 1 PO S ED AR EA BASE-MENT: 0 1 ST FLOOR: 0 2ND FLOOR: 0 3RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0 3RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0 BEDROOMS: 0 BATHROOMS: 0 BEDROOMS 0 BATHROOMS: 0 FRONTi•CK SIDESETBACK REARSETBACK REQUIRED: PROPOSED: REQUIRED: PROPOSED: REQUIRED: PROPOSED: HEIGHT ALLOWED:O PROPOSED:O REQUIRED: PROPOSED: SETBACK NOTES: I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18:27. THIS CATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. Print Releas ATTENTION IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. UBC109/ IBC I 101IRCI 10. = FIRE = APPLICANT = ASSESSOR CITY STATUS: ISSUED BLD20171499 • Final approval on a projector final occupancy approval must be granted by the Building Official prior to use or occupancy of the building or structure. Check the job card for all required City inspections including final project approval and final occupancy inspections. • Any request for alternate design, modification, variance or other administrative deviation (hereinafter "variance") from adopted codes, ordinances or policies must be specifically requested in writing and be called out and identified. Processing fees for such request shall be established by Council and shall be paid upon submittal and are non-refundable. • Approval of any plat or plan containing provisions which do not comply with city code and for which a variance has not been specifically identified, requested and considered by the appropriate city official in accordance with the appropriate provision of city code or state law does not approve any items not to code specification. • Sound/Noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits ofECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on weekdays and 10:00am and 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. • Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of whatever nature, arising directly or indirectly from the issuance for this permit. issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT TIME LIMIT: SEE ECDC 19.00.005(A)(6) TO SCHEDULE INSPECTIONS BUILDING ENGINEERING (425) 771-0220 EXT. 1326 1. Go to: www.edmondswa.gov Building Department Inspections 2. Then: Services are now scheduled online. If you FIRE (425) 775-7720 3. Then: Permits/Development have difficulties, please call the 4. Then: Online Permit Info Building Department front desk for PUBLIC WORKS (425) 771-0235 5: If you don't have one already, create a assistance during office hours. login (upper right hand corner) (425) 771-0220 RECYCLING (425) 276-4801 6: Schedule your inspection When calling for an inspection please leave the following information: Permit Number, Job Site Address, Type of Inspection being requested, Contact Name and Phone Number, Date Preferred, and whether you prefer morning or afternoon. • F-Fire Sprinkler Insulation • F-Fire Sprinkler Bucket Test • F-Fire Sprinkler Pressure Test • F-Fire Sprinkler Acceptance • F-Fire Final � � U DEVELOPMENT SERVICES RESIDENTIAL BUILDING PERMIT APPLICATION FSt 1 gqo 121 51h Avenue N, Edmonds, WA 98020 City of Edmonds Phone 425,771.0220 ft Fax 425.771.0221 q 0, PLEASE REFER TO THE RESIDENTIAL BUILDING CHECKLIST FOR SUBMITTAL REQUIREMENTS PROJECT ADDRESS (Street, Suite #, City State, Zip): Parcel #: ,.4a#1 234TH ST SW EDMONDS, WA 98020 27033600109800 Subdivision/Lot #: Project Valuation: $ 1 7,921.00 APPLICANT: Phone: Fax: WESTERN STATES FIRE PROTECTION 425-881-0100 925-881-3030 Address (Street, City, State, Zip): E-Mail Address: 14690 NE 95TH ST #101 REDMOND, WA 98052 JERRY.GOIN@WSFP.US PROPERTY OWNER: Phone: Fax: 2JG LLC 206-920-2903 Address (Street, City, State, Zip): E-Mail Address: 7500 ROOSEVELT WAY NE SEATTLE, WA 98115 LENDING AGENCY: Phone: Fax: Address (Street, City, State, Zip): E-Mail Address: CONTRACTOR:* Phone: Fax: 14690 NE 95TH ST #101 REDMOND, WA 98052 425-881-0100 425-881-3030 Address (Street, City, State, Zip): E-Mail Address: JERRY.GOIN@WSFP.US WA State License #/Exp. Date: *Contractor must have a valid City of Edmonds business license prior to WESTESF136QF / 12-31-17 doing work in the City. Contact the City Clerk's Office at 425.775.2525 City Business License #/Exp. Date: NR-023343 / 12-31-17 DETAIL THE SCOPE OF WORK: INSTALL NEW NFPA 13D FIRE SPRINKLER SYSTEM W/ 28 HEADS IN NEW SFR PROPOSED NEW SQUARE FOOTAGE FOR THIS PROJECT: Basement: sq. ft. Select Basement Type: Finished LJ Unfinished 1" Floor: 1287 sq. ft. Gara e/Car ort: sq. ft. 2°d Floor: 1603 —sq. ft. Deck/Cvrd Porch/Patio: sq. ft. Bedrooms # 4 Full-3/4 Bath # 3 Half -Bath # Other: sq. ft. Fire Sprinklers: Yes LJ No L Retaining Wall: Yes No LJ Grading: Cut cu. yds. Fill cu.yds. Cut/Fill in Critical Area: Yes 0 No I declare under penalty of perjury laws that the information I have provided on this form/application is true, correct and complete, and that I am the property owner or duly authorized agent of the property owner to submit a permit application to tine City of Edmonds. Print Name: JERRY GOIN Owner ❑ Agent/Other ❑ (specify): CONTRACTOR Signature: Date: 10-30-17 FORM A LABuilding New Folder 2010\DONE & x-ferred to L-Building-New driveTorm A2014.docx Updated: 1/17/2014 Hydraulic Summary Job Number: KH1059. Rla, Job Job Number KH1059 Design np w JERRY GOIN Job Name: YOUNG SHORT PLAT LOT 1 Stela Cerlif aU `,.nse Number WESTESF136QF Address, 9401 234TH ST SW AHJ CITY OF EDMONDS -Address 2 Job SitelBulldkp YOUNG SHORT PLAT LOT 1 Address 3 Draw'v,p Nome EDMONDS, WA 98020 YOUNG SHORT PLAT LOT 1 - KH1059.cad System Remote Area,(s) Most Demar,din Sp idler Data 0 .p—y Job suffix 4.9 K-Factor 13.00 at 7.039 Residential Hose Allowance At Souris D—ity Area of AppoosGp, 100.00 0.050gpm/ft2 256.00ft= (Actual 205.04112) Additional Hose Supplies Number Of Sprinklen Calculated Covereye Per Sprinlde, Node Flow m 2 256.00ft' —.P.. R—st: P..... For Remote Adjacent To Meet Remote Area Right: 38.742 {Trwawwsaws�rwwp_rwsrrrmrrslwrrlsq ■ WASHINfL"Id STATE ■ GIUMFIGATE OF OQNXEiEgCY a Film PROTEC [7OId Smum= SYSTLms e ANTHONY MICHAEL GEIST 6781-0715-C LEVEL 3 i WESTERN STATES FIRE PROTECTION CO Total Hose St— 100.00 WEST MF136QF ■ es i■ ■ System i Damnnd Tolel Water Rwlu4ad V—din close Atts--) 26.04 126.04 10/30/17 roe ■ o MIA-Proasure Unbalance In loops 0.000 ■ ■ s�nabura► onto t=1A ■ e d�r�rlwtrwr4wwwrwwwrr•rww rr rrFs>� Maximwn Valodtty Aoove Orcurd 8.78 between nodes 1 and 2 Maximum V.1.fty UM., O-d 4.17 between nodes 3 and 4 V.I....,.city of Wet Plpes Vol ume.paolty of Dry Pipes 70.07gal Supplies Hose Flow Static Residual Flow Available Total Demand Required Safety Margin Node Name m (psi)(psi)co m(psi)oc m(Mil si 1 Water Supply 100.00 61.000 20.000 500.00 1 57.796 1 126.04 38.052 19.745 CRIN GK( R ECC� IF. OWED OCT 3 0 2017 BUILDING Contractor Cont,act. Number KH1059 Cmlad Name Jerry Goin Contact Ttle Project Manager Nam° of Contractor: Western States Fire Protection Co. Pi,.. 425-881-0100 Edansun Address , 14690 N.E. 95th Street, Unit 101 FAX 425-881-3030 Add.. Y Redmond, WA 98052 1 jerry.goin@wsfp.us Address 3 Wab-SI. @ M.E.RCAD, Inc. : AUtoSPRINK® 12 02.0.59.0 10/30/2017 7:24:21AM Page 1 13(,I> o0o 1114 q 9 w Hydraulic Graph lJ Job Number KH1C ReDort Description: Resideni Water Supply at Node 1 100 90 80 70 Static Pressure 61.000 60 N a 3 50 NU) a` 40 26.04 IF 38.052 i 126.04 with hose streams 30 S stem demand curve 20 00.00 @ 20.000 10 0 0100 200 300 400 500 600 700 800 900 1000 Water flow, gpm Hyd— k Gnph Water Supply at Node 1 sUlic: Prddsurc 61,000 Rl$id.ai: Prpssuro 20.000 @ 500.00 Av.W W, P.—. ai nm p/ T.., 57.796 @ 126.04 Sn— u­ 38.052 @ 26.04 38.052 @ 126.04. & @ M.E.RCAD, Inc. §; AutoSPRINK® 12 02.0.59.0 10/30/2017 7:24:23AM Page 2 Hy/Caulk Graph Job Number: KH10 Report Description: Resident BOR 100 90 80 70 Static Pressure 61.000 60 N a 50 uNi a 40 30 26.04 @ 23.898 \00.00 26.04 with hose streams 1"' 20 @ 20.000 S stem demand curve 10 0 0100 200 300 400 500 600 700 800 900 1000 Water flow, gpm Hyd—fi Gmpn BOR Static: P.— N/A Residual: Pressure _ N/A A.aiiaela Pl—, at r tress N/A syl—D—W 23.898 @ 26.04 sy:iem o.as,d uwema HoseuiowaMa.i saa,a.l 23.898 @ N/A © M.E.P.CAD, Inc. kQJ1 AutoSPRINK® 12 02.0.59.0 10/30/2017 7:24:23AM Page 3 NO[Summary Of Outflowing Devices Job Number: KH1059 Re ort Descri Lion: Residential Device Actual Flow m Minimum Flow m K•Factor K(psi) Pressure Sprinkler 110 13.04 13.00 4.9 7.084 Sprinkler 118 13.00 13.00 4.9 7.039 Most Demanding Sprinkler Data (Al © M.E.P.CAD, Inc. y[� AUtoSPRINK® 12 v12.0.59.0 10/30/2017 72425AM Pana d Node Analysis Job Number: KH1059 Node Elevation Foot Fittings Pressure si Dischar e m 1 -3'-0 S 38.052 26.04 110 20'-0 Spr(-T.084L 7.084 13.04 118 20'-0 S r -7.039 7.039 13.00 2 -3'-0 WMV -4.000 36.389 3 -3'-0 E 9'-0 , BOR 23.898 4 1'-10 21.559 10 4'-4 .16.021 13 5'-5 15.523 14 6'-0 15.259 18 10'-0 T 6'-0 , Tr 1'-0 12.808. 25 20'-0 T 5'-0 7_788 28 26'-0 E T-0 8.067 33 20'-0 C 5'-0 7.427 41 20'-0 T 5'-0 7.567 48 20'-0 T 5'-0 7.356 18�, v ivi.c.r.cHu, inn. I.">?j AU106HKINKO 12 V12.0.59.0 10/30/2017 7:24:27AM Page 5 I4R HydraU1IC A11aIj/SIS.. UIGEE� Job Number: KH1059 Report Description: Residential Pipe Type Diameter Flow Velocity HWC. Friction Loss Length Pressure Downstream Upstream Elevation Discharge K•Factor Pt Pn Fittings Eq. Length Total Len th Summary ti$•••••Route l••••• BL 1.1010 13.00 4.38 150 0.030666 5'-4 Pf 118 48 20'-0 20'-0 13.00 4.9 7.039 7.356 Sprinkler, T 5'-0 5'-0 10'-4 0.317 Pe Pv BL 1.1010 5.28 1.78 150 0.005794 5V-6 Pf 0.432 48 25 20'-0 20'-0 7.356 7.788 6Tr(1'-0), 2T(5'-0), E(7'-0) 23'-0 74'-6 Pe Pv BL 1.1010 12.88 4.34 150 0.030133 2'-3 Pf 0.279 25 28 20'-0 20'-0 7.60 7.788 8.067 Flow (q) from Route 4 E(7'-0) T-0 9'-3 Pe Pv BL 1.3940 12.88 2.71 150 0.009550 14'-7 Pf 0.406 28 18 20'-0 10'-0 8.067 12.808 2E 8'-0 , 2T 6'-0 28'-0 42'-7 Pe 4.335 Pv BL 1.3940 26.04 5.47 150 0.035140 10'-8 18 14 10'-0 6-0 13.16 12.808 15.259 Flow (q) from Route 2 Tr(1'-0), E(8'-0) 9'-0 19'-8 Pf 0.691 Pe 1.760 Pv CM 1.3800 26.04 5.59 120 0.055775 0'-6 Pf 0.030 14 13 6-015.259 5'-5 15.523 0'-6 Pe 0.233 1 Pv CM 1.6100 26.04 4.10 120 0.026327 V-1 0.029 13 10 5'-5 4'-4 15.523 16.021 f(-0.000) V-1 �Pf Pe 0.470 Pv CM 1.3800 26.04 5.59 120 0.055775 2'-6 Pf 4.441 10 4 4'4 1'-10 16.021 21.559 BFP -4.300 2'-6 Pe 1.097 Pv UG 1.5980 26.04 4.17 150 0.018070 4'-10 Pf 0.250 4 3 1'-10 -3'-0 21,559 23,898 E(9'-0), BOR 9'-0 13'-10 Pe 2.089 Pv UG 1.5980 26.04 4.17 150 0.018070 470'-0 Pf 12A93 3 2 -3'-0 -3'-0 23.898 36,389 WMV(-4.000) 470'-0 Pe -0.002 Pv BL 1.1010 26.04 8.78 150 0.110882 15'-0 Pf 1.663 2 1 4-0 -3'-0 36,389 38.052 Water Supply 15'-0 Pe 0.000 Pv 100.00 Hose Allowance At Source 1 126.04 -w+• •Route2••••• BL 1.1010 13.04 4.40 150 0.030850 6'-1 5'-0 114-1 Pf 0.343 Pe Pv 110 20'-0 13.04 4.9 7.084 Sprinkler, 33 20'-0 7.427 C(5'-0) BL 1.1010 5.45 1.84 150 0.006133 15'-10 7'-0 22'-10 Pf 0.140 Pe Pv 33 20'-0 7.427 41 20'-0 7.567 2Tr 1'-0 , T 5'-0 BL 1.3940 13.16 2.77 150 0.009948 50'-1 4V-0 91'-1 IPV Pf 0.906 Pe 4.335 41 20'-0 7.72 7.567 Flow (q) from Route 3 18 10'-0 12.808 3E 8'-0 , 2T(6'-O), 5Tr 1'-0 +.i•••••Route 3••••• BL 1.1010 7.72 2.60 150 0.011689 8'-0 10'-0 18'-0 Pv Pf 0.211 Pe 48 20'-0 7.356 41 20'-0 7.567 2T(5'-0 •=+• ••Route4••••• BL 1.1010 7.60 2.56 150 0.011348 18'-10 jPf 13'-0 31Pv 0.361 Pe 33 20'-0 7.427 25 20'-0 7.788 E -0 , Tr 1'-0 , T 5'-0 7' Equivalent Pipe Lengths of Valves and Fittings (C`--120 only) / Actual Inside Diameter Schedule l Schedule 40 Steel Pipe Inside Diameter 4.87 ) Factor C Value Multiplier Value Of C 100 130 Multiplying Factor 0.713 1.16 140 150 1.33 1.51 p/y © M.E.P.CAD, Inc. ty AutoSPRINK® 12 v12.0.59.0 lnisnan17 D.,..,, a 41111HYdraulic Analysis Job Number: KH1059 Ro rt now i„ti,,., Pi e Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Len th Pipe Type Legend Units Legend Fittings Legend AO Arm -Over Diameter Inch ALV Alarm Valve BL Branch Line Elevation Foot Angle Valve CM Cross Main Flow gpm b Bushing ON Drain Discharge gpm BaIV Ball Valve DR Drop Velocity fps BFP Backflow Preventer DY Dynamic Pressure psi BV Butterfly Valve FM Feed Main Length Foot C Cross Flow Turn 90° FIR Feed Riser Friction Loss psi/Foot cplg Coupling MS Miscellaneous HWC Hazen -Williams Constant Cr Cross Run OR Outrigger Pt Total pressure at a point in a pipe CV Check Valve RN Riser Nipple Pn Normal pressure at a point in a pipe DeIV Deluge Valve SP Sprig Pf Pressure loss due to friction between points DPV Dry Pipe Valve ST Stand Pipe Pe Pressure due to elevation difference between indicated points E 90' Elbow UG Underground Pv Velocity pressure at a point in a pipe EE 45' Elbow Eel 11'/.' Elbow Eel 22%:° Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45" FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90' Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap Ln Hucuorrctrvr\w 1Z vIZ.V.*kI.V 10/30/2017 7:24:29AM Page 7 Check Point Gauge Data Job Number: KH1059 Job YOUNG SHORT PLAT LOT 1 9401 234TH ST SW EDMONDS, WA 98020 Design Basis Occupancy: Total Sprinklers: Number Of Sprinklers Calculated: K-Factor: Orifice Size: Design Density: Average Density: Area of Application: Demand At Base Of Riser (BOR) Total Demand Flow(gpm): -Pressure(psi): Residential 28 2 4.9 0.5 0.050gpm/ft2 0.127gpm/ft2 256.00ft2 (Actual 205.04ft2) 26.04 23.898 Water Supply Information At Time Of. Design Static Pressure(psi): 61.000 Residual Pressure(psi): 20.000 Supply Flow(gpm): 500.00 Total Demand Flow(gpm): Total Demand Pressure(psi): 126.04 38.052 Job Number: KH1059 © M.E.P.CAD, Inc. g8AutoSPRINK® 12 02.0.59.0 10/30/2017 7:24:32AM Page 9 ES-A-2000B Seises 200 B A M E S FIRE & WATERWORKS Double Check Valve :t�ssemblies Sizes: 1/2" - 2" (15 = 5Urrim) r; Features • Ease..of maintenance With only one cover" 2"2000B HC • Topentry (50mm) • Replaceable seats and seat discs • Modular construction • Compact -design • '/2° - 2M (15 - 50mm) Cast bronze body construction l ' • Top mounted ball valve test cocks W 2000B • Low pressure drop (20mm) • No special tools required Series 2000E Double Check Valve Assemblies shall be installed at referenced cross- • '/2" -1 " (15 - 25 mm) have connections to prevent the backflow of polluted water into the potable water supply. tee handles Only those cross -connections identified by local inspection authorities as non -health hazard shall be allowed the use of an approved double check valve assembly. Check with local authority having jurisdiction regarding vertical orientation, frequency Available Models of testing or other installation requirements. Suffix: These valves meet the requirements of ASSE Std. 1015 and AWWA Std. C510 and are B - Quarter turn ball valves approved by the Foundation for Cross -Connection Control and Hydraulic Research at the LBV - less ball valves University of Southern California. SH - stainless steel ball valve handles Specifications HC - 21/2" inlet/outlet fire hydrant fitting A Double Check Valve Assembly shall be installed at each noted location. The assembly (2" valve) shall consist of two positive seating check modules with captured springs and rubber seat discs. The check module seats and seat discs shall be replaceable. Service of all internal components shall be through a single access cover secured with stainless steel bolts. Pressure — Temperature The assembly shall also include two resilient seated isolation valves and four top mounted, Temperature Range: 33°F -140°F resilient seated test cocks. The assembly shall meet the requirements of ASSE Std. 1015 (0.5°C - 60°C) and AWWA Std. C510. Approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. Assembly shall be an Ames Maximum Working Pressure: 17.5psi Company Series 2000B. (12.1 bar) Approvals Assitze Standards CoO AWWA Sid. C510, IAPMO PS31 G c N C U� US us 1015 B64.5 3/+" - 2" (LBV Models Only) Approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. LBV models not listed. Horizontal and vertical "flow up" approval on all sizes. Job Name Contractor Job Location Approval Engineer Contractor's P.O. No. Approval Representative Ames product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Ames Technical Service. Ames reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously or subsequently sold. www.amesfirewater.com Dimensions - Weights Suffix HC - Fire Hydrant Fittings dimension "A" = 23'h" (594mm) SIZE ' DIMENSIONS in. mm in. A mm in. B mm C in. mm in. F mm G in. mm H in. mm in. I mm lbs. kgs. %2 15 10 254 45A 117 22/,6 62 5 127 1 3% 85 Va 59 1 21/8 52 1 4.5 2 3/ 20 11'% 282 4 102 3'% 79 63/6 157 1 37/6 87 2'/e 54 16/6 33 1 5 2.3 1 25 13'/, 337 51A 130 4 102 7'/2 191 33/e 85 11'/s 43 11'/s 43 12 5.4 1'/a 32 163/6 416 5 127 36/,6 84 9'/2 241 1 5 127 3 76 2 50 1 15 6.8 11h 40 16%4 425 1 4r/8 124 3Y2 89 9% 248 1 573/6 148 3'/8 79 1 2'%16 68 15.86 72 2 50 191/2 495 1 6'/4 159 4 102 1 133A 340 1 6'/8 156 37/6 871 211As 68 25.75 11.7 r.....-r Capacities As compiled from documented Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California lab tests. ATypical maximum system flow rate (7.5 feet/sec., 2.3 meters/sec.) kPa psi 1121, (15mm) H 83 12 0 69 10 55 8 41 6 rn 28 4 14 2 a` o 0 0 2 4 6 8 10 AP 12 gpm 0 7.6 15.2 22.8 30A 38 45.6 Ipm 5 7.5 10 fps 1.5 2.3 3.0 nips Flow Rate kPa psi si_11 i lr1- -4 m 152 22 J 124 18 96 14 3 H 69 10 41 6 a 14 2 kPa psi 96 14 (a 83 12 0 69 10 y 55 8 41 6 H 28 4 a 14 2 411.11 //lA.--..-1 . - I ...... j 0 0 1: :.1 : :I .. 1.1 1. 1 I I I I. AP 0 10 20 30 40 50 60 70 80 90 100 0 38 76 114 152 190 228 266 304 342 380 5 7.5 10 15 1.5 2.3 3.0 4.6 Flow Rate kPa psi 83 12 H 69 10 0 55 8 m 41 6 28 4 14 2 a 0 0 6P0 0 AP 0 5 10 15 28 25 30 35 40 45 50 gpm 0 19 38 57 76 95 114 133 152 171 190 Ipm 7.5 15 fps 2.3 4.6 nips kPa psi Flow Rate H 83 12 kPa psi m 110 16 n 111(25MM) 0 ss 10 J 83 12 J 55 8 69 10 y 41 6 55 8 N 28 4 y 41 6 i a 14 2 ;? 28 4 0 0 a 14 z 0 AP 0 0 AP 5 10 15 20 25 30 35 40 45 50 55 60 gpm 0 19 38 57 76 95 . 114 133 152 171 190 209 228 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps 10 20 38 76 30 40 50 60 70 80 90 too 114 152 190 228 266 304 342 380 5 7.6 10 15 1.5 2.3 3.0 4.6 Flow Rate 110 120 gpm 418 456 Ipm fps mps 110 120 gpm 418 456 Ipm fps mps 95 190 286 380 475 570 665 5 7.5 10 15 1.5 2.3 3.0 4.6 Flow Rate 200 gpm 760 Ipm fps mps Flow Rate A& A M E S 9001-2008 FIRE & WATERWORKS www.amesfirewater.com I CERTIFIED A Watts Water Technologies Company USA: Backflow- Tel: (916) 928-0123 • Fax: (916) 928-9333 Control Valves- Tel: (713) 943-0688 • Fax: (713) 944-9445 Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 ES-A-20006 1322 0 2013 Ames Fire & Waterworks Reliable Riser - Residential 1" (25mm),1/" (40mm), and 2" (50mm) sizes. For use in NFPA 13D and 13R Residential Systems Features: 1. Stainless Steel body construction. 2. All brass trim. 3. Factory assembled. 4. Factory pressure tested at 200 psi. (13.8 bar). 5. Choice of trim: • Basic Trim (Fig. 1). • Basic Trim with Pressure Relief Kit (Fig. 2). • Basic Trim with Test and Drain Valve (Fig. 3). • Basic Trim with Test and Drain Valve and Pressure Relief Kit (Fig. 4). 6. Choice of mounting options: 7 0 • Supply / System lines support. • Support Bracket (to stud) (Figs. 5 & 6). • Recessed or Flush mount (to wood panel) (Fig. 7). NPT (female x female) or tapered metric (female x female) connections. Slim design allows for easy installation within 2" x 4" on 16" centers wood frame construction. Dedicated UL Listed and ULC Listed Water Flow Detector assures optimum sensitivity. Water Flow Detector is factory installed with a metallic, weatherproof cover. Triggeringflow rate is 4(15) GPM(LPM) to 10(38)GPM(LPM). Approvals & Listings 1. Listed by Underwriters Laboratories Inc. and ULC Listed. 2. NYC MEA 258-93-E Reliable Riser - Residential Bulletin 425 Rev. B rig. i erase i nm Fig. 2 Base Trim with Pressure Relief Kit rig. j erase i nm wren i est and Dram vaive rig. a Base Trim with Test and Drain Valve & Pressure Relief Kit c CD N Cn M CD A, The Reliable Automatic SprinklerCo., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Optional Trims - Technical Data: Description Basic Trim Basic Trim with Pressure Basic Trim with Test and I Basic Trim with Test and Drain Relief Kit Drain Valve Valve & Pressure Relief Kit Take Out Dimertslorts Weigw Dimensions Wel hr Dim Ions Weight' Dimensions weight" Dirrretufal Manifold Size: inch inch kbs inch inch lbs inch inch Lbs inch inch Lbs inch mm mm (gs) mm mm (k9s) mm mm (kgs) mm mm (kgs) mm 1" 11 By, 7.3 13}, 11 8.7 11 14/4 9.0 15 14}; 10.6 8 }; 25mm 279 222 3.32 343 279 3.95 279 362 4.09 381 362 4.82 210 1}^' 11 9% 8.3 13}, 11y 10.5 11 14y; 9.7 15 14 4 11.2 8y 40mm (279) (235) 77) (343� (292) (4.77) 9) (375) (4.41) (381) (375) (5.09) (210) 2" 11 9X .8 t4.00 13}z 12 11.1 t217 15}; 10.5 15 15}; 50mm 279 248 343 305 5.05 9 387 4.77 381 387 5.55 210 * Support Bracket Kit (optional) - 1 lb (0.45 kg) All Reliable Risers have a 1" NPT drain port. Basic Trim With Pressure Relief Kit Basic Trim with Test and Drain Pressure Water Relief Nit Water Pressure B Press. Relief Pressure Gauge Press: Relief Gauge Kt (Opt.) Kit (Opt.) Manifold System Manifold System Support Body. Support Bracket Body � � Bracket \ . �1 akVe-Out) A A (Take -Out) 4 Supply Supply Drain Drain Test and Drain Drain Valve Valve Water Flow. Detector Water Flow Detector (Contact Ratings: 10A @ 125250 VAC 2.5A @ 24VDC) (Contact Ratings: 10A Q 125250 VAC 2.5A @ 24VDC) Product Description: The Reliable -Risers come factory assembled with all of the necessary accessories for a cost effective, yet complete riser solution. Reliable -Rises are [UL Listed][ULC Listed] [NYC Approved MEA 258-93-E] for horizontal or vertical installations as a one-piece, factory assembled unit for use in NFPA 13D and 13R residential sys- tems. The riser manifold assembly shall consist of a (choose one): • 1" (25 mm) cast, non -welded stainless steel body with 1" female NPT or IS07-Rol-11 threaded end connections. Fig. 5 • 1-}z' (40 mm) cast, non -welded stainless steel body with 1-y" female NPT or IS07-Rc1.5-11 threaded end connections. • 2" (50 mm) cast, non -welded, stainless steel body with 2" female NPT or IS07-Rc2-11 threaded end connections. All of these manifold sizes have cast -on lettering that clearly identifies the manifold's pipe size, flow direction, UL Listing/ ULC Listing, and the test and drain outlet. A built-in drain port is included to per- mit hydrostatic testing without draining the system. The assembly has a working pressure rating of 175 2. psi (12.1 bar). Cast -in mounting holes are provided for recessed or flush mounting to a wall. For stud mounting, a support bracket is available that is spe- cifically designed for, the cast mounting holes. All of the trim variations include brass compo- nents, a cULus Listed 300 psi water pressure gauge, and a 250 psi UL Listed/ ULC Listed Waterflow Detector. This Waterflow Detector comes factory installed with a weatherproof (outside) cover. Trim Descriptions • Basic Trim Residential riser manifold assembly trim shall include a cULus Listed pressure gauge, a drain valve, and dedicated waterflow detector containing two sets of SPDT (Form C) contacts, having an electrical rating of 10A @ 125/250 VAC/2.5 A @ 24 VDC. Triggering flow rate is 4(15) GPM(LPM) to 10(38) GPM(LPM). • Basic Trim with Pressure Relief Kit Residential riser manifold assembly trim shall include a cULus Listed pressure gauge, a drain valve, and dedicated waterflow detector containing two sets of SPDT (Form C) contacts, having an electrical rating of 10A @ 125/250 VAC/2.5 A @ 24 VDC. Triggering flow rate is 4(15) GPM(LPM) to 10(38) GPM(LPM).Pressure relief valve kit shall be provided to maintain system pressures below 175 psi (12.1 bar). • Basic Trim with Test and Drain Valve Residential riser manifold assembly trim shall include a cULus Listed pressure gauge, a Test and Drain valve, and a dedicated waterflow detector containing two sets of SPDT (Form C) contacts, having an electrical rating of 10A @ 125/250 VAC/2.5 A @ 24 VDC. Triggering flow rate is 4(15) GPM(LPM) to 10(38) GPM(LPM). The test orifice size for the Test and Drain assembly shall be** **(Choose one) • 3/8" (10 mm) • 7/16" (11 mm) • 112" (15 mm) • Basic Trim with Test and Drain Valve & Pressure Relief Kit Residential riser manifold assembly trim shall include a cULus Listed pressure gauge, a Test and Drain valve, and a dedicated waterflow detector containing two sets of SPDT (Form C) contacts, having an electrical rating of 10A @ 125/250 VAC/2.5 A @ 24 VDC. Triggering flow rate is 4(15) GPM(LPM) to 10(38) GPM(LPM). Pressure Relief Kit shall be provided to maintain system pressures below 175 psi (12,1 bar). Installation: 1. Install the manifold with the flow arrow pointing towards SYSTEM side using threaded connec- tions. 2. Connect a 1" NPT drain line. Ensure the drain Ball Valve is in the CLOSED position. 3. Place the sprinkler system in service. Caution: Automatic sprinkler systems having non -fire protection connection (permitting continual water flow) require dielectric fittings, according to NFPA 13 sect. 4-6, when dissimilar metal piping materials are joined. Note: 2 112" MIN/MUM OAP FOR WATER FLOW INDICATOR COVER R£MOVAL(TYPICAL ALL MANIFOLDS) STUD SUPPORT BRACKET MOUNT BRACKET FLUSH WITH FACE OF STUD Fig.6 WOOD PANEL PLASTIC SPACERS STUD L--------- ----J RECESSED OR FLUSH MOUNTED 3. Fig.7 or derina Information: Residential Riser Part Number Code Key 1N 1M 1.5N 1.5M 2N 2M 1 N =1' (25mm) NPi Threaded Ends Assembly 1 M =1' (25mm) Metric Threaded Ends Assembly 1.5N = 1-11Z (40mm) NPi Threaded Ends Assembly 1.5M = 1-11Z (40mm) Metric Threaded Ends Pssemb 2N = 2' (50mm) NFr Threaded Ends Assembly 2M = 2' (50mm) Metric Threaded Ends Assembly B 738 T716 T12 B = Basic Trim Assembly T12 = Basic Trim Assembly w11h 1/2 (15mm) Orif. Test and Drain Valve 0 1 2 3 0 = Assembly without Pressure Relief Kit Water Detector - UL & FM Approved 1 = Assembly with Pressure Relief Kit Water Detector - UL & FM Approved 2 = Assembly without Pressure Relief Kit Water Flow Detector - ULC Approved 3 = Assembly with Pressure Relief Kit Water Flow Detector - ULC Approved Example #1: 1.5N — B —1 (1-112" (40mm) Residential Riser Assembly with NPT Female Inlet and Outlet Threads, Basic Trim with installed Pressure Relief Kit). Example #2: 2M — T12 — 0 (2" (50mm) Residential Riser Assembly with Metric Female Inlet and Outlet Threads, Basic Trim with Test and Drain Valve having a 112" Diameter Test Orifice.) Also, If Required: Description Part Number Pressure Relief Kit For Basic Trim 98020076 Pressure Relief Kit For Basic Trim with Test and Drain Valve 6501203551 Support Bracket Kit 6899190001 Waterflow Detector RFDTH 96556910 Waterflow Detector ULC RFDTHA 96556914 Paddle Tree - Waterflow Detector 96556911 The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Rellabili The Reliable Automatic Sprinkler Co., Inc. AQRecycled (800) 431-1588 Sales Offices Paper (800) 848-05Sales Fax (914) 829-2042 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address E.G. Printed in USA 08/09 P/N9999970348 Bulletin 006 Rev. K February 2017 Reliable -M -0 M Model RFC Series Residential Sprinklers cULus Listed Flat Cover Plate, Concealed Pendent Sprinkler Product Features • cULus Listed as Residential Sprinklers • Push -On cover plate installation • Low water flow requirements Product Description Model RFC Series residential sprinklers are flat cover plate, concealed pendent sprinklers intended for installation in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The sprinklers are cULus Listed as Residential Sprinklers in ac- cordance with UL 1626. Model RFC30, RFC43, and RFC49 sprinklers have a 1650F (74°C) temperature rated fusible -link operating element. Model RFC58 sprinklers are offered with either a 1650F (74°C) or 212OF (100°C) temperature rated fusible -link op- erating element. Sprinklers with a 1650F (74°C) temperature rating are ordinary temperature classification and should be used with a 135°F (57°C) temperature rated cover plate. Sprinklers with a 212°F (100°C) temperature rating are inter- mediate temperature classification and should be used with a 165°F (74°C) temperature rated cover plate. Model RFC Series sprinklers are installed with a Model RFC cover plate. Model RFC cover plates may be installed by either pushing or threading the cover plate into the sprinkler cup. Model RFC30, RFC43, and RFC49 sprinklers allow 1/2" (13 mm) of cover plate adjustment. Model RFC58 sprinklers allow 3/4" (19 mm) of cover plate adjustment. Model RFC cover plates are available in a variety of finishes as listed in Table H. In addition, Model RFC cover plates may be ordered as either traditional solid cover plates or perforated cover plates, . , Model RFC49 1 � f Solid Perforated Model RFC Cover Plate Table Sprinkler Model Nominal K-Factor gpm/psi"2 (1/min/bar'r5 Max. Coverage Area ft x ft (m x m) Sprinkler Identification Number (SIN) RFC30 3.0 (43.2) 14 x 14 (4.3 x 4.3) RA0611 RFC43 4.3(62) 20 x 20 (6.1 x 6.1) RA0612 RFC49 4.9 (70,6) 20 x 20 (6.1 x 6.1) RA0616 RFC58 5.8 (84) - 20 x 20 (6.1 x 6.1) RA0613 www.reliablesprinkler.com Technical Specifications Cover Plate Finishes Style: Flat Concealed Pendent (See Table H) Threads: 1/2" NPT or ISO 7-1 R1/2 Nominal K-Factor: 3.0 (43.2 metric) Sensitivity Max. Working Pressure: 175 psi (12 bar) Fast -response Min. Spacing: 8 ft. (2.4 m) Temperature Rating Material Specifications 165°F (74°C) sprinkler Thermal Sensor: Nickel Alloy Solder Link 135°F (57°C) cover plate Sprinkler Body: Brass Alloy Levers: Bronze Alloy Cover Plate Yoke: Brass Alloy Model RFC cover plate Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Sprinkler Wrench Towers: Copper Alloy Model FC Pins: Stainless Steel Deflector: Bronze Alloy Listings and Approvals Cup: Steel cULus Listed Model RFC30 Sprinkler Components and Dimensions Threads Body Cup Tower ~ Fusible Link Deflector (retracted) Pin (extended) - Deflector (extended) 2-5/16" (58 mm) Dia. I 1-3/4" (44 mm) +/- 1/4" (6 mm) Nominal face of fitting to ceiling Model RFC Cover Plate Model RFC30 Sprinkler Hydraulic Design Criteria 3/16" (5 mm) veiling Table B Minimum Flow and Residual Pressure Max. Coverage Area Flow Pressure ft. x ft. gpm psi (m x m) (1/min) (bar) 12 x 12 9 9.0 (3.6 x 3.6) (34) (0.62) 14 x 14 10 11.0 (4.3 x 4.3) (38) (0,76) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table B above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max, coverage area listed. Bulletin 006 Rev. K , Page 2 of 7 February 2017 www.reliablesprinkler.com Technical Specifications Cover Plate Finishes Style: Flat Concealed Pendent (See Table H) Threads: 112" NPT or ISO 7-1 R1/2 Nominal K-Factor: 4.3 (62 metric) Sensitivity Max. Working Pressure: 175 psi (12 bar) Fast -response Min. Spacing: 8 ft. (2.4 m) Temperature Rating Material Specifications 165°F (74'C) sprinkler Thermal Sensor: Nickel Alloy Solder Link 135°F (57°C) cover plate Sprinkler Body: Brass Alloy Levers: Bronze Alloy Cover Plate Yoke: Brass Alloy Model RFC cover plate Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Sprinkler Wrench Towers: Copper Alloy Model FC Pins: Stainless Steel Deflector: Bronze Alloy Listings and Approvals Cup: Steel cULus Listed Model RFC43 Sprinkler Components and Dimensions 1111VI Body Cup Towe Fusible Li Deflector (retry Pin (exter Deflector (extend 1-3/4" (44 mm) +/- 1/4" (6 mm) Nominal face of fitting to ceiling Model RFC Cover Plate Model RFC43 Sprinkler Hvdraulic Donlan Criteria 2-5/16" (58 mm) Dia. 3-5/16" (84 mm) Dia. 3/16" (5 mm) Ceiling Minimum Flow and Residual Pressure Max. Coverage Area Flow Pressure ft. x'ft. gpm psi (m x m) (1/min) (bar) 12 x .12 12 7.8 (3.6 x 3.6) (45) (0.54) 14 x 14 13 9.1 (4.3 x 4.3) (49) (0.63) 16 x 16 13 9.1 (4.9 x 4.9) (49) (0.63) 18 x 18 18 17.5 (5.5 x 5.5) (68) (1.21) 20 x 20 21 23.8 (6.1 x 6.1) (79) (1.64) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table C above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Rev. K Page 3 of 7 February 2017 www.reliablesprinkler.com Technical Specifications Cover Plate Finishes Style: Flat Concealed Pendent (See Table H) Threads: 1/2" NPT or ISO 7-1 R1/2 Nominal K-Factor: 4,9 (70.6 metric) Sensitivity Max. Working Pressure: 175 psi (12 bar) Fast -response Min. Spacing: 8 ft. (2.4 m) Temperature Rating Material Specifications 165°F (74°C) sprinkler Thermal Sensor: Nickel Alloy Solder Link 135°F (57°C) cover plate Sprinkler Body: Brass Alloy Levers: Bronze Alloy Cover Plate Yoke: Brass Alloy Model RFC cover plate Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Sprinkler Wrench Towers: Copper Alloy Model FC Pins: Stainless Steel Deflector: Bronze Alloy Listings and Approvals Cup: Steel cULus Listed Model RFC49 Sprinkler Components and Dimensions 2-5/16" (58 mm) _ Threads Dia. Body _ Cup ~ -_. Tower 1-3/4" (44 mm)> / " (6 mm Fusible Link Nominal face of fitting to ceiling Deflector (retracted) Pin (extended) t Deflector (extended) —�� Model RFC Cover Plate 3-5/16" (84 mm) Dia Model RFC49 Sorinkler Hvdraulic Desion Criteria 3/16" (5 mm) Ceiling Table D 1 Minimum Flow and Residual Pressure Max. Coverage Area Flow Pressure ft. x ft. gpm psi (m x m) (1/min) (bar) 16 x 16 13 7.0 (4.9 x 4,9) (49.0) (0,48) 18 x 18 17 12.0 (5.5 x 5.5) (64.3) (0,83) 20 x 20 20 16.7 (6.1 x 6.1) (75.7) (1.15) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table D above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Rev. K Page 4 of 7 February 2017 a www.reliablesprinkler.com Technical Specifications Sensitivity Style: Flat Concealed Pendent Fast -response Threads: 1/2" NPT or ISO 7-1 R1/2 Nominal K-Factor: 5.8 (84 metric) Temperature Ratings Max. Working Pressure: 175 psi (12 bar) Ordinary: Min. Spacing: 8 ft. (2.4 m) 165°F (74°C) sprinkler 135°F (57°C) cover plate Material Specifications Intermediate: Thermal Sensor: Nickel Alloy Solder Link 212°F (100°C) sprinkler Sprinkler Body: Brass Alloy 165°F (74°C) cover plate Levers: Bronze Alloy Yoke: Brass Alloy Cover Plate Sealing Assembly: Nickel Alloy with PTFE Model RFC Cover Plate Load Screw: Bronze Alloy Towers: Copper Alloy Sprinkler Wrench Pins: Stainless Steel Model FC Deflector: Chrome Plated Bronze Alloy Cup: Steel Listings and Approvals cULus Listed Cover Plate Finishes (See Table H) Model RFC58 Sprinkler Components and Dimensions Threads Body = Cup _ Tower Fusible Link Deflector (retracted) Pin (extended) Deflector (extended) —� ; __ Bottom View 2-5116" (58 mm) Dia. 1-7/8" (48 mm) +/- 3/8" (9 mm) Nominal face of fitting to ceiling Model RFC Cover Plate Model RFC58 Sprinkler Hydraulic Design Criteria F 3/16" (5 mm) Ceiling Minimum Flow and Residual Pressure Max. Coverage Areatzl Flow Pressure ft. x ft. gpm psi (m x m) (1/min) (bar) 16 x 16 16 7.6 (4.9 x 4.9) (60.6) (0.53) 18 x 18 18 9.6 (5.5 x 5.5) (68.1) (0.66) 20 x 20 20 11.9 (6.1 x 6.1) (75.7) (0.82) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table E above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Rev. K Page 5 of 7 February 2017 ri2 www.reliablesprinkler.corri Cover Plate Finishes0) Standard Finishes Special Application Finishes White Polyester Off White Paint Black Paint Raw Brass Chrome Plated Bright Brass Finished Bronze Black Plated Satin Chrome Stainless Steel Clad(3) Custom Color Paint12) Notes: 1. Paint or any other coating applied over the factory finish will void all approvals and warranties. 2. Custom color paint is semi -gloss, unless specified otherwise. 3. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Allow on the backside. Cover plates are not listed or approved as corrosion resistant. Stainless steel clad cover plates are not available perforated. Installation Dimensions Recommended Min. to Min. to Max. Cover Cover Plate Hole Diameter Cover Plate Max. Face Dropped Deflector Cover Plate Sprinkler Plate Diameter in Ceiling Adjustment of Fitting to Distance below Temperature p Model Model inch inch inch Ceiling0) Ceiling Rating (mm) (mm) (mm) inch inch (mm) (mm) RFC30 RFC43 RFC 3-5/16 2-5/8 1/2 1-1/2 to 2 1/2 to 1 1350F RFC49 (84) (67) (13) (38 to 51) (13 to 25) (57°C) 135°Fi2' RFC58 RFC 3-5/16 2-5/8 3/4 1-1/2 to 2-1/4 1/4 to 1 (57°C) (84) (67) (19) (38 to 57) (6 to 25) or 165°F(3) (74°C) Notes: 1. Face of fitting to ceiling dimensions are based on a nominal thread make up. Verify dimensions based on fitting and thread sealing method prior to installation. A 1/2" x 1/2" brass nipple extension (Reliable P/N 6999991900) is available where necessary for replacement of existing sprinklers. 2. For use with 165°F (74°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 100°F (38°C). 3. For use with 212OF (100°C) temperature rated sprinklers with the Maximum Ceiling Temperature does not exceed 150°F (66°C). Installation. Model RFC series sprinklers are intended to be installed in ac- cordance with NFPA 13, NFPA 13R, or NFPA 13D, as well as the requirements of applicable authorities having jurisdiction. Mod- el RFC series sprinklers must not be installed in ceilings with positive pressure in the space above. Ensure that the 4 slots in the cup are open and unobstructed following installation. Model RFC series sprinklers are shipped with a protective cap that should remain on the sprinkler until installed. The protective cap should be replaced following installation of the sprinkler and permanently removed only when the cover plate is installed and the sprinkler system is placed in service following construction. Model RFC series sprinklers are installed with the Model FC wrench. The use of any other wrench to installed Model RFC se- ries sprinklers is not permitted and may damage the sprinkler. Temporarily remove the protective cap during installation of the sprinkler. Insert the Model FC wrench over the sprinkler until the wrench engages the body. Do not wrench any other part of the sprinkler/cup assembly. The Model FC wrench is designed to be turned with a standard 1/2" square drive. Tighten the sprin- kler into the fitting after applying a PTFE based thread sealant to the sprinkler's threads. Recommended installation torque is 8 to 18 ft/lb (11 to 24 N/m). Bulletin 006 Rev. K February 2017 Do not exceed the maximum recommended torque. Exceeding the maximum recommended torque may cause leakage or im- pairment of the sprinkler. Use care when inserting or removing the wrench from the sprinkler to avoid damage to the sprinkler. Install the cover plate by hand by pushing the cover plate into the cup and turning the cover in the clockwise direction until it is tight against the ceiling. Application Model RFC series sprinklers are intended for installation where residential sprinklers are permitted or required by NFPA 13, NFPA 13R, and NFPA 13D. The sprinklers are concealed pen- dent residential sprinklers. Model RFC 30, RFC43, and RFC49 sprinklers are available in ordinary temperature classification for installation where the Maximum Ceiling Temperature does not exceed 100OF (380C). Model RFC58 sprinklers are available in either ordinary or in- termediate temperature classification for installation where the Maximum Ceiling Temperature does not exceed 100OF (38°C) or 150°F (66°C), respectively. Page 6 of 7 www.reliablesprinkler.com Model FC Maintenance Model RFC series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by gentle vacuuming. Replace any sprinkler cover plate assembly which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non -oper- ation. Listings and Approvals Listed by Underwriters Laboratories, Inc. and UL Certified for Canada (cULus) UL Listing Category Residential Automatic Sprinkler UL Guide Number VKKW Guarantee For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, and conditions, visit www.reliablesprinkler.com, Patents Model RFC30, RFC43, RFC49, and RFC58 sprinklers are covered by U.S. Patent No. 9,248,327 and U.S. Patent No. 7,275,603. Model RFC30 and RFC43 sprinklers are additionally covered by U.S. Patent No. 8,776,903. Ordering Information Specify the following when ordering. Sprinkler • Model (RFC30, RFC43 • Temperature Rating Cover Plate • Model RFC • Temperature Rating • Finish (See Table H) Sprinkler Wrench • Model FC RFC49, RFC58) C Bulletin 006 Rev. K T� Page 7 of 7 February 2017 www.reliablesprinkler.com Reliable Features 1. The Model F3QR sprinkler utilizes Belleville Spring Closure Technology. Reliable is the first in the industry to produce a Quick Response Dry Concealed sprin- kler utilizing this technology. 2. Styles available • Pendent • Recessed FP Pendent • Recessed F1 Pendent • Concealed • Horizontal Sidewall • Recessed FP Horizontal Sidewall • Recessed F1 Horizontal Sidewall 3. 1'/z" (38mm) escutcheon adjustment on pendent sprinkler. 4. '/2" (13mm) escutcheon adjustment on recessed sprin- kler with push -on/ thread -off FP Model Escutcheon ring. 5. 3/8" (9.5mm) cover plate adjustment on concealed sprinkler with push -on/ thread -off CCP Cover. Plate. 6. 3/4" (19mm) escutcheon adjustment on recessed sprinkler with F1 Escutcheon. 7. Attractive appearance. Employs 3mm frangible glass bulb and galvanized nipple. 8. Lengths available to accommodate installation di- mensions from 2" - to - 48" (51 mm - to - 1219mm), in '/4" (6mm) increments. See specific styles for correct "A" dimension range. 9. Available in a variety of plated and painted finishes. 10. Polyester Coated Corrosion Resistant Sprinklers. US Patent Numbers. 5,775,431 and 5,967,240. Other US Patents pending. Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) Sprinkler ; Style i Response �._._.__ __ __ _ :Hazard Recessed Pendent Recessed F1 Pendent CCP Concealed Wet Pipe j Light Quick Dry Pipe ;Ordinary All Preaction i Horizontal Sidewall Wet Pipe Recessed Horizontal Sidewall Quick Dry Pipe ' Light (R5734) I All Preaction Style - Pendent Recessed F1 Pendent (R5714) Horizontal Sidewall Recessed F1 Horizontal Sidewall (R5734) Response ___..._..__._� Sprinkler Hazard System Type ____ Wet Pipe Light Quick Dry Pipe Ordinary::; All Preaction Groups 1&2 _ - Wet Pipe Quick Dry Pipe I Light I All Preaction Bulletin 157 Rev. I" Model F3QR Quick Response y Dry Sprinklers Pendent (See Fig. 1) Recessed FP Pendent (See Fig. 3) Recessed F1 Pendent (See Fig. 5) Recessed FP Horizontal Sidewall (See Fig. 8) Pendent! HB (See Fig. 2) Concealed (See Fig. 4) Horizontal Sidewall (See Fig. 6) Horizontal Sidewall / HB (See Fig. 7) 7 Recessed F1 Horizontal Sidewall (See Fig. 9) The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model F3QR Dry Pendent Sprinkler [ 'A" Dim. to 48" (51 mm to 1219mm) in 1/4" (6mm) increments Finishes(') .Sprinkler Escutcheon Bronze Brass (3) Chrome Plated Chrome Plated White Polyester 1) White (1) Other finishes and colors are available on special order. Consult factory for details. (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (1) Not available for HB escutcheons. ------------ --- I� System ice I 14-T 2 !,18" Cie. [54 Hole i., Ceiling Adj R-r9e i i % 6 4m m 1 43/64" Di + 1/4" L - 1 [42*5,,] t 1/2* [38 Imm] Tote' Adjustment Sprinkler Can Ceiling 1 11/4" [331-8mm] 1/4" [6.4mrnl, Escutcheon Es Ceiling Adjustment Escutcheon .1-1no stment Position 15/8-- of Escutcheon 41 3mm] 1/4. f6.4mm] Protrusion L 3" D f [75.2mm] ----I NrWIVFGC" Hg. 1 Note: The sprinkler can protrudes 114" when escutcheon is in nominal position. Escutcheon adjustment provides -114" (-6mm) to +1114" (+32mm) "A" dimension adjustment range. Sprinkler Guard: Model C-2 Sprinkler Installation Wrench: Model F3 Sprinkler Wrench Sprinkler Identification Number (SIN): R5714 Model F3QR D Recessed FP Pendent Sprinlder 1 "A" Dim. 131/2" to 48" (89mm to 1219mm) in 1/4" (6mm) increments Finishes") Sprinkler Escutcheon Bronze Brass Chrome Plated Chrome Plated White - Polyester (2) l_White Other finishes and colors are available on special order. Consult factory for details. Cup remainds unfinished. Only the escutcheon will contain desired finish. cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. Standard Temperature Ratings Sprinkler Max. Classification i Temperature Ambient Bulb Color Rating Tem Ordinary 1351F (571C) 100-F (38-C) Orange i Ordinary 1 155oF (68-C) 100-F (38-C) I Red Intermediate (1) 175-F (79-C) 1501F (66'C) Yellow Intermediate 1 200-F (93-C) 150'F (66'C) Green 1 High 0) 286'F(141'C) , 225'F(107'C) Blue Sprinkler cup and FP Escutcheon fabricated of steel and recommended for interior applications. (1) Listed and Certified only by cULus. Model F3QR Dry Pendent w/HB Escutcheon [ "A" Dim. 131/," to 48" (89mm to 1219mm) in 1/4" (6mm) increments Standard Temperature Ratings Sprinkler Max. Classification Temperature Ambient Bulb Color Ratin Temp. Ordinary 135'F (57-C) 1 001F (38'C) Orange Ordinary 1551F (68'C) i 1001F (38'C) Red Intermediate (1) 1750F (79oC) 1501F (66oC) Yellow Intermediate I 2001F (930C) 1501F (66'C) Green High(') 286'F (141 'C 1 225'FI107'C) , Blue _J Sprinkler can and escutcheon fabricated of brass for better weather resistance in exterior applications. (1) Listed and Certified only by cULus. Jili _J t� System Tee I OPT D 2 (6151­] —1— s!_ Renge Fr-i-- Di.. Ficle i, reilirg 1'2 1/2' [88,9­] +1/2" [t I 2.7mm] i i i Es"ths— 0:.. E%2.11'e`.2n Al-i' (25.4) Escutcheon I I.1.1 Mi. L, /2" [12.7zn! E,-th­ SpHrk!., Con Position of Escutcheon 1 - 1/4' [31.75,,,n] Non.inal Protrusion i 5/8.. 2 13/64' [55.88­] ­157row 0i.. t-1g. 2 Note: The sprinkler can protrudes 1114" when escutcheon is in nomi- nal position. Escutcheon adjustment provides -112" (-12.7mm) to +112" (+12.7mm) "A" dimension adjustment range. — - - - - - - - - - - - - - - - - - - - — - System Tee 1" N-PT [63.50m.,] "A" Dimension Hole in Ceiling Adjustment Re,ge ±1/4- 2 19/64' Die. [-t 6.35mm] [58.34,.] Nominol Position of Escutcheon n1ler V1, Sprinkler C.,Assembly Ceiling 1 [6.35mm] Escutcheon Adjustment 1/4" [6.35mm] I 3 7/32" Dic, Escutcheon Adjus t yI [�m771ij Total Adjustment N611137FGo3 I-1g. 3 Note: Do not install the Model F3QR Dry Recessed FP Pendent Sprin- kler in ceilings which have positive pressure in space above. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5714 2. Model F30R D!y Pendent Concealed Sprinkler "A" Dim. 1 114" (6mm) increments CCP Cover Plate "' Finishes "' Standard Standard Finishes Special Application Finishes ePlated lBright Brass Plated W White Black Plated Black Paint Off White Satin Chrome Utilizes the 112" cover plate with 3/8" total adjustment. Other finishes and colors are available on special order. Consult factory for details. Standard Temperature Ratings ---------- T I Sprinkler Cover Plate Max. Classification I Temperature Temp. Rating Ambient Rating i Temp. Ordinary 135°F (57°C) 135°F (57°C) 1 00-F (38°C) Ordinary 155'F (68'C) I 00'F (38'C) I 001F (38'C) Intermediate (1) 175°F (79°C) 165°F (74°C) 150°F (66'C) Intermediate 200°F (93°C) 165°F (74°C) 150-F (66-C)C) High 286°F 1 165°F (74°C) I 150-F (66 C) Sprinkler cup fabricated of steel and CCP Cover Plate fabricated of brass and recommended for interior applications. (1) Listed and Certified only by cULus. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5714 Model F30R Dry Recessed F1 Pendent Sprinkler 1/2" to 48" (89mm to 121 9mm) in 1/4" (6mm) increments] Finishes !Sprinkler — lEscutcheon lCollar iChrome Plated Chrome Plated Chrome Plated (White Polyester (2) White lWhite Other finishes and colors are available on special order. Consult factory for details. (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. Standard Temperature Ratings Sprinkler Sprinkler Sprinkler Max. Classification Classification ss T Temperature Temperature a re Ambient Bulb Color Bulb Color mp r Rating Temp. Ordinary �r�'ry �135-F (57°C) 100°F (3,8'C)' Orange Ordinary 155°F (68°C) 100°F (38°C) Red Intermediate (1) 175°F (79°C) 150°F (66°C) Yellow ow Y ' Intermediate High(') 200°F (93°C) 286,F(14loCLOC) 150°F 150oF (66°C) 225oF(107 re Green Blue Blue I" (1) Listed and Certified only by cULus. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5714 ------- ------ ------- ---- -- 2 1/2" Dio. [6.35mm] "A" Dimension Hole in Ceiling Adjustment Ran- 3/16' 2 19/64 [58.34.111 kc,;:nol Pcsiticn a' Coverpote T t4- 3/16" r4.76ml —J � cc—pl' te _Jjustm_t V16" [4 Cn,orNcte An 3 5 /16" Dic, I 4.13, rn 3/8" [9,53-1 Tat.] Adiustment System Tee I" NPT Sprinkler Cup Assembly "'Gle'Plots NZ FV 15 71160' Fig. 4 Note: Do not install the Model F3QR Dry Concealed Pendent Sprinkler in ceilings which have positive pressure in the space above. r t ------ V iAh- System Tee 2 1/2" Cio. F 1 " NPT [F3.50mmJ Hole in Ceiling i 15/16" "A" Dimension on [49.2mmj Adjustment Range 1/4" ±6.,35m,.) 15/16" NM o inol tion [23.8mrn F.f lsculc�'CeS.il Sprinkler Cup Assembly Ceiling 114" [6.35] Escutcheon Adjustment ' Escutcheon Adjustment Eszutchec, 1/2" [12.7,mm] J L Adjustment 2 27/32" [72.2'rnm-, I ---it NEIV757FG05 Fig. 5 3. Model F30R Dry Horizontal Sidewall Sprinkler "A" Dim. 2" to 48" (51mm to 1219mm) in 1/4" (6mm) increments Finishes(" Sprinkler JEscutcheon����Bronze Brass (3) Chrome Plated Chrome Platei White Polyester (2) White (1) Other finishes and colors are available on special order. Consult factory for details. (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (3) Not available for HB escutcheons. 2" [39.IVmni]J� Toto! Adjustment �-I I ' Ceiling K' "10 i.60mm] I 75rnm] _ I " [304.8Cvnm Escut[heOn kdustmerlt ��' __�I -►{ I►- 1/4" [6.35mm] System Tee Escutcheon Adjustment / 1 " t'T I \ 2 3/32' U. [76. 0rnm] 2 1/8" Dio. —� [53.98mm] 13 Hole !n Wol! Sprinkler Con \ Protrusion "A" Dimension Adjustment Nominol Position Ronne - 1/4" [-6.35mm] of Escutcheon !v=wls7r-ccc + 1 1/4 [+31.75mm] Fig. 6 Note: The sprinkler can protrudes 1/4" when escutcheon is in nominal position. Escutcheon adjustment provides -1/4" (-6mm) to +11/4" (+32mm) "A" dimension adjustment range. ") Listed and Certified only by cULus. Sprinkler Installation Wrench: Model F3 Sprinkler Wrench prinkler Identification Number (SIN): R5734 Model F30R Dry HSW w/HB Escutcheon I Dim. 31/2" to 48" (89mm to 1219mm) in'/4" (6mm) increments Standard Temperature Ratings Sprinkler Max. Classifir1750F rature Ambient Bulb Color in I Tern . Ordinary(571C) 1100'F (38'C) Orange Ordinary(68-C) i100oF (38oC) Red Intermed(790C) 150°F (66oC) YellowIntermed93-C) 1501F (66'C) GreenHi h41'C 1225oF 107'C Blue Sprinkler can and escutcheon fabricated of brass for better weather resistance in exterior applications. t" [25.4 To1cl .Adjustment Ceanc I/2'. [12.7mm] 1 Escutcheon AdiusUnent 4" [10I.EDmm] Min. 1 j [127 m] !.•• 12" [30490mrn] 1.!pv. Escutcheon .Adjustment �- Sys em Tee II3 ! IPT _ i I n F; I M', 2-13:mm r Dlc. ] [EE.9mm] ! Escutcheon Dip. 1 2 I/2" Dia. [63.5mm] 1 Mole in Wan 1-1/4" [31.75mm] Nominal jProtrusion Sprinkler Con "A" Dimension_J\\\ \ Escutcheon Adjustment \ Nominol POS;tion ..ewisxrror Rp qe r I/2" [+12.7mm] of Escutcheon 1/2" [-12.7mm] t-Ig. / Note: The sprinkler can protrudes 11/4" when escutcheon is in nomi- nal position. Escutcheon adjustment provides 112" (-12.7mm) to +1/2" (+ 12.7mm) "A" dimension adjustment range. Model F30R Dry Recessed FP Horizontal Sidewall Sprinkler "A" Dim. 31/2" to 48" (89mm to 1219mm) in l/4" (6mm) increments Finishes' " Sprinkler Escutcheon Bronze Brass Chrome Plated Chrome Plated White Polyester (2) White (1) Other finishes and colors are available on special order. Consult factory for details. Cup remainds unfinished. "See page 2" 12) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. Standard Temperature Ratings Classification Sprinkler Tem- erature RatingAmbient Max. Tem Color !Ordinary 1135-F (57-C) 100°F (38*C)Ordinary FRed I155°F. (68°C) 100°F (38'C)Intermediate f') 175-F (79-C) 150°F (66°C) Ilntermediate 200°F (93,C) 150°F (66°C) Green [High (1) _ j286°F (141-C) 225°F (1 07C) Blue (') Listed and Certified only by cULus. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5734 f-­Ced'mg 1 utch- Esceon ! 13/3] [35.7mmr ] 4` [1 CI.bm, )W, System iec u`P 3I 12" (304.fimm)Ma.. "� 1' NPT - I i (E1.8mrc] . 2 1; z' pip. [67.Smm] - Hole in Wall = 31 i Nominol Positi cr� 2 19/64" Dia of Escutcheon [58.3mm] _ [6.35) icute eon " " Gimensian Adjustment Range f Aaj slment `tcn nri;s 208 tl/4" Escutcheon ,,iAd -t Adjustment [t6.35mm] 1 j4" [6.35) Escutcheon Adjustment r FOR. FACTORY MUTUAL (FM) • 4' - FOR UNDERWRITERS LABORATORIES (UL) Fig. 8 Notes: Do not install the Model F30R Dry Recessed FP Horizontal Sidewall Sprinkler in walls which have positive pressure in their side space. • Listed by cULus for Quick Response. Approved by FM for Standard Response. • Recessed Horizontal sidewall sprinklers are listed with cLILus for installation of min. 4" 0 00mm) - to - max.. 6' (150mm) below ceiling and approved by FM for installation of min. 4" (100mm) - to - max. 12" (300mm) below ceiling. El Model F30R Dry Recessed F1 Horizontal Sidewall Sprinkler "A" Dim. 31b" to 48" (89mm to 1219mm) in (6mm) increments Finishes "' S rinkler fEscutcheon Collar _ Chrome Plated rome Plated Chrome Plated WhPolyester l2) ite White White Other finishes and colors are available on special order. Consult factory for details. 12) cLILus Listed as a Corrosion Resistant sprinkler in standard Black or White. Standard Temperature Ratings Sprinkler Max. Classification Temperature Ambient Bulb Color j Rating Temp. Ordinary 135-F (57-C) 100°F (38°C) Orange Ordinary 155-F (68-C) 1001F (38°C) Red Intermediate 11j i 1750F (79eC) 15ooF (66°C) j Yellow Intermediate 200-F (93-C) j 150°F (66°C) j Green High 000 286-F (141-C) 2251F (107°C) Blue (') Listed and Certified only by cULus. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5734 Technical Data: Orifice Size:'/2" (15mm) Thread Size: 1 " NPT per ANSI 132.1 Working Pressure: 175 psi (12 bar) Nominal K Factor - US / (Metric): 5.6 / (80) Product Description Reliable Model F3QR DrySprinklers are quick response sprinklers utilizing a durable 3mm frangible glass bulb. This quick response enables these sprinklers to apply water to a fire much sooner than standard response sprinklers of the similar temperature rating. Model F30R Dry Sprinklers are intended for use in dry and preac- tion systems and in areas subjected to freezing temperatures, such as freezers and unheated portions inside and outside buildings. Environments wherein dry sprinklers are employed can be cor- rosive. For this reason, Model F3 Sprinklers have a special wax fillet placed in the gap between the cup that supports the bulb and the wrenching boss. This wax will not interfere with the operation of the sprinkler, and it prevents contaminents from entering the internal portion of the drop nipple. The wax must not be removed. Operation The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. When the temperature increases sufficiently, due to a fire, the bulb shatters allowing operating parts to clear the waterway. This enables the inlet seal to release air or water and subsequently, cause water flow over the deflector in a uniform spray pattern, controlling or extinguishing the fire. I -rr---Ceiling -- Escutcheon [3.2mm] _ 4' (101.6mm)Min. System Tee cyrinkler Cup y 12' [304.8mm]M.a 1 NPT U_ 72.2mm] . _ j 2 1/z" Oie _J_ m1;b!I N=i,tol Position t 7.5,�16 ! --.J �of Escutcheon r49 2,nm -... __cup: heap 'EMNt^s-t j A. uinn n: n 1/2" [12Jmrn] NEIV 15 �:G0° I Adjustment Runge F.;jUSi T.^ni 31/4 [36.35mm] t; 4" [6.35] Escutcheon Adjustment # FGR FACTORY MUTUAL IEMj • 4" - 6" FOR UNDERWP.ITERS LABORATORIES (UL) Fig. 9 Listed by cULus for Quick Response. Approved by FM for Standard Response. Recessed Horizontal sidewall sprinklers are listed with cULus for installation of min. 4" (100mm) - to - max. 6" (150mm) below ceiling and approved by FM for installation of min. 4" (100mm) - to - max. 12" (300mm) below ceiling. Ordering Information Specify: 1. Sprinkler Type (select one): (a) Model F30R Dry Pendent (b) Model F3QR Dry Pendent/HB (c) Model F3QR Dry Recessed FP Pendent (d) Model F3QR Dry Recessed F1 Pendent (e) Model F3QR Dry Concealed Pendent (f) Model F3QR Dry Horizontal Sidewall (g) Model F30R Dry Horizontal Sidewall/HB (h) Model F3QR Dry.Recessed FP Horizontal Sidewall (i) Model F3QR Dry Recessed F1 Horizontal Sidewall 2. Sprinkler Temperature Rating. 3. Sprinkler Finish. 4. Escutcheon type (F1 or FP). 5. Cover Plate/Escutcheon Finish. 6. Length: "A" Dimension (face of tee to face of ceiling or wall) in (6mm) increments. 7. Model F30R Dry Pendent (a) is available without sprinkler can and escutcheon. Note: 1. The "A" dimension is based on a nominally gauged pipe thread "make-up" of 0.600" (15mm) per ANSI 132.1 [71/2 threads approximately]. ?. All platings and paintings are decorative and intend- ed for interior use. 5. General Installation Instructions Model F3QR dry sprinklers must be installed only in stan- dard (ANSI B 16.3 class 150 and ANSI B 16.4 class 125) pipe tees in the horizontal position, even at branch line ends. They should not be installed into elbows or pipe couplings located on drop nipples to the sprinklers. For these and other fittings including CPVC*, the dry sprinkler should be installed into a fitting to allow protrusion into the fitting in ac- cordance with the diagrams. The "A" dimension of the dry sprinkler, which extends into the freezers or a freezing zone from wet pipe systems, should be selected to provide, as a minimum, the specified lengths in inches shown in Fig. 10. Caution: Do not install Model F30R Dry sprinklers into CPVC adapter fittings or tees that have an internal obstruction. This will damage the sprinkler and /or the fitting. Refer to Fig. 11. During installation, the following steps must be followed 1. Cut the specified size hole (see illustrations) for the sprin- kler in the ceiling or wall directly in line with the tee. 2. Apply pipe joint compound to the 1" (25mm) pipe threads and install sprinkler using the Model F3 or XL02 Sprinkler Wrench as specified. 3. Install the Model FP push -on / thread -off escutcheon or CCP cover plate if required. Note: Installation of the Model F30R Sprinklers is not rec- ommended in copper, pipe systems, as this may reduce . the life expectancy of the sprinklers. Model F30R Concealed and Recessed In- stallation Instructions • The Model XL02 wrench (Fig. 12) is designed to lo- cate on the wrenching pads of the recessed sprin- kler while centering in the cup. A standard '/2" drive ratchet may be used to drive this wrench. Fig. 13 and Fig. 14 show sequentially the insertion of the wrench. First the wrench, with its jaws above the sprinkler de- flector, is moved laterally until centered with the cup. Then raise the wrench inside of the cup until its jaws engage the sprinkler's square wrenching pads (Fig. 14). To remove the wrench, follow this procedure in reverse order. Care should be taken to avoid striking the deflector, with the wrench. Model F3 Wrench (Fig. 15) is used for installation of Pendent and Horizontal Sidewall sprinklers. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SER- VICE FOR FIRE PROTECTION. Removal of the pro- tectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PRO- TECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. Maintenance The Model F3QR Quick Response Dry Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not remove the factory applied thermally sensitive wax fillet between the bulb sup- porting cup and the wrenching boss. Do not replace this wax with a substitute substance. An Alternate substance may interfere with proper operation of the sprinkler. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gently vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper opera- tion or non -operation. Caution: Use specified by RASCO wrenches only, which are designed to engage sprinkler's wrenching pad. (Fig. 15, page 9) RECOMMENDED EXPOSED MINIMUM BARREL LENGTH BASED ON AMBIENT TEMPERATURE IN THE PROTECTED AREA (STANDARD DRY PENDENT SPRINKLER SHOWN) AMBIENT TEMPERATURE OF PROTECTED AREACW�RG' ATE ENTHED DIS OF THE SPRINKLER BARREL AMBIENT AMBIENT TEMPERATURE 40'F 4'C I 50'F/10'C I 60'F/16'C EXPOSED MINIMUM BARREL LENGTH-- (FACE OF TEE TO TOP OF CEILING) IN. AIM IN. MM IN. MM 40'F (4'C) 0 0 0 WF (-1'C) 0 0 0 20-F (—TC) 4 (101) 0 0 10'F (—ITC) 8 (203) 1 (25.1) 0 O-F (-18'C) 12 (305) 3 (75) 0 —icm (-23'C) 14 (356) 4 (101) 1 (25.1) —20-F (-29-C) 14 (356) 6 (152) 3 (75) —30-F (-34'C) 16 (406) 8 (203) 4 (101) —40-F (-40'C) 18 (457) 6 (203) 4 (101) —50-F (-46C) 20 (508) 10 (254) 6 (152) —60'F (-51'C) 20 (508) 10 (254) 8 (152) WET i NIINIHIM (HEATED AREA) EXPOSED BARREL LENGTH i i 'A' CLEARANCE DIKNSI13N HOLE 1 • THE PROTECTED AREA REFERS TO THE AREA BELOW THE CEILING. THE AMBRNT TEMPERATURE IS THE TEMPERATURE AT THE DISCHARGE END OF THE SPRINKLER. FOR PROfE)CTED AREA TEMPERATURES THAT OCCUR BETWEEN THE VALUES 1 LLSIED. USE TIE NEXT COOLER TEMPERATURE. "Off MIN. REQUIRED BARREL LENGTH IS NOT THE SAME AS THE A' DIMENSION. NOTE: EXPOSED MINNUM BARREL LENGTHS ARE IFICLUSIVE UP TD 3OMPH WIND VELOCITIES IN THE PROTECTED AREA, O'ROTECTED AREA) INSTALL 1 INCH NPr THREADED END OF DRY PENDENT SPRINKLER INTO THE 1 INCH NPr SIDE OUTLET OF A MALLEABLE IRON TEE FITTING PER ANSI 8 16.3 (CLASS 150) OR CAST IRON THREADED TEE FRTING +i PER ANSI 16.4 (CLASS 125) ONLY. _ J.F IF HUMIDITY AND TEMPERATURE DIFFER04M CAUSES CONDENSATION ON THE EXPOSED DRY SPRINKLER, CONSIDER WRAPPING THE EXPOSED BARREL WITH INSULATION, FOAM INSULATING TAPE OR EQUIVALENT. —SEAL THE CLEARANCE SPACE AROUND THE SPRINKLER TO AVOID LEAKAGE OF AIR INTO THE PROTECTED AREA AND CONSEQUENT FORMATION OF CONDENSATE AROUND THE FRAME, WHICH COULD INHIBIT OPERATION OR CAUSE PREMATURE OPERATION. SEE BELOW FOR RECOMMENDED METHODS, *RECOMMENDED EXPOSED MINIMUM BARREL LENGTHS ALSO APPLY TO HORIZONTAL SIDEWALL DRY SPRINKLERS* RECOMMENDED DRY SPRINKLER SEAL ARRANGEMENTS WET PIPE` (STANDARD DRY PENDENT SPRINKLER SHOWN) WET PIPE -4-- FmNDN11IN E7(P 'D BARREL LECTH DECKTRE FIASHRNG (SEE RASCO #4003910 (RECOMMENDED) (PROTECTED AREA) Fig. 10 7. 04EATED AREA) MINIMUM EXPOSED BARREL LENGTH (SEE ABOVE) (PROTECTED AREA) DRY A IN COLDLD AREA EA NEW157FG10 *CAUTION* DO NOT INSTALL MODEL F3, MODEL F3QR OR MODEL DH56 HSW DRY SPRINKLERS INTO CPVC ADAPTER FITTINGS OR TEES THAT HAVE AN INTERNAL OBSTRUCTION. THIS WILL DAMAGE THE SPRINKLER AND/OR THE FITTING. CPVC ADAPTER FITTINGS AND TEES WITH INTERNAL OBSTRUCTIONS ARE ALSO COMMONLY FOUND DURING THE RETROFITTING PROCESS OF RELIABLE'S OLDER MODEL G3 DRY SPRINKLERS. INTERNAL NO OBSTRUCTION INTERNAL i OBSTRUCTION i FEMALE FEMALE i PIPE PIPE . THREAD THREAD INCORRECT CORRECT CPVC ADAPTER CPVC ADAPTER FITTING OR TEE FITTING OR TEE 1 SHORTER LONGER INLET INLET i. MALE MALE PIPE PIPE-111 THREAD i THREAD MODEL F3-PL. MODEL F30R-PL OR STANDARD MODEL DH56 HSW-PL MODEL F3, DRY SPRINKLER MODEL F30R OR MODEL DH56 HSW DRY SPRINKLER BE SURE TO ORDER THE CORRECT SPRINKLERS FOR YOUR APPLICATION 016fgO8A rig. i i L:l Fig, 12 - XLU2 Wrench Fig. 13 - XL02 Wrench t-ig. 14 - XLU2 Wrench Reliable...For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision -made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured b The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices Recycled Paper LAO () 8-051 (914914) 82929-2042 Sales Fax Corporate Offices Revision lines indicate updated or new data. v✓ww.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 12/12 P/N 9999970175